BNI IOL-104-S01-Z012-C02

Similar documents
BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z012. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL Z036 BNI IOL Z036

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI IOL-75x-Vxx-K007 Valve Plug Short Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI IOL Z012. User s Guide

BNI IOL A027 BNI IOL A027

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI USB A501. USB IO-Link Master User's Guide. english

BNI IOL Z036 BNI IOL Z BNI IOL Z037 BNI IOL Z Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

BNI USB A501. User s Guide

BIS L x-07-S4

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI EIP Z015 IP67 Modules 16 Inputs User s Guide

BNI EIP Z015-C06. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BNI EIP E002. EtherNet/IP IP69 modules User's Guide

Balluff Network Interface / CC-Link BNI-CCL Z001 BNI CCL Z001. Extended User Manual. 1

BNI PNT Z015 BNI006C. IP67 Module User s Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BNI EIP Z040. IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide

BNI EIP Z015. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide

BNI PNT Z031 BNI PNT Z IP67 Module User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 modules User's Guide

BNI CIE Z015 BNI CIE Z015 BNI CIE Z015 BNI CIE Z015. CC-Link IE Field Standard I/O Modules User's Guide

BNI EIP R015 BNI EIP R015. EtherNet/IP IP67 modules User's Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

GFK-2415A March Type of sensor connection

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Profibus IO Modules User's Guide

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

BNI CIE Z015 BNI CIE Z015. CC-Link IE Field IO-Link Master User's Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide

VersaMax IP I/O Module

BIS L x-07-S4

BNI EIP Z015 BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 Modules User s Guide

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4

BTL6-V1 _ E-M -A1-S115 User's Guide

BIS V-6102 PROFIBUS. Technical Description, User s Guide. english 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

BIS L , BIS Z-EL-...

User's Manual. english

BTL6-V11V-M -A1-S115 User's Guide

BNI EIP Z015-C06. EtherNet/IP IP67 modules User's Guide

BIS M _ -07-S4 BIS M _ -07-S4

BIS V-6102 Profibus. Technical Description, User's Guide. English 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

Manual LioN-P - IO-Link Device - I/O Hub

VersaMax IP Input Module

AXL E IOL AO1 U M12 R

BTL6-A_10-M -A1-S115. Data Sheet. english

Profibus I/O Modules BNI PBS Z001 BNI PBS Z001

BIS M x-ST4 EtherNet/IP

SK TU4-IOE-M12-C Part Number

BIS M xx-ST4 PROFINET

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

BNI PNT Z063. IP67 Module User's Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BTL5-A/C/E1_-M- -SF-F User's Guide

BIS V-6108 PROFINET. Technical Description, User s Guide. english

Manual ICA-16DI-G60A-IO, ICA-10DI6DO-G60A-IO. I/O Hub with IO-Link

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Operating instructions ClassicLine module AC / / 2012

Operating instructions Memory plug E /02 11/2011

BIS V-6102 PROFIBUS Technical Reference, Operating Manual

SmartWire-DT Modules IP67

BIS V-6111 CC-Link Technical Description, User s Guide

Assembly and Operating Instructions. M2 module for BDC-i440 control units

CPCI-PS24 24V-Power Supply

Operating instructions AC010S Compact AS-i E-STOP safety module

Transcription:

BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide

Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax 2 1.3.4 Cross references 2 1.4 Symbols 2 1.5 Abbreviations 2 2 Safety 2.1 Intended use 3 2.2 General safety notes 3 2.3 Meaning of the warnings 3 3 Getting started 3.1 Connection overview Z012 4 3.2 Connection overview Z013 5 3.3 Mechanical connection 6 3.4 Electrical connection 6 3.4.1 IOLink interface 6 3.4.2 Supply voltage connection 7 3.4.3 Sensor/actuator interface 7 4 IOLink interface 4.1 IOLink data 8 4.2 Process data / Input data 8 4.3 Process data / Output data 9 4.4 Parameter data / Request data 10 4.5 Error 12 4.6 Events 12 5 Technical data 5.1 Dimensions 13 5.2 Mechanical data 13 5.3 Electrical data 13 5.4 Operating conditions 13 5.5 LED indicators 14 Appendix Product ordering code 15 Order information 15 Scope of delivery 15 Notes www.balluff.com

Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide This guide describes the Balluff Network Interface BNI IOL. for the application as peripheral in/ output module to establish connection of binary standard sensors or actuators. Hereby it is about an IOLink device which communicates by means of IOLink protocol with the superordinate IOLink master assembly. 1.2 Structure of the guide 1.3 Typographical conventions 1.3.1 Enumerations The guide is organized so that the sections build on one another. Section 2: Basic safety information. Section 3: The main steps for installing the device. Section 4: IOLink, parameter and process data for the device. Section 5: Technical data for the device. The following typographical conventions are used in this guide. Enumerations are shown in list form with bullet points: Entry 1, Entry 2. 1.3.2 Actions Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1. Action result. Action instruction 2. 1.3.3 Syntax Numbers: Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00hex). 1.3.4 Cross references Cross references indicate where additional information on the topic can be found (see section 5 Technical Data ). 1.4 Symbols Note, Tipp This symbol indicates general notes. Note! This symbol indicates a security notice which must be observed. 1.5 Abbreviations BNI Balluff Network Interface I/Oport Standard In/ Output port DPP Direct parameter page IOL IOLink EMC Electromagnetic Compatibility FE Function earth SPDU Service Protocol Data Unit www.balluff.com 2

Balluff Network Interface / IOLink 2 Safety 2.1 Intended use This guide describes the Balluff Network Interface BNI IOL for the application as peripheral in/ output module to establish connection of binary sensors or actuators. Hereby it is about an IOLink device which communicates by means of IOLink protocol with the superordinate IOLink master assembly. 2.2 General safety notes Installation and start up Installation and start up are to be performed only by trained specialists. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer s guarantee and warranty. The device complies with EMC Class A. Such equipment may generate RF noise. The operator must take precautionary measures accordingly. The device must be powered only using an approved power supply (see section 5 Technical data ). Only approved cable may be used. Operating and testing The operator is responsible for observing local prevailing safety regulations. When defects and nonclearable faults occur in the device, take it out of service and secure against unauthorized use. Approved use in ensured only when the housing is fully installed. 2.3 Meaning of the warnings Note! The pictogram used with the word Caution warns against a possible hazardous situation affecting the health of persons or resulting in equipment damage. Ignoring these warnings can result in injury or equipment damage. Always observe the described measures for preventing this danger. www.balluff.com 3

Balluff Network Interface / IOLink 3 Getting started 3.1 Connection overview BNI IOL104. 16 1 15 2 14 13 3 4 12 5 11 6 10 9 7 8 Figure 31: Connection overview BNI IOL104S01Z012C0x 1 Mounting hole 2 Label 3 Status LED: Communication / module 4 Port 1 5 Port 3 6 Port 5 7 Port 7 8 Mounting hole 9 Pin/Port LED: Signal status 10 Port 6 11 Port 4 12 Port 2 13 Port 0 14 Status led: module supply 15 IOLink interface 16 Ground connection www.balluff.com 4

Balluff Network Interface / IOLink 3 Getting started 3.2 Connection Overview BNI IOL302 17 16 1 2 3 15 14 4 5 13 6 12 7 11 10 8 9 Figure 32: Connection overview BNI IOL302S01Z013C01 1 Mounting hole 2 Label 3 Auxiliary power connection 4 Status LED: Communication / module 5 Port 1 6 Port 3 7 Port 5 8 Port 7 9 Mounting hole 10 Pin/Port LED: Signal status 11 Port 6 12 Port 4 13 Port 2 14 Port 0 15 Status LED: Supply voltages 16 IOLink Interface 17 Ground connection www.balluff.com 5

Balluff Network Interface / IOLink 3 Getting started 3.3 Mechanical connection The BNI IOL modules are attached by using 2 M6 screws and 2 spacers. 3.4 Electrical connection The BNI IOL104S01Z012C0x module requires no separate supply voltage connection. Power is provided through the IOLink interface by the host IOLink Master. The BNI IOL302S01Z013C01 module requires a separate power supply for the actuators and sensors. This power supply is provided through the auxiliary power connection. Supply of the communication section is made through the superordinate IOlink master assembly. 3.4.1 IOLink interface IOLink (M12, Acoded, male) PIN Function 1 Power supply controller, +24V, max 1.1A 2 not used 3 GND, reference potential 4 C/Q, IOLink Data transmission channel Connecting the hub Connection protection ground to FE terminal, if present. Connect auxiliary power supply if present. Connect the incoming IOLink line to the Sensor Hub. Note: A standard 3 wire sensor cable is used for connection to the host IOLink master. Function earth Figure 33: FE connection Note: The FE connection from the housing to the machine must be lowimpedance and kept as short as possible. Module versions Hub Versions BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 Digital port 16 Inputs with single channel monitoring, 2 Identification bytes 16 Inputs with single channel monitoring, 4 Identification bytes 16 Inputs 16Outputs, configurable, with single channel monitoring 2 Identification bytes www.balluff.com 6

Balluff Network Interface / IOLink 3 Getting started 3.4.2. Supply voltage connection 3.4.3 SensorActuator interface Power In (7/8, male) Pin Function 1 GND, Reference potential 2 GND, Reference potential 3 FE, Function earth 4 Power supply sensors, +24V 5 Power supply actuators, +24V Standard I/Oport (M12, A coded, female) PIN 1 +24V, 100mA / 300mA* 2 Input 2 /Output 2 3 GND 4 Input 1 /Output 1 5 FE Function * 100mA BNI IOL104S01Z012C0x 300mA BNI IOL302S01Z013C01 Note: For the digital sensor inputs follow the input guideline per EN611312, type 2. Note: Unused I/Oport sockets must be fitted with cover caps to ensure IP67 protection rating. www.balluff.com 7

Short circuit Port 7 Short circuit Port 6 Short circuit Port 5 Short circuit Port 4 Short circuit Port 3 Short circuit Port 2 Short circuit Port 1 Short circuit Port 0 Under voltage UV Input 7.0 Input 6.0 Input 5.0 Input 4.0 Input 3.0 Input 2.0 Input 1.0 Input 0.0 Input 7.1 Input 6.1 Input 5.1 Input 4.1 Input 3.1 Input 2.1 Input 1.1 Input 0.1 Balluff Network Interface / IOLink 4 IOLink interface 4.1 IOLink data BNI IOL104S01Z012C01 / BNI IOL104S01Z012C02 4.2 Process data / Input data BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 Data transmission rate COM2 (38,4 kbaud) COM2 (38,4 kbaud) Frame type 1 1 Minimal cycle time 3 ms 3 ms Process data cycle time 18 ms, at minimal cycle time 24 ms, at minimal cycle time Process data length 6 Byte input 8 Byte input BNI IOL302S01Z013C01 Data transmission rate COM2 (38,4 kbaud) Frame type 1 Minimal cycle time 3 ms Process data cycle time 30 ms, at minimal cycle time Process data length 10 Byte input BNI IOL104S01Z012C01 BNI IOL104S01Z012C02* Byte 0 Byte 1 Signal port (x): x.0: Pin 4, X.1: Pin 2 Byte 2 Byte 3 Byte 4 Byte 5 Identification byte 0 Identification byte 1 Byte 6 Byte 7 Identification byte 2* Identification byte 3* www.balluff.com 8

Output 7.0 Output 6.0 Output 5.0 Output 4.0 Output 3.0 Output 2.0 Output 1.0 Output0.0 Output 7.1 Output 6.1 Output 5.1 Output 4.1 Output 3.1 Output 2.1 Output 1.1 Output 0.1 Warning Port 7.0 Warning Port 6.0 Warning Port 5.0 Warning Port 4.0 Warning Port 3.0 Warning Port 2.0 Warning Port 1.0 Warning Port 0.0 Warning Port 7.1 Warning Port 6.1 Warning Port 5.1 Warning Port 4.1 Warning Port 3.1 Warning Port 2.1 Warning Port 1.1 Warning Port 0.1 Short circuit Port 7.0 Short circuit Port 6.0 Short circuit Port 5.0 Short circuit Port 4.0 Short circuit Port 3.0 Short circuit Port 2.0 Short circuit Port 1.0 Short circuit Port 0.0 Short circuit Port 7.1 Short circuit Port 6.1 Short circuit Port 5.1 Short circuit Port 4.1 Short circuit Port 3.1 Short circuit Port 2.1 Short circuit Port 1.1 Short circuit Port 0.1 Short circuit Port 7 Short circuit Port 6 Short circuit Port 5 Short circuit Port 4 Short circuit Port 3 Short circuit Port 2 Short circuit Port 1 Short circuit Port 0 Under voltage UV Input 7.0 Input 6.0 Input 5.0 Input 4.0 Input 3.0 Input 2.0 Input 1.0 Input 0.0 Input 7.1 Input 6.1 Input 5.1 Input 4.1 Input 3.1 Input 2.1 Input 1.1 Input 0.1 Balluff Network Interface / IOLink 4 IOLink interface BNI IOL302S01Z013C01 Byte 0 Byte 1 Signal port (x): x.0: Pin 4, X.1: Pin 2 Byte 2 Byte 3 Short circuit on Port x between Pin 1 and Pin 3 Short circuit port x = 1 where x=0...7 Byte 4 Byte 5 Actuator short circuit on port x Short circuit port x.0 = Pin 4 Short circuit port x.1 = Pin 2 Byte 6 Byte 7 Actuator warning at signal port on port x Warning port x.0 = Pin 4 Warning port x.1 = Pin 2 Byte 8 Byte 9 Identificationbyte 0 Identificationbyte 1 4.3 Process data / Output data Note: Actuator short circuit: overload or short circuit of the output signal against 0V. Actuator warning signal: short circuit of the output signal against +24V BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 No output data BNI IOL302S01Z013C01 Byte 0 Byte 1 Signal port (x): x.0: Pin 4, X.1: Pin 2 www.balluff.com 9

Inversion 7.0 Inversion 6.0 Inversion 5.0 Inversion 4.0 Inversion 3.0 Inversion 2.0 Inversion 1.0 Inversion 0.0 Inversion 7.1 Inversion 6.1 Inversion 5.1 Inversion 4.1 Inversion 3.1 Inversion 2.1 Inversion 1.1 Inversion 0.1 Parameter data Identification data Balluff Network Interface / IOLink 4 IOLink interface 4.4 Parameter data / Request data DPP Index 0x07 0x08 0x09 0x0A 0x0B Index SPDU Sub Index Object name Length Range Default value Vendor ID Device ID 2 Byte 3 Byte 0x0378 0x050709 0x05070M 0x05070D 0x10 0 Vendor name 7 Byte BALLUFF 0x11 0 Vendor text 15 Byte www.balluff.com read only BNI IOL104S01Z012C01 0x12 0 Product name 20 Byte BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 BN 003T 0x13 0 Product ID 7 Byte BNI005P BN 0048 Sensor hub metal 16 inputs + ID 0x14 0 Product text 22 Byte Sensor/Actor hub metal 0x16 0 Hardware Revision 1 Byte 0x17 0 Firmware Revision 23 Byte 0x40 0x41 0x42 0x43 0x44 0x45 0x46 0x60 0x60 0 116 0 116 0 116 0 116 0 116 0 116 0 116 0 116 0 132** Inversion 2 Byte 0FFFF 0x0000 Port Direction* 2 Byte 0FFFF 0x0000 Secure state Pin4* 2 Byte 0FFFF 0x0000 Secure state Pin2* 2 Byte 0FFFF 0x0000 Sp. monitoring 2 Byte 0FFFF Actuator short circuit* 2Byte 0FFFF Actuator warning* 2 Byte 0FFFF Identification 2 Byte 0FFFF Identification * Only in case of BNI IOL302S01Z013C01 ** Only in case of BNI IOL302S01Z013C02 Inversion 4 Byte** 0FFFF FFFF** Byte 0 Byte 1 Inversion port (x): x.0: Pin 4, x.1: Pin 2 Inversion 0: normal 1: inverted www.balluff.com 10

Short circuit port 7.0 Short circuit port 6.0 Short circuit port 5.0 Short circuit port 4.0 Short circuit port 3.0 Short circuit port 2.0 Short circuit port 1.0 Short circuit port 0.0 Short circuit port 7.1 Short circuit port 6.1 Short circuit port 5.1 Short circuit port 4.1 Short circuit port 3.1 Short circuit port 2.1 Short circuit port 1.1 Short circuit port 0.1 Short circuit port 7 Short circuit port 6 Short circuit port 5 Short circuit port 4 Short circuit port 3 Short circuit port 2 Short circuit port 1 Short circuit port 0 Under voltage UA Under voltage US2 Under voltage US1 Secure st. 3.1 Secure st. 2.1 Secure st. 1.1 Secure st. 0.1 Secure st. 7.1 Secure st. 6.1 Secure st. 5.1 Secure st. 4.1 Secure st. 3.0 Secure st. 2.0 Secure st. 1.0 Secure st. 0.0 Secure st. 7.0 Secure st. 6.0 Secure st. 5.0 Secure st. 4.0 Direction 7.0 Direction 6.0 Direction 5.0 Direction 4.0 Direction 3.0 Direction 2.0 Direction 1.0 Direction 0.0 Direction 7.1 Direction 6.1 Direction 5.1 Direction 4.1 Direction 3.1 Direction 2.1 Direction 1.1 Direction 0.1 Balluff Network Interface / IOLink 4 IOLink interface Port direction Byte 0 Byte 1 Direction port (x): x.0: Pin 4, x.1: Pin 2 Direction 0: Input 1: Output Secure status Pin 4 Byte 0 Byte 1 Secure status port (x) 00 0 01 1 10 Last status 11 Not defined Secure status Pin 2 Byte 0 Byte 1 Secure status port (x) 00 0 01 1 10 Last status 11 Not defined Sp. monitoring Byte 0 Byte 1 Short circuit on Port x between Pin 1 und Pin 3 Short circuit Port x = 1 where x=0...7 Actuator short circuit Byte 4 Byte 5 Actuator short circuit at signal port on port x Short circuit port x.0 = Pin 4 Short circuit port x.1 = Pin 2 www.balluff.com 11

Warning port 7.0 Warning port 6.0 Warning port 5.0 Warning port 4.0 Warning port 3.0 Warning port 2.0 Warning port 1.0 Warning port 0.0 Warning port 7.1 Warning port 6.1 Warning port 5.1 Warning port 4.1 Warning port 3.1 Warning port 2.1 Warning port 1.1 Warning port 0.1 Balluff Network Interface / IOLink 4 IOLink interface Actuator warning Byte 6 Byte 7 Actuator warning at signal port on port x Warning port x.0 = Pin 4 Warning port x.1 = Pin 2 Identification Byte 0 Byte 1 Identification byte 0 Identification byte 1 Byte 2 Byte 3 Identification byte 2** Identification byte 3** **Only in case of BNI IOL104S01Z012C02 4.5 Error Error Code Additional Code Device application error Index not available 0x80 0x11 Device application error Subindex not available 0x80 0x12 Device application error Value out of range 0x80 0x30 4.6 Events Class / Qualifier Mode Type Instance Code ( high + low) Appears Error AL Device Hardware Supply Supply low voltage US1 0xC0 0x30 0x03 0x5000 0x0100 0x0010 0x0002 0xF3 0x5112 Disappears Error AL Device Hardware Supply Supply low voltage US1 0x80 0x30 0x03 0x5000 0x0100 0x0010 0x0002 0xB3 0x5112 Appears Error AL Device Hardware Supply Supply low voltage UA 0xC0 0x30 0x03 0x5000 0x0100 0x0010 0x0004 0xF3 0x5114 Disappears Error AL Device Hardware Supply Supply low voltage UA 0x80 0x30 0x03 0x5000 0x0100 0x0010 0x0004 0xB3 0x5114 Appears Error AL Device Hardware Supply Supply low voltage US2 0xC0 0x30 0x03 0x5000 0x0100 0x0010 0x0005 0xF3 0x5115 Disappears Error AL Device Hardware Supply Supply low voltage US2 0x80 0x30 0x03 0x5000 0x0100 0x0010 0x0005 0xB3 0x5115 Appears Error AL Device Hardware Supply Supply periphery 0xC0 0x30 0x03 0x5000 0x0100 0x0060 0xF3 0x5160 Disappears Error AL Device Hardware Supply Supply periphery 0x80 0x30 0x03 0x5000 0x0100 0x0060 0xB3 0x5160 Appears Error AL Device Hardware Power Output Stages 0xC0 0x30 0x03 0x5000 0x0400 0x0010 0xF3 0x5410 Disappears Error AL Device Hardware Power Output Stages 0x80 0x30 0x03 0x5000 0x0400 0x0010 0xB3 0x5410 www.balluff.com 12

Balluff Network Interface / IOLink 5 Technical data 5.1 Dimensions Figure 51: Dimensions BNI IOL...Z012 & BNI IOL...Z013 5.2 Mechanical Housing material Diecast zinc housing data IOLink port M12, A coded, male Power supply 7/8 male, 5poles I/Oports M12, female, 5poles Enclosure rating per IEC 60529 IP 67 (only when plugged in and threaded in) Dimension (W x H x D in mm) 68 x 181,5 x 31,8 (32,4) Weight ca. 500 gr. 5.3 Electrical data Operating conditions 18...30.2 V DC, per EN 611312 Ripple < 1% Current draw without load <= 90 ma 5.4 Operating Operating temperature 5 C... 70 C conditions Storage temperature 25 C... 70 C EMC EN 6100042/3/4/5/6 Severity level 2B/3A/4B/2B/3A Shock / vibration EN 6006826, EN 60068227 EN 60068229, EN 60068264 www.balluff.com 13

Balluff Network Interface / IOLink 5 Technical data 5.5 LED indicators Port/Pin LED: Status Input / Output ports LED 16, Status LED Figure 52: LED Indicators Status LEDs BNI IOL104S01Z012C01 / BNI IOL104S01Z012C02 LED Indicator Function LED 1 Green / Red Supply Sensors & Module ok / under voltage LED 6 Green / Green flashing Communication error / communication ok BNI IOL302S01Z013C01 LED Indicator Function LED 1 Green / Red Supply Module OK/ Under voltage LED 3 Green / Red Supply actuators Ok/ under voltage LED 5 Green / Red Supply Sensors Ok / under voltage LED 6 Green / Green flashing Communication error / communication ok LED I/Oports Standard Indicator Function LED Pin 2 / Pin 4 Out Input signal / Output signal = 0 Yellow, static Input signal / Output signal = 1 Red Input port: Short circuit Output port: Imax www.balluff.com 14

Balluff Network Interface / IOLink Appendix Product ordering code Balluff Network Interface IOLink interface Functions 104 = 16 dig. Inputs 302 = 16 dig. Inputs/Outputs Versions S01 = Single channel monitoring BNI IOL104S01Z01xC0x Mechanical design Z012 = Diecast zinc housing, matte nickel plated Bus connection and power supply 1xM12 external thread Iports: 8xM12, female, 5poles, internal thread Z013 = Diecast zinc housing, matte nickel plated Bus connection 1xM12 male, external thread power supply 7/8 male, external thread I/Oports: 8xM12, female, 5poles, internal thread Extra functions C01 = Identification, 2 byte C02 = Identification, 4 byte Order information Product ordering code Order code BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 BNI003T BNI005P BNI0048 Scope of delivery BNI IOL.consists of the following components: IOModule 4 filler plugs M12 Ground connectionband Screw M4x6 20 Labels User s Guide www.balluff.com 15

Balluff Network Interface / IOLink Notes www.balluff.com 16

Balluff Network Interface / IOLink Notes www.balluff.com 17

Balluff Network Interface / IOLink Notes www.balluff.com 18

Nr. 877483 E Edition 1205 Revised Edition 1201 Subject to modification Balluff Network Interface / IOLink www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Tel. +49 7158 1730 Fax +49 www.balluff.com 7158 5010 19 balluff@balluff.de