Submittal Data Sheet WAGO Node for itm

Similar documents
Submittal Data Sheet intelligent Touch Manager DCM601A71

I/O Expansion Module Installation & Reference

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

intelligent Touch Manager

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

XT-9100 Technical Bulletin

FX Input/Output (I/O) Modules XM07 and XM14

iologik 4000 Series (M) Modules

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS INTELLIGENT TOUCH MANAGER ONE FOR ALL ADVANCED MULTI-ZONE CONTROLLER

PGR-3200 MANUAL INSULATION MONITOR

Features and Benefits. Certifications

Redundant System Redundant System P9-1-1

intelligent TOUCH MANAGER ONE FOR ALL ADVANCED MULTI-ZONE CONTROLLER

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

WAGO MODULAR IP67 I/O SYSTEM

Time Counters mini "h", DC Version

File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Remote I/O Product Specification

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

Remote I/O Product Specification

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

S800 I/O ABB Automation

Daikin HVAC Controls Guide Specification

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

Moxa TCC-100 Series Hardware Installation Guide

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

iothinx 4500 Series (45MR) Modules

SEL-2411 Programmable Automation Controller

SAI Active Universal Pro

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Overvoltage Protection

EtherCAT Slave. EtherCAT Data Transition. EtherCAT Tool: TwinCAT. Taiwan Pulse Motion Co.,Ltd

MCX08M2 Programmable controller

General information. Display. Supply voltage. Input current

APS SCALE SERIES DIMENSIONS

SEL-2414 Transformer Monitor

Analog Input Modules. 4 Inputs

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

RS485 MODBUS Module 8AO

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Lighting Control Panel

Technical specification

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

TM3TI8T module TM3-8 inputs temperature

Introduction. General Ratings

TAKING IT TO THE EXTREME, 750 XTR THE WAGO-I/O-SYSTEM FOR EXTREME APPLICATIONS

GS202 Encoder Switch

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Features and Benefits. Certifications

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

RS 485 Mini Modbus 1AO

USER S MANUAL Power Supply for Backplane Vdc

Switched Mode Power Supply Operating manual PAP800

Multi-Point Gas Detection and Control System

16-Channel Digital Input Termination Card 24Vdc

IndraControl S67. Fieldbus coupler PROFINET

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

General information. Display. Supply voltage. Input current

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

General information. Display. Supply voltage. Input current. Encoder supply. Output current

EMS467 Monitoring System. Installation and Operations Manual Section 40

General information. Display. Supply voltage. Input current

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

TCP A3. Description. Module with 3 thermocouple inputs. Datasheet

Gas Controller System DGC-06

General information. Display. Supply voltage. Input current

Moxa TCC-100 Series User s Guide

900EN Series. Acromag RUN ST DIO STATUS ACT LINK DFT RST ETHERNET TB1

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

Click Desktop Kit. Click Desktop Kit

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

AI561 Analog Input Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System

VersaMax IP I/O Module

Multi-Point Digital Gas Detection and Control System

Suprex RS-485 SPX-7500 Wired Reader-Extender

General information. Display. Supply voltage

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power

Printview: End module for internal data bus extension - Item No.:

TM3TI4 module TM3-4 inputs temperature

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Transcription:

The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via manual control, interlock, scheduling and remote access using itm touch screen or web access. Integration scheme WAGO Node Features Monitoring/Control of ancillary equipment: a) Digital Input b) Digital Output c) Analog Input d) Analog Output Interlock Function a) Creates interlocks among sensors (CO2, Humidity, Temperature), ancillary equipment, and/or indoor units at the itm. b) High/Low Limit Alarms configurable for CO2, Humidity, and Temperature. Schedule Function a) Up to 20 schedule events per day can be set for the ancillary equipment at the itm Web Access a) All the ancillary equipment can be monitored and controlled through web access function of the itm. Easy installation a) Din rail mount Standard width 1.38 (35mm)

System Capacity itm Management points limitation a) Up to 512 total contact points can be connected b) A total of 650 points which includes Daikin indoor unit groups and WAGO contact points can be connected c) Up to 30 nodes can be connected WAGO node points limitation d) Up to 120 contact points per node Up to 1640 ft. wiring length to the farthest WAGO node from the itm Specifications Basic Kit Part # Characteristics Image (dimension W x H x L) Bus Coupler (750-315/xxx-xxx 2 ) MODBUS (RS485) Communication, 24VDC input (2.01 x 2.56 x 3.94 ) Basic Kit (required for each Node 1 ) (Total width 4.45 ) 51291052 End Module (750-600) The module is used to terminate the internal bus of a Node. Fieldbus Connector (750-960) D-Sub male connector: 9 pin, 2 horizontal wire entries, one input and one output (0.47 x 2.52 x 3.94 ) 24 VDC Power Supply (787-712) Input voltage 110 240VAC, output voltage 24VDC @ 2.5A (1.97 x 3.62 x 5.35 ) Note: 1. A Maximum of 120 contacts can be connected to one node. 2. The part numbers may vary depends on versions.

750-479 3 I/O Module 1 Part Number Characteristics 2 Image (dimension W x H x L) 2 Channel DI 750-400 2 Channel Digital Input Module, 24 VDC, 3 power Digital 4 Channel Digital Input Module, 24 VDC, 2 power 4 Channel DI 750-432 Input 8 Channel DI 750-430 8 Channel Digital Input Module, 24 VDC, 2 power 750 513/000 2 Channel Digital Output Module, no power jumper 2 Channel DO Digital 001 contact Output 4 Channel Digital Output Module, 24 VDC, 2 power 4 Channel DO 750-504 750-454 2 Channel Analog Input Module, 4 20 ma, Differential Inputs, no power jumper contact 2 Channel AI Differential Measurement Input, no power jumper 2 Channel Analog Input Module, ± 10 VDC, contact Analog 750 461/020 000 2 Channel Analog Input Module, NTC 20k Ohm, no power jumper contact Input 4 Channel Analog Input Module, 4-20 ma, singleended, 2 power 750-455 4 Channel Analog Input Module, 0-10 VDC, singleended, 2 power 750-459 4 Channel AI 4 Channel Analog Input Module, NTC 20k Ohm/ 750-464/020-000 4 NTC 10k Ohm, configurable, 2 power jumper contacts (0.47 x 2.52 x 3.94 ) 2 Channel Analog Output Module, 4 20 ma, 2 750-554 power 2 Channel AO 2 Channel Analog Output Module, 0-10 VDC, no 750-550 Analog power jumper contact Output 4 Channel Analog Output Module, 4-20 ma, 2 750-555 power 4 Channel AO 4 Channel Analog Output Module, 0-10 VDC, 2 750-559 power 24 VDC Bus Power Supply Module, Required for use Internal System Power 750-613 after every 32 contact points connected in a node, 3 Supply power Passive Power Supply 750 602 24 VDC Power Supply Module, passive, 3 power Wiring Field Supplied 2-conductor Shielded copper cable 24AWG Up to 1640 ft.

* Note: 1. All sensors are field supplied. 2. A module with less power shall be placed after modules with more power. Otherwise, 750-602 is needed to supply power to the module with more power. 3. For 750-479 (2 Channel Ai ± 10 VDC), only range 0-10VDC can be used with itm. 4. 750-464/020-000 is not compatible with the bus coupler 750-315/000-002 (kit part number 51291052). Schematics Basic Kit - Part # 51291052 Bus Coupler (750-315) Connector (750-960) 24V DC Power Supply (787-712) End Module (750-600)

Wiring itm and WAGO node Wiring 24VDC Power supply

2 Channel Di 750-400 4 Channel Di 750-432 8 Channel Di 750-430 2 Channel Do 750-513/000-001 4 Channel Do 750-504

Error Error Shield Shield 2 Channel Ai (4-20 ma) 750-454 2 Channel Ai (± 10 VDC) 750-479 2 Channel Ai (20k Ohm) 750-461/020-000 4 Channel Ai (4-20 ma) 750-455 4 Channel Ai (0-10 VDC) 750-459 4 Channel Ai (NTC 10/20k Ohm) 750-464/020-000

2 Channel Ao (4-20 ma) 750-554 2 Channel Ao (0-10 VDC) 750-550 4 Channel Ao (4-20 ma) 750-555 4 Channel Ao (0-10 VDC) 750-559