Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

Similar documents
Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, MS-NAE551S-2, NAE Software Release 9.0 Issued August 2017

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

Network Automation Engine

Network Integration Engine Product Bulletin

Network Control Engine Catalog Page

Network Integration Engine

Application and Data Server (ADS) Lite-A System Catalog Page

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

NxE85 Commissioning Guide

Network Control Engine

Network Integration Engine (NIEx9) for Third-Party Integrations Product Bulletin

Metasys N1 Network Integration

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3, MS-NAE5510-2U

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

LCS85 Product Bulletin

Input/Output Module (IOM) Series Catalog Page

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

Field Equipment Controller (FEC) Series Catalog Page Code No. LIT Issued June 2018

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

Advanced Application Field Equipment Controller (FAC) Catalog Page

Metasys For Validated Environments, Extended Architecture Catalog Page

FX Input/Output (I/O) Modules XM07 and XM14

Smart Equipment Controls (SEC)

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued December 2017

Metasys for Validated Environments, Extended Architecture Catalog Page

Medium User Interface (MUI) Version 3

Metasys System Configuration Tool (SCT)

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

FX-PCA Advanced Application Programmable Controller Catalog Page

NIE39/NIE49 Installation Instructions MS-NIE39xx-2, MS-NIE49xx-2

Refer to the QuickLIT website for the most up-to-date version of this document.

Metasys System Extended Architecture Overview

LN Series Remote Input/Output (I/O) Modules

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

TC Modular Series for BACnet Networks

FXVMA Variable Air Volume (VAV) Box Controller

FX40 Supervisory Controller

Application. NAE55 Installation Instructions * S* Installation. Parts included. Materials and special tools needed

TC-9102 Terminal Controller

LX Series Remote Input/Output (I/O) Controller

NCE25 Installation Instructions MS-NCE25xx-x

PEAK TM. SMART Equipment Controllers. Product bulletin

TALON Network Manager- 2 & 6 Express

Metasys System Software Purchase Options Product Bulletin

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

Metasys System Extended Architecture

NAE55/NIE55. Installation Instructions. MS-NAE55xx-x MS-NIE55xx-x. Application. Installation. North American Emissions Compliance.

Web server. Simplified.

Metasys Export Utility Product Bulletin

N2 Dialer Module. Features and Benefits

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

FX06 Field Controller

VMA Programmable VAV Box Controllers Catalog Page Code No. LIT Issued February 2018

What's New for Metasys Release 8.0 Code No. LIT Software Release 8.0 Issued July 2016

Application and Data Server (ADS) Lite-E Catalog Page

Web server. Simplified.

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

Andover ContinuumTM. b3850 Series Terminal Controllers

FX Tools Express Software Package

FX-DIS Local Controller Display Technical Bulletin

Metasys Web Access. Provides full access to M-Alarm for monitoring and acknowledging alarm messages and generating alarm reports

VMA Programmable VAV Box Controllers Catalog Page

DX-9100 Digital Controller, Version 2

TC Compact Series for BACnet Networks

Verasys System Product Bulletin

Issued February 14, 2014 Supersedes June 17, Refer to the QuickLIT website for the most up-to-date version of this document.

Field selectable application type and room module series, via dip-switches on controller

TC Compact Series Unitary Equipment Controller

BCPro System Product Bulletin

Installation Instructions for UL Rev A

Clarity 3 GCE-8000 EMBEDDED IOT CONTROLLER PRODUCT DATA SHEET

Troubleshooting the NAE/NIE

Overview. Applications. Features

Metasys System Software Purchase Options Product Bulletin

FX14 Field Controller

[SmartX Controller ] Introduction. Features. SmartStruxure solution

M-Tool. Features and Benefits System Configuration and Project Management. Allows fast adjustment and commissioning of systems

Issued August 2017 MS-EXPORT-0, MS-EREPORT-0

Industrial PC - VL BPC

ACX Series. Access Controller for Ethernet

Advanced Graphics Application Catalog Page

Extended Digital Controller

Metasys System Direct Connection and Dial-Up Connection Application Note

Metasys System Extended Architecture Glossary

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

Field Advanced Display

P216 Series Condenser Fan Speed Controller

Supervisory Controllers

Metasys System Extended Architecture Overview Technical Bulletin

Savant Host: HST-4501

Wireless Metasys System

Application and Data Server (ADS/ADX) Ready Computer Systems Product Bulletin

Comprehensive User/Group Security Restrict or allow access to myriad of points based on individual or group credentials

Transcription:

MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE8500-0 Code No. LIT-1900195 Software Release 8.1 Issued February 2017 Network Automation Engines (NAEs) provide comprehensive equipment monitoring and control, through key features such as scheduling, alarm and event management, energy management, data exchange, data trending, and data storage. These tools help reduce operation and energy costs for any type of building. This line of NAEs features and leverages IP connectivity and web-based access to Metasys Building Management Systems, including the BACnet protocol, the LONWORKS network, and the N2 Bus protocol, to monitor and supervise a wide variety of HVAC, lighting, security, and fire safety equipment. With the embedded Site Management Portal user interface, NAEs can support multiple concurrent web browser sessions with password and permission access control. To further enhance IT compatibility, NAEs employ standard IT security best practices. NAEs have an embedded UI and the capability to connect to and communicate with cloud-based applications. NAEs support concurrently connected web browsers. Encrypted and trusted communication is now implemented on NAEs that are upgraded to the new release. Private and secure communication is provided by Transport Layer Security (TLS 1.2), which is a protocol that eliminates all clear text communications between Metasys servers, devices, and the browser client. Greater protection from unauthorized users and computer hackers on the Metasys system network is now assured. Specific features of NAE models include the following: NAE55 models support a comprehensive set of supervisory features and functions for large and technically advanced buildings and controllers. NAE35/NAE45 models enable cost-effective NAE connectivity and control in smaller facilities and can increase distribution of control in larger facilities. The NAE85 is a software-only, high-capacity NAE that is designed to provide supervisory level control of Metasys networks that include a large number of BACnet IP devices. Refer to the QuickLIT website for the most up-to-date version of this document. Refer to the Network Engines Product Bulletin (LIT-12012138) for important product application and single point of contact information. Figure 1: NAE55 Network Automation Engine Repair Information If the NAE fails to operate within its specifications, replace the unit. For a replacement NAE, contact the nearest Johnson Controls representative. Features and Benefits Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Allows you to install a system on your existing IT infrastructure within a building or enterprise and use standard IT communication services over the company intranet, WAN, or public Internet with firewall protection. Communication between the NAEs and clients is encrypted with Hypertext Transfer Protocol Secure (https). Web-Based User Interface Allows you to access system data in the NAEs from any supported web browser device connected to the network, including remote users connected by dial-up telephone or an Internet service provider (ISP). Site Director Function Allows you to access all data on one site through one device. The device designated as the Site Director coordinates the display of data from multiple NAE devices for easy navigation through the entire site. Site Management Portal System Configuration Software Embedded in NAE Gives you access to system configuration, monitoring, commanding, diagnosis, and a cloud-based application from any device with web browser software without the need for separate workstation software. User Interface and Online System Configuration Software Embedded in NAE Lets you enable, configure, commission, archive data, monitor, command, and perform system diagnosis from any device by using a web browser, without the need for separate workstation software. Supervision of Field Controller Networks Including BACnet MS/TP, N2 Bus LONWORKS Network, and BACnet IP Devices Supports connectivity to open network standards for complete flexibility in the selection of field devices. Supported protocols include BACnet Master-Slave/Token-Passing (MS/TP), BACnet IP, LONWORKS, and N2 Bus. Multiple Connection Options for Data Access Allow connection of a web browser through the IP network using the Ethernet port. For a dial-up connection, use the optional internal or external modem. 1

Ordering Information Contact the nearest Johnson Controls representative to order an NAE. The following tables list the product code numbers for all available network engines based on model. For network engine accessories, see Table 8. Table 1: NAE35 Ordering Information 1 MS-NAE35xx-x (Base Features of Each NAE35) MS-NAE3510-2 MS-NAE3511-2 MS-NAE3514-2 MS-NAE3515-2 MS-NAE3520-2 MS-NAE3521-2 MS-NAE3524-2 MS-NAE3525-2 NAE35 Network Automation Engines: Requires a 24 VAC power supply. Each model includes one RS-232-C serial port, one USB serial port, one Ethernet port, and an MS-BAT1020-0 Data Protection Battery. Supports a BACnet IP network. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an internal modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; limited to Basic Access support; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; limited to Basic Access support; includes an internal modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. Supports one LONWORKS trunk; includes an additional RS-232-C serial port for optional external modem. Supports a maximum of 64 devices on the LONWORKS port. Supports one LONWORKS trunk; includes an internal modem. Supports a maximum of 64 devices on the LONWORKS port. Supports one LONWORKS trunk; limited to Basic Access support; and includes an additional RS-232-C serial port for optional external modem. Supports a maximum of 64 devices on the LONWORKS trunks. Supports one LONWORKS trunk; limited to Basic Access support; and includes an internal modem. Supports a maximum of 64 devices on the LONWORKS trunks. 1 Some models are also available in Buy American version (add G after the code number). For repair parts, add -702 after the code number (for example, MS-NAE3525-702). Table 2: NAE45 Ordering Information 1 MS-NAE45xx-x (Base Features of Each NAE45) MS-NAE4510-2 MS-NAE4511-2 MS-NAE4520-2 MS-NAE4521-2 NAE45 Network Automation Engines: Requires a 24 VAC power supply. Each model includes one RS-232-C serial port, one USB serial port, one Ethernet port, and an MS-BAT1020-0 Data Protection Battery. Supports a BACnet IP network. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 100 devices on the N2 Bus or BACnet MS/TP trunk. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an internal modem; supports a maximum of 100 devices on the N2 Bus or BACnet MS/TP trunk. Supports one LONWORKS trunk, includes an additional RS-232-C serial port for optional external modem; supports a maximum of 127 devices on the LONWORKS trunk. Supports one LONWORKS trunk, includes an internal modem; supports a maximum of 127 devices on the LONWORKS trunk. 1 Some models are also available in Buy American version (add G after the code number). For repair parts, add -702 after the code number (for example, MS-NAE4521-702). Table 3: NAE55-2 Ordering Information MS-NAE55xx-x (Base Features of Each NAE55) MS-NAE5510-2U NAE55 Network Automation Engines: Requires a 24 VAC power supply. Each model includes two RS-232-C serial ports, two USB serial ports, two RS-485 ports, one Ethernet port, and one MS-BAT1010-0 Data Protection Battery. Supports a BACnet IP network. Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk); supports a maximum of 100 devices on each N2 Bus or BACnet MS/TP trunk. Note: This model is UL Listed, File S4977, UUKL 864-9th Edition Smoke Control Equipment. Also, in order to be UL/ULC compliant, this model must be pre-installed and pre-wired in a standard or custom panel built in the Johnson Controls Reynosa factory. Table 4: MS-NAE551S-2 and Accessories Ordering Information MS-NAE551S-2 MS-NAE551S-702 MS-BAT1010-0 PAN-PWRSP-0 NAE551S-2 Network Automation Engine: Requires a 24 VAC power supply. This model is the hardened, secure version of the standard NAE55 network engine that uses embedded encryption technology and includes an Ethernet port, one MS-BAT1010-0 Data Protection Battery, Delta power supply, power cable, and a reset tool. Supports up to 100 devices on each N2 or BACnet MS/TP trunk. Replacement NAE551S-2. Requires a 24 VAC power supply. This model the hardened, secure version of the standard NAE55 network engine that uses embedded encryption technology and includes an Ethernet port and one MS-BAT1010-0 Data Protection Battery. Supports up to 100 devices on each N2 or BACnet MS/TP trunk. Replacement data protection battery for NAE55 model. Rechargeable gel cell battery with a typical life of 3 to 5 years at 70 F (21 C). 96 VA 120/24 VAC Power Assembly (Transformer, receptacle, 5 A, overcurrent circuit breaker) 2

Table 4: MS-NAE551S-2 and Accessories Ordering Information DRP-24V48W1AZ Delta 24 VDC power supply provided for powering the crypto module in the NAE551S-2. Includes power cable. MS-NAE55SCBL-0 Configuration cable and non-metallic reset probe. Table 5: NAE55-3 1 Ordering Information 2 MS-NAE55xx-x (Base Features of Each NAE55) MS-NAE5510-3 MS-NAE5511-3 MS-NAE5520-3 MS-NAE5521-3 NAE55 Network Automation Engines: Requires a 24 VAC power supply. Each model includes two RS-232-C serial ports, two USB serial ports, two RS-485 ports, one Ethernet port, and one MS-BAT1010-0 Data Protection Battery. Supports up to 100 devices on each N2 or BACnet MS/TP trunk. Supports a BACnet IP network. Supports two N2 or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk). Supports two N2 or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk); includes an internal modem. Supports a LONWORKS trunk and two N2 trunks or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk). Supports up to 255 devices on the LONWORKS trunk. Supports a LONWORKS trunk, and two N2 trunks or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk); includes an internal modem. Supports up to 255 devices on the LONWORKS trunk. 1 This model is only supported for Metasys 7.0.7 or later. 2 Some models are also available in Buy American version (add G after the code number). For the European versions of the NAE55, add an E after the code number. For repair parts, add -703 after the code number (for example, MS-NAE5521-703). Table 6: NXE5xx-x Series Windows Embedded Standard 2009 Image Files MS-NXE5-1WES-10 10 Licenses operating system upgrade from Windows XP Embedded to Windows Embedded Standard 2009 MS-NXE5-1WES-25 25 Licenses operating system upgrade from Windows XP Embedded to Windows Embedded Standard 2009 MS-NXE5-1WES-50 50 Licenses operating system upgrade from Windows XP Embedded to Windows Embedded Standard 2009 MS-NXE5-1SWO-6 Software Only (no licenses) upgrade software for previously purchased software and license part numbers MS-NSE5-1WES-xx Note: These product codes apply to NxE55-1 engines only. They provide a paid license upgrade from the Windows XP embedded operating system to the WES2009 embedded operating system. Table 7: NAE85 Ordering Information MS-NXE85SW-0 1 MS-NXE85SW-6 1 NAE85 or NIE85 (mode is selectable during initial configuration). For new installations/projects. NAE85 or NIE85 (mode is selectable during the initial configuration). For upgrading existing installations/projects. 1 Standard NxE85 models support up to 10,000 objects; an expansion upgrade is available to support an additional 15,000 objects. The NAE85 will display as unlicensed if the object count goes above 25,000. See the NAE Accessories Ordering Information table for more information. Table 8: NAE Accessories Ordering Information MS-BAT1010-0 MS-BAT1020-0 MS-15KUPG-0 MS-MULTENGSW-6 MS-RAP-0 MS-EXPORT-0 AS-XFR100-1 AS-XFR010-1 SC450RM1U (OEM Part No.) Replacement data protection battery for NAE55 and NIE55. Rechargeable gel cell battery: 12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21 C (70 F) Replacement data protection battery for NAE35, NAE45, and NCE25. Rechargeable NiMH battery: 3.6 V 500 mah, with a typical life of 5 to 7 years at 21 C (70 F) 15,000 object expansion upgrade for NxE85 (only one expansion per NxE85) Contains ToggleTunnel utility for converting an NAE55/NIE55 to an NAE55 model with the N2 Tunneling features enabled. Not for use with MS-NAE5510-1U or MS-NAE5510-2U. Ready Access Portal Server provides a user interface that is a natural, complementary extension of the Metasys Site Management Portal user interface. Note: This option is not necessary for sites that have an ADS/ADX that is the Site Director because Ready Access Portal Server is provided with the ADS/ADX solution. Export Utility extracts historical trend, alarm, and audit data from the system and presents the historical data in a variety of formats. Note: This option is not necessary for sites that have an ADS/ADX that is the Site Director because Export Utility is provided with the ADS/ADX solution. Power transformer (Class 2, 24 VAC, 92 VA maximum output), with enclosure Power transformer (Class 2, 24 VAC, 92 VA maximum output), no enclosure Recommended UPS for NxE85 model: APC Smart-UPS SC 450 VA, 280 W, 120 VAC input/output with NEMA 5-15R output connections 3

Technical Specifications Table 9: NAE35 and NAE45 Power Requirement Power Consumption Ambient Operating Conditions Ambient Storage Conditions Data Protection Battery Processor Memory Dedicated nominal 24 VAC, Class 2 power supply (North America), safety extra-low voltage (SELV) power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VAC maximum) 25 VA maximum 0 to 50 C (32 to 122 F); 10 to 90% RH, 30 C (86 F) maximum dew point -40 to 70 C (-40 to 158 F); 5 to 95% RH, 30 C (86 F) maximum dew point Supports data protection on power failure. Rechargeable NiMH battery: 3.6 VDC 500 mah, with a typical life of 5 to 7 years at 21 C (70 F); : MS-BAT1020-0 192 MHz Renesas SH4 7760 RISC processor 128 MB flash nonvolatile memory for operating system, configuration data, and operations data storage and backup 128 MB synchronous dynamic random access memory (SDRAM) for operations data dynamic memory Operating System Network and Serial Interfaces Microsoft Windows Embedded CE 6.0 One Ethernet port; connects at 10 or 100 Mbps; 8-pin RJ-45 connector One optically isolated RS-485 port; 9.6k, 19.2k, 38.4k, or 76.8k baud (depending on protocol); with a pluggable and keyed 4-position terminal block (FC Bus available on NAE351x and NAE451x models only) One LONWORKS port; FTT10 78 Kbps; pluggable, keyed 3-position terminal block (LONWORKS port available on NAE352x-x and NAE452x models only) One RS-232-C serial port with standard 9-pin sub-d connector that supports standard baud rates. A second serial port, on models without an internal modem, that supports an optional, user-supplied external modem. One USB serial port with standard USB connector that supports an optional, user-supplied external modem. Option: One telephone port for internal modem; up to 56 Kbps; 6-pin modular connector (NAE models with an optional internal modem have one RS-232-C serial port only.) Housing Plastic housing material: ABS polycarbonate UL94-5VB Protection: IP20 (IEC 60529) Mounting Dimensions (Height x Width x Depth) Shipping Weight Compliance On flat surface with screws on three mounting clips or a single 35 mm DIN rail 131 x 270 x 62 mm (5-3/16 x 10-5/8 x 2-1/2 in.) Minimum space for mounting NAE35 and NAE45: 210 x 350 x 110 mm (8-3/16 x 13-13/16 x 4.-5/16 in.) 1.2 kg (2.7 lb) United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment, UL Listed, FIle S4977, UUKL 864-9th Edition, Smoke Control Equipment(MS-NAE35x0-2U and MS-NAE45x0-2U models only) FCC Compliant to CFR47, Part 15, Subpart B, Class A Canada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada Compliant, ICES-003 Australia and New Zealand: RCM Mark, Australia/NZ Emissions Compliant Europe: CE Mark Johnson Controls declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive. BACnet International: BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Building Controller (B-BC) Table 10: NAE55xx-3 and NIE55xx-3 Power Requirement Power Consumption Ambient Operating Conditions Ambient Storage Conditions Data Protection Battery Clock Battery Processor Memory Dedicated nominal 24 VAC, Class 2 power supply (North America), SELV power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VAC maximum) 50 VA maximum 0 to 50 C (32 to 122 F); 10 to 90% RH, 30 C (86 F) maximum dew point -40 to 70 C (-40 to 158 F); 5 to 95% RH, 30 C (86 F) maximum dew point Supports data protection on power failure. Rechargeable gel cell battery: 12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21 C (70 F); : MS-BAT1010-0 Maintains real-time clock through a power failure. Onboard cell; typical life 10 years at 21 C (70 F) 1.46 GHz Intel Atom Bay Trail E3815 processor for MS-NAE55xx-3 models 16 GB flash nonvolatile memory for operating system, configuration data, and operations data storage and backup for MS-NAE55xx-3 models. 2 GB DDR3 SDRAM for operations data dynamic memory for all models Operating System Johnson Controls OEM Version of Microsoft Windows Embedded Standard 7 with SP1 (WES7) 4

Table 10: NAE55xx-3 and NIE55xx-3 Network and Serial Interfaces One Ethernet port; 10/100/1,000 Mbps; 8-pin RJ-45 connector Two optically isolated RS-485 ports; 9,600, 19.2k, 38.4k, or 76.8k baud; pluggable and keyed 4 position terminal blocks (RS-485 terminal blocks available on NAE55 models only) Two RS-232-C serial ports, with standard 9-pin sub-d connectors, that support all standard baud rates Two USB 2.0 serial ports; standard USB connectors support an optional, user-supplied external modem Options: One telephone port for internal modem; up to 56 kbps; 6-pin RJ-12 connector One LONWORKS port; FTT10 78 Kbps; pluggable, keyed 3-position terminal block (LONWORKS port available on NAE552x-x models only) Housing Plastic housing with internal metal shield Plastic material: ABS + polycarbonate; Protection: IP20 (IEC 60529) Mounting Dimensions(Height x Width x Depth) On flat surface with screws on four mounting feet or on dual 35 mm DIN rail 226 x 332 x 96.5 mm (8.9 x 13.1 x 3.8 in.) including mounting feet Minimum space for mounting: 303 x 408 x 148 mm (12.0 x 16.1 x 5.8 in.) Shipping Weight Compliance 2.9 kg (6.4 lb) United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment, FCC Compliant to CFR47, Part 15, Subpart B, Class A Canada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal Equipment, Industry Canada Compliant, ICES-003 Europe: CE Mark - Johnson Controls declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive. Australia and New Zealand: RCM Mark, Australia/NZ Emissions Compliant BACnet International: BTL 35-2004 Listed B-BC Table 11: NAE85 Software System Recommendations for Installation/Upgrade Product Code MS-NXE85SW-0: NAE85 software for up to 10,000 objects (new projects only software) Recommended Computer Platform Intel Xeon E5506, 2.13 GHz, 4 MB Cache 2 x 160 GB 7.2K, 8.9 cm (3.5 in.) Cabled 3 Gbps, RAID 1 configuration with add-in SAS6/iR (SATA/SAS Controller) Recommended Memory Hard Disk Supported Operating Systems and Software 2 GB RAM minimum 160 GB minimum Windows Server 2012 R2 Editions with Update 1 Windows Server 2012 Editions Windows Server 2008 R2 Standard and Enterprise Editions with SP1 Windows Server 2008 R2 Web Edition with SP1 Note: The NAE85 software requires two Windows components: Microsoft.NET Framework Version 3.5 SP1 and Microsoft.NET Framework Version 4.6.1. Supported Operating Systems for Metasys Client Computers Windows 10 Professional or Enterprise (64-bit) Windows 8.1 Pro and Windows 8.1 Enterprise Editions (64-bit) Windows 7 Professional, Enterprise, and Ultimate Editions with SP1 (32-bit or 64-bit) Apple OS X 10.8 Mountain Lion Apple OS X 10.9 Mavericks Apple OS X 10.10 Yosemite Apple OS X 10.11 El Capitan Note: Apple operating systems are supported for Metasys client computers only. Note: In Apple OS X, you cannot view Graphics+ graphics in the Site Management Portal UI. Internal Optical Drive Recommended Antivirus Software DVD ROM, SATA Symantec Endpoint Protection Version 12 5

Table 11: NAE85 Software System Recommendations for Installation/Upgrade Supported Web Browser Software for Metasys Client Computers Windows Internet Explorer version 11 Note: In Internet Explorer 11, select the Use Microsoft compatibility lists option, found under Tools > Compatibility View Settings, to ensure that websites appear and function correctly. Apple Safari version 8.0 and 9.0 (Other browsers, such as Google Chrome and Mozilla Firefox, may also be used but are not fully supported.) Note: You use the web browser to download the Launcher application. After you install the Launcher application, you use the Launcher, not the web browser, to log in to Metasys Site Management Portal (SMP) UI. Supported Virtual Environments Network Communication Recommended Data Protection Microsoft Hyper-V, VMware Network Interface: 1 Gbps Ethernet network interface card connects at 10 Mbps, 100 Mbps, or 1 Gbps (100 Mbps or better recommended) UPS for NxE85 model: APC Smart-UPS SC 450VA, 280 W, 120 VAC input/output, National Electrical Manufacturers' Association (NEMA) 5-15R output connections, OEM Part No. SC450RM1U The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. Building Technologies & Solutions 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls. All other marks herein are the marks of their respective owners. 2017 Johnson Controls Published in U.S.A. www.johnsoncontrols.com 6