Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Similar documents
Section 4 Ground-Fault Protection Devices

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

MOTOR PROTECTION CIRCUIT BREAKERS

ic60n RCBO 30 ma IEC , IEC , AS/NZS

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Pan assemblies and installation accessories

Prisma Plus System P Cubicles up to 4000 A

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

DSE201, DSE201 M Compact design with enhanced protection

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

IEC & 2 standard. The reference for safe and reliable LV switchboards

The right solution for every home

Compact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

ict contactors EN 61095, IEC 1095 Interference

C60 multi-standard range

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Build electrical installations more efficiently. Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

ARA Automatic Recloser

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

60103 Circuit Breaker

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

RB60 RANGE. Miniature circuit breakers

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Description. Installation. Power supply

SIRCO Load break switches for power distribution from 125 to 5000 A

1492-SP Supplementary Protectors

LV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Compact NSX communication

Motor protection circuit breakers

3RV1 Circuit-Breakers

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

RATINGS AND SPECIFICATIONS

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Redline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2

Multi 9 switchgear NSA, INS, NG125

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Motor protection relays

Manual source-changeover systems Possible combinations

Source-changeover systems Presentation

TeSys IEC Contactors and Overload Relays

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Horizontal distribution busbar HX 3 80/125 A plug-in

Low Voltage Catalogue Compact NS. Circuit breakers and switch-disconnectors from 630b to 3200 A

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Pragma. Doors reference if necessary. references. In perfect harmony. + customiser

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

MV Network Switchgear, Protection and Control

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

the Santon FCS-type switch Disconnect Superior Switch Solutions

Reinforced discrimination

RM4TR31 three-phase network control relay RM4-T - range V

VIP 40/45 VIP 400/410

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Communication COM option in Masterpact

Thermal-Magnetic Circuit Breaker 2216-S

MULTI 9 System Catalog

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Motor protection circuit breakers

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Circuit Breakers Type CTI 25M, CTI 45MB

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Miniature Circuit-Breaker IEC Series 8562

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

RM4TA32 three-phase network control relay RM4-T - range V

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Disconnect Switches. Safe Switching and Disconnecting

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Mini Contactors & Overloads

TeSys contactors From 115 to 2750 A

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

RW-E. Overloads. Solid-State Overload Relays. Standard Features

4. CIRCUIT BREAKERS. Functional Emergency Switching

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Low Voltage electrical distribution Catalogue Prisma PH

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Control and signalling units Ø 16 monolithic Harmony XB6 E. Catalogue May

Transcription:

Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010

NG160 circuit breaker Ready to install

NG160 General contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection C-1 Additional characteristics D-1 Catalogue numbers E-1 556E1000.indd version: 1.3

Presentation NG160 circuit breaker Incomer for modular panels Mounting on a DIN rail The NG160 circuit breaker and its installation system were specially designed for the incomer function in modular switchboards. The result meets the need for a ready to install device offering highquality mounting and wiring characteristics. Vigi earth-leakage protection module for side-by-side mounting Earth-leakage protection is widely used on the switchboard incomer function. Mounting of a Vigi module alongside the incomer optimises enclosure space and leaves more room for other modular devices and instruments in the same row. The new rigid cables for the Vigi module reduce connection errors and avoid tightening problems during mounting. version: 1.3 556E1000.indd

45 mm cut-outs for modular mounting plates The NG160 front escutcheon complies with the 45 mm standard. This means the NG160 and Multi 9 switchgear can be mounted on the same DIN rail with all the fronts aligned. New raisers for depth adjusters for Multi 9 The raiser is used to fit an elevator DIN rail to compensate for the difference in depth between the NG160 and Multi 9 devices. The new design ensures greater rigidity for the devices on the DIN rail. Electrical continuity between the two rails for earthing purposes is provided by a metal insert on the depth adjuster. 556E1000.indd version: 1.3 3

NG160 circuit breaker Quick installation! DIN mounting plate already on the device The Compact NG160 circuit breaker comes with its mounting plate already secured to the device. The NG160 is ready to install right from its package. Two-position clip for fast mounting on a DIN rail The circuit breaker and Vigi module mounting plates are equipped with two-position clips that can be opened and closed for easy mounting. Just open the clip with a screwdriver, place the NG160 in the desired position and close the clip to secure the device to the DIN rail. Built-in connectors for cables up to 70 mm2 The Compact NG160 circuit breaker is supplied with its aluminium tunnel terminals. They are designed for both Cu and Al cables with stripped ends or ferrules. In this way, wiring is ready to install. version: 1.3 556E1000.indd

New DIN rail with adjustable support The new DIN rail support specially designed for incoming devices instantly adapts the DIN rail to the desired depth. The engraved depth indications ensure correct positioning of NG160, NS160 and NG125 devices. The reinforced rigidity of the rail and its securing system ensure reliable mounting. Distribution systems for connection to Powerclip busbars The new distribution systems for Prisma Plus switchboards and enclosures were designed for fast and totally safe connection of NG160 and NG125 incoming devices and Interpact switch-disconnectors. One-piece prefabricated cable assemblies can be used for connection to the busbars and to Distribloc or Polybloc Multiclip distribution blocks to supply rows of Multi 9 breakers. The space under the rail is sufficient for the measurement CTs. 556E1000.indd version: 1.3

NG160 circuit breaker Operating safety Breaking via a double contact To increase limiting of the fault current, each pole of the NG160 circuit breaker has a double fork-shaped contact. This design splits the arc and significantly reduces the forces exerted during a short-circuit. This ensures the integrity of installations in enclosures. Cascading with Multi 9 circuit breakers Thanks to its very high current-limiting capacity, the NG160 offers excellent cascading and discrimination with downstream Multi 9 breakers. This means Multi 9 devices can have breaking performancies lower than the prospective short-circuit current, thus reducing their cost. Vigi earth-leakage protection module with direct tripping If a residual-current fault occurs, the Vigi module of the NG160 acts directly on the tripping mechanism of the breaker via a mechanical link (no need to add a release coil). This solution avoids any risk of non-tripping due to poor connections. 6 version: 1.3 556E1000.indd

Vigi earth-leakage protection module with rigid cables for optimum positioning in the toroid The power cables are perfectly centred in the Vigi toroid to ensure precise measurement of the residual current and avoid risks of nuisance tripping. This solution ensures optimum continuity of service for the installation. 556E1000.indd version: 1.3

NG160 circuit breaker Super-immunised protection Earth-leakage protection based on "si" technology The earth-leakage protection function is mandatory to protect life and property, but can be affected by disturbed environments, such as: > high-frequency currents with low rms values > voltage surges caused by atmospheric phenomena such as lightning > opening and closing of capacitive circuits. These disturbances often cause nuisance tripping of residual-current devices leading to installation down-time costs. Thanks to the "si" (super immunised) technology, the Vigi NG160 guarantees operation of the earth-leakage protection only if there is a real risk. Operating safety in severe environments (to -25 C) Operation of the Vigi NG160 is not affected by low temperatures down to -25 C. version: 1.3 556E1000.indd

Consistent design of the Schneider Electric low-voltage system Pragma New range of modular enclosures The new range of Pragma enclosures combines functionality, robustness and attractive design, offering installers a complete solution for protection, control and distribution installations up to 960 A. They are available in flush-mount and surface-mount versions, with a capacity of 24 modules. Their are especially well-suited for installations in the commercial sector. Prisma Plus G Wall-mount and floor-standing enclosures up to 630 A The Prisma Plus G range was designed for all types of wall-mount and floor-standing enclosures up to 630 A for commercial and small industrial applications. All the enclosure components, modular DIN-rail devices and installation and connection systems contribute to fast and easy construction of Prisma Plus G enclosures. Prisma Plus P Functional system up to 3200 A Prisma Plus P high-power switchboards are the best solution for demanding installation and safety requirements. The perfect fit between the Prisma Plus P system, the low-voltage devices and the specially tested prefabricated connection solutions guarantees a safe and high-performance electrical installation. 556E1000.indd version: 1.3 9

10 version: 1.3 556E1000.indd

NG160 Functions and characteristics Presentation 2 Characteristics of NG160 circuit breakers and switch-disconnectors 0 Incomer for modular switchboards A-2 Accessories for NG160 circuit breakers and switch-disconnectors 0 Incomer for modular switchboards A-3 Installation recommendations B-1 Dimensions and connection C-1 Additional characteristics D-1 Catalogue numbers E-1 556E2000TDM.indd version: 3.3 A-1

Functions and characteristics Characteristics of NG160 circuit breakers and switch-disconnectors 0 Incomer for modular switchboards 3 and 4 pole circuit breakers and switch-disconnectors specially designed for use upstream of Multi 9 modular devices: b reinforcement of breaking capacities of downstream devices by cascading up to 25 ka b easy installation in Pragma or Prisma Plus type G enclosures: v standard 45 mm front cut-out v clip-on installation on a DIN rail v reduced depth (82.5 mm). NG160 circuit breaker Electrical characteristics as per IEC 60947-2 Rated current (A) Rated insulation voltage (V) Rated impulse withstand voltage (kv) Rated operational voltage (V) In Ui Uimp 40 C 160 800 8 Ue AC 50/60 Hz Ultimate breaking capacity (ka rms) Icu Service breaking capacity Suitability for isolation Durability (C-O cycles) Ics 500 E 25 16 10 8 75 % b 10000 5000 Type of circuit breaker Protection PB103512-SE-40 220/240 V 380/415 V 440 V 500 V % Icu mechanical electrical (In -440 V) Built-in thermal-magnetic trip unit In Ratings Ir Thermal protection Magnetic protection AC 50/60 Hz lm 16 25 32 40 fixed threshold 50 600 600 600 600 600 N 40 25 16 10 100 H 50 36 22 15 63 80 125 160 800 800 1000 1250 1250 NG160NA switch-disconnector Electrical characteristics as per IEC 60947-3 PB103530-SE-58 NG160 circuit breaker. Conventional thermal current (A) Rated insulation voltage (V) Rated impulse withstand voltage (kv) Rated operational voltage (V) Rated operational current Ith Ui Uimp 40 C 160 800 8 Ue Ie Short-circuit making capacity lcm AC 50/60 Hz AC 50/60 Hz 220/240 V 380/415 V 440/480 V 500 V (ka peak) min. for switchdisconnector alone max. with protection by upstream circuit breaker (A rms) 1s 3s 500 AC22A 160 160 160 160 2.1 Short-time withstand current Icw Suitability for isolation AC23A 160 160 160 125 330 1500 1500 b Coordination between circuit breakers and switch-disconnectors The switch-disconnector must be protected against downstream short-circuits. The choice of the right switch-disconnector therefore depends on coordination with the protective device installed upstream. The table below indicates the maximum short-circuit current in karms for which the switch-disconnector is protected by coordination with the circuit breaker located upstream. Important: the switch-disconnector must be protected against overloads. The rating of the switch-disconnector must be greater than or equal to that of the upstream circuit breaker. Upstream protection NG160NA downstream Isc max 380-415 V Making capacity Isc max 440 V Making capacity ka rms ka peak ka rms ka peak NR100F NS100 - NS160 NR160F N SX H 25 52 20 42 70 154 65 143 36 75 35 73 50 105 50 105 Installation and connections Connections Connectors Bare cables from 1.5 to 70 mm² cables Dimensions (mm) WxHxD NG160 NG160 with Vigi Weight (kg) Device Device + Vigi module NG160 in modular enclosure. A-2 version: 5.3 3P 4P 3P 4P 90 x 120 x 82.5 120 x 120 x 82.5 210 x 120 x 82.5 240 x 120 x 82.5 3P 4P 3P 4P 1.1 1.4 2.6 2.9 Width in 9 mm modules 10 14 24 27 556E2000.indd

Accessories for NG160 circuit breakers and switch-disconnectors 0 Incomer for modular switchboards PB103521-SE-58 Earth-leakage protection : add-on Vigi module Can be installed on the right side of the circuit breaker or switch-disconnector. Two versions allow connection of outgoing circuits to the top or bottom of the Vigi module to meet installation requirements. Characteristics as per IEC/EN 60947-2 annex B Number of poles Sensitivity (A) Time delay + add-on Vigi module. PB101693_SE_50 NG160 3, 4 0.03 / 0.3 / 1 / 3 intentional (1) (ms) 0 60 150 max. break time < 40 < 140 < 150 Rated voltage (V) 50/60 Hz 200 to 440 V Reset pushbutton Test pushbutton Protection against nuisance tripping b DC-component withstand class A (1) If the sensitivity is set to 30 ma, there is no time delay, whatever the time-delay setting. DB116841 In In Out PB101691_SE_50 DB116840 Prefabricated incoming connections to Vigi module for top or bottom outgoing connections Out 556E2000.indd version: 5.3 A-3

Accessories for NG160 circuit breakers and switch-disconnectors Functions and characteristics 0 DB125773 Incomer for modular switchboards Auxiliaries and accessories Terminal shield Available auxiliaries include: b 1 ON/OFF indication contact (OF) b 1 trip-indication contact (SD) b 1 voltage release (MN undervoltage release or MX shunt trip) b 1 extended rotary handle with door locking, allowing operation of the device from outside the enclosure. Din rail and raiser Depth adjuster This accessory is required to align the front of Multi 9 devices when they are. installed next to a NG160. Maximum length 342 mm (36 modules). Extended rotary handle 60E NG1 Ui 750 V 15 V Uimp Auxiliary contacts OF and SD 8 kv 16 ka Icu 380/4 Icu (ka) 25 Ue (V) 40 16 220/2 15 10 380/4 440 Icu 75% cat A Ics = Hz 50/60 IEC / EN AS UNE -2 60947 VDE NEMA UTE push to trip CEI BS...Ø8 NSØ5...5/16 13/64 Toggle locking Rotary handles Distribution connectors ON I tripped 5...8 reset Voltage releases O OFF Degree of protection: IP55, IK08. This handle makes it possible to operate circuit breakers installed inside switchboards, from the switchboard front. It maintains: b suitability for isolation b indication of the three positions O (OFF), I (ON) and tripped b access to trip unit settings, when the switchboard door is open b circuit breaker locking capability in the OFF position by one to three padlocks, shackle diameter 5 to 8 mm (not supplied). The door cannot be opened if the circuit breaker is ON or locked. The extended rotary handle is made up of: b a unit that replaces the front cover of the circuit breaker (secured by screws) b an assembly (handle and front plate) on the door that is always secured in the same position, whether the circuit breaker is installed vertically or horizontally b an extension shaft that must be adjusted to the distance between the back of the circuit breaker and the door, between a minimum of 185 mm and a maximum of 600 mm. Terminal shield NG160. PB103527-SE-40 Toggle locking using a removable device The circuit breaker can be locked in OFF position by fitting a removable accessory on the toggle. This locking system complies with the isolation requirements of IEC 60947-2. One to three padlocks can be used, with shackle diameters from 5 to 8 mm. Locking accessory. A-4 version: 5.3 556E2000.indd

PB101696_13 PB101697_23 Indication contacts. MX or MN voltage release. Electrical auxiliaries b OF contact (open/closed): indicates the position of the circuit breaker contacts b SD contact (trip indication) indicates that the circuit breaker has tripped due to: v an overload v a short-circuit v an earth fault v operation of an MX or MN voltage release. The SD contact returns to de-energised state when the circuit breaker is reset. Standard contacts Rated thermal current (A) 6 Utilisation category (IEC 60947-5-1) AC12 AC15 Operational current (A) 220/240 V 6 4 380/440 V 6 2 b MX shunt release. Trips the circuit breaker when the control voltage rises above 0.7 times the rated voltage. Control signals can be of the impulse type (u 20 ms) or maintained. b MN undervoltage release This release trips the circuit breaker when the control voltage drops below a tripping threshold: v tripping threshold between 0.35 and 0.7 times the rated voltage v circuit breaker closing is possible only if the voltage exceeds 0.85 times the rated voltage. A time delay unit for the MN release eliminates the risk of nuisance tripping due to a transient voltage dip lasting y 200 ms. Operation When the circuit breaker has been tripped by an MN or MX release, it must be reset locally. MN or MX tripping takes priority over manual closing. In the presence of a standing trip order, closing of the contacts, even momentarily, is not possible. Remote tripping Characteristics MN MX Power supply V AC 50/60 Hz 24 V, 48 V, 110/130 V, 220/240 V, 380/415 V, 440/480 V V DC 24 V, 48 V, 110-125 V, 250 V Operating threshold 0.85 to 1.1 Un 0.7 to 1.1 Un Consumption (pick-up/hold) < 5 VA < 5 VA Response time < 50 ms < 50 ms Connection cable diameter 1.5 mm² max 1.5 mm² max DB114695 Wiring diagram D1 C1 92 94 12 14 OF Trip unit MN (1) MX SD D2 C2 91 11 (1) MN or MX (MN: D1, D2 ; MX: C1, C2). 556E2000.indd version: 5.3 A-5

A-6 version: 5.3 556E2000.indd

NG160 Installation recommendations Presentation 2 Functions and characteristics A-1 NG160 connection and installation in switchboards 0 B-3 Modular devices Installation in Prisma Plus wall-mountand floor-standing enclosures B-4 Dimensions and connection C-1 Additional characteristics D-1 Catalogue numbers E-1 556E2100TDM.indd version: 1.1 B-1

B-2 version: 1.1 556E2100TDM.indd

Installation recommendations NG160 connection and installation in switchboards DB114691 DB108155 Connections NG160 devices come with built-in bare-cable connectors as standard. They can be tightened with a 4 mm male spanner. The distribution lug can be used to connect 3 small-size cables. E54545 Standard device With distribution lug Rating (A) 16 to 125 160 16 to 160 L (mm) 18 y 10 S (mm²) rigid 1.5 to 70 10 to 70 1.5 to 16 Cu / Al flexible 1.5 to 50 10 to 50 1 to 10 (1) Tightening torque 5.6 8.5 2 (Nm) (1) Flexible cables from 1.5 to 4 mm²: connection with crimped or self-crimping ferrules. DB114692 Connection by cables. A1 Distribution lug for 3 cables. Safety clearance When installing a circuit breaker, minimum distances (safety clearances) must be maintained between the device and panels, bars and other protection devices installed nearby. These distances, which depend on the ultimate breaking capacity, are defined by tests carried out in accordance with standard IEC 60947-2. DB116843 D1 DB116844 Front panel NG160 Voltage Dimensions (mm) Insulation, insulated bars or painted sheetmetal Bare sheetmetal F (1) C1 D1 D2 C1 D1 D2 A1 B U y 440 V 0 30 30 5 35 35 10 0 (2) 0 (2) For NG160 with terminal shield mounted. The mandatory distances when installing NG160 circuit breakers are calculated from the device case, not taking into account the terminal shields. D2 C1 Temperature derating When the ambient temperature is greater than 40 C, overload-protection characteristics are slightly modified. To determine tripping times using time/current curves, use Ir values corresponding to the thermal setting on the device, corrected for the ambient temperature (see tables below). Bare or painted sheetmetal ; insulation or insulated bars (1) If F < 8 mm: insulating screen is mandatory. Minimum distance between the circuit breaker and top bottom or side panels and front or rear panels. B NG160 Rating (A) 40 C 45 C 50 C 55 C 60 C 65 C 70 C 16 16 15.6 15.2 14.8 14.5 14 13.8 25 25 24.5 24 23.5 23 22 21 32 32 31.3 30.5 30 29.5 29 28.5 40 40 39 38 37 36 35 34 50 50 49 48 47 46 45 44 63 63 61 60 58 56 54 52 80 80 78 77 75 73 72 70 100 100 98 96 93 91 89 86 125 125 123 120 118 116 113 111 160 160 157 153 150 146 142 139 NG160NA 160 160 156 153 146 143 140 Power dissipation (in Watts) 3/4 poles Rating (A) Fixed circuit breaker P/pole Additional power Vigi (N, L3) Vigi (L1, L2) NG160 16 4 0.06 0.06 25 5 0.16 0.16 32 5.5 0.26 0.26 40 6 0.4 0.4 50 7 0.63 0.63 63 8 1 1 80 9 1.6 1.6 100 10 2.5 2.5 125 12.5 3.9 3.9 160 15.4 6.4 6.4 NG160NA 160 15.4 556E2100.indd version: 1.1 B-3

Installation recommendations Modular devices Installation in Prisma Plus wall-mount and floor-standing enclosures DB114711 DB114711 DB114712 NG160 circuit breaker NG125, C120 circuit breaker INS40/160 switch-disconnector Device No. of vertical modules Adjustable modular rail (1) NG125 circuit breaker NG160, Vigi NG160 5 03002 + 04227 03205 (1)To add modular devices to the row, order a raised DIN rail (04227). Capacity of modular rail: 48 Multi 9 modules. Width of NG160 circuit breakers: Device NG160 3P : 10 Multi 9 modules NG160 4P : 14 Multi 9 modules Vigi NG160 3P : 24 Multi 9 modules Vigi NG160 4P : 27 Multi 9 modules No. of vertical modules Adjustable modular rail Modular front plate Modular front plate Disjoncteur NG125 NG125, Vigi NG125 5 03002 03205 C120, Vigi C120 Capacity of modular rail: 48 Multi 9 modules. Width of NG125 circuit breakers: NG125 3P : 9 Multi 9 modules NG125 4P : 12 Multi 9 modules Vigi NG125 3P y 63 A: fixed sensitivity 18 Multi 9 modules adjustable sensitivity 20 Multi 9 modules > 63 A: fixed sensitivity 20 Multi 9 modules adjustable sensitivity 20 Multi 9 modules Vigi NG125 4P y 63 A: fixed sensitivity 21 Multi 9 modules adjustable sensitivity 23 Multi 9 modules > 63 A: fixed sensitivity 23 Multi 9 modules adjustable sensitivity 23 Multi 9 modules Device No. of vertical modules Adjustable modular rail Modular front plate Hinged modular front plate INS40/160 INS40/160 4 03002 03204 03211 INS100/160 with long terminal shields 5 03002 03205 Capacity of modular rail: 48 Multi 9 modules. Width of devices: INS40/80: width 10 Multi 9 modules INS100/160: width 15 Multi 9 modules DB114713 125 A Powerclip busbars Available in two lengths (450 and 750 mm) in three and four-pole versions. The busbars can be cut to length every 150 mm. They are supplied with clip-on covers that block off the connected cable lugs and can be cut as needed. Cat. no. selection 125 A Powerclip busbars Cat. no. Three-pole L = 450 mm 04103 L = 750 mm 04107 Four-pole L = 450 mm 04104 L = 750 mm 04108 160/630 A Powerclip busbars Available in two lengths (1000 and 1400 mm) in three and four-pole versions. The busbars can be cut to length every 200 mm. Prefabricated connections are available for the devices. Powerclip busbars 160 A 250 A 400 A 630 A Three-pole L = 1000 mm 04111 04112 04113 04114 L = 1400 mm 04116 04117 04118 04119 Four-pole L = 1000 mm 04121 04122 04123 04124 L = 1400 mm 04126 04127 04128 04129 B-4 version: 1.1 556E2100.indd

Busbar connection to powerclip DB114714 NG160 Vigi incoming device (located on left-hand side) NG160 (without Vigi) incoming device (located in the middle) NG125, INS160, C120 One-piece 3/4 P fast connection to busbars, equipped with male fittings on one end for tunnel terminals. 3 black cables and 1 blue cable (reversible neutral position). Designation Cat. no. 04148 DB114715 One-piece connection, 160 A, L = 440 mm DB114716 160 A Polybloc distribution block 160 A distribution block Designation 160 A Polybloc distribution block, 1P Cat. no. 04031 Note: installation on a raised DIN rail. Connection for NG125, NG160, INS40/160 with or without Vigi Two 45 mm² end fittings for tunnel terminals. Designation DB114717 Four 160 A connections for modular devices, L = 380 mm 125/160 A Distribloc distribution block 125 A distribution block Designation 125 A Distribloc distribution block Note: installation on a raised DIN rail. Cat. no. 04149 Cat. no. 04045 Connection for NG125, INS40/160, C120 with or without Vigi A male ferrule for a tunnel terminal is crimped on one end. A 45 angle lug with a hole is crimped on the other end. 3 black cables and 1 blue cable Designation 4 NG-INS125 connections for Distribloc, L = 210 mm 160 A distribution block Designation 160 A Distribloc distribution block Note: installation on a raised DIN rail. Cat. no. 04047 Cat. no. 04046 Connection for NG160, INS100/160 with or without Vigi The Distribloc 160 A distribution block comes with device connections. Multiclip distribution blocks Distribution block Designation DB114718 Multiclip, 80 A, 4P Multiclip, 63 A, 4P, 1/2 row Multiclip, 200 A, 2P Multiclip, 200 A, 3P Multiclip, 200 A, 4P Multiclip, 160 A, 4P, 1/2 row Cat. no. 04004 04008 04012 04013 04014 04018 Connections Designation Connection between 200 A Multiclip and Powerclip insulated busbars Connection between 160 A Multiclip (1/2 row) and devices 556E2100.indd version: 1.1 Cat. no. 04021 04030 B-5

B-6 version: 1.1 556E2100.indd

NG160 Dimensions and connection Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Mounting NG160, NG160 with Vigi module, Rotary handle 0 C-2 Additional characteristics D-1 Catalogue numbers E-1 556E2200TDM.indd version: 1.1 C-1

Dimensions and connection Mounting NG160, NG160 with Vigi module, Rotary handle NG160 37.5 3 poles 4 poles DB116845 DB116846 DB116847 55.5 120 X 45 X X 64.5 206 (a) (a) 80 102.5 Z (a) Terminal shields. NG160 with Vigi module 45 90 (10 x 9 mm modules) Y 3 poles 4 poles 45 120 (14 x 9 mm modules) Y DB116848 DB116849 DB116850 76 (1) X 45 X X 100 (2) (a) (a) Z 45 Y 210 (24 x 9 mm modules) 75 Y 240 (27 x 9 mm modules) Vigi module dimensions (1) Incoming Vigi module connection via bottom (top out version). (2) Incoming Vigi module connection via the top (bottom out version). (a) Terminal shields DB116851 Rotary handle DB116852 37.5 75 DB116853 Front-panel cut-out 45 83 45 60 Ø50 X 75 37.5 X X 60 Ø4.2 122 min. 167 max. Y 72 36 Y C-2 Z version: 1.1 556E2200.indd

NG160 Additional characteristics Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection C-1 Tripping curves NG160 0 D-2 Catalogue numbers E-1 556E2300TDM.indd version: 1.1 D-1

Additional characteristics Tripping curves NG160 DB116854 16 40 A 50 A DB116855 16 A Im = 37 x In 50 A Im = 12 x In DB116856 63...80 A 100 A DB116857 63 A Im = 12 x In DB116858 125 A 160 A DB116859 160 A Im = 8 x In D-2 version: 1.1 556E2300.indd

NG160 Catalogue numbers Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection C-1 Additional characteristics D-1 NG160E/N/H circuit breakers NG160NA switch-disconnectors 0 NG160E/N/H and NG160NA accessories 0 E-2 E-3 556E5000TDM.indd version: 1.1 E-1

Catalogue numbers NG160E/N/H circuit breakers NG160NA switch-disconnectors 0 DB114710 DB114710 DB114710 DB107583 NG160E NG160N NG160E (16 ka at 380/415 V) Rating 3P (10 x 9 mm modules) 4P (14 x 9 mm modules) Fixed 16 28609 28619 25 28608 28618 32 28607 28617 40 28606 28616 50 28605 28615 63 28604 28614 80 28603 28613 100 28602 28612 125 28601 28611 160 28600 28610 NG160N (25 ka at 380/415 V) Rating 3P (10 x 9 mm modules) 4P (14 x 9 mm modules) Fixed 16 28629 28639 25 28628 28638 32 28627 28637 40 28626 28636 50 28625 28635 63 28624 28634 80 28623 28633 100 28622 28632 125 28621 28631 160 28620 28630 NG160H NG160H (36 ka at 380/415 V) Rating 3P (10 x 9 mm modules) 4P (14 x 9 mm modules) Fixed 16 28649 28659 25 28648 28658 32 28647 28657 40 28646 28656 50 28645 28655 63 28644 28654 80 28643 28653 100 28642 28652 125 28641 28651 160 28640 28650 NG160NA switch-disconnectors Rating 3P (10 x 9 mm modules) 4P (14 x 9 mm modules) 160 28265 28267 Add-on Vigi module Bottom out Rating Sensitivity Delay 3P (14 x 9 mm modules) 4P (14 x 9 mm modules) DB116860 160 Adjustable 30 ma at 3 A Adjustable 0-60 - 150 ms 28310 28311 DB107584 Top out DB116861 Rating Sensitivity Delay 3P (14 x 9 mm modules) 4P (14 x 9 mm modules) 160 Adjustable Adjustable 28312 28313 30 ma at 3 A 0-60 - 150 ms E-2 version: 6.3 556E5100.indd

NG160E/N/H and NG160NA accessories 0 DB107585 Connection accessories Terminal shields (1 pair) for Vigi circuit breaker 3P 28034 4P 28035 Distribution connectors 3 x 16 mm 2 Set of 4 19091 DB107617 DB107616 Mounting accessories Din rail and 4 raisers for Multi 9 devices, length 342 mm For 24 module enclosure 04227 (1) For 36 module enclosure 2 x 04227 (1) DB107588 DB107670 Locking Toggle locking device for 1 or 3 padlocks NSØ5...Ø8 13/64...5/16 Electrical auxiliaries Auxiliary contacts (changeover) 29370 OF or SD 29450 OF or SD low level 29452 DB107586 DB107587 Voltage releases Rotary handles AC 50/60 Hz Tension (V) MX MN 48 28070 28080 110/130 28071 28081 220/240 28072 28082 380/415 28073 28083 440/480 28074 28084 MN 220-240 V 50/60 Hz with time delay composed of: 29421 MN 250 V DC 28088 Delay unit 220-240 V 50/60 Hz 29427 DC Voltage (V) MX MN 24 28075 28085 48 28076 28086 125 28077 28087 250 28078 28088 Black extended handle 28061 Red extended handle on yellow front 28060 (1) MGA parts. 556E5100.indd version: 6.3 E-3

0 Schneider Electric Industries SAS 35, rue Joseph Monier CS 30323 F- 92506 Rueil Malmaison Cedex RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper Design: Schneider Electric Photos: Schneider Electric Printed: 2009 - Schneider Electric - All rights reserved. 556E 10-2009