Relay Product Engineering Tools

Similar documents
Relay configuration and setting tool package

Relay setting toolbox

CAP 505 Relay Product Engineering Tools Installation and Commissioning Guide

Communicate IT Software module DR-COM. Buyer s Guide

CAP 505. User s Guide

Power Products. Protection and Control IED Manager PCM600 Product Guide

MV Process Application Library LIB 510. Product Guide

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

REM 543 Machine Terminal. User s Guide for Modbus Configurations

Communication Gateway COM 500. Product Guide

Terminal tool box CAP 540*1.2

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

Protection and Control IED Manager PCM600 Product Guide

Communication Gateway COM 610. Product Guide

Protection and Control IED Manager PCM600 Product Guide

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

SREDU Double Connection Option Card for Lon Star Coupler RER 111

Connectivity Packages. User's Guide - ANSI Version

Relay Setting Tools CAP 501 Operator s Manual

Substation automation products. MicroSCADA Pro for substation automation

COM600 Station Automation Series MNS is Connectivity (OPC) 3.2. User's Guide

LIB 500 Base & LIB 510 Introduction Operator s Manual

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

Metasys Installation and Platform Requirements

SYS 500 Installation 1MRS MEN. Notice 1. Notice 2. Notice 3. Trademarks

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

User s Manual CAP 531*1.5 Configuration and Programming tool

LNT 505 Installation and Commissioning Manual

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide

COM600 Station Automation Series External OPC Client Access 3.1. User's Guide

Power Products. Station Automation COM600 Product Guide

Grid Automation Controller COM600 How it fits into the Smart Grid?

Data communication and reporting unit

Protection System Simulator SIM600. Installation Manual

Power Products. Station Automation COM600 Product Guide

Data communication and reporting unit

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Grid Automation Products. MicroSCADA Pro Substation automation applications.

Modbus Remote Communication Protocol for REM 54_. Technical Description

RER 123 Bus Connection Module. Technical Description

MicroSCADA Pro Substation automation applications.

Synchro-check relay. Application

Residual overvoltage relay

General characteristics of C-type relay modules

High impedance protection relay

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Quick Start Guide PCM600 for Relion 650/670 Series

XEROX. CopyCentre / WorkCentre Pro Auditron Report Software. User Manual

PSM 505. Inform IT Power System Monitoring. Stand-alone Fault Analysis and Evaluation Tool. Technical Data. Introduction.

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

LIB 510 MV Process Operator s Manual

Installing MachineShop... 2

Feeder protection relay SPAA 121 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

LIB 500 Event List Operator s Manual

VM600 Configuration Software. Configuration Software for VM600 Series Machinery Protection Systems (MPS) FEATURES

Station Automation COM Logic Processor User's Manual

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

FX Tools Express Software Package

Laurent Sowazi, EPMV-DA/ Africa Channel Partner event, 2016 ABB Distribution Automation Making Grids Smarter. ABB November 23, 2016

Metasys System Configuration Tool (SCT)

Control Solutions MICRO-DCI COMMUNICATION SERVICES

Relion 611 series. 611 series Type Test Certificate

MicroSCADA Pro DMS 600 *4.1 System Overview. Technical Description

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

PL-69** Series Replacement Guidebook

LonScanner TM Protocol Analyzer User's Guide

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

MicroSCADA Pro SYS Connecting LONWORKS Devices

FX Tools Software Package - FX CommPro LON User Guide

PCM-9342 EVA-X SBC with PC/104, VGA/ TTL/LVDS Ethernet/USB 2.0 and SSD Startup Manual

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

Arc protection relay. Features Three-phase overcurrent function. Application

User s Manual. PC-Based Measurement Instruments. Setup Guide for Windows Vista IM E. 1st Edition

UPGRADE INSTRUCTIONS

PL-69** Series Replacement Guidebook

SM/SACO for SMS 010 User s Guide SMS 010 SACO library

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

REF 54_ Feeder Terminal REM 54_ Machine Terminal Operator s Manual

DAQ-System for DynoWare

Arc protection relay. Features Three-phase overcurrent function. Application

PL-79** Series Replacement Guidebook

INSTALLATION AND USER GUIDE

Communication with EuroProt-IED Multifunctional intelligent devices

Feeder protection relay

Sage BusinessWorks v8.0 System Standards

Installation and Operating Instructions

ABB ABB Oy, Distribution Automation

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

REX 521 Protection Relay Operator s Manual

Protection Terminal REF 54_ Protection Relay REX 521

PCM-9361 Intel Atom N SBC with PC/104, VGA/ TTL/LVDS Ethernet/USB 2.0, SATA and SSD Startup Manual

EbixONE Microsoft Solution System, Network, and Software Requirements

SCRIBE EC NO PRINTER QUICK INSTALLATION GUIDE

Software Release Notice TimeScan For Windows 2000/XP/Vista Release 8.7

DocSTAR v3.3 Software Installation Guide Page 1

PCM-9588 Intel Celeron M EBX SBC with DVI/ TTL/ VGA/ LVDS/ LAN/ 6 COM/ 2 SATA/ 6 USB2.0/16-bit GPIO Startup Manual

Motor Protection Relay REM 610. Product Guide

SeaChange InSite. the Program for engineering documenting maintaining using SeaChange Control Systems

Transcription:

Relay Product Engineering Tools CAP 505 Issued: May 1999 Status: Updated Version:D/16.09.2003 Data subject to change without notice Features Function logic configuration tool according to IEC 61131-3 standard for ABB range of protection relays and terminals for distribution applications Graphical and textual configuration of mimic panels Loading of function and mimic configurations to the target product General parameter setting support User friendly tool management Parameter file upload/download and compare function Configuration and parameter file printing support Manually initiated uploading of disturbance recorder data Versatile integration of disturbance data evaluation tools of your choice Easy switching between verified setting groups or setting banks Reset of protection relay Presents relay indications, measurement, calculated values and registered values Connection to the station bus alternatively directly to a protection relay or a terminal using SPA or LON communication protocol Flexible object based tree-structure navigator Object oriented project data management Project import/export facility Excellent commissioning tools Easy to upgrade to support new functions and products All tools and documentation provided on one CD Application The CAP 505 Relay Product Engineering Tools is aimed for commissioning, maintenance, service and monitoring of the process and its secondary equipment in distribution substations. The package includes the following tool functions: Relay configuration Mimic panel configuration Configuration download Project import/export Parameter setting and archiving Compare between parameter settings in the relay and the archive Upload and download of paramer setting files Printing of parameter setting files Edit history of parameters Protection relay setting bank switching Reset of protection trip function Upload of disturbance recorder files Upload of registered, measured and calculated values Multi layered tree structure navigator 1

Relay Product Engineering Tools CAP 505 Design As the tools in CAP 505 are fully consistent with CAP 501 stand-alone tool packages, SMS 510 substation monitoring system and the LIB 500 application libraries, work generated by CAP 505 can easily be reused in a larger SMS system or in a full-fledged SA system. The range of protection and control terminals with SPA communication supported in CAP 505 Revision 2.2.0: The entire SPACOM range including SACO annunciators The Multipurpose Relay Series REJ 5 / REU 5 A station control and protection system contains numerious components and functions. CAP 505 is the tool box for data handling during the engineering and maintenance of relay projects. The CAP 505 product consists of a base system with a navigator on which support tools for the protection and control terminals are run. The communication between the computer and the target is run either using the LON communication protocol or the SPA protocol. Categorization of the software parts Base System Kernel software, communication configuration, additional base tools and services are providing a framework for the object types and tools. Fig. 1 CAP 505 Navigation window Project structure navigator The Project structure navigator is a window in which you open tools and close your session. It is possible to add and delete tools on the System Tools menu. The REF 541/543/545 Integrated Protection and Control Terminals The REM 543/545 Integrated Machine Protection and Control Terminals The The REX 521 Integrated Protection and Control Terminal The REC 501/523 Control Terminals The REM 610 Motor protection relay Further information about CAP 505 and its application in single relay applications and in local and remote system solutions can be found in the full product documentation on the product CD-ROM. System Configuration tool The communication setup is done with the system configuration tool Project Export/Import tool The tool is used for project management purposes. Creating a project, defining default projects for the objects tools, project duplication and project delete are among the functions included. The tool is used when projects are transferred to other systems or brought to the user s current collection of projects. Relay Configuration tool The functional configuration of the protection relays and control terminals is done with this tool. Functions to be configurated are: protection sheme, control sheme, I/O set-up, measurements, condition monitoring, power quality and other similar type of functions. The graphical programming language is based on the IEC 61131-3 standard. Function blocks are available for a variety of protection, control, measurements functions. Mimic Configuration tool The tool is used for configuring the graphical front display on the control terminals. The configuration includes breakers, disconnectors, interconnections, alarms, measurements, and texts defined by a user. Downloading tool The function and mimic configurations are downloaded to the targe product by means of this tool. The storing of the configuration in the non-volatile memory of the protection or control terminal and the restart of the terminal are included as well. 2

Relay Product Engineering Tools CAP 505 Relay Setting tool The relay setting tool includes all functions belonging to parameter, register- and input values and reset functions. The package include a separate tool for SPACOM products and another tool for all other terminals. The parameter sets are mostly created off-line and then downloaded to the products. Existing parameter files in the products can be uploaded and edited as well. Fig. 3 Disturbance Recorder Tool window Fig. 2 REMMI Relay Setting Tool Disturbance Recorder tool Includes the functionality to upload and present disturbance recordings. Fig. 4 DR_ collector Tool window System configuration Document files Technical data The tool package is delivered on a CD which can be installed on a PC with Win NT or Win 2000 operating system. The PC communicates to the station bus, to the protection relay or to the terminal using CAP 505 documentation in PDF format and an installer for installing the Acrobat Reader from Adobe Corporation are included on the CD. The Acrobat Reader is needed to view the documentation. CAP 505 v.2.2.0 sets the following hardware and software requirements for the PC: Table 1: Software requirements the SPA or LON protocol via a product specific cable connected between the PC,s COM port or LON port and the communication inteface of the relays. Operating system Network Microsoft Windows NT 4.0 Workstation. It is recommended to have Service Pack 5 installed. Microsoft Windows 2000. It is recommended to have Service Pack 3 installed. Operating system network software installed with at least one network protocol (e.g. TCP/IP) 3

Relay Product Engineering Tools CAP 505 Table 2: Hardware requirements Item Minimum Recommended Processor 233 MHz or higher Pentium compatible CPU 1 GHz or higher Pentium compatible CPU Memory 128 MB 256 MB Display SVGA, 800x600, 256 colours SVGA, 1024x768, 256 colours File system NTFS file system on the installation drive Hard disk space 300 MB 500 MB CD-ROM drive Any device supported by the operating system. Required for installation Mouse Any device supported by the operating system PCI slots One slot for each PCLTA-20 card PCMCIA slots One slot for each PCC-10 card Network adapter card Any device supported by the operating system TRADEMARKS. Intel and Pentium are registered trademarks of Intel Corporation. Neuron, LON and LONWORKS are registered trademarks of Echelon Corporation Acrobat is a registered trademark of Adobe Systems Incorporated. All Microsoft products referenced in this document are either trademarks or registered trademarks of Microsoft Corporation. Other brand or product names are trademarks or registered trademarks of their respective holders. Ordering The ordering number for CAP 505 version 2.2.0 tool package CD is 1MRS151017. The communication cables listed in the next table are not included in the CAP 505 delivery. Required communication cables can be acquired by placing a separate order, see the table below: Table 3: Communication harware Relay Type Order number REF 541, 543, 545 Opto 1MCK950001-1 REM 54_ REC REX A-series REM 610 Opto (Please contact your nearest 1MRS050698 ABB representative for availability.) SPTO front connector RS 232 - RS 232 SPA-ZP 17A3 SPCR front connector SPACOM 100/300 series RS 232 - TTL connector SPA-ZP 5A3 SPAC 300/500/600 series rear RS 232 - RS 485 SPA-ZP 6A2 SACO 16A3, 16D1, 16D3 and 64D4 Connection cable for SPA-ZP 6A2 to SACO srew terminals SPA-ZP 21A and SPA-ZP 6A2 4

ABB Oy Substation Automation P.O. Box 699 FIN-65101 Vaasa, Finland Tel +358 10 22 11 Fax +358 10 224 1094 www.abb.com/substationautomation