MONSOON Software Design & Status

Similar documents
Requirements, Software Architecture & Design

MONSOON Data Handling System Interface Status and Data Stream Transfer

MONSOON Generic Pixel Server Communications, Command/Response and Data Stream Interface Description

MONSOON. PAN Run-time Configuration, Setup and Operating Mode Definition Interface Description. NOAO Document ICD 5.1 Revision: 1.

MOSAIC Operations Concept Document

The MONSOON Implementation of the Generic Pixel Server

SAMI software description

MONSOON. TORRENT DHE PSM TSM INTERFACE DESCRIPTION Interface Control Document 7.6 NOAO Document TRNT-AD Version: 0. Authored by: Peter Moore

MONSOON Master Control Board Test Procedures

MONSOON Torrent Production Readiness Review

Mosaic 1.1 Final Design Review

The Mosaic Data Capture Agent

MONSOON IR Acquisition Board Test Procedures

Automated Software Configuration in the MONSOON System

2MASS Observer s Guide. Steward Observatory 61 Kuiper Telescope

Teledyne Imaging Sensors SIDECAR ASIC Development Kit & Focal Plane Electronics

MONSOON. TORRENT DHE Architecture. DHE Architecture Document NOAO Document TRNT-AD Revision: 5.0

Chiron GUI User's Manual. CTIO 60 inches Chiron CHI60S 1.2. La Serena, Jan Chiron User's Manual / CTIO 60 inches Chiron CHI60S 1.

D R A F T ICD 1.8/4.4. Target Acquisition System to Telescope Control System. Bret Goodrich, Eric Hansen. Version: Draft A2. Issued By: Software Group

Hera-B DAQ System and its self-healing abilities

200" LFC Test and Checkout (Rev )

Silicon Imaging SI-2K DVR Operator s Manual

High Resolution Camera Software User s Manual. SOAR Adaptive Module (SAM)

Client Installation and User's Guide

Controller Command Description

predefined elements (CI)

Client Installation and User's Guide

NOCTURN XL: Getting Started. For Win 7 Evaluation GUI Version February 21, 2013 Frisco, Texas

Task 2: TCP Communication

User Manual PDUTracker

The NEWFIRM Observing Software: From Design to Implementation. Copyright 2008 Society of Photo-Optical Instrumentation Engineers

User Manual. Admin Report Kit for IIS 7 (ARKIIS)

Installing a Virtual Machine Using an ISO Image

Lab - Manage Virtual Memory in Windows 7 and Vista

Distributed Control Systems at SSRL Constraints for Software Development Strategies. Timothy M. McPhillips Stanford Synchrotron Radiation Laboratory

CTIO 60 inches Echelle ECH60S 2.2. Administrator's Manual. Software Architecture. La Serena, May 2010

Distributed Control System Overview

Exporting and Importing a Virtual Service Blade

Voodoo Detector Control Program User's Manual

ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2

2008 JINST 3 S Online System. Chapter System decomposition and architecture. 8.2 Data Acquisition System

Comp 204: Computer Systems and Their Implementation. Lecture 18: Devices

GIANO: The Graphical User Interface Manual

Application Notes for Configuring Tri-Line TIM Plus with Avaya IP Office Delta Server - Issue 1.0

AVT Vimba. AVT Vimba User Guide for Linux Jun-25 V1.2. Allied Vision Technologies GmbH Taschenweg 2a D Stadtroda / Germany

NGUI: The NEWFIRM Graphical User Interface

Preparing to Install Components

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual

DataMan. version 6.5.4

Department of Computer Science and Technology

Devices. Today. Comp 104: Operating Systems Concepts. Operating System An Abstract View 05/01/2017. Devices. Devices

Set Up Automatic System Restore Point Windows

GOLD SERIES DVD/CD Duplicator Manual

REAL TIME OPERATING SYSTEM PROGRAMMING-II: II: Windows CE, OSEK and Real time Linux. Lesson-9: WCE Serial Communication, Network, device-to

GigE Vision Cameras. Key Features. Dimension (Unit : mm) Pin map (H/W Rev 2.0 이상 ) LED Indicator. back Pannel. Download (File name)

MiniDAQ1 A COMPACT DATA ACQUISITION SYSTEM FOR GBT READOUT OVER 10G ETHERNET 22/05/2017 TIPP PAOLO DURANTE - MINIDAQ1 1

DR. IR. J.L. RUEDA TORRES LAB INSTRUCTORS:

1. Introduction. Outline

5907-VL CD / DVD Tower Operator s Guide

ExpressCluster for Linux Version 3 Web Manager Reference. Revision 6us

Appliance Guide. Version 1.0

HARPS-NEF ELECTRICAL SYSTEMS. Tom Gauron

Graphics Performance Benchmarking Framework ATI. Presented to: Jerry Howard. By: Drew Roberts, Nicholas Tower, Jason Underhill

Status and future of beamline control software at ESRF. Beamline Control Unit

GigE Vision camera featuring the Sony IMX273 CMOS sensor

CCD Acquisition Function

VREDPro HPC Raytracing Cluster

Manta G-040. Description. GigE Vision camera featuring the Sony IMX287 CMOS sensor. Benefits and features:

Oracle SOA Suite VirtualBox Appliance. Introduction and Readme

Functional Specification

Opera Web Browser Archive - FTP Site Statistics. Top 20 Directories Sorted by Disk Space

DVD Duplication Towers

Mark 6: design and status update

tekdxfxsl FibreXtreme I/O Interface

Conformance Statements for MIR CTN Applications

Manual Version: V1.15. Device Management Software User Manual

Course AZ-100T01-A: Manage Subscriptions and Resources

IronSync File Synchronization Server. IronSync FILE SYNC SERVER. User Manual. Version 2.6. May Flexense Ltd.

Step-by-step guide for the libradtran virtual machine. A) Installation

GigE Vision camera featuring the Sony IMX287 CMOS sensor

CALICE-DAQ software. Tao Wu. CALICE Collaboration Meeting Prague, 11-13/Sep/2007

NAM 6.3(2) Image Contents Upgrading to NAM 6.3(2) Verifying NAM 6.3(2) Image Installation Known Issues in Release 6.3(2)...

Troubleshooting CHAPTER

CCS Support for I&T and Data Flow

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Intel CoFluent Studio in Digital Imaging

Installing a Virtual Machine Using an ISO Image

THE NEW GENERAL CONTROLLER - NGC/OPT. Claudio Cumani Instrumentation SW Workshop , October 7

LinX Software Suite v3 Getting Started

IBM Single Sign On for Bluemix Version December Identity Bridge Configuration topics

Heavy Photon Search Data Acquisition

Best Practices for Deployment of SQL Compliance Manager

Installing or Removing Connections for the DECAM Monsoon Front End Crates

Micro-PWC Personal Work Center PW6000

OVERDRIVE Quick Start Guide. v.1.0

Error code. Description of the circumstances under which the problem occurred. Less than 200. Linux system call error.

Chapter 11: Input/Output Organisation. Lesson 15: Standard I/O bus PCI

Common Configuration Options

CMOS USORIA. Features

University of Valencia - FTP Site Statistics. Top 20 Directories Sorted by Disk Space

Transcription:

MONSOON Software Design & Status 1

Contents Review of Software System Architecture Interfaces and Libraries PAN Process Architecture and Status Documentation and Testing Status Schedule and Resources To-Do list for MONSOON To-Do list for NEWFIRM 2

Review of Software System Architecture 3

MONSOON Pixel Server SUPERVISORY NODE LINUX PC MSL (MONSOON Supervisory Level PIXEL ACQUISITION NODE 1 Ethernet Link 100Mb/s PIXEL ACQUISITION NODE 2 Ethernet Link 100Mb/s PIXEL ACQUISITION NODE 3 Ethernet Link 100Mb/s 10Mb/s Ethernet LINUX PC PCI FIBER CARD 1Gb/s Fiber (50Mpixel/s) DETECTOR HEAD ELECTRONICS NODE 1 SYNC 10Mb/s Ethernet 1Gb/s Fiber (50Mpixel/s) LINUX PC PCI FIBER CARD DETECTOR HEAD ELECTRONICS NODE 2 SYNC 10Mb/s Ethernet 1Gb/s Fiber (50Mpixel/s) LINUX PC PCI FIBER CARD DETECTOR HEAD ELECTRONICS NODE 3 N NODES CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA CCD or FPA 4

MONSOON Level 0 Context Monsoon System Context Diagram Client System (Engineering Lab Console) (Level 0) Science Client System (Instrum ent Control System) (Observation Control System) Local Status Interface Df1.1 Command String Connection Df1.2 Response String Connection ICD 4.0 GPX Interface ICD 4.1 MONSOON Restrictions (TBD) 1.0 Supervisor Layer Df1.3 Asynchronous Status Con nection TBD Df1.4 Pixel Data Stream Local DHS Interface Df1.5 Status Data Connection ICD 5.0 PPX Interface 2.0 PAN System Df1.4 Pixel Data Stream MONSOON GPX (Pixel Server) ICD 6.0 Generic DHE ICD 6.1 MONSOON DHE 3.0 DHE System Fits Image on Disk External Entity or Process Interface Definition Label Data Flow 1.0 2.1 Internal Process Df 1.1 Data Flow Label MONSOON External Process 5

Three Layer System Architecture 1. MONSOON Supervisor (MSL) Layer. 2. Pixel Acquisition Node (PAN) Layer. 3. Detector Head Electronics (DHE) Layer. 6

Three Layer System Architecture (cont) 1. MONSOON Supervisor Layer. (MSL). A command/control Layer, (no pixel data). Provides GPX interface to clients. Provide single point contact to system. Provides client access security. Provides multiple client connections. Provides error monitoring & recovery. Handles Command/response to/from multiple PANs. May run remotely or on a PAN. 7

Three Layer System Architecture (cont) 2. Pixel Acquisition Node (PAN) Layer. No knowledge of other PAN-DHE pairs. Provides PPX interface to MSL or users. Provides run-time configuration of PAN/DHE. Provides first level data archiving. Provides multiple image processing modes.» Fowler Sampling, coadds, MSR techniques, OT imaging. Provides parameter verification/control/help. Deals with IR/OUV/etc. differences. 8

Three Layer System Architecture (cont) 2. Pixel Acquisition Node (PAN) Layer (cont). 2. Handles single exposure sequencing. Handles raw data pre-processing. processing. Provides interface to DHE hardware. Provides DHE sequencer configuration/download. Provides PAN error monitoring/reporting/recovery. Provides support for speed ROI. Provides support for compression ROI s. 9

Three Layer System Architecture (cont) 3. Detector Head Electronics (DHE) Layer. 3. Handles array hardware control.» Voltage levels, sequencing, monitoring. Handles integration timing. Handles detector readout sequencing. Handles digital averaging. Handles shutter control. Can handle array temperature control. Board Self Identification and Version tracking. 10

Interfaces and Libraries 11

Interface Definitions Client System to Generic Pixel Server. ICD 4.0 Generic Pixel Server - Communications, Command/Response and Data Stream Interface Description. (GPX). MONSOON Restrictions on Science Client Access. ICD 4.1 MONSOON Command and Parameter Restriction Lists. Developed in conjunction with Science Team. Supervisor Layer to Pixel Acquisition Node. ICD 5.0 Generic Pixel Acquisition Node Communications, Command & Response Description. (PPX). PAN to Generic DHE (Detector Controller) (Detector Controller). ICD 6.0 Generic Detector Head Electronics - Command and Data Stream Interface Description. (A Command Interface). MONSOON PAN to MONSOON DHE. NICD 6.1 MONSOON Detector Head Electronics - Command and Data Stream Interface Description. (Hardware/Software Interface Details). Published interface 12

Interfaces and Software Layering Science or Engineering Clients ICD 4.0 Generic Pixel Server - Communications, Command/Response and Data Stream Interface Description Supervisor Layer Software ICD 5.0 PAN Pixel Node - Communications, Command/Response & Data Stream Interface Description Pixel Acquisition Node Software ICD 6.0 Generic Detector Head Electronics Command and Data Stream Interface Description Communications to Simulator ICD 6.1 MONSOON DHE Interface & Design ICD 6.2 SDSU-II DHE Interface & Design ICD 6.99 Other DHE Interface & Design ICD 6.1 MONSOON DHE Interface & Design MONSOON DHE Interface Software SDSU-II DHE Interface Software OTHER DHE Interface Software Systran Fiber Drivers SDSU-II Fiber Drivers OTHER Fiber Drivers Systran Fiber Hdwr SDSU-II Fiber Hdwr OTHER Fiber Hdwr Simulated MONSOON Detector Head Electronics MONSOON Detector Head Electronics ICD 7.0 MONSOON Backplane SDSU-II Detector Head Electronics OTHER Detector Head Electronics 13

Monsoon Layers and ICD's MONSOON GPX Image Acquisition system ICD and Software Layer relationship Monsoon Supervisory Layer Monsoon PAN Interface Layer Monsoon DHE Utility Library (libdheutil) Monsoon DHE Hardware Library (libmonsoon) Monsoon Com Utility Library (libcomutil) Monsoon Com Hardware Library (libsystran) Systran SL240 Drivers (libfxslapi) Pixel Acquisition Node Pixel Acquisition Node Systran SL240 Hardware Monsoon DHE (Detector Head Electronics) (ICD 4.0 GPX) (ICD 5.0 PPX) (ICD 6.0 Generic DHE) (ICD 6.1 MONSOON DHE) (Com Util Library API) (Com Hdw Library API) (FXSL Library API) General Status Not started In Testing Complete (in use) Complete (in use) Complete (in use) Complete (in use) Complete (in use) COTS (Complete) COTS Hardware NOAO/CTIO Hdw NEWFIRM Status Not Needed In Testing Complete (in use) Complete (in use) Complete (in use) Complete (in use) Complete (in use) COTS (Complete) COTS Hardware NOAO/CTIO Hdw 14

General Functionality Libraries All complete and either in test or in use now libcmdcfgutil- runtime configuration to specific detector. libcliutil- command line interface; parse, search & help. libqueutil - queue functions; new, add, remove, full, empty. libsemutil - semaphore functions; new, init, give, take, release libshmutil - shared memory functions; attach, detach libsockutil - socket functions; new, listen, accept, read, write libmiscutil - a set of routines used by many pan processes. 15

Generic Interface Libraries Complete and in use now (no changes needed for NEWFIRM) LibppxUtil - the PAN pixel server interface routines. (ICD 5.0). LibdheUtil - generic DHE interface routines (ICD 6.0). libcomutil - generic communications link routines. libpanutil - shared memory setup & init used by PAN processes. 16

Hardware Specific Libraries Complete and in use now (no changes needed for NEWFIRM) libsystran. Implements the SL240 specific interface to the com link. libmonsoon. Implements the MONSOON DHE access routines (ICD 6.1). 17

Focal Plane Specific Libraries libdetcmnds. Implements routines unique to a detector/instrument. Implements OUV, IR, Guider, etc. differences. Integration Time Calculations, ROI checking & setup, Unique Array Initialization & Setup requirements. OTI details, charge/image shift commands, etc. User Function name to C function translation provided.» Same structure as runtime command configuration.» Translation compiled into library. Shared Library loaded at run time.» One Library for each unique detector/instrument combination.» Library loaded from detector/instrument directory. 18

libdetcmnds. Focal Plane Specific Library STATUS libgeneric - version complete and in test. libaladdin_iii - version complete and in use. liborion_ii - version complete and ready for test. liborion_ii_2x2 - version needed for NEWFIRM in work.» No changes over ORION_II version foreseen at this time libota - version in design phase. libccd - version for single CCD testing similar to generic 19

PAN Process Architecture and Status 20

PAN Layered Process Architecture libppx - Generic Pan Interface ICD 5.0 PanDaemon Socket interface and CLI to command processor High level DHE control Pan Process Startup and shutdown Process control for Pan processes Error checking and recovery PAN process Command or Semaphore access Data or data dddress flow path Shared memory access Shared Memory Interface fsaver (FITS Writer) pancapture panprocalg pansaver exttrgger libdheutil - Generic DHE Interface ICD 6.0 libmonsoon - Monsoon DHE hardware interface ICD6.1 libcomutil - generic communications link routines libsystran - systran versions of communications link interface libfxslapi - Systran Sl240 Driver Well defined API's 21

pandaemon Pan Process Status ICD 5.0 - ppx interface complete and tested. ICD 6.0 - generic DHE interface - complete and tested. ICD 6.1 - MONSOON DHE interface - complete and tested. DHE/PAN Attribute access routines complete and in test.» All currently used routines are tested.» Additional routines may need testing/modification.» Attribute array code complete and in test. pandaemon interface to pancapture tested in dhehdwdbg. Pan process startup routines still in coding. 22

pancapture Pan Process Status (cont) Data capture interface» ICD 6.0 - generic DHE interface - complete and tested.» ICD 6.1 - MONSOON DHE interface - complete and tested. DHE/PAN Attribute access routines complete. pancapture interface to buffer queues written and in test. pancapture data capture routines tested in dhehdwdbg. pancapture automated process startup still in coding. 23

panprocalg Pan Process Status (cont) Data processing interface» ICD 6.0 - generic DHE interface - complete and tested.» ICD 6.1 - MONSOON DHE interface - complete and tested. DHE/PAN Attribute access routines complete. panprocalg interface to buffer queues written and in test. panprocalg data processing routine tested in dhehdwdbg. panprocalg automated process startup still in coding. 24

pansaver Pan Process Status (cont) DHE/PAN Attribute access routines complete. pansaver interface to buffer queues written and in test. pansaver image save routine tested in dhehdwdbg. pansaver automated process startup still in coding. pansaver Header info creation not yet coded. Final image publication scheme to NEWFIRM DHS not finalized. 25

Software Documentation Status System Architecture document in work. Software ICD s s (4.0, 5.0, 6.0, 6.1) Published. Some modification/rewrite needed to match actual interface. Library API Published. Maintained with Source code - Some modification/rewrite will be needed to match recent changes Process description documentation begun. Using source code Documentation system for processes. Manually produced text used to detail process interactions. Queues and Semaphores described in added text. 26

Test & Verification Status General function libraries complete and tested. in individual test program and in pandaemon. Generic interface libraries complete and tested. in individual test program and in pandaemon. Many also tested in dhehdwdbg. Hardware specific libraries Currently libraries are being used in dhehdwdbg.» ALADDIN_III library tested with dhehdwdbg on actual array» Generic/CCD library tested with pandaemon.» ORION_II library tested with pandaemon.» ORION_II_2x2 library in coding. 27

Test & Verification Status (cont) In PAN process system. All Processes verified against functional description. All processes are compiled and in test. Processes being tested against GEMINI DEWAR. Automated Process startup still in coding. 28

Schedule & Resources Libraries tested & running in dhehdwdbg (May `03) Generic Interface Libraries General Utility Libraries Hardware Specific Libraries» libsystran, libmonsoon Detector Specific Libraries» generic, ALADDIN_III - (DONE)» ORION_II - ready for testing.» ORION_II_2x2 - in coding (same as ORION_II) (DONE) (DONE) (DONE) PAN Interface & processes running DHE (Sept `03) PPX interface Library (DONE) 29

Schedule & Resources (cont) TCL/TK Engineering Client First functionality (Sept. 03) (DONE) Scripts, auto-configuration, auto GUI setup, etc in work Everything Needed for NEWFIRM (Nov `03) liborion_ii - ready for test (Completion Jan 03) liborion_ii_2x2 - in coding (Completion Jan 03) Configuration files» ORION_II_2x2.arr» ORION_II_2x2.cfg - constructed with hardware» ORION_II_2x2.ucd - sequencer code file - Multi-Pan system development starting (DONE) in work in work (Apr 04) 30

To-Do List for MONSOON Still to be done for General MONSOON Pan process coordination testing (3 MW) Automated startup routines/scripts (2 MW) ROI s, single-array readout, added Error Handling, added Simulation capabilities, runtime process control (restart, reset, new algorithm load), etc. (?? MW) Handling for CCD detector details. (?? MW) Complete Engineering Client functionality (4 MW) 31

To-Do list for NEWFIRM Still to be done for NEWFIRM (assuming a single PAN Detector specific library testing Detector specific library testing w/arrays Configuration files testing -» ORION_II_2x2.arr» ORION_II_2x2.cfg - constructed with hardware» ORION_II_2x2.ucd - sequencer code file - (assuming a single PAN-DHE pair) Setup & Observing MODE files - Creation and Testing» To be done by NEWFIRM scientists and engineers.» Some recoding may be needed Integration and testing with NEWFIRM Client DHS interface routines (2 MW) (1 MW) (DONE) (0.5 MW) (2 MW) (2 MW) (2 MW) (4 MW) 32