SCT 3000 Smartline Configuration Toolkit Model SCT 101 Specifications

Similar documents
MC Toolkit (Rugged & Intrinsically Safe models)

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

DevCom2000. Smart Device Communicator

Hand-held thermometer Model CTH6200

Model PC20 Intelligent Field Device Configurator for Use with Transmitters with FoxCom or HART Communication Protocol

Hand-held thermometer Model CTH6200

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017

Programming unit VIATOR HART modems Model PU-H

SCT 3000 USB-to-RS232 Converter Driver Installation Instructions

testo Saveris Adjustment software Instruction manual

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

375 Field Communicator

3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring

Calibration Kit. General Instructions. Table of Contents. System Requirements

Precision hand-held pressure indicator Model CPH6400

Advanced Test Equipment Rentals ATEC (2832) 375 Field Communicator. 375 Field Communicator. Product Data Sheet

TROVIS-VIEW software TROVIS 6661

6220 Ethernet-Based Voltage Measurement Module

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

Metasys N1 Network Integration

TA Instruments Installation Requirements for Microcalorimeter Systems

Portable Multi-Function Calibrator Model CEP6000

ATRx Biometric Package Contents: Minimum System Requirements: INSTALLATION GUIDE BIOMETRIC HANDPUNCH TECHNOLOGY

InvisaPC. Product Data Sheet OVERVIEW FEATURES

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

Serial 2-Port ExpressCard

GRYF. Measuring Instruments. measuring electrochemical and physical values. monitoring the environment. controlling technological processes

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

OPTICHECK Technical Datasheet

Customer Responsibilities

HART Communicator. Emerson Process Management Catalog

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Technical Specifications

Model 475 Field Communicator. Connection. Environmental. Shipping Weight

Advanced, Cost-effective, and Reliable HART Communication Products

USB 3.0 to VGA video adapter - on-board driver installation x1200

SoftTools Suite 7.0. Flowserve Corporation

INTECAL-W. Intecal-W. Calibration Management Software. Supports Druck Calibrators. Supports any calibrator by manual data entry

System Requirements Operating System Windows XP, Windows Vista >512 MB RAM CPU speed >2,5 GHz CD-ROM drive USB or parallel interface Important

Agilent I/O Hardware for PC-to-Instrument Connection Data Sheet

HP Deskjet 3550 Series Printers - Product Specifications

General Specifications

USB-500 Series Getting Started Contents

CalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M

Multi-functional precision thermometer CTR3000

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

Trademark. Cadex C5100 BatteryStore User Guide

OPTICHECK Technical Datasheet

Getting Started. Read Me First. series. Photo Printer

Quick Installation Guide TU-S9

APOGEE Insight Advanced Workstation

3500 Series Flat Panel Industrial PCs

Hand-Held Thermometer Model CTH 6200

THAYER SCALE. AUDiTORTM CONTINUOUS WEIGHING & FEEDING OF BULK MATERIALS. NTEP CERTIFIED Conveyor Belt Scale Monitor and Software package.

375 Field Communicator

TA Instruments Installation Requirements for Microcalorimeter Systems

375 Field Communicator

Hand-Held Pressure Indicator

Announcing IQLink v3.9.6

Logger Pro 3. Quick Reference

QUICK START. DevCom2000 User Manual

FOSTEN AUTOMATION CONF2018

TA Instruments Installation Requirements for Microcalorimeter Systems

Copyright Autodesk, Inc.

General Specifications

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

Announcing ATCLink v

Neon pr. ph/ ORP measurement. Applications. Description

Software Package Installation Instructions

Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version)

Trademark. Cadex C5100 BatteryStore v1.5 User Guide

Data Manager Installation and Update Instructions

Pre-installation Installing a microsd card Installing the USB 598 USB adapter and Watcher software

New IdeaCentre tower systems with Intel processor technology deliver high-performance computing at a competitive price

Windows-Based Terminal. TK-3550 H.W. Manual

Level TROLL 100 and Level TROLL 200 Operator s Guide

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Agilent Connectivity Hardware for PC-to-Instrument Connections. Data Sheet. with Agilent GPIB and Instrument Control Products

CompuLEAD: Installing LeadLINK Plus!

LogBook/300 Stand-alone, Intelligent PC-based, Data Acquisition System

mini USB ISDN TA128 User s Manual

Daily Monthly Report Software EcoMeasure III. User manual (Detailed version) Model MES3-SW1-DR-EN

Table of Contents. Contacting Technical Support Warranty Registration Hardware Installation...8. Using the Setup Wizard...

USB Serial Converter

2.0 GHz Pentium M 760 and 1.5 GHz Celeron M 370 Embedded Controllers for PXI

I N T E R A C T I V E W H I T E B O A R D S Y S T E M

Portable low-pressure controller Model CPC2000

SPECIAL SPECIFICATION 1432 Computer Equipment

Commercial Grade USB to RS-422/485 Adapter User's Manual

Level transmitter TR3420 Instructions manual

Dell Vostro 1014 and 1015 Setup and Features Information Tech Sheet

FG-7000 Digital Force Gauge Operation Manual

DriveWizard Plus Instruction Manual

SPECIAL PROVISION TO SPECIAL SPECIFICATION Computer Equipment

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

Sentinel Data Loggers

Transcription:

SCT 3000 Smartline Configuration Toolkit Model SCT 101 Specifications 34-CT-03-02 March 2010 Description The Smartline Configuration Toolkit is a PC-based engineering and maintenance tool designed specifically for use with Honeywell s Smartline family of field instrumentation products. The SCT 3000 is a Windows based software program that allows easy access to all Smartline configuration database parameters. Familiar Windows tools are employed in the SCT 3000 for increased user productivity, and include an on-line user manual and context sensitive help for first-time users. The SCT 3000 version 5.11.302 runs on Windows 98, 2000 operating systems and version 5.12.265 runs on Windows XP, Windows Vista Ultimate and Windows Vista Business operating systems. Function The SCT 3000 communicates with the following Honeywell Smartline products ST 3000 Pressure Transmitters * STT 3000 Temperature Transmitters, which include the STT150, STT250 and STT350 Series Figure 1 The SCT 3000 Engineering and Maintenance Software application operating on a laptop PC communicates with a variety of Honeywell Smart field devices and provides easy access to all Smartline configuration database parameters. On-line and Off-line Modes You can setup field device databases in either on-line or offline modes. The off-line mode allows you to configure and store device databases before receipt of the field devices. SMV 3000 Multivariable Transmitters MagneW and MagneW PLUS Electromagnetic Flowmeters In the on-line mode, you can download the stored databases to the devices and perform on-line functions such as: Windows-based displays Device database parameters are arranged and presented in logically grouped tab card displays. Even the casual user can easily navigate through database configuration without the need for prior training, user manuals or previous experience. Configuration and device diagnosis Calibration Display of device parameters Device check out Selection of the Communications Mode. * Will not communicate with older ST 3000 transmitters that are analog only and that contain software version 2.2 or earlier, or version 6.1 or earlier. Built-in Database Templates Default database templates are provided for each type of field device. Templates simplify and greatly reduce configuration time, effort and error by providing a logical starting point.

SCT 3000 Smartline Configuration Toolkit 2 Features Database Verification Database parameters are checked for reasonable values automatically to help avoid mistakes. The SCT 3000 compares and detects differences between the device database and the SCT database providing assurance of proper installation. Flow Wizard The SCT 3000 includes a wizard that provides considerable time savings and ease of use for users wishing to configure a transmitter. By providing responses to configuration questions and choices in a step-by-step progression, you can configure the flow process variable in a Smart Multivariable Transmitter (SMV 3000). Upon completion, a configuration solution is generated by the wizard that can be downloaded to the field device. Monitoring Graphical controls are employed so you can monitor the operating status of Smartline field devices. A display window shows you values of input PVs, output PVs and SVs of the connected device in real time. Hardware and Software Included The SCT 3000 is a bundled package that includes the hardware and software to connect and communicate with Smartline field devices. Standard hardware includes a DE / HART Modem, RS 232 Pass Thru Cable and connecting cables. USB option is also available with DE / HART Modem as an accessory item. An optional RS-232 interface (option ST) is required when using the SCT 3000 application to communicate with the STT150 temperature transmitter.

SCT 3000 Smartline Configuration Toolkit 3 System Requirements The SCT 3000 software application runs on a variety of commercially-available portable or desktop computer platforms that may also be shared with other applications. This table lists the system capabilities needed to install and operate the SCT 3000 application. PC Specification CPU Display Computer: Laptop or Desktop PC Pentium 90 MHz or better SVGA (Monochrome or Color) Operating System Windows 98, 2000, XP, Vista or Windows 7 Pointing Device Power Source Laptop PC Desktop PC Mouse or trackball-compatible device Battery powered. See Note 1. AC powered. See Note 1. RAM 16 MB (32MB recommended). See Note 2. Application Size CD ROM Drive Laptop PC Desktop PC 12 MB (application) + 5 kb per database file 4x or higher. See Note 3. Ports Parallel: Printer. See Note 4. Serial:For STT150 support and DE / HART modem support for all the other devices. See Note 3. USB Port: For STT150 support and DE / HART modem support in case the Serial port is not supported on the Laptop or PC. See Note 5. 1. Computer power source (and laptop PC s battery charger and/or AC adapter) must be suitable for worldwide use: 50-60 Hz and 100-220 VAC operation. 2. Minimum RAM capacity is 4 MB, but ROM-based portable PCs may be able to run with only 2 MB. 3. These functions require laptop PCs to have a CD ROM Drive, serial port or other mechanism for file transfers: installation of SCT 3000 software and updates configuration database import and export 4. SCT 3000 software supports any Windows 98 (or greater)-compatible printer. 5. To use the SCT 3000 on a desktop or Laptop computer without serial port, you must install USB to RS-232 Converter Driver Software. See the Installation Instructions sheet (34-ST-33-61)

SCT 3000 Smartline Configuration Toolkit 4 SCT 3000 Hardware Interface Parameters Parameter Communication Protocol DE / HART Modem (Standard Hardware Interface) Compatible with Honeywell Smart Field Network (SFN) RS-232 Interface (Option ST) Computer interface: RS232 Field Device interface: Compatible with 5Vdc level or 3Vdc level Baud Rate 9600 bps, typical 19200 bps, maximum 9600 bps, typical Temperature Range Operating Storage -10C to 50C -20C to 60C 0C to +50C (32F to +122F), ambient -40C to +85C (-40F to +185F), ambient Operating Humidity Range (RH) 10-90%, noncondensing 10-90%, noncondensing Weight (Hardware Interface + cables) Approval Bodies EUROPE 0.45lbs (approx) European EMC Standards: EEC Directive 89/336 (EMC) CE Mark 0.5 lbs., maximum European EMC Standards: CE Mark

SCT 3000 Smartline Configuration Toolkit 5 Model Selection Guide Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: http://hpsweb.honeywell.com/cultures/en-us/products/instrumentation/productmodelselectionguides/default.htm

SCT 3000 Smartline Configuration Toolkit 6 Smartline is a registered trademark of Honeywell. Windows is a registered trademark of microsoft corporation Specifications are subject to change without notice. For More Information Learn more about how Honeywell s Smartline Configuration Toolkit can increase productivity of your industry, visit our website www.honeywell.com/ps/hfs or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps 34-CT-03-02 March 2010 2010 Honeywell International Inc.