FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE

Similar documents
More Questions from Inspectors Numerous PV Systems Pose Issues

Stalking the Elusive and Somewhat Strange PV System

Application Techniques CENTERLINE 2100 Motor Control Centers

1. Coordination of series-rated devices is permitted where indicated on Drawings.

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Document C0. Use for:

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SERIES RATED COMBINATIONS

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Microinverters And The Solar Industry

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Bulletin Installation of solar photovoltaic systems Rules , , , , and

SECTION DISCONNECT SWITCHES


Power-Style QED-2, Series 2 Low Voltage Switchboards

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

POWER SYSTEMS STUDY: SIGNIFICANT (OR TOTAL) DELETION OF EXISTING TEXT

Want to make your inspectors happy?

Second Revision No. 1-NFPA [ Global Comment ]

Free Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL

SECTION PANELBOARDS

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

UL 508 A standard-compliant design of industrial control panel

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Electrical Service Change-Tn Neenah

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN

White Paper October 2009

FS Series PV Modules Reverse Current Overload

2008 Code Changes for Power Distribution

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

SECTION SWITCHBOARDS

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Equipment Short-Circuit Current Rating and Available Fault Current

JOURNEYMAN ELECTRICIAN

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Hubbell Surge Protective DeviceS

1510 MOTOR CONTROLLERS

CenterPoint Energy P O Box 1700 Houston, TX

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SECTION ELECTRIC METERING

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Panelboard and switchboards series rating information manual

Spring Test 9 due 05/11/2013

SECTION ( ) LIGHTING CONTROL PANELBOARD

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

NEMA Standards Publication AB Establishing Levels of Selective Coordination for Low Voltage Circuit Breakers

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

2014 NEC Code Changes. Code changes based on the 2014 NEC

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ADDENDUM NO. 1 ITB-DOT BAT. You are hereby notified that the above referenced Invitation to Bid (ITB) is modified as shown below:

3- and 4-pole switching in UPS installation

Spring Test 13 due 06/14/2013

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

Spring Test 16 due 06/14/2013

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Great Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI)

For the State of Washington SMALL GENERATOR INTERCONNECTION REQUEST (Tier 1 [Non-Net Meter], Tier 2, Tier 3) (Application Form)

B. System Design and Performance Requirements

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment.

PowerFlex 400 AC Drive Guide Specification

SMALL GENERATOR INTERCONNECTION REQUEST. (Application Form)

Photovoltaik ON GRID / OFF GRID

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Rapid Shutdown Requirements for NEC 2017

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

Overcurrent and Overvoltage Protection Changes in the 2008 NEC Code. www. ElectricalPartManuals. com

Electrical Components and Equipment for General Use Self Inspection Checklist

Spring Test 5 due 4/26/2013

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

PM Series Power Meter

To the Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems:

Entry Level Assessment Blueprint Electrical Occupations

A. Operation and Maintenance Data: For the overcurrent protective devices to include in emergency, operation, and maintenance manuals.

U.S. Virgin Islands Water and Power Authority

BuildingName The Description of the Project P DOCUMENTS

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Industrial Control Panels Tested product combinations to meet NEC Article 409 and UL 508A Standard

DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS

Electrical Plan Review

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Installation, Operation and Maintenance Manual

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

DNP Points List and Implementation

Installation Notes TII Model 341 Protector

Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 Effective May 27, 2010 Effective December 3, 2011

Transcription:

FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE INSTRUCTIONS PLEASE READ CAREFULLY Type or print legibly in black ink. Use a separate copy for each proposal. Limit each proposal to a SINGLE section. All proposals must be received by NFPA by 5 p.m., EST, Friday, November 4, 2011, to be considered for the 2014 National Electrical Code. Proposals received after 5:00 p.m., EST, Friday, November 4, 2011, will be returned to the submitter. If supplementary material (photographs, diagrams, reports, etc.) is included, you may be required to submit sufficient copies for all members and alternates of the technical committee. FOR OFFICE USE ONLY Log #: Date Rec d: For technical assistance, please call NFPA at 1-800-344-3555. Please indicate in which format you wish to receive your ROP/ROC electronic paper download (Note: If choosing the download option, you must view the ROP/ROC from our website; no copy will be sent to you.) Date 2 Nov 2011 Name John C. Wiles, Jr Tel. No. 575-646-6105 Company Southwest Technology Development Institue, New Mexico State University Email jwiles@nmsu.edu Street Address 3705 RESEARCH DR/MSC 3 SOL City LAS CRUCES State NM Zip 88003 ***If you wish to receive a hard copy, a street address MUST be provided. Deliveries cannot be made to PO boxes. Please indicate organization represented (if any) 1. Section/Paragraph 705.12(D) PV INDUSTRY FORUM 2. Proposal Recommends (check one): new text revised text deleted text 3. Proposal (include proposed new or revised wording, or identification of wording to be deleted): [Note: Proposed text should be in legislative format; i.e., use underscore to denote wording to be inserted (inserted wording) and strike-through to denote wording to be deleted (deleted wording).] Revise 705.12(D) as follows: (D) Utility-interactive Inverters. The output of a utility-interactive inverter shall be permitted to be connected to the load side of the service disconnecting means of the other source(s) at any distribution equipment on the premises. Where distribution equipment including switchboards and panelboards is fed simultaneously by a primary source(s) of electricity and one or more utility-interactive inverters, and where this distribution equipment is capable of supplying multiple branch circuits or feeders or both, the interconnecting provisions for the utility-interactive inverter(s) shall comply with (D)(1) through (D)(6 7). (1) Dedicated Overcurrent and Disconnect. Each source interconnection shall be made at a dedicated circuit breaker or fusible disconnecting means. Informational Note: The circuit carrying the ac output of a utility interactive inverter is not subject to high fault currents from the inverter. The inverter output current and power are limited to the rated values with no long-term surge capability. These ac output circuits are similar to branch circuits in terms of circuit protection and the overcurrent device should be at the utility source end, and is typically a backfed circuit breaker. (2) Bus or Conductor Ampere Rating. The continuous current output of the inverter(s) shall not exceed the ampere rating of the busbar or conductor to which they are connected. In systems where panelboards are connected in series, the ampere rating of the first overcurrent device connected directly to the inverter(s) shall be used in the calculations for all busbars and conductors. The busbar or conductor shall be sized for the loads connected in accordance with Article 220. One of the methods in (a)-(e) shall be used to determine the ratings of busbars in

panelboards or the ampacity of conductors: (a) The sum of the ampere ratings of the overcurrent devices supplying power to the busbar or conductor shall not exceed the ampacity of the busbar or conductor. Informational Note: This general rule assumes no limitation in the number of the loads or sources applied to a busbar or their locations. (b) Where two supply sources are located at opposite ends of a conductor that contains no taps, the ampacity of the conductor shall not be less than the ampere rating of the largest overcurrent device supplying power to the conductor. Permanent warning labels shall be applied at conductor access points, and at 2.8m (10 ft) intervals along accessible raceways, with the following or equivalent wording: THIS CIRCUIT FED BY MULTIPLE SOURCES DO NOT TAP CONDUCTOR. (c) Where two sources, one utility and the other an inverter, are located at opposite ends of a busbar or conductor that contains loads, the sum of the ampere ratings of the overcurrent protection supplying power to the busbar or conductor shall not exceed 120% the ampacity of the busbar or conductor. A permanent warning label shall be applied to the distribution equipment adjacent to the backfed breaker from the inverter with the following or equivalent wording: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Exception: Panelboards with multiple ampacity busworks or center fed panel boards are not addressed by this provision. (d) The sum of the ampere ratings of all overcurrent devices on panelboards, both load and supply devices, excluding the main supply overcurrent device, shall not exceed the ampacity of the busbar. The ampere rating of the main supply overcurrent device shall not exceed the rating of the busbar. Permanent warning labels shall be applied to distribution equipment with the following or equivalent wording: THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. (e) Connections shall be permitted on feeders where designed under engineering supervision that includes, but is not limited to, fault studies and conductor damage curves. Exception: Where the photovoltaic system has an energy storage device to allow stand-alone operation of loads, 125% of the rated utility-interactive current from the multimode inverter shall be permitted to be used in the calculation of bus rating or conductor ampacity instead of the

rating of the overcurrent device between the inverter and the bus or conductor. (3) Ground-Fault Protection. The interconnection point shall be on the line side of all groundfault protection equipment. Equipment requiring ground fault protection shall comply with either a or b. Exception: Connection shall be permitted to be made to the load side of ground-fault protection, provided that there is ground-fault protection for equipment from all groundfault current sources. Ground-fault protection devices used with supplies connected to the load-side terminals shall be identified and listed as suitable for backfeeding. a. The interconnection point shall be on the line side of all ground-fault protection equipment. b. The interconnection shall be permitted to be made on the load side of ground-fault protection where the following requirements are met: Ground-fault protection is provided for all equipment from all ground-fault current sources; Ground-fault protection devices used with supplies connected to the load-side terminals shall be identified and listed suitable for backfeeding; Engineering assessments shall be made to determine distribution of fault currents between the ground fault devices and the trip settings of each ground fault protection device. (4) Marking. Equipment containing overcurrent devices in circuits supplying power to a busbar or conductor supplied from multiple sources shall be marked to indicate the presence of all sources. (5) Suitable for Backfeed. Circuit breakers, if backfed, shall be suitable for such operation. Fused disconnects, unless otherwise marked, are suitable for backfeeding. FPN: Circuit breakers that are marked Line and Load have been evaluated only in the direction marked. Circuit breakers without Line and Load have been evaluated in both directions. (6) Fastening. Listed plug-in-type circuit breakers backfed from utility-interactive inverters that are listed and identified as interactive shall be permitted to omit the additional fastener normally required by 408.36(D) for such applications. (7) Inverter Output Connection. Unless the panelboard is rated not less than the sum of the ampere ratings of all overcurrent devices supplying it, a connection in a panelboard shall be positioned at the opposite (load) end from the input feeder location or main circuit location. The bus or conductor rating shall be sized for the loads connected in accordance with Article 220. In systems with panelboards connected in series, the rating of the first overcurrent device directly connected to the output of a utility-interactive inverter(s) shall be used in the calculations for all busbars and conductors. A permanent warning label shall be applied to the distribution equipment with the following or equivalent wording: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE

4. Statement of Problem and Substantiation for Proposal: (Note: State the problem that would be resolved by your recommendation; give the specific reason for your Proposal, including copies of tests, research papers, fire experience, etc. If more than 200 words, it may be abstracted for publication.) It is critical to understand that electricians regularly tap feeders and other circuits without fully verifying what is connected to the circuits. Both conductors and busbars must be protected when PV systems are connected to these circuits. This integrated proposal maintains the protection established early on in the Code for PV systems and makes safe allowances for additional connections. 690.64(B)(2)/705.12(D) was edited extensively during code making panel meetings for 2008 and was not changed in 2011. Subparagraph (D)(7) is very difficult to read and understand. New, and safe methods or connecting utility-interactive inverters to conductors and panelboards have been identified and defined. This proposed revision addresses those items and others as noted. (D) Introduction No change except in the numbering of the paragraph that was changed from 7 to 6 because (7) has been included in (2). (D)(1) No change The Informational Note is added to ensure that the ac output circuit overcurrent protection is positioned at the proper location, not at the inverter end of the circuit, where it has no affect and places the circuit under 705.12(D) sizing restrictions. (D)(2) Substantial changes to allow additional safe and cost effective methods of connecting the output of utility-interactive inverters to a panelboard bus bar or a conductor. The second sentence is extracted from 690.64(B)(2) in the 2008 NEC that was omitted in error during the transition to 705. (a) This general rule as explained by the FPN ensures that any conductor or bus bar with multiple sources and multiple loads will be protected. The position on the busbar or conductor of either the supply or the load overcurrent devices does not affect the protection under this general requirement. (b) With these restrictions on the location of sources at each end, it is not possible to overload a conductor through the connection of any load in any position. (c) This is a revision of 705.12(D)(7) for clarity. It belongs under (D), as it is a method of determining bus rating and protection. The warning is self-explanatory. The exception is required because multiple ampacity busworks center tapped bus bars cannot be protected by this method. (d) This new allowance protects the busbar or conductor by limiting the sum of the ratings of all (source and load) overcurrent devices, except the overcurrent device on the main (largest) source. For example: With a 100 amp bus, the method would allow 100 amps of supply breakers and no load breakers, 100 amps of load breakers and no supply breakers, or any combination of the two adding to 100 amps or less. The rating of the main breaker need not be counted in protecting the busbar except that its rating must also not exceed the bus bar rating. (e). This new allowance lets engineering evaluations be made by qualified people in making taps

where multiple sources of power are involved. Exception: Combinations of loads in a panel board or load center and multimode inverters frequently do not consider the fact that the multimode inverters can act as loads when operating in the battery-charging mode. This last line draws attention to that frequently overlooked fact. (3) The section is revised with the exception being deleted and replaced by two more restrictive requirements. When a PV inverter feeds a load side connection, ground faults on load circuits that were previously protected by a main breaker ground fault protective device (GFP) and sourced by the utility may now be sourced by both the utility and the inverter. Stiff grids on large service entrances may hold line voltages up preventing the inverter s anti-islanding systems from shutting the inverter down when a ground fault occurs. Ground fault currents will be divided between the utility and the inverter and inverter supplied fault currents may prevent the main breaker GFP from activating at the desired set point. Engineering assessments are needed to determine circuit impedances for the division of fault currents between multiple sources and the appropriate settings for multiple ground fault protective devices. Manufacturers maintain most new main breaker GFPs are OK for backfeeding, but cannot say about older units and for some the manufacturer may be out of business. The listing requirement has been deleted because accessories like GFP attachments to circuit breakers are not tested and listed for backfeeding. The manufacturer identifies which units are suitable for backfeeding. (4) and (5) no change. (6) Needed for clarity because many AHJs bring up this as an issue. (7) is deleted, the requirements revised for clarity, and placed in (D) (2). 5. Copyright Assignment (a) I am the author of the text or other material (such as illustrations, graphs) proposed in the Proposal. (b) Some or all of the text or other material proposed in this Proposal was not authored by me. Its source is as follows: (please identify which material and provide complete information on its source) I hereby grant and assign to the NFPA all and full rights in copyright in this Proposal and understand that I acquire no rights in any publication of NFPA in which this Proposal in this or another similar or analogous form is used. Except to the extent that I do not have authority to make an assignment in materials that I have identified in (b) above, I hereby warrant that I am the author of this Proposal and that I have full power and authority to enter into this assignment. Signature (Required) PLEASE USE SEPARATE FORM FOR EACH PROPOSAL

Mail to: Secretary, Standards Council National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 OR Fax to: (617) 770-3500 OR Email to: proposals_comments@nfpa.org 8/5/2010