ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Similar documents
LCD Readout Digital Pressure Switch

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

The dual display means that the current value and the threshold value, it makes direct setting of threshold value

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

panasonic.net/id/pidsx/global

Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Head-separated Digital Pressure Sensor For Gas DP5 SERIES DPH SERIES. High speed response of 1/1,000 sec. High speed response 1 ms

Series Pressure Sensor Instruction Sheet

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I

Type Pressure range description Part number

Multi Channel Pressure Sensor Controller Operation Manual PSE200 Series

Inductive Proximity Sensor

Series Pressure Sensor Instruction Sheet

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

Suitable for detecting transparent films or transparent bottles

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

Mini Photoelectric Sensor

Thread length (overall length) material

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

the Interactive Catalog

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Vane Type Photoelectric Switches with Self-contained Amplifier

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

High Pressure E/P Regulator. ITVH Series

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

The importance of the static electric control is put on confirming the actual status.

Cylindrical Proximity Sensor

Chemical Resistant Inductive Prox

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

PRD/PRDW Series. Long Distance Type

GB MIX COMUNICAZIONE - MI. Digital Electro-pneumatic Regulator ER Series

Compact Inductive Proximity Sensor

Installation and Maintenance Instructions for GC31 Ultra-Compact Digital Pressure Sensor

Digital pressure sensor

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

NA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS.

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Thread length (overall length)

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

E2Q4 Square Proximity Sensor

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

Optimum sensing capability for LCD manufacturing

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

U-shaped Type/Convergent Reflective Type. onlinecomponents.com

Inductive Proximity Sensor

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

-ment Ambient humidity 35 to 95%RH, Storage :35 to 95%RH

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Capacitive Proximity Sensor E2K-C

Electronic pressure switch with display Model PSD-4

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Photoelectric Sensors E3F2

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

02/11/2015

Inductive Proximity Sensor

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Photoelectric Sensor with Built-in Amplifier with New Connector Options E3Z

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Dual 3-color display makes operation easier!

BGS (at min. setting) BGS (at max. setting)

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

Pressure sensors SPAN

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Pile Driver Weld Immune Sensors

One step ahead in performance and mounting ease

E2K-X4ME1 2M E2K-X4ME2 2M

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

COMPACT FLOW RATE CONTROLLER FCM SERIES CC-793A 7

standard, short, preferential, top

Miniature Inductive Prox TL-W

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Transcription:

Stainless steel diaphragm SUS630 and SUS304 are used for wetted parts. For General Purpose Fluids With Backlight Digital Pressure Switch Series ZSE5B (For vacuum) ISE5B (For positive ) Leakage rate: 1 X 10-4 atm cc/s The sensor section and fitting are electron beam welded. This switch can be used with liquids and gases. Two independent outputs Allows the calibration of 2 different setpoints, e.g. change of vacuum pad size requiring different setpoints, or two different supply s requiring different confirmation points. Choice of display units Display units can be easily selected and changed, making these switches globaly acceptable. Vacuum Positive mmhg kpa PSI kgf/cm 2 bar MPa PSI kgf/cm 2 bar Variety of switch output modes Hysteresis mode Window comparator mode P2 P1 (Standard) P1 P2 (Standard) n2 n1 (Reversed) n1 n2 (Reversed) For use in various fluid applications Hydraulic fluid Silicon oil Lubrication oil Dry air Carbon dioxide Ammonia Drain-containing air Argon Nitrogen gas Freon Exact detection of atmospheric (For vacuum) Atmospheric can be detected after vacuum release is applied. Calibration data The calibration data is stored in an EEPROM. The EEPROM is rated to keep its memory for 100,000 hours (approx. 11 years) even without power supplied. Panel mounting available A special adaptor permits panel mounting. 3.3-1

With Backlight Digital Pressure Switch ZSE5B/ISE5B How to Order Positive ISE5B L Vacuum ZSE5B L PSE ZSE4 ISE4 ZSE5 ISE5 Port size 02 R(PT) 1 /4 T2 NPTF 1 /4 Note) M5 X 0.8 (Female) threaded. Lead wire length L 3m ZSE6 ISE6 ZSE3 ISE3 GS PS Output specifications 26 Analog output (1 to 5V) 27 NPN Open collector/2 outputs(sinking) 67 PNP Open collector/2 outputs (Sourcing) ISA ZSE1 ISE1 ZSE2 ISE2 Panel mount adaptor No. (Panel adaptor A + Panel adaptor B + Mounting bracket) ZS-22-E Panel adapter A ZS-22-03 Panel adapter B ZS-22-02 Mounting bracket ZS-22-03 ZS-22-D (With four M3 mounting threads) Bracket (Optional) ZSP IS ZSM PF IF Panel adaptor A Panel adaptor B Mounting bracket 3.3-2

ZSE5B/ISE5B Specifications Model Operating range Max. kpa MPa mmhg Min. display unit kgf/cm 2 PSI bar Indicator light Frequency response (1) Hysteresis mode Hysteresis Window comparator mode Fluid Temperature characteristics Repeatability Supply voltage Output specification Current consumption Error display Pressure display Self-diagnostic function Operating temperature range Noise resistance Voltage resistance Insulation resistance Vibration resistance Shock resistance Lead wire Weight Port size Protective construction Vacuum ZSE5B Positive ISE5B 0.1 to 1MPa 1.5MPa 0.01 0.1 1 0.1 Fluid that will not corrode SUS304 and SUS630 ± 3% F. S. or less ± 1% F. S. or less 12 to 24V DC (Ripple ± 10% or less) NPN open collector 30V, 80mA or less PNP open collector 80mA or less 45mA or less Red light blinks. Display the error code on LCD 3 1/2 digits (10mm-size numerals) Over current (2), Over, Data error, Pressure during 0 clear 0 to 50 C (No condensation) 500Vp-p, Pulse width: 1µS, Standing: 1nS Between external terminals and housing 250V AC, 50/60Hz for 1 min. Between external terminals and housing 2MΩ (50V DC by megameter) 10 to 500Hz Pulse width 1.5mm or acceleration 98 m/s 2 (at smaller vibrations) in X, Y, Z directions (2 hours) 980 m/s 2 in X, Y, Z directions (3 times for each direction) Grommet oil-resistant vinyl cabtire code 26 ø3.4 0.2mm 2 3 core 3m 27, 67, ø3.5 0,14mm 2 4 core 3m 126g (including 3m-long lead wire) 02: R(PT) 1/4, M5 X 0.8 T2: NPTF1/4, M5 X 0.8 IP40 Note 1) Hysteresis mode: ZSE: When the values of P1 and P2 are the same or when P1>P2 within 2 digits, the hysteresis will be automatically 2 digits for the set value of P1. ISE: When the values of P1 and P2 are the same or when P1>P2 within 3 digits, the hysteresis will be automatically 3 digits for the set value of P1. Window comparator mode: ZSE: The hysteresis is 2 digits, so separate P1 from P2 by 5 digits or more and set them. ISE: The hysteresis is 3 digits, so separate P1 from P2 by 7 digits or more and set them. 1 digit is the minimum display unit. (See the table above.) Note 2) Analog output has no overcurrent detection function. Description 100 to 100kPa 200kPa 2 10 0.02 0.2 0.02 : When Green LED(OUT1) or Red(OUT2) turns on 200Hz (5ms) Adjustable (2 digits or more) Fixed (2 digits) Adjustable (3 digits or more) Fixed (3 digits) 3.3-3 UP key Increases / set point value. Switched to peak mode high. LED (Green) Displays OUT1 operation condition. RE key Reset the switch by pressing the UP and DOWN buttons simultaniously. Clears anomaly. Displays "0". RE MPa LCD Displays present. Displays / set point value. Displays error code. Displays unit. DOWN key Decreases / set point value. Used for switch to peak mode low, unit change and output mode change. LED (Red) Displays OUT2 operation condition. Blinks on and off when an error occurs. key Changes the mode. Used for unit change and output mode change by pressing the button for at least 1 second.

With Backlight Digital Pressure Switch ZSE5B/ISE5B Calibration Procedure Procedure Initial setup 1. Initial setup mode 2. Selection of "Display unit" 3. Selection of "OUT1 output mode" Press the button "S" for at least 1 second. "1.3" is displayed and the display blinks. Table 1 SMC Note) Note) "1.3" is a program version of micro computer. Initial setup Calibration Normal operation Select "Display unit" and "Output mode". RE Output mode OUT1 OUT2: Same as OUT1. RE RE RE "Output mode" is Press the button "S" By pressing the entered by button "S", the pressing the calibration is button "S". completed. Select "Display unit" by pressing the button. For High Select "Output mode" by pressing the button. : Normal mode Select "Output mode" by pressing the button. : Normal mode MPa PSI kgf/cm 2 bar : Reversed output mode : Reversed output mode For Low ( Refer to Table 1.) ( Refer to Table 1.) mmhg kpa PSI kgf/cm 2 bar P Output mode n SMC Note) > = > = Calibrate set point for switch output. YES NO YES NO SMC P-2 P-1 Pressure/Vacuum up H P-1 P-2 Pressure/Vacuum up n-2 n-1 Pressure/Vacuum up H n-1 n-2 Pressure/Vacuum up H H Measured, displayed, switch operation occurs. 4. Selection of "OUT2 output mode" SMC Hysteresis mode H (Fixed hysteresis) =2 digits(zxse5b) or 3 digits(ise5b) Window comparator mode Hysterersis mode H (Fixed hysteresis) =2 digits(zse5b) or 3 digits(ise5b) Window comparator mode PSE ZSE4 ISE4 ZSE5 ISE5 ZSE6 ISE6 ZSE3 ISE3 GS PS ISA ZSE1 ISE1 ZSE2 ISE2 ZSP IS ZSM PF IF 3.3-4

RE ZSE5B/ISE5B Calibration Procedure Calibration 1. Calibration value input mode 2. Input set point value for OUT1 (1) 3. Input set point value for OUT1 (2) mmhg RE Press the button "S". RE button: Increase set point value button: Decrease set point value Refer to the Table 2 when using in vacuum. "OUT1(2) mode" is entered by pressing the button "S". RE button : Increase set point value button : Decrease set point value 4. Input set point value for OUT2 (1) 5. Input set point value for OUT2 (2) "OUT2(1) mode" is entered by pressing the RE button "S". button: Increase set point value button: Decrease set point value "OUT2(2) mode" is entered by pressing the button "S". button: Increase set point value button: Decrease set point value By pressing the button "S", the calibration is completed. Table 2 Vacuum ZSE5 calibration. The setting range for ZSE5 is 100kPa to 100kPa. Take notice that the setting method is different from the positive type. 1. Hysteresis mode <Ex.> When switched at more than 50kPa and Hysteresis is 10kPa. Set P1 at 40kPa and P2 at 50kPa. P2: P1: 50kPa 40kPa Negative 0 Positive Note) Pressure must be P1>P2. Note) Set the hysteresis more that 2 digits. "Digit" is the minimum setting unit of the. 1 digit 2kPa, 10mmHg, 0.02kgf/cm 2, 0.2PSI, 0.02bar Standard output Reversed output Relation between and switch output 2. Window comparator mode <Ex>. When switched at 30kPa to 70kPa. Set P1 at 70kPa and P2 at 30kPa. Note) Hysteresis is automatically set by 2 digits in case of window comparator mode. Negative P1: 70kPa -66kPa 66kPa P2: 30kPa 34kPa -34kPa 0 Positive Standard output Reversed output Relation between and switch output 3.3-5

RE With Backlight Digital Pressure Switch ZSE5B/ISE5B Other Functions Error Codes Peak Mode High Peak Mode Low RE Reset Function RE Internal Circuit and Wiring Lead wire colors inside ( with IEC standards. "-26" Analog Output Type 1 to 5V(±5%F.S.) impedance : 1kΩ or more To display the high peak (highest degree of vacuum), press the UP button during normal operation. The LCD displays "H". To return back to normal operation press the UP button again. To display the low peak (lowest degree of vacuum), press the DOWN button during normal operation. The LCD displays "L". To return back normal operation, press the DOWN button again. Simultaneously pressing the UP and DOWN button will reset the switch. 1) Reset will cause the following during normal operation: Peak high is cleared. Peak low is cleared. Zero is reset. 2) Reset will cause the following when error has occurred: Switch will assume normal operation (all calibration data has retained). In case of data error, reset the setup mode and then switch will assume normal operation. Note) Reset Function does not work during setup mode. ) are those prior to comformity Main circuit LED (Green) LED (Red) Brown DC (+) (Red) Black OUT(Analog output) (White) Blue DC (-) (Black) + 12 to 24V DC Error codes Display Cause Solution (1) (1) q Calibration was changed by accident, reason unknown. Output 1 output current is exceeding 80mA. Output 1 (Black wire) could be shorted out. Output 2 output current is exceeding 80mA. Output 2 (White wire) could be shorted out. Max. operating has been exceeded for more than 2 seconds.1.5 x MAX. operating press.for switch 0.5MPa for vacuum switch Pressure is 2% above rated during 0 clear. Note 1) Do not apply to Analog output type. Construction Push Up and Down buttons to reset all the data. Turn off the power and verify the load connected output 1. Verify that the output is not shorted out and then reset the switch. Turn off the power and verify the load connected output 2. Verify that the output is not shorted out and then reset the switch. Reduce the supply to below the max. rating and then reset the switch. Apply atmospheric and then reset the switch. w t PSE ZSE4 ISE4 ZSE5 ISE5 ZSE6 ISE6 ZSE3 ISE3 GS PS ISA ZSE1 ISE1 ZSE2 ISE2 ZSP IS ZSM PF IF "-27" NPN Open Collector Max.30V, 80mA Residual voltage:1v or less Main circuit LED (Green) LED (Red) Brown DC (+) (Red) Max.80mA Black OUT1 (White) Max.80mA White OUT2 (Yellow) Blue DC(-) (Black) + 12 to 24V DC e y "-67" PNP Open Collector Max.80mA Main circuit LED(Green) LED(Red) Brown DC (+) (Red) Black OUT1 (White) Max.80mA White OUT2 (Yellow) Max.80mA Blue DC (-) (Black) + 12 to 24V DC r Parts List No. q w e r t y Description Indicator panel Body Seal Lead wire Pressure sensor Fittings Materials Denatured PPO PBT NBR Vinyl chloride (Vinyl sheath) SUS630 SUS304 3.3-6

ZSE5B/ISE5B Precautions Be sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instructions common precautions on the products mentioned in this catalog, and refer to p.3.0-7 to 3.0-9 for more detailed precautions on every series. Warning qvoltage resistance Voltage resistance between metal fitting and lead wire of the switch is 250V. Do not apply voltage potential in excess of 250V. Caution qwhen induction noise is expected to be generated from piping, ground the piping. Warning qquality of operating fluid Section in contact with fluid are made of SUS630 ( sensor) and SUS304 (fitting). Use fluid that will not corrode these materials. The corrosion resistance of SUS630 and that of SUS304 are almost the same. For reference, fluid and gas that will not corrode SUS304 are shown below. Dry air Drain-contained air Hydraulic fluid (JIS-K2213) Silicon (JIS-K2213) Lubrication (JIS-K6301) Freon Carbon dioxide Ammonia Nitrogen gas Chlorine gas Wiring Pressure Source Caution qpanel mounting Others qinsert Adaptor A from the front of panel. wfix Adaptor A firmly with Adaptor B from the back of panel. einsert a switch to Adaptor A from the back of panel. rfix the switch with a mounting bracket. Panel adaptor A Panel adaptor B Pressure switch Mounting bracket 3.3-7

With Backlight Digital Pressure Switch ZSE5B/ISE5B Dimensions Standard 30 39 4-ø2.7 6.5 deep 20 Sensor SMC Welded part 53.5 8.5 30 02:R(PT) 1 / 4 T2:NPTF 1 / 4 RE 3000 Lead wire length 17 12.3 20 5 M5 X 0.8 5 deep Fitting PSE ZSE4 ISE4 ZSE5 ISE5 ZSE6 ISE6 ZSE3 ISE3 GS With bracket 50 40 30 4-ø4.5 28 (44) 39 PS ISA ZSE1 ISE1 SMC ZSE2 ISE2 30 20 ZSP 53.5 RE IS 8.5 Bracket ZS-22-D 3000 Lead wire length 12.3 17 28 Panel mount 41.8 40 Panel adaptor A ZS-22-03 Cutout dimensions for panel mount (41.6) 4.3 36 36 +0.5 0 SMC 58.5 40 36 +0.5 0 ZSM PF IF Mounting bracket ZS-22-04 RE Panel adaptor B ZS-22-02 Thickness of panel: 1 to 3.2mm 3.3-8