ict contactors EN 61095, IEC 1095 Interference

Similar documents
Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

ic60n RCBO 30 ma IEC , IEC , AS/NZS

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Acti 9 Smartlink IEC/EN Functions

02/11/2015

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

TeSys IEC Contactors and Overload Relays

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

Contact protection relay

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.21

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Electronic timer CT-ARS.11

Motor protection relays

Datasheet - SRB 402EM-24V

EMS CX 3 - State and control module for Latching relays and Contactors

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

3 Pole Contactors with AC operating coils

Electronic timer CT-ERD.12

Electronic timer CT-AHD.22

Section 4 Ground-Fault Protection Devices

EMS CX 3 - State and control module for Latching relays and Contactors

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Mini Contactors & Overloads

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Nemo SX - Multifunction control module

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Datasheet - SRB 301LC/B-24V

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

1492-SP Supplementary Protectors

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

K-Line Mini - Contactors, Overload Relays and Accessories

Datasheet SRB301ST 24V (V.2)

TeSys contactors From 115 to 2750 A

C60 multi-standard range

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Zelio Control-modular measurement and control relays 1

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

TeSys protection components

RM35LM33MW liquid level control relay RM35-L V AC/DC

02/11/2015

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Supplementary Circuit Protectors Type GSB63

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Modular switch disconnectors and modular change-over switches

Micro Contactor MA Series

Three-phase monitoring relay

Datasheet - SLB 200-C04-1R

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

CS8 Industrial Control Relays

ARA Automatic Recloser

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Monitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview

Horizontal distribution busbar HX 3 80/125 A plug-in

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

E-STOP relays, safety gate monitors

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

PRODUCT SPECIFICATION. PC Board Relays. Series.

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Motor protection circuit breakers

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Description. Installation. Power supply

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

EMS BTDIN - State and control module for Latching relays and Contactors

RM35TF V AC

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Transcription:

ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated. The breadth of the ict contactor range satisfies most application cases. ict contactors can be combined with auxiliary control, protection and indication functions. Contactors B065-35iCT 2 B0620-34 B0624-34 B0623-34 B0775-34 B0605-35 manual control ict 4 b ict contactors can be used to remote control applications in alternative networks: v lighting, heating, ventilation, roller blinds, sanitary hot water v mechanical ventilation systems, etc v load-shedding of non-priority circuits B0625-34 Indication iacts b This auxiliary allows indication or control of the "open" or "closed" position of the contactor power contacts Interference iactp b This auxiliary is an interference suppressor which limits overvoltages on the control circuit Dual control iactc b Used to control a contactor in impulse-type mode or to combine latched or impulse-type control orders Time delay iatet b This auxiliary is used to time delay for ict and itl. According to cabling, there are 5 possible time delay types: v for itl v 4 for ict Function type A: late closing Delay energizing of contactor Function type B: time delay b Energize the contactor by closing a push button b The time delay starts as soon as the control contacts are closed Control and indication 24 V DC iact24 b Allows control and indication of a 230 Vac contactor from the Acti 9 Smartlink or by a LC, by 24 V DC signals b Also allows control by a maintained signal Function type C: late opening b Energize the contactor by closing a push button b The time delay starts when the control contacts are opened b Operate the contactor for a pre-determined time from the moment of energizing Contactors Contactors auxiliaries Type Contactor Manually-operated contactors Rating A 6 20 25 40 63 00 6 25 40 63 Auxiliaries Contactors that can be equipped with auxiliaries iacts indication auxiliary Yes Yes Yes Yes iactp protection auxiliary By yellow clips No No Yes No Yes iactc, iatet control auxiliary iact24 control auxiliary 8 By yellow clips No No Yes No Yes Non No Yes (for contactors 230 V - 50 Hz) No Yes (for contactors 230 V - 50 Hz)

ict contactors (cont.) b Insulated terminals I20 Yellow clip b Clip-on system for electrical and mechanical connections between contactors u 25 A and their auxiliaries B065-39 b Minimum noise b Large circuit labeling area b Mechanical contact position indicator b Consistent with the entire Acti 9 offer and with all types of lighting b Manually-operated contactors have a 4-position selector switch on their front face: v automatic operating mode v temporary "ON" override v permanent "ON" override: used to lock the contactor in the ON position during installation maintenance v shutdown Contactor Manually-operated contactors 6 25 40 63 40 Contactors that can be equipped with auxiliaries Yes Yes No Yes Yes No Yes Yes No Yes No 9

ict contactors (cont.) Catalogue numbers Type Width in 9 mm modules DB03378-4 DB03375-0 DB03377- DB2295 DB03373-5 Rating (In) Control voltage Contact AC7a AC7b A 6 A 6 A 2 NO A9C220 2 24 NO A9C22 2 48 NO A9C222 2 2 220 NO A9C225 2 230 240 NO A9C227 2 25 A 8.5 A 220 NO A9C2053 2 230 240 NO A9C2073 2 2 A R R3 6 A 6 A 2 2NO A9C2202 2 24 2NO A9C222 2 48 2NO A9C2222 2 R2 R4 220 2NO A9C2252 2 230...240 2NO A9C2272 2 A R 2 NO+NC A9C2205 2 24 NO+NC A9C225 2 220 NO+NC A9C2255 2 2 R2 230...240 NO+NC A9C2275 2 20 A - 230...240 2NO A9C22722 2 A 3 25 A 8.5 A 24 2NO A9C2032 2 48 2NO A9C20232 2 220 2NO A9C20532 2 2 4 230...240 2NO A9C20732 2 220 2NC A9C20536 2 230...240 2NC A9C20736 2 40 A 5 A 220...240 2NO A9C20842 4 63 A 20 A 24 2NO A9C2062 4 220...240 2NO A9C20862 4 00 A - 220...240 2NO A9C20882 6 3 A 3 5 6 A 6 A 220 240 3NO A9C2283 4 25 A 8.5 A 220 240 3NO A9C20833 4 40 A 5 A 220 240 3NO A9C20843 6 2 4 6 63 A 20 A 220 240 3NO A9C20863 6 DB2298 DB0338-8 DB2297 DB2296 4 A R R3 R5 R7 R2 R4 R6 R8 A 2 3 4 R R2 R3 R4 A 3 5 7 2 4 6 8 A 3 5 R 2 4 6 R2 6 A 6 A 24 4NO A9C224 4 220...240 4NO A9C2284 4 220...240 2NO+2NC A9C2288 4 20 A - 220...240 4NO A9C22824 4 25 A 8.5 A 24 4NO A9C2034 4 220...240 4NO A9C20834 4 24 4NC A9C2037 4 220...240 4NC A9C20837 4 220...240 2NO+2NC A9C20838 4 40 A 5 A 220...240 4NO A9C20844 6 220...240 4NC A9C20847 6 63 A 20 A 24 4NO A9C2064 6 220...240 4NO A9C20864 6 24 4NC A9C2067 6 220...240 4NC A9C20867 6 220...240 2NO+2NC A9C20868 6 220...240 3NO+NC A9C20869 6 00 A - 220...240 4NO A9C20884 2 20

ict contactors (cont.) Catalogue numbers Type Width in 9 mm modules DB0637-24 DB0638-27 DB0639-27 2 Rating (In) Control voltage Contact AC7a AC7b A 3 6 A 6 A 220 2NO A9C2352 2 230...240 I 2NO A9C2372 2 auto 220 NO+NC A9C2355 2 O 2 4 230...240 NO+NC A9C2375 2 25 A 8,5 A 24 2NO A9C232 2 A R 220 2NO A9C2532 2 230...240 I 2NO A9C2732 2 auto 40 A 5 A 24 2NO A9C242 2 O 2 R2 220...240 2NO A9C2842 4 63 A 20 A 24 2NO A9C262 4 220...240 2NO A9C2862 4 3 A 3 5 25 A 8,5 A 220...240 3NO A9C2833 4 40 A 5 A 220...240 3NO A9C2843 6 I auto O 2 4 6 4 DB06320-3 I auto O A 2 3 4 5 6 7 8 25 A 8,5 A 24 4NO A9C234 4 220...240 4NO A9C2834 4 40 A 5 A 24 4NO A9C244 6 220...240 4NO A9C2844 6 63 A 20 A 24 4NO A9C264 6 220...240 4NO A9C2864 6 2

22

ict contactors (cont.) Connection DB23606 Type Rating Lenght tripping Circuit Tightening torque Copper cables Rigid Flexible or ferrule DB22945 DB22946.5 to 2.5 mm: ict Z: 4 mm 6-00 A 9 mm Control 0.8 N.m.5 to 2.5 mm: 2 x.5 mm 2 2 x 2.5 mm 2 6 and 25 A ower.5 to 6 mm 2 to 4 mm 2 Z2: 6 mm 40 A - 63 A 4 mm 3.5 N.m 6 to 25 mm 2 6 to 6 mm 2 00 A 6 to 35 mm 2 6 to 35 mm 2 iacts, iactp, iactc, iatet Z: 4 mm - 9 mm - 0.8 N.m.5 to 2.5 mm:.5 to 2.5 mm: 2 x.5 mm 2 2 x 2.5 mm 2 DB24308 Type Terminals Tightening torque Copper cables Rigid Flexible Flexible or ferrule 3.5 mm Z DB22945 DB23553 DB23554 9 mm iact24 ower supply (N/) Input (Y/Y2) N.m 0.5 to 0 mm 2 2 x 0.5 to 2 x 2.5 mm 2 0.5 to 6 mm 2 2 x 0.5 to 2 x 2.5 mm 2 0.5 to 4 mm 2 2 x 0.5 to 2 x 2.5 mm 2 Ti24 connector connection DB23580 Spring-loaded terminals Type Catalogue numbers Copper cables Rigid Flexible 0 mm 0.4 x 2.5 mm DB22945 DB23553 Ti24 Interface A9XC242 x 0.5 to.5 mm 2 x 0.5 to.5 mm 2 B07754-0 Ti24 prefabricated cables connection Type Catalogue numbers Length Connection for Acti 9 Smartlink 6 short prefabricated A9XCAS06 00 mm 6 medium-sized prefabricated A9XCAM06 60 mm 6 long prefabricated A9XCAL06 870 mm B07755-4 Connection for LC type terminals 6 long prefabricated on a single side A9XCAU06 870 mm DB404857 24V Y3 24V O/C 0V 23

ict contactors (cont.) DB23309 DB23300 DB233 Clip on DIN rail 35 mm. ± 30 vertical. I20 I40 Technical data ower circuit Voltage rating (Ue), 2 250 V AC 3, 4 400 V AC Frequency 50 Hz or 60 Hz Type of load See module CA908026 Endurance (O-C) Electrical 00,000 cycles Maximum number of switching operation a day 00 Additional characteristics Insulation voltage (Ui) 500 V AC ollution degree 2 Rated impulse withstand voltage (Uimp) 2.5 kv (4 kv for 2/24/48 V AC) Degree of protection Device only I20 (IEC 60529) Device in modular I40 enclosure Operating temperature -5 C to +60 C () Storage temperature -40 C to +70 C Tropicalization (IEC 60068-) Treatment 2 (relative humidity 95 % at 55 C) ELSV compliance (Extra Low Safety Voltage) for 2/24/48 V AC versions The product control conforms to the SELV (safety extra low voltage) requirements () In the case of contactor mounting in a enclosure for which the interior temperature is in range between 50 C and 60 C, it is necessary to use a spacer, cat. no. A97062, between each contactor DB2333 Spacer cat. no. A97062 24

ict contactors (cont.) Mounting accessories DB24309 7 Sealable screw shields 3, 4 25 A A9A592 for top and bottom 2 40/63 A A9A5922 3, 4 40/63 A A9A5923 8 9 mm spacer A97062 9 Yellow clips A9C545 0 Clip-on terminal markers see module CA90700 0 Auxiliaries Indication 2 iacts NO + NC A9C594 CO A9C595 2NO A9C596 Double control inputs 3 iactc 230 V AC A9C8308 24 V AC A9C8309 Coil suppression blocs 4 iactp 2...48 V AC A9C599 48...27 V AC A9C598 220...240 V AC A9C5920 Time delay 5 iatet 24...240 V AC A9C549 Control and indication 6 iact24 230 V AC A9C5924 ict < 25 A ict u 25 A 25

ict contactors Electrical auxiliaries for ict Indication rotection Control Auxiliaries iacts iactp iactc Type Indication Impulse/latched control With Open/Close auxiliary contact 2 protection circuits B0620-34 B0624-34 B0623-34 Function b This auxiliary allows indication of the "open" or "closed" position of the contactor power contacts b This auxiliary is an interference suppressor which limits overvoltages on the control circuit b This auxiliary, combined with contactors, enables them to be controlled by 2 order types: v impulse order for local control (input T) v latched order for centralised control (input X) v the last order received takes priority Wiring diagrams DB23777 23 DB23778 DB23779 3 3 23 DB2336 3 DB2335 T 24 2 2 4 4 24 4 2 X Mounting Use 26 b Mounted to the right of ict b Mounted to the left of ict by yellow clips () b By wires b The iactp has 2 separate and identical circuits, allowing it to be combined with 2 different one on the ict the other by wires b Mounted to the left of ict by yellow clips () b Mains power outages: v < 70 ms: keeps its initial status v > 80 ms: reset v put back into operation by manual operation on input X or T. b Minimum impulse duration: 250 ms Catalogue numbers A9C594 A9C595 A9C596 A9C598 A9C599 A9C5920 A9C8308 A9C8309 Control voltage (Ue) V AC 24 240 48 27 2 48 220 240 230 240 24 48 V DC 24 30 Control voltage frequency Hz 50/60 50/60 50/60 Width in 9 mm modules 2 2 Auxiliary contact (breaking capacity) b Mininimum: 0 ma at 24 V DC/AC - cos = b Maximum: v 5 A at 240 V AC - cos = v A at 30 V DC Number of contacts NO + NC CO 2NO Operating C -5 C to +50 C temperature Storage temperature C -40 C to +70 C Consumption OFF load: 3 VA Inrush (2) : 2 VA Holding (2) : 0.2 VA () Electrical and mechanical link. (2) Maximum consumption of all contactors controlled.

ict contactors Electrical auxiliaries for ict (cont.) Control (cont.) iatet Time delay DB2332 DB2404 DB23323 DB23324 B0625-34 b This auxiliary is used to time delay for ict and itl. According to cabling, there are 5 possible time delay types: v for itl v 4 for ict. Function type A: late closing b Delay energizing of contactor. Function type B: time delay b Energize the contactor by closing a push button. b The time delay starts as soon as the control contacts are closed. Function type C: late opening b Energize the contactor by closing b Operate the contactor for a push button. a pre-determined time from the moment b The time delay starts when the control of energizing. contacts are opened. U U U U A ict 0 0 T t A ict 0 0 T t A ict 0 0 T t A ict 0 0 T t b Mounted to the left of ict by yellow clips () _ A9C549 24 240 24 0 50/60 2-20 C to +50 C -40 C to +80 C Off-load: 5 VA Inrush (2) : 3 A Holding (2) : 0.2 A 27

ict contactors Electrical auxiliaries for ict (cont.) Auxiliary Type Control and indication iact24 Control and indication 24 V DC With Ti24 connector B0775-34 Function Wiring diagrams DB2433 b This auxiliary allows a contactor to be interfaced with the Acti 9 Smartlink interface or a programmable logic controller (LC) in 24 V DC (control, O/C indication) b 230 V AC control Out 24 V Y3 iact24 In In 24V O/C 0V Ti24 Acti 9 Smartlink or LC Out In In Acti 9 Smartlink or LC 24 V DC 24 V DC 0 V 0 V DB2444 24 V Y3 24V O/C 0V iact24 Ti24 ON OFF Auto Mounting Wiring with exclusive selector 230 V AC control (Y = 0) / 24 V DC control (Y = ) Wiring for non-exclusive 230 V AC and 24 V DC controls b To the left of the ict contactor using the yellow clips (). b When an iact24 is used, the A/ terminals of the contactors should not be wired. Only the yellow clips integral with the iact24 should be used for connection to the coil. Utilization b 230 V AC interface: v Y: enabling of 24 V DC control (Y = ) or inhibition of 24 V DC control (Y = 0). v Y2: 230 V pulse control b "Ti24" 24 V DC interface: v Y3: 24 V DC control of ict closing on rising edge and opening on falling edge v reading of the contactor status (opened or closed) from the position of the integrated O/C auxiliary contact v monitoring of connection of the "Ti24" terminal block by the upstream system (LC, supervision system) via the 24 V terminal (in the centre of the Ti24 terminal block) Catalogue numbers A9C5924 Control voltage (Ue) V AC 230, +0 %, -5 % (Y2) V DC 24, ± 20 % (Y3) Control voltage Hz 50/60 frequency Insulation voltage V AC 250 (Ui) Rated impulse kv 8 (OVC IV) withstand voltage (Uimp) ollution degree 3 Degree of protection I20B device only I40 device in modular enclosure Width in 9 mm modules 2 Auxiliary contact (O/C) Ti24 24 V DC protected output, min. 2 ma, max. 00 ma Contact O/C operating category AC 4 Operating C -25 C to +60 C temperature Storage C -40 C to +80 C temperature Consumption < W Standard IEC/EN 60947-5- () Mechanical and electrical link. 28

ict contactors Accessories for ict Security Accessories Sealable screw shields Yellow clips Spacer B04485-5 B04486-5 B04487-5 B0643-0 B04483-40 Function Use b Designed to cover terminals to avoid contact with device screws. b Allow sealing b For ict: 3, 4-25 A b For ict: 2-40/63 A b For ict: 3, 4-40/63 A b Ensure the mechanical and/or electrical link between contactors and their auxiliaries. b For ict: 25 A b Bag of 0 upstream/0 downstream b Bag of 0 b Bag of 5 Catalogue numbers A9A592 A9A5922 A9A5923 A9C545 A97062 b Required to reduce temperature rise of modular devices installed side by side. b Recommended to separate electronic devices (thermostat, programmable clock, etc.) from electromechanical devices (relays, contactors). Width in 9 mm modules 4 4 6 Number of poles 3, 4 2 3 29

ict contactors Technical advice for ict (cont.) Operation of the iact24 O/C 24 V DC output DB2434 ict contacts O/C 24 V DC output T T arameter Min Max T Time delay between iact24 closing and indication 00 ms 200 ms b Minimum duration of 230 V AC pulse (Y2): 200 ms. b 30 iact24 closing or opening actuations are authorized per minute: Minimum time delay between 2 actuations on the iact4 via Y,Y2, Y3 (closing or opening of the ict coil): 220 ms. b 0 closing or opening actuations spaced 440 milliseconds apart are authorized following no loading of the iact24 during a period of 20 seconds. Wiring with exclusive selector 230 V AC control (Y = 0) / 24 V DC control (Y = ) Wiring for non-exclusive 230 V AC and 24 V DC controls DB24443 Out In In 24 V Y3 24V O/C 0V Acti 9 Smartlink or LC 24 V DC 0 V DB24444 Out In In 24 V Y3 24V O/C 0V Acti 9 Smartlink or LC 24 V DC 0 V Ti24 Ti24 iact24 iact24 ON OFF Auto DB2434 Y 230 V AC DB24442 Y 230 V AC Y2 230 V AC Y2 230 V AC Y3 24 V DC Y3 24 V DC ict status ict status 30

ict contactors Technical advice for ict Consumption Type Rating (In) Control voltage Consumption Max. AC7a AC7b Inrush power 6 A 5 A 2 3.8 VA 5 VA.3 W A9C220 24 3.8 VA 5 VA.3 W A9C22 48 3.8 VA 5 VA.3 W A9C222 220 3.8 VA 5 VA.3 W A9C225 230 240 2.7 VA 9.2 VA.2 W A9C227 25 A 8.5 A 220 3.8 VA 5 VA.3 W A9C2053 230 240 2.7 VA 9.2 VA.2 W A9C2073 2 6 A 5 A 2 3.8 VA 5 VA.3 W A9C2202 24 3.8 VA 5 VA.3 W A9C222 48 3.8 VA 5 VA.3 W A9C2222 220 3.8 VA 5 VA.3 W A9C2252 230...240 2.7 VA 9.2 VA.2 W A9C2272 2 3.8 VA 5 VA.3 W A9C2205 24 3.8 VA 5 VA.3 W A9C225 220 3.8 VA 5 VA.3 W A9C2255 230...240 2.7 VA 9.2 VA.2 W A9C2275 20 A 6.4 A 230...240 2.7 VA 9.2 VA.2 W A9C22722 25 A 8.5 A 24 3.8 VA 5 VA.3 W A9C2032 48 3.8 VA 5 VA.3 W A9C20232 220 3.8 VA 5 VA.3 W A9C20532 230...240 2.7 VA 9.2 VA.2 W A9C20732 220 3.8 VA 5 VA.3 W A9C20536 230...240 2.7 VA 9.2 VA.2 W A9C20736 40 A 5 A 220...240 4.6 VA 34 VA.6 W A9C20842 63 A 20 A 24 4.6 VA 34 VA.6 W A9C2062 220...240 4.6 VA 34 VA.6 W A9C20862 00 A - 220...240 6.5 VA 53 VA 2. W A9C20882 3 6 A 5 A 220 240 4.6 VA 34 VA.6 W A9C2283 25 A 8.5 A 220 240 4.6 VA 34 VA.6 W A9C20833 40 A 5 A 220 240 6.5 VA 53 VA 2. W A9C20843 63 A 20 A 220 240 6.5 VA 53 VA 2. W A9C20863 4 6 A 5 A 24 4.6 VA 34 VA.6 W A9C224 220...240 4.6 VA 34 VA.6 W A9C2284 220...240 4.6 VA 34 VA.6 W A9C2288 20 A 6.4 A 220...240 4.6 VA 34 VA.6 W A9C22824 25 A 8.5 A 24 4.6 VA 34 VA.6 W A9C2034 220...240 4.6 VA 34 VA.6 W A9C20834 24 4.6 VA 34 VA.6 W A9C2037 220...240 4.6 VA 34 VA.6 W A9C20837 220...240 4.6 VA 34 VA.6 W A9C20838 40 A 5 A 220...240 6.5 VA 53 VA 2. W A9C20844 220...240 6.5 VA 53 VA 2. W A9C20847 63 A 20 A 24 6.5 VA 53 VA 2. W A9C2064 220...240 6.5 VA 53 VA 2. W A9C20864 24 6.5 VA 53 VA 2. W A9C2067 220...240 6.5 VA 53 VA 2. W A9C20867 220...240 6.5 VA 53 VA 2. W A9C20868 220...240 6.5 VA 53 VA 2. W A9C20869 00 A - 220...240 3 VA 06 VA 4.2 W A9C20884 3

ict contactors Technical advice for ict (cont.) Consumption (cont.) Type 2 Rating (In) Control voltage Consumption Max. AC7a AC7b Inrush power 6 A 5 A 220 2.7 VA 9.2 VA.2 W A9C2352 230...240 2.7 VA 9.2 VA.2 W A9C2372 220 3.8 VA 5 VA.3 W A9C2355 230...240 2.7 VA 9.2 VA.2 W A9C2375 25 A 8.5 A 24 3.8 VA 5 VA.3 W A9C232 220 2.7 VA 9.2 VA.2 W A9C2532 230...240 2.7 VA 9.2 VA.2 W A9C2732 40 A 5 A 24 4.6 VA 34 VA.6 W A9C242 220...240 4.6 VA 34 VA.6 W A9C2842 63 A 20 A 24 4.6 VA 34 VA.6 W A9C262 220...240 4.6 VA 34 VA.6 W A9C2862 3 25 A 8.5 A 220...240 4.6 VA 34 VA.6 W A9C2833 40 A 5 A 220...240 6.5 VA 53 VA 2. W A9C2843 4 25 A 8.5 A 24 4.6 VA 34 VA.6 W A9C234 220...240 4.6 VA 34 VA.6 W A9C2834 40 A 5 A 24 6.5 VA 53 VA 2. W A9C244 220...240 6.5 VA 53 VA 2. W A9C2844 63 A 20 A 24 6.5 VA 53 VA 2. W A9C264 220...240 6.5 VA 53 VA 2. W A9C2864 32

ict contactors Dimensions for ict Dimensions (mm) DB23376 8 36 5.5 49 23.5 68 DB23609 49 36 54 5.5 23.5 68 8 45 85 45 25 2.5 ict 6/25 A ict 40/63 A DB2360 49 54 08 5.5 23.5 68 85 45 2.5 ict 00 A DB2338 49 8 36 5.5 23.5 73 68 DB23382 36 54 5.5 73 68 49 23.5 8 45 85 45 2.5 ict manual control contactor 6/25 A ict manual control contactor 40/63 A 2.5 DB23379 9 5.5 49 23.5 68 DB2436 8 5.5 68 49 DB23380 8 5 44 60 8 45 8 45 8 45 iacts iact24 iatet iactp iactc 33

ict+ high-performance contactors DB06604 EN 60669-2-2 Country approval pictograms ict+ high-performance contactors allow remote control of single-phase circuits. They are designed for demanding applications. ict+ high-performance contactors can be used for remote control of applications on AC networks: b lighting, heating, ventilation, roller blinds, domestic hot water b mechanical ventilation systems, etc. b load shedding on non-priority circuits. B0730-35 B073-35 B04483-35 E57636 ict+ Type Rating Contact Width in 9-mm modules Standard +N N L A 3 20 A NO A9C5030 2+ () Standard +N +N with manual control Spacer 2 4 +N with manual control DB2440 E57646 A N L 3 20 A NO A9C503 2+ () ict+ ict+ I auto O 2 4 () Supplied with a 9 mm spacer (cat. no. A9N27062): to be used for mounting the ict+ alongside a circuit breaker, contactor, impulse relay, etc., in order to maintain optimal operation. DB2456 DB404607 L A N 2 Spacer cat. no. A9N27062 3 4 d It is compulsory: - to connect the neutral - to keep the same control circuit connection "A: phase", ": neutral" - to use the same phase for connection of the power and control functions. Operation (manual-control contactor) ermanent stoppage Auto Temporary forced starting Automatic return to "auto" mode 34

ict+ high-performance contactors (cont.) B373-40 b Silent b Large number of switching operations They combine the benefits of static switching and electromechanical technology: small size, little temperature rise. b Green indicator on the front panel: v fixed green: auto operation v flashing green: temporary forced starting v extinguished: permanent stoppage b Operating mode selection push button: v auto operation v temporary forced starting* v permanent stoppage b Equivalent performances with all types of lamps b No derating b Orange indicator: output contact closed Connection Following a mains failure, the ict+ returns to "auto" operating mode irrespective of its initial state. DB23655 0 mm 3.5 mm Type Tightening torque DB23656 Copper cables with ferrule DB23657 without ferrule Z ict+ N.m 2 x.5 mm 2 2 x 2.5 mm 2 x 4 mm 2 Technical data DB23309 DB233 DB2333 Clip on DIN rail 35 mm. Indifferent position of installation. I20 I40 Control circuit Coil voltage (Uc) 230 V AC (± 0 %) Frequency 50 Hz Inrush power VA Holding power. VA ower circuit Voltage rating (Ue) 230 V AC (± 0 %) Frequency 50 Hz Electrical load Minimum 20 W Maximum 3600 W Max. number of switching operations per minute 6 Other characteristics Endurance (O-C) Electrical 5.000.000 cycles ollution degree 3 Degree of protection (IEC 60529) Operating temperature Storage temperature Tropicalization (IEC 60068-) Device only Device in modular enclosure I20 I40 Insulation class II -5 C to +55 C -40 C to +60 C 2 (relative humidity of 95 % at 55 C) Weight (g) Type ict+ Standard +N 70 +N with manual control 70 35