MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX

Similar documents
MICRO GROW GREENHOUSE SYSTEMS, INC

MICRO GROW GREENHOUSE SYSTEMS, INC

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

User's Guide. Model High Precision Quad Output DC Power Supply

MAXIMA + Series ROTARY LEVEL CONTROL

Evolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

Tempco Instruction Manual

S82S (3/7.5-W Models)

OZONE SWITCH Model OS-6. OS-6 Features

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

MAXIMA + Series ROTARY LEVEL CONTROL

CA-A480-A Elevator Controller. Reference & Installation Manual

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Cantata m100 Amplifier

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Application Engineering

I/O Expansion Box Installation & Operator s Instruction Manual

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

SOLARIMMERSION IV Advanced Installation Manual v1.9

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

Digital Lighting Systems, Inc.

Seven Channel Remote Control

PS8 - II. Professional Power Sequencer. User s Manual

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

MAXIMA+ Series Rotary Level Indicator

MPF-1, Mains Power Filter User Manual

Bid Specifications and General Description

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

Basketball Shot Clock Set LX2180 Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

Spec Tech Industrial Electric Technical Support. Model: DL34-(XX) Quick Start

SP6R Level Controller Operation Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Global Water Instrumentation, Inc.

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

User's Guide. MiniTec TM Series Model MN25 MultiMeter

QUICK START. Installation & Programming Guide

SAVE THESE INSTRUCTIONS

Install Motor Controller User Manual

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Brasch Washdown Unit Heaters

PRO I Series CAPACITANCE PROBE

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

GASGUARDIAN RD3 Remote Display OPERATING & INSTALLATION MANUAL

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

PMCG - MANUAL PMCG ORIGINAL INSTRUCTIONS. Preservatech Europe sp z o.o. Równa 1, Bydgoszcz, Poland

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Instruction Manual CTC-1

1411 S. Roselle Rd. Schaumburg, IL Phone (847) Fax (847)

PMDX-105 Quad Isolator Board

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

RLD-7.2 Two Channel Light Dimmer. (P/N: P-RLD-72 Digital) User & Installation Manual

212iL Rev. 1.1

TC-9102 Series Surface Mount Temperature Controllers

Smartstart Control Module

FNet Repeater Installation & Operator s Instruction Manual

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

SMD Series Integrated Stepper Driver and Motor Revision 1.3

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

Grundfos MAGNA, GENI Module

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

ETV Control ETV Valve

Digital Lighting Systems, Inc.

AE21 SERIES DISPLAY CONTROL TERMINAL

INSTRUCTION MANUAL A START-UP AND SHUT DOWN LOAD SEQUENCER AND AUTOMATIC LOAD SHEDDING SYSTEM WITH INTEGRAL RELAYS FOR 8 LOADS MODEL #091-60A

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

MR52 READER INTERFACE

LCI User Manual mantracourt.com

SAVE THESE INSTRUCTIONS

NEMA 6 Enclosure INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON.

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Transcription:

MICRO GROW GREENHOUSE SYSTEMS, INC 4065 ZEVO DR., SUITE B-, TEMECULA, CA 9590 PHONE (95)-96-3340 FAX (95)-96-3350 Growstat Series VENTSTAT

GENERAL INSTALLATION PROCEDURES PANEL MOUNTING Mount the control panel in an accessible location. Make sure that the location is free of vibration and in close proximity to the devices being controlled. Always consider voltage drop of electrical current when locating the control panel. Securely mount the panel. SWITCHING CONTACTORS AND RELAYS The control panel will operate the greenhouse equipment via load contactors and load relays. ALL RELAYS AND LOAD CONTACTORS USED MUST HAVE A SURGE SUPPRESSOR INSTALLED ACROSS THE COIL OF THE RELAY OR LOAD CONTACTOR. These surge suppressors are readily available from Micro Grow Greenhouse Systems, Inc. All load contactors and relays are also readily available from Micro Grow Greenhouse Systems, Inc. To decide which to use, follow this guide: LOAD CONTACTORS: Exhaust fans, pad pumps, horizontal air flow fans, heating pumps, fan jets, large heaters, crop lighting, and all other larger electrical loads over /6 H.P. LOAD RELAYS: Signal switching such as the small control lines for gas fired heaters, control lines for vent and shade system controls, small loads such as motorized shutters, other loads up to /6 H.P. CUSTOM CONTACTOR AND RELAY PANEL AVAILABLE A custom-built load contactor and load relay panel is available from Micro Grow Greenhouse Systems, Inc. This panel will contain all of the required switching apparatus for your project, as well as a correctly sized machine tool transformer. Contact Micro Grow Greenhouse Systems, Inc. for pricing and availability. TRANSFORMERS The control panel will be powered by a transformer. It is most important to use a MACHINE TOOL TYPE. A Machine Tool Transformer is a heavy-duty variety that will allow for high inrush currents that are associated with the use of load contactors and relays. Micro Grow Greenhouse Systems, Inc. stocks these types of transformers. Use no smaller than a 50 VA Machine Tool Transformer. For a system that has more than three load contactors connected, use a 00 VA Machine Tool Transformer. ELECTRICAL CIRCUITS The electrical circuit that feeds the machine tool transformer must have no other loads connected to it. This will prevent damaging surges from other related electrical devices. Follow all local and national codes in the connection of all of the greenhouse equipment. Always allow for voltage drop conditions. Always consider that the greenhouse is a wet environment. Always follow the code rulings for disconnect switches and over-current devices on greenhouse equipment. USE A QUALIFIED AND LICENSED ELECTRICIAN AT ALL TIMES.

WIRING METHODS Always use stranded wire when connecting cables or conductors to the actual circuit board of the control panel. This will allow flexibility. Use no smaller than #8 gauge, stranded wire for all outputs. Use no smaller than the recommended wire size of stranded cable for inputs (generally # gauge). SENSOR CONDUCTORS: Route sensor conductors separately from control conductors. This is very important so as to reduce electrical interference. Never route sensor conductors in conduits used for other voltages. This is in violation of the electrical code and will cause dangerous interference to the control system. Always locate the actual sensor in the center of the range that is being controlled for accurate readings. Do not allow the sensor to come in contact with any greenhouse structure member such as a post that would give off any radiated heat and cause a false temperature reading. Do not locate the sensor where a particular piece of equipment would cause false readings, such as a heater blowing directly on the sensor. Mount all wind/rain sensor in a clear area, free of any wind obstructions. CONTROL CONDUCTORS: Route all control conductors separately from sensor conductors. This is very important so as to reduce electrical interference. Control conductors maybe routed in conduits that contain other power system wiring only if the insulation material on the conductors is the same as the power system wiring. Consult the national electrical code or local codes if in doubt about the insulation ratings of the wire in use. Remember, always use a qualified and licensed electrician. VENT SYSTEMS, SHADE SYSTEMS, ROLL UP CURTAINS When connecting a vent system, shade system or roll up curtain ventilation system to the control panel, you must use a separate control box designed for that particular vent or shade system. These are readily available from Micro Grow Greenhouse Systems, Inc. Generally these separate control boxes feature over-current protection for the particular motor on the vent or shade system, provisions for direct limit switch connections, and a manual means of operating the vent or shade system independent of the main control system. These separate control boxes will connect the main control system either directly through the outputs of the control system, or they will require control relays for interconnection to the main control system. Consult the individual instructions that come with the vent or shade controls for detailed information. SYSTEM TESTING It is always important to completely and fully test the electrical system by energizing circuits and verifying equipment operations before automatically operating the equipment from the control panel. This would include setting all of the vent and shade limit switches at the individual control panels. 3

Ventstat Operation and Configuration Features: ` Safe, Low Voltage Operation (4VAC) ` Large, Easy-to-Read Front Panel LCD Display ` Digital Accurate Microprocessor-based Control System ` Easy-to-Use Front Panel Program Switches ` Manual Over-ride switches for all Outputs ` Weatherproof, Clear Face Enclosure with Lockable Cover ` High/Low Sensor Memory for the Past 4Hours ` Separate Day, Night and DIF Setpoints ` Digital 4 Hour Internal Clock ` Optional Weatherstation Over-ride Connections ` Includes Precision Temperature Sensor ` Includes Photocell Description: The Ventstat control operates one set (open/close) of roof vents, side vents roll-up curtains or retractable roofs. It will operate in up to eight stages without using inter-stage mercury switches. Configuration: Hook Sensors Verify Switch settings, Set Temperature:. Depress the SET switch once. The TEMPERATURE indicator will be on. Use the VALUE switch to set the correct desired setting. This will be the day mode setting. Depress the SET switch again to light the NIGHT indicator along with the TEMPERATURE indicator. Set the desired night level here.. (If DIF is not used, this instruction will not apply) If DIF is being used, the temperature setting for the DIF time period will be set next. Continue to depress the SET switch until the DIF appears on the display. The control will show the DIF temperature. Use the VALUE switch to set the desired DIF temperature. 3. Return to the run mode by toggling the RUN switch up. To Check High and Low History: The control will automatically track the high and low readings for the past 4 hours for both inputs. To check them, depress the SET switch until the word "HIGH" appears in the display. The control will automatically indicate the highest reading for the past 4 hours. Depress the SET switch until the word "LO" appears in the display. The control will automatically indicate the highest reading for the past 4 hours. If you would like to reset these values, depress VALUE switch once while the system is in the high and low mode. The system will however automatically update these readings continuously. 4

First Time Setup To Set the Vent Timing:. Continue to depress the SET switch until the word appears on the display. The control will be switching between the word and the opening time of the vent. The opening time of the vent is the time in minutes and seconds to take the vent to go from fully closed to fully open. Use the VALUE switch to raise or lower the flashing value. The first value will be minutes. Depress the SET switch again to set the seconds. To Set the Vent Positions:. Continue to depress the SET switch until the POSITION indicator is on. The display will be showing the st position and the percentage open for the vent. Use the VALUE switch to raise or lower the flashing value. Entering a value greater than 95 percent open will assume that no more stages in vent opening are to be entered. Depress the SET switch to adjust the next stage of opening. Continue until all desired stages, up to eight, are entered. To Set the Vent Override Position.. (If Vent Override Input is not used, this instruction will not apply) Continue to depress the SET switch until the display shows Or OP on the display. The display will be flashing the maximum allowed position of the vent during an override. Use the VALUE switch to raise or lower the flashing value. To Set the Clock:. Continue to depress the SET switch until the SET TIME indicator is on. The item to be set will be flashing. Use the VALUE switch to raise or lower the flashing value. The first value will be hours. Depress the SET switch again to set the minutes, and once more to set if it is AM or PM. To Set the Day and Night Mode Times: The control can detect night automatically with the use of an external photocell. If no photocell is connected, it will use the internal 4 hour time clock. You can also use a combination of both if desired.. Continue to depress the SET switch until the SET DAY MODE indicator is on. If a photocell is connected to the system, adjust the hours setting till the word "PHO" appears in the display. If a photocell is not connected, a time can be set. Use the VALUE switch to change the setting.. Depress the SET switch again and repeat the above procedure to SET NIGHT MODE. If you do not want the NIGHT mode to be used, adjust the hours setting until OFF appears in the display. To Activate the DIF Mode The Growstat has a built in DIF mode of operation. The DIF mode is used to control plant growth based on a temperature differential between the day and night modes. The Growstat allows the user to set a special time for this mode. For truly automatic operation, a photocell should be used to automatically detect the actual sunrise time. 5

To set the DIF time period:. Continue to depress the SET switch while the SET TIME indicator is on while the DIF indicator is also lit. the word "OFF" will be shown. This means that the DIF mode is disabled. By toggling the VALUE switch, a number proceeded by a negative sign will be shown (-8.0 example). This will be the number of hours before sunrise, or before the set day mode time that the Growstat will use to enter the DIF mode. Set any value in.5 hour increments desired. After this negative number is set, depress the SET switch again. A number will appear without a negative sign in front of it (.0 example). This will be number of hours after sunrise or after the set day mode that the Growstat will use to exit the DIF mode.. Return to the run mode by toggling the RUN switch up. To Calibrate the Control: The control can be calibrated easily. Calibration is best performed in the early or late hours to prevent the interaction of the solar influence. Using a good mercury or digital thermometer and hydrometer, obtain the value to calibrate the control to.. Continue to depress the SET switch until the CALIB is on the display. The first number to appear afterwards is the temperature. Use the VALUE switch to change the setting.. Depress the SET switch again and repeat the above procedure to set the humidity reading. Return to the run mode when finished. 6

DIP SWITCH SETTINGS TEMPERATURE MODE # OFF FAHRENHEIT # ON CENTIGRADE PHOTOCELL # ON PHOTOCELL IN USE # OFF NO PHOTOCELL TEMPERATURE DIFFERENTIAL # 3 OFF # 4 OFF DEGREE # 3 ON # 4 OFF DEGREES # 3 OFF # 4 ON 3 DEGREES # 3 ON # 4 ON 4 DEGREES DIF ENABLE # 5 OFF DIF NOT IN USE # 5 ON DIF IN USE TIME DELAY # 7 OFF # 8 OFF SECONDS # 7 ON # 8 OFF 30 SECONDS # 7 OFF # 8 ON 60 SECONDS # 7 ON # 8 ON 0 SECONDS SAFETY TIME DELAY # 9 OFF #0 OFF NOT USED # 9 ON #0 OFF 6 SECONDS # 9 OFF #0 ON 0 SECONDS TEMPERATURE SEPARATION # OFF # OFF DEGREE # ON # OFF DEGREES # OFF # ON 3 DEGREES # ON # ON 4 DEGREES OVERRIDE POSITIONING #6 OFF MAXIMUM POSITION ALLOWED #6 ON GO TO THAT POSITION OUTPUT NOTE: THE CONTROL OUTPUTS ARE RATED AT 5 AMP @ EACH MAXIMUM. DO NOT EXCEED THIS OR DAMAGE MAY RESULT. DO NOT EXCEED 5 AMP @ FOR ANY SINGLE OUTPUT. AIR TEMPERATURE SENSOR MON RED BLK AIR TEMPERATURE SENSOR SENSOR INPUT TERMINAL 3 +5 VDC DIP SWITCH VENT DRY SWITCHED CONTACTS VENT DRY SWITCHED CONTACTS OUTPUT 4V OVERRIDE OPTIONAL PHOTOCELL SENSOR MON MACHINE TOOL TRANSFORMER INPUT INPUT INPUT 4V RED BLK PHOTOCELL VENTSTAT INPUTS AND OUTPUTS MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project VENTSTAT INPUTS & OUTPUTS Drawn by Date Distributor Order ID SC /4/0 N/A N/A 7

OPTIONAL PHOTOCELL SENSOR MON PHOTOCELL BLACK RED AIR TEMPERATURE SENSOR TO SENSOR TERMINAL SENSOR MON AIR TEMPERATURE BLACK RED LOCATE SENSOR IN THE CENTER OF THE CONTROLLED AREA, AT BENCH OR CROP LEVEL, AWAY FROM DIRECT CONTACT WITH GREENHOUSE METAL POSTS AND MEMBERS. VENTSTAT SENSORS 0 AMP RELAY RELAY NOTES: RELAYS ARE DPDT 4, 3 = COIL, 9 = MON TERMINALS 8, 5 = NORMALLY TERMINALS 4, = NORMALLY D TERMINALS 8 4 5 4 3 9 FROM OVERRIDE DEVICE SUCH AS WEATHERMASTER OR WEATHERSTAT SENSOR MON OVERRIDE INPUT OVERRIDE MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project VENTSTAT OVERRIDE & SENSORS Drawn by Date Distributor Order ID SC /4/0 MICRO GROW N/A 8

AUX. OPN AUX. CLS 4V RLY RLY OPN RLY CLS SLAVES USE STRANDED CONDUCTORS ONLY 3 4 5 4V OPN SIGNAL INPUTS CLS LIMIT SAFETY LIMIT SIGNAL LIMIT SIGNAL LIMIT 6 7 8 9 0 LIMIT SAFETY LIMIT OPN CLS LOCK- OUTS SAFETY LIMIT BYPASS TRANSFORMER 5 4 3 RELAY RELAY 5 AMP SLOWBLOW FUSE SERIES 00 MASTER 3 +5V SENSOR INPUT TERMINAL OUTPUT 4 MON 4 INPUT VENTSTAT OUTPUT NOTE: THE CONTROL OUTPUTS ARE RATED AT 5 AMP EACH. VENTSTAT CONNECTION TO SERIES 00 MASTER MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project VENTSTAT CONNECTION TO SERIES 00 MASTER Drawn by Date Distributor Order ID SC /4/0 N/A N/A

AUX. OPN AUX. CLS 4V RLY RLY OPN RLY CLS SLAVES USE STRANDED CONDUCTORS ONLY 3 4 5 4V OPN CLS SIGNAL INPUTS LIMIT SAFETY LIMIT SIGNAL LIMIT SIGNAL LIMIT 6 7 8 9 0 OPN CLS SAFETY LOCK- LIMIT LIMIT OUTS SAFETY LIMIT BYPASS 5 4 3 RELAY RELAY 5 AMP SLOWBLOW FUSE SERIES 00 SLAVE 3 +5V SENSOR INPUT TERMINAL OUTPUT 4 MON 4 INPUT VENTSTAT MACHINE TOOL TRANSFORMER OUTPUT NOTE: THE CONTROL OUTPUTS ARE RATED AT 5 AMP EACH. VENTSTAT CONNECTION TO SERIES 00 SLAVE MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project VENTSTAT CONNECTION TO SERIES 00 SLAVE Drawn by Date Distributor Order ID SC /4/0 N/A N/A 0

WADSWORTH R VENT CONTROL SYSTEM MON 3 4 OUTPUT NOTE: THE CONTROL OUTPUTS ARE RATED AT 5 AMP EACH. 3 +5V SENSOR INPUT TERMINAL OUTPUT 4 4 INPUT VENTSTAT MACHINE TOOL TRANSFORMER VENTSTAT CONNECTION TO WADSWORTH 000-R & WADSWORTH 00-R MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project VENTSTAT CONNECTION TO WADWORTH R Drawn by Date Distributor Order ID SC /4/0 N/A N/A

WADSWORTH 000-I WADSWORTH 00-I VENT CONTROL SYSTEM 3 4 5 6 7 6 8 OUTPUT NOTE: THE CONTROL OUTPUTS ARE RATED AT 5 AMP EACH. 3 +5V SENSOR INPUT TERMINAL OUTPUT 4 4 INPUT VENTSTAT VENTSTAT CONNECTION TO WADSWORTH 000-I & WADSWORTH 00-I MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project VENTSTAT CONNECTION TO WADWORTH - I Drawn by Date Distributor Order ID SC /4/0 N/A N/A

WADSWORTH - LST VENT CONTROL SYSTEM MON 3 4 OUTPUT NOTE: THE CONTROL OUTPUTS ARE RATED AT 5 AMP EACH. 3 +5V SENSOR INPUT TERMINAL OUTPUT 4 4 INPUT VENTSTAT VENTSTAT CONNECTION TO WADSWORTH 000-LST & WADSWORTH 00-LST MICRO GROW GREENHOUSE SYSTEMS, INC. 4065 Zevo Dr., Unit B- Temecula, CA 9590 Phone 95.96.3340 Fax 95.96.3350 Project VENTSTAT CONNECTION TO WADWORTH - LST Drawn by Date Distributor Order ID SC /5/0 N/A N/A 3

LIMITED WARRANTY Micro Grow Greenhouse Systems, Inc. warrants that all of the products Micro Grow Greenhouse Systems, Inc. manufactures are free from defects at the time of shipment by Micro Grow Greenhouse Systems, Inc. This warranty covers defects in workmanship and materials. No warranty is extended on any parts, materials, or components manufactured by others and purchased by Micro Grow Greenhouse Systems, Inc., and any warranty on these materials is limited to the warranty supplied by the original manufacturer or supplier of said products only. This warranty excludes any and all damages cause by installation by unqualified individuals, damage by misuse or neglect, shipment damage, alterations to original manufacturing, and improper installation or use for any reason than intended by manufacturer. This warranty may not be altered in any manner except with the written authorization of one the officers or owners of Micro Grow Greenhouse Systems, Inc. The only and sole liability of Micro Grow Greenhouse Systems, Inc. under this warranty is limited to repairing, replacing or the issuance of credit for any products returned to Micro Grow Greenhouse Systems, Inc., during the warranty period of twelve () months from date of shipment. This warranty is specifically conditioned upon Micro Grow Greenhouse Systems, Inc. being notified in writing promptly upon discovery of any product defects by the buyer or end user. The product must then be returned prepaid to Micro Grow Greenhouse Systems, Inc. within the twelve month warranty period for inspection by Micro Grow Greenhouse Systems, Inc. Upon inspection of said product, Micro Grow Greenhouse Systems, Inc. will notify buyer or end user of its findings. At Micro Grow Greenhouse Systems, Inc. sole discretion, the product will be replaced, repaired or a credit will be issued for the original sale price of the product, provided that damage has not occurred due to misuse, neglect, improper use or installation as outlined above, shipping damages or accident. MICRO GROW GREENHOUSE SYSTEMS, INC. SHALL NOT BE LIABLE FOR ANY DAMAGES BEYOND THE ACTUAL ORIGINAL COST OF THEIR PRODUCT EITHER DIRECTLY OR INDIRECTLY ARISING FROM DEFECTIVE PRODUCTS OR WORKMANSHIP. 4