CA Spool 11.7 1 CA RS 1307 Service List Description Hiper 11.7 RO57457 WHEN TRANSFRM OPT 1 + MAXCPU EXCEEDED, FILES ARE NOT QUEUED RO57788 A2PC: FILE IS NOT HELD WHEN CHANNEL NOT DEFINED IN PAGEDEF RO59492 SUBSYSTEM COPY FILE STATUS EI RO59939 ADD ENVIRONMENT VARIABLES FOR THE BATCH TRANSFORMER UTILITY RO60440 LOOP CAN OCCUR AFTER RO59939 The CA RS 1307 service count for this release is 5
CA Spool 11.6 2 CA RS 1307 Service List Description Hiper 11.6 RO58262 SUBSYSTEM COPY FILE STATUS EI The CA RS 1307 service count for this release is 1
CA Spool 3 CA RS 1307 Service List for CBQ4B60 FMID Service Description Hiper CBQ4B60 RO58262 SUBSYSTEM COPY FILE STATUS EI The CA RS 1307 service count for this FMID is 1
CA Spool 4 CA RS 1307 Service List for CBQ4B70 FMID Service Description Hiper CBQ4B70 RO57457 WHEN TRANSFRM OPT 1 + MAXCPU EXCEEDED, FILES ARE NOT QUEUED RO57788 A2PC: FILE IS NOT HELD WHEN CHANNEL NOT DEFINED IN PAGEDEF RO59492 SUBSYSTEM COPY FILE STATUS EI RO59939 ADD ENVIRONMENT VARIABLES FOR THE BATCH TRANSFORMER UTILITY RO60440 LOOP CAN OCCUR AFTER RO59939 The CA RS 1307 service count for this FMID is 5
CA Spool 11.7 5 CA RS 1307 - PTF RO57457 11.7 RO57457 RO57457 M.C.S. ENTRIES = ++PTF (RO57457) WHEN TRANSFRM OPT 1 + MAXCPU EXCEEDED, FILES ARE NOT QUEUED If Node parameter TRANSFRM is specified with option 1 and the MAXCPU value coded on the X2YY statement is exceeded during transformation, additional files sent to that Node are no longer queued for transformation. Files remain in ' ' (blank) status and are not queued for transformation. Manual intervention is required in order to transform additional files. Drain the Node and issue the REINIT command. PRODUCTS AFFECTED: CA Spool r11.5 CA Spool r11.6 CA Spool r11.7 CSPOOL 1720 Copyright (C) 2013 CA. All rights reserved. R00079-SPL117-SP1 DESC(WHEN TRANSFRM OPT 1 + MAXCPU EXCEEDED, FILES ARE NOT QUEUED). FMID (CBQ4B70) PRE ( RO34824 RO37983 RO51087 ) SUP ( RO46845 RO47701 RO48603 TR46845 TR47701 TR48603 TR57457 )
CA Spool 11.7 6 CA RS 1307 - PTF RO57788 11.7 RO57788 RO57788 M.C.S. ENTRIES = ++PTF (RO57788) A2PC: FILE IS NOT HELD WHEN CHANNEL NOT DEFINED IN PAGEDEF When a skip to channel xx is specified in the input data (where xx represents a numeric value in range of 1-12), and the appropriate channel is not defined in the active page definition, the input file is transformed without any warning message in the ESFLOG. There is a need to display the warning message in the ESFLOG and avoid the input file to be processed. This problem appears only when the CA Spool Java Transformers are used. The input file with a skip to channel xx specified is transformed without any warning message in the ESFLOG. The document is not printed correctly. No warning message indicating the error is displayed in the ESFLOG and this increases time needed to find out the cause of the problem. In addition, the file is not held and it leads to paper wastage. None. PRODUCT AFFECTED: CA Spool r11.6 CA Spool r11.7 CSPOOL 1755 Copyright (C) 2013 CA. All rights reserved. R00081-SPL117-SP1 DESC(A2PC: FILE IS NOT HELD WHEN CHANNEL NOT DEFINED IN PAGEDEF). FMID (CBQ4B70) PRE ( RO38599 RO40354 RO42349 RO43549 RO44916 RO47305 RO50779 RO52274 ) SUP ( AR44916 RO47268 TR47268 TR48911 TR57788 ) ++HOLD (RO57788) SYSTEM FMID(CBQ4B70) REASON (DOC ) DATE (13143) COMMENT ( Product: CA Spool Release: 11.7 Publication: CA Spool Java Transformers Administration Guide See PRODUCT DOCUMENTATION CHANGE (PDC) RI59105 for documentation update. ).
CA Spool 11.7 7 CA RS 1307 - PTF RO59492 11.7 RO59492 RO59492 M.C.S. ENTRIES = ++PTF (RO59492) SUBSYSTEM COPY FILE STATUS EI After applying RO47700 for 11.6 or RO47701 for 11.7 a problem occurs when using the Subsystem interface to read files from CA Spool. After the file is read, the file queued gets locked in the EI status (E - End of file reached/i - Opened for input). File status remains in EI status. The file is locked in the EI status. The file cannot be copied again and the file cannot be printed. Specify the BROW parameter in the SUBSYS statement. For example: SUBSYS=(ESFH,F2034,FILENM,PRNTRNM,,,,BROW) PRODUCT(S) AFFECTED: CA Spool r11.6 CA Spool r11.7 CSPOOL 1758 Copyright (C) 2013 CA. All rights reserved. R00083-SPL117-SP1 DESC(SUBSYSTEM COPY FILE STATUS EI). FMID (CBQ4B70) PRE ( RO34824 RO47701 RO57457 ) SUP ( AR57457 RO46845 TR46845 TR59492 )
CA Spool 11.7 8 CA RS 1307 - PTF RO59939 11.7 RO59939 RO59939 M.C.S. ENTRIES = ++PTF (RO59939) ADD ENVIRONMENT VARIABLES FOR THE BATCH TRANSFORMER UTILITY Support for new environment variables in the Batch Transformer is added to improve the efficiency of the batch process and to position for future interfaces with other CA products. This enhancement applies only to the use of the Batch Transformer Utility with the CA Spool Java Transformers. Environment variables cannot be passed to the Batch Transformer Utility for use with the CA Spool Java Transformers. The Batch Transformer Utility can be made more efficient for customers using it with the CA Spool Java Transformers. None. PRODUCT(S) AFFECTED: CA Spool r11.7 CSPOOL 1665 Copyright (C) 2013 CA. All rights reserved. R00085-SPL117-SP1 DESC(ADD ENVIRONMENT VARIABLES FOR THE BATCH TRANSFORMER UTILITY). FMID (CBQ4B70) PRE ( RO34824 RO37983 RO38599 RO38825 RO40354 RO43549 RO44916 RO47305 RO47701 RO48199 RO51087 RO57457 RO57788 ) SUP ( AR44916 AR57457 RO34623 RO42349 RO46845 RO47268 RO49901 RO50211 RO50405 RO50779 RO52274 RO59492 TR34623 TR42349 TR46845 TR47268 TR48911 TR49901 TR50211 TR50405 TR50779 TR52274 TR52982 TR59492 TR59606 TR59939 ) ++HOLD (RO59939) SYSTEM FMID(CBQ4B70) REASON (DOC ) DATE (13172) COMMENT ( Product: CA Spool Release: 11.7 Publication: CA Spool Java Transformers Administration Guide See PRODUCT DOCUMENTATION CHANGE (PDC) RI60140 for documentation update. ).
CA Spool 11.7 9 CA RS 1307 - PTF RO60440 11.7 RO60440 RO60440 M.C.S. ENTRIES = ++PTF (RO60440) LOOP CAN OCCUR AFTER RO59939 After applying RO59939, the Transformer Interface is not halted after an ESF4209 Initialization failed message is issued. CA Spool then tries to start the Java Transformer FSS task again and again. Repeated start commands will be seen in the CA Spool task log: 05.09.31 STC60468 START ESFD2E.D2E01,,,(ESF,0006) 05.09.32 STC60468 START ESFD2E.D2E01,,,(ESF,0006) 05.09.33 STC60468 START ESFD2E.D2E01,,,(ESF,0006) 05.09.34 STC60468 START ESFD2E.D2E01,,,(ESF,0006) 05.09.35 STC60468 START ESFD2E.D2E01,,,(ESF,0006) 05.09.36 STC60468 START ESFD2E.D2E01,,,(ESF,0006) The Java Transformer FSS D2ELOG contains message: ESF4209 Initialization failed. Correct above problems and restart FSS The CA Spool Java transformers are no longer functional. Enter CA Spool HT command to manually halt the Transformer Interface. Correct the configuration error causing message ESF4209. Enter the CA Spool ST command to restart the Transformer Interface. PRODUCT(S) AFFECTED: CA Spool r11.7 CSPOOL 1787 Copyright (C) 2013 CA. All rights reserved. R00088-SPL117-SP1 DESC(LOOP CAN OCCUR AFTER RO59939). FMID (CBQ4B70) PRE ( RO38599 RO40354 RO43549 RO44916 RO47305 RO57788 RO59939 ) SUP ( AR44916 AR59939 RO42349 RO47268 RO50405 RO50779 RO52274 TR42349 TR47268 TR48911 TR50405 TR50779 TR52274 TR60437 TR60440 )
CA Spool 11.6 10 CA RS 1307 - PTF RO58262 11.6 RO58262 RO58262 M.C.S. ENTRIES = ++PTF (RO58262) SUBSYSTEM COPY FILE STATUS EI After applying RO47700 for 11.6 or RO47701 for 11.7 a problem occurs when using the Subsystem interface to read files from CA Spool. After the file is read, the file queued gets locked in the EI status (E - End of file reached/i - Opened for input). File status remains in EI status. The file is locked in the EI status. The file cannot be copied again and the file cannot be printed. Specify the BROW parameter in the SUBSYS statement. For example: SUBSYS=(ESFH,F2034,FILENM,PRNTRNM,,,,BROW) PRODUCT(S) AFFECTED: CA Spool r11.6 CA Spool r11.7 CSPOOL 1758 Copyright (C) 2013 CA. All rights reserved. R00156-SPL116-SP1 DESC(SUBSYSTEM COPY FILE STATUS EI). FMID (CBQ4B60) PRE ( RO22142 RO27067 RO47700 RO54308 ) SUP ( AR54308 RO30473 RO37017 TR22142 TR30473 TR37017 TR58262 )