Smart Energy & Power Quality Solutions UMG 96RM. Multifunction power analyser

Similar documents
Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

POWER SIMPLY SAVE. Catalogue Catalogue 2017

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

FOUR FUNCTIONS ONE SOLUTION

UMG 511. Class A power quality analyser. Reporting Homepage

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

Smart Energy & Power Quality Solutions. UMG 96RM-PN The communications professional. Multifunctional power measurement device with PROFINET interface

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

Smart Energy & Power Quality Solutions. UMG 103-CBM energy meter with memory COMPACT, BEST-PRICED & SAFETY

Transienten. Datenspeicher

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

THE NEW GENERATION ERATION THE UMG PRO SERIES

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

Smart Energy & Power Quality Solutions. More transparency in energy distribution

Smart Energy & Power Quality Solutions. Power Quality UMG 512. Class A power quality analyser

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems

PQM - Power Quality Monitoring

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

PQM - Power Quality Monitoring

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

BACnet UMG96RM-E Functional description

Mains Monitoring Instruments 4

MIC-2 Multi-instrument DATA SHEET

Smart Energy & Power Quality Solutions. UMG 507 Power analyser

THE NEXT TRANSDUCER GENERATION

with Backlight Graphic LCD Screen

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

A2000 Multifunctional Power Meter

Smart Energy & Power Quality Solutions. Grid Visualisation Software GridVis. Energy data management- & power quality monitoring systems

Voltage Transducer UMT516 / MT516

Power Meter PowerMonitor 500

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Energy Management Energy Transducer Type ET112

Smart Energy & Power Quality Solutions. ProData data logger. Data collection and recording

RT12-240V/2.4kW Rectifier Specification

MINER-S Station Controller

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Energy Management Solutions

Mains Quality PQ-ANALYZER CLASS A

PMC 530 Series Advanced Multifunction Meter

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

RT4B-110V/12A RECTIFIER

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

RT4F-120V/20A-WAC RECTIFIER

Multifunction Transducer MT440

RT4F-110V/25A RECTIFIER

General information. Display. Supply voltage

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

EngyVolt RV12 and RV15

Expansion UMG 96RM-P Expansion UMG 96RM-CBM Power Analyser Supplementary description for the basic device for expansions -P and -CBM

General information. Display. Supply voltage

RT4F-48V/50A-WAC RECTIFIER

Scout-S Station Controller

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage

WM20. Power analyzer for three-phase systems. Benefits. Description

General information. Display. Supply voltage. Input current

Electronic Submeter with Advanced WiFi Ethernet Capability

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Energy Management BUS Adapter Type VMU-B

MINER-S Station Controller. Substation Automation

General information. Display. Supply voltage. Input current. Encoder supply. Output current

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Contact protection relay

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

RT9-48V/1.4kW Rectifier Specification

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Transcription:

Smart Energy & Power Quality Solutions UMG 96RM Multifunction power analyser

Compact high performance GridVIS Alarm management GridVis Memory 256 MB PQ Reporting Graphen Benutzerverwaltung Alarmmanagement 8 GridVis Harmonics 25. 29. 40. 63. Grenzwertüberwachung Oberschwingungen 25. Ereignisse Puls inputs Spannungsquali and outputs Measurement accuracy 0,5 RCMGrenzwertüberwachung Transienten RCM Flicker RCM Residual current measurement Allgemein A Transienten 1 2 3 Abmessungen Einsatzgebiete Technische Daten Communication (device-specific) Modbus (RTU) Profibus DP V0 TCP/IP M-Bus Allgemein B 4 MB Datenspeicher Interfaces RS485 (UMG 96RM, UMG 96RM-P, UMG 96RM-CBM) Profibus (UMG 96RM-P) M-Bus (UMG 96RM-M) Ethernet (UMG 96RM-E, UMG 96RM-EL) USB (UMG 96RM-P, UMG 96RM-CBM) Allgemein C MID Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I 32 MB 128 MB 256 MB Waveform display (UMG 96RM-EL) via GridVis -Basic software Networks TN, TT, IT networks Datenspeicher 3 and 4-phase networks Up to 4 single-phase networks Class A BACnet..-4-30 Up to 4 digital inputs Pulse input Logic input State monitoring 512 K www Homepage 32 MB 128 MB 256 MB Up to 6 digital outputs Pulse output kwh / kvarh Switch output Threshold value output Logic output Jasic Remote via Modbus / Profibus 512 K E-Mail Accuracy of measurement Energy: Class 0.5 ( / 5 A) Current: 0.5 % Voltage: 0.2 % 1 Measured data memory MID (UMG 96RM-E, UMG Class 96RM-CBM, A BACnet UMG 96RM-P)..-4-30 (UMG 96RM, UMG 96RM-M und UMG 96RM-EL without measurement data memory, energy, 2minimum and maximum 4 values will 7 be saved in the EEPROM) 256 MB Flash Tarife 1 2 8 Jasic Farbiges Grafikdisplay Network visualisation software GridVis -Basic (in the scope of supply) 14 0,2 kwh Class Residual current measurement Only available for UMG 96RM-E 8 Messgenauigkeit 0,5 kwh Class 14 2 Allgemein E Tarife O C O C O

Key features: Unrivalled in its class The compact and powerful multi-function measurement device UMG 96RM for energy measurement. It collects the electrical energy consumption, electrical standard characteristics such as current, voltage, frequency, power and much more such as power quality characteristics, e.g. harmonics, up to the 40th order. The high measurement accuracy, compact construction, extensive measurement data, multi-faceted protocol for integration into upstream systems as well as the economical design result in the UMG 96RM being unrivalled. Measurement accuracy of 0.2 % (V), kwh class = 0.5 The high sampling rate of 21.3 khz, measurement accuracy of 0.2 % (V) as well as the effective energy class 0.5 (kwh) stand for a measurement of the highest quality. Energy meter with 8 tariffs, effective energy and reactive energy The energy measurement in 4 quadrants, each with 8 tariffs for effective energy and reactive energy ensures a precise and reliable acquisition of the energy data for individual consumers or for the complete supply. Extensive communication options: Ethernet, Profibus, Modbus, M-Bus An uncomplicated system integration (energy management system, PLC, SCADA, BMS) is assured through a multitude of interfaces and protocols. The GridVis software, which is included as part of the deliverables, is the basis for energy management systems and power quality investigations. Large measurement data memory A large 256 MB measurement data memory and a user-definable recording configuration enables measurement data to be stored over a very long period. Harmonics analyser with harmonics up to 40th order The measurement of the harmonics up to the 40th order yields information about the power quality, network distur-bance and possible network contaminators. 3

Typical applications In order to achieve a sustainable reduction in energy costs, an overview of the energy consumption and the energy flows in the electrical system is first required. Whether for the build-up of energy management systems (ISO 50001), the cost centre management or the monitoring of the power quality, the universal measurement devices from the UMG 96RM range are the basis for every application. Energy data acquisition & load profile With the help of the UMG 96RM detailed acquisition of energy data and the load profile is a simple task within the scope of energy analysis. This is essential for tracking energy efficiency and the safe design of the energy distribution systems. Energy management systems Energy management systems per standard are essential for continuous improvements in energy efficiency and reduction of costs. Universal measurement devices from the UMG 96RM range are an important constituent part of energy management systems, which can also secure tax breaks amongst other benefits. Transparency of energy supply A higher degree of transparency can be attained through a multi-stage and scalable measurement system within the scope of energy measurement technology. Only by means of continuous measurement with high resolution meters, can sporadic events be analysed and corrective solutions identified. Cost centre analysis It is becoming more and more important in industrial enterprises to be able to assign energy costs to particular products and to be able to determine the breakdown and allocation of energy costs to charge them to the individual processes and consumers. This also allows employees to focus on specific cost optimisation and conservation of energy. Power quality monitoring UMG 96RM gives indispensable information about insufficient power quality and enables measures to be undertaken to address grid problems. This result is the prevention of production drop-outs, significantly longer service life for the manufacturing resources and thus an improved sustainability for the investment associated with them. 4

The variants of the UMG 96RM The UMG 96RM is available in different versions to meet the various application specific market requirements. The differences between the variants are primarily with the interfaces, protocols and configuration of the inputs and outputs. The basic device is already comprehensively equipped with a fast RS485 interface with Modbus protocol and 2 digital outputs. Profibus and digital IOs The Profibus connection is particularly used in systems where the UMG 96RM is to be incorporated into the automation environment (PLC controllers). 4th current transformer input The increasing proportion of non-linear loads leads to increasing pollution effects on the grid, in particular overloading of the neutral conductor by harmonic currents. The N-line can be continuously monitored through the 4th current input. Temperature input and analogue output (RCM) A multitude of inputs and outputs enable effective integration into upstream systems. Low voltage distribution systems, the transformer or the server cabinet can be protected from over-temperature simultaneously by means of the temperature input. Ethernet (TCP/IP) Increasingly communications are moving from typical field bus to Ethernet (TCP/IP). The UMG 96RM Ethernet connection guarantees a simple integration into the network and a fast and reliable communications architecture. M-Bus The M-Bus field bus connection for the acquisition of consumption data collection from various different consumption meters, such as water, gas, heat or electrical current. The UMG 96RM can be simply and cost-effectively integrated into economical consumption data acquisition systems via the M-Bus connection. Digital inputs and outputs Along with network transparency Smart Grid stands for the active control of energy flows and power. In addition the UMG 96RM offers a multitude of configurations for IOs for intelligent integration and control tasks. 5

GridVis network visualisation software With GridVis, Janitza offers powerful, user-friendly software for the development of energy and power quality monitoring systems. The basic version GridVis -Basic, which is part of the scope of delivery of the measurement devices, serves both for the programing and configuration of the UMG 512 and also for the reading out, saving, display, processing and analysis of the measurement data. GridVis is a comprehensive and scalable software solution for energy suppliers, industrial applications, facility management, building market and infrastructure projects. GridVis provides technicians and managers with the required data to identify potential energy savings, reduce energy costs, avoid production shutdowns and optimise the utilisation of production resources. Intuitive operation Configuration of the measurement system and the UMG measurement devices Certified ISO 50001 EnMS software Automatic or manual readout of measurement data Graphical illustration of online and historical measurement data Comprehensive alarm management User management Display of minimum, average and maximum values in a graph Statistical evaluation of the measured data Comprehensive export functions (e.g. Excel) Reports for energy usage and power quality (EN 50160, IEEE 519, EN 61000-2-4) manual or time-controlled with individual schedule Saving of data in a central database incl. database management (e.g. MySQL / MS SQL / Derby / Janitza DB) Open system architecture and scalability Generic Modbus devices, virtual meters Graphic user interface (topological view) for visualising real-time data and messages Diverse attributes are dependent on the version 6

Example network topology Ethernet level (TCP/IP) Server SQL database Client 1 to... Mobile Web server Network analysis software ProData UMG 512 UMG 508 UMG 96RM-E UMG 604 UMG 605 Fieldbus level (e.g. Modbus RTU) UMG 20CM ProData UMG 104 UMG 96RM UMG 103 Analogue / status / pulse input level Water meter Status message Gas meter Alarm lamp Temperature measurement UMG 508 / UMG 604 = Janitza power analyser UMG 512 / UMG 605 = Janitza power quality analyser UMG 96RM / UMG 96RM-E / UMG 103 / UMG 104 = Janitza multifunction energy meters UMG 96RM-E / UMG 20CM = Janitza 20 channel branch circuit monitoring device, for residual current monitoring (RCM) and energy data acquisition 7

Pluggable screw terminals The pluggable screw terminals enable convenient installation even where spaces are tight. Backlight The large high-contrast LCD display with backlighting ensures intuitive operation and good readability even in poor light conditions. Dimension diagrams All dimensions in mm max. 6 96 91,5 104 42 Side view UMG 96RM Rear view UMG 96RM (basic device) Rear view UMG 96RM-E Rear view 96RM-M M-Bus variant Rear view 96RM-EL Ethernet light variant Rear view 96RM-CBM Modbus variant Rear view 96RM-P Profibus variant The illustrations shown here are examples. Further dimensional drawings and connection diagrams are available on request or can be viewed on our homepage. 8

Typical connection 24V DC ~ K1 K2 B A 13 14 15 Digital outputs 16 17 B A RS485 UMG 96RM Basic device Power supply voltage N/- L/+ 1 2 Measuring voltage V1 V2 V3 VN 3 4 5 6 Current measurement S2 S1 S2 S1 S2 S1 Loads 230V/400V 50Hz Connection variant UMG 96RM S2 S1 S2 S1 S2 S1 L1 L2 L3 N The illustration shown here is an example. Further connection diagrams are available on request or can be viewed on our homepage. Device overview and technical data UMG 96RM UMG 96RM-M UMG 96RM-EL UMG 96RM-CBM UMG 96RM-P UMG 96RM-E Item number 52.22.035 52.22.039 52.22.040 52.22.038 52.22.037 52.22.036 Item number (ETL) *1 52.22.031 - - 52.22.032 52.22.034 52.22.033 Interfaces RS485 M-Bus Ethernet RS485, USB Protocols RS485, Profibus, USB RS485, Ethernet Modbus RTU - - Modbus TCP - - - - Profibus DP V0 - - - - - M-Bus - - - - - DHCP - - - - ICMP (Ping) - - - - Measured data recording Current measurement channel 3 3 3 4 4 4 (+2) Memory (Flash) - - - 256 MB 256 MB 256 MB Battery - - - Typ VARTA CR1/2AA, 3 V, Li-Mn Typ VARTA CR1/2AA, 3 V, Li-Mn Typ VARTA CR1/2AA, 3 V, Li-Mn Clock - - - Digital inputs and outputs Digital inputs - - - 4 4 3 *3 Digital outputs (as switch or pulse output) 2 2-6 6 2 + 3 *3 Digital inputs (RCM, temperature) - - - - - Mechanical properties Dimensions in mm (H x W x D) *2 96 x 96 x ca. 48 96 x 96 x ca. 48 96 x 96 x ca. 48 96 x 96 x ca. 78 96 x 96 x ca. 78 96 x 96 x ca. 78 Comment: For detailed technical information please refer to the operation manual and the Modbus address list. = included - = not included * 1 The Intertek-ETL sign is well respected and widely accepted in the USA and Canada. It serves as verification of compliance with the relevant standards, e.g. UL, CSA, NEC, NFPA, NSF, ANSI, NOM. Further information on ETL can be found at http://www.intertek.de/elektronik/etl-zeichen/. Source: www.intertek.de * 2 Accurate device dimensions can be found in the operation manual. * 3 Digital inputs and outputs selectable. 9

General Supply voltage AC *3 20... 250 V AC Supply voltage DC *3 20 300 V DC Supply voltage AC (ETL variants) *4 95... 240 V AC Supply voltage DC (ETL variants) *4 100... 300 V DC Use in low and medium voltage networks Accuracy voltage measurement 0.2 % Accuracy current measurement 0.5 % Accuracy active energy (kwh, /5 A) Class 0.5 Number of measurement points per period 426 Uninterrupted measurement RMS - momentary value Current, voltage, frequency Active, reactive and apparent power / total and per phase Power factor / total and per phase Energy measurement Active, reactive and apparent energy [L1,L2,L3, L1 L3] Number of tariffs 14 Recording of the mean values Voltage, current / actual and maximum Active, reactive and apparent power / actual and maximum Frequency / actual and maximum Demand calculation mode (bi-metallic function) / thermal Other measurements Operating hours measurement Power quality measurements Harmonics per order / current and voltage 1st 40th Distortion factor THD-U in % Distortion factor THD-I in % Rotary field indication Current and voltage, positive, zero and negative sequence component Rotary field indication Measured data recording Average, minimum, maximum values Alarm messages Time stamp Time basis average value freely user-defined RMS averaging, arithmetic Displays and inputs / outputs LCD display (with backlighting), 2 buttons Voltage inputs L1, L2, L3 + N Password protection Software GridVis -Basic *5 Online and historic graphs Databases (Janitza DB, Derby DB); MySQL, MS SQL with higher GridVis versions) Manual reports (energy, power quality) Topology views Manual read-out of the measuring devices Graph sets Programming / threshold values / alarm management Comparator (2 Groups with 3 comparators each) Technical data Type of measurement Constant true RMS Up to 40th harmonic Nominal voltage, three-phase, 4-conductor (L-N, L-L) 277 / 480 V AC Nominal voltage, three-phase, 3-conductor (L-L) 480 V AC Measurement in quadrants 4 Networks TN, TT, IT Comment: For detailed technical information please refer to the operation manual and the Modbus address list. = included - = not included Digital input 1 Digital input 2 Digital input 3 Digital input 4 Digital output 3 Digital output 4 Digital output 5 Digital output 6 Profibus (only -P model) LED staus bar- LED status bar for the inputs and outputs (UMG 96RM-CBM and UMG 96RM-P) Battery insertion on the rear (UMG 96RM-CBM, UMG 96RM-P and UMG 96RM-E) * 3 Relates exclusively to item numbers 52.22.035, 52.22.037, 52.22.038, 52.22.039 and 52.22.040. * 4 Relates exclusively to ETL marked devices with item numbers 52.22.031, 52.22.032, 52.22.033 and 52.22.034. * 5 Optional additional functions with the packages GridVis -Professional, GridVis -Enterprise and GridVis -Service. 10

Measured voltage input Overvoltage category 300 V CAT III Measured range, voltage L-N, AC (without potential transformer) 10 300 Vrms Measured range, voltage L-L, AC (without potential transformer) 18 520 Vrms Resolution 0.01 V Impedance 4 MOhm / phase Frequency measuring range 45... 65 Hz Power consumption approx. 0.1 VA Sampling frequency per channel (50 / 60 Hz) 21.33 / 25.6 khz Measured current input Rated current 5 A Resolution 0.1 ma Measurement range 0.001 6 Amps Overvoltage category 300 V CAT II Measurement surge voltage 2 kv Power consumption approx. 0.2 VA (Ri = 5 MOhm) Overload for 1 sec. 120 A (sinusoidal) Sampling frequency per channel (50 / 60 Hz) 21.33 / 25.6 khz Digital inputs and outputs Digital inputs *6 Maximum counting frequency 20 Hz Input signal present 18... 28 V DC (typical 4 ma) Input signal not present 0... 5 V DC, current < 0.5 ma Digital outputs *7 Switching voltage max. 60 V DC, 33 V AC Switching current max. 50 ma Eff AC / DC Response time 10 / 12 periods + 10 ms Pulse output (energy pulse) max. 50 Hz Maximum cable length up to 30 m unscreened, from 30 m screened Mechanical properties Weight approx. 0.3 kg Protection class per EN 60529 Front: IP40; Back: IP20 Assembly per IEC EN 60999-1 / DIN EN 50022 Front panel installation Cable cross section Supply voltage 0.2 to 2.5 mm² Current measurement 0.2 to 2.5 mm² Voltage measurement 0.08 to 4.0 mm² Environmental conditions Temperature range Operation: K55 (-25... +70 C) Relative humidity Operation: 0 to 90 % RH Operating height 0... 2000 m above sea level Degree of pollution 2 Installation position user-defined Electromagnetic compatibility Electromagnetic compatibility of electrical equipment Directive 2004/108/EC Electrical equipment for use within certain voltage limits Directive 2006/95/EC Equipment safety Safety requirements for electrical equipment for measurement, regulation, control and laboratory use IEC/EN 61010-1 Part 1: General requirements Part 2-030: Particular requirements for testing and measuring circuits IEC/EN 61010-2-030 Noise immunity Class A: Industrial environment IEC/EN 61326-1 Electrostatic discharge IEC/EN 61000-4-2 Voltage dips IEC/EN 61000-4-11 Emissions Class B: Residential environment IEC/EN 61326-1 Radio disturbanc voltage strength 30 1000 MHz IEC/CISPR11/EN 55011 Radiated interference voltage 0.15 30 MHz IEC/CISPR11/EN 55011 Safety Europe CE labelling USA and Canada ETL variants available Firmware Update via GridVis software. Firmware update Firmware download (free of charge) from the website: http://www.janitza.com/downloads Mounting plate Mounting clips Comment: For detailed technical information please refer to the operation manual and the Modbus address list = included - = not included Fixing screw The fastening into a switchboard is implemented via the side-mounted fastening clamps (UMG 96RM-P / UMG 96RM-CBM / UMG 96RM-E) M-Bus interface with 2-pole plug contact M+ M- 2-pole plug contact with cable connection (cable type: 2 x 0.75 mm 2 ) via twin core end sheathes * 6 The information relates exclusively to the measurement devices UMG 96RM-CBM and UMG 96RM-P. * 7 The information relates exclusively to the measurement devices UMG 96RM, UMG 96RM-M, UMG 96RM-CBM and UMG 96RM-P.96RM-P. 11

Smart Energy & Power Quality Solutions Janitza electronics GmbH Vor dem Polstück 1 D-35633 Lahnau Germany Tel.: +49 6441 9642-0 Fax: +49 6441 9642-30 info@janitza.com www.janitza.com Sales partner Item no.: 33.03.640 Doc. no.: 2.500.059.1 06/2014 Subject to technical alterations.