One Stop Cooling Solution. Ben Tam Business Development Manager

Similar documents
Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Rittal Cooling Solutions A. Tropp

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Close Coupled Cooling for Datacentres

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Thermal management. Thermal management

Power and Cooling for Ultra-High Density Racks and Blade Servers

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

APC APPLICATION NOTE #146

Switch to Perfection

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Close-coupled cooling

APC APPLICATION NOTE #74

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

ENCLOSURE HEAT DISSIPATION

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Total Modular Data Centre Solutions

APC InfraStruXure Solution Overview

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

How to Increase Data Center Efficiency

INNOVATE DESIGN APPLY.

APC by Schneider Electric Elite Data Centre Partner

INNOVATE DESIGN APPLY.

Design and Installation Challenges: Aisle Containment Systems

APC APPLICATION NOTE #114

Reducing Energy Consumption with

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

Reducing Data Center Cooling Costs through Airflow Containment

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Virtualization and consolidation

How to Sell APC s Cisco Approved Solution for Nexus 7018

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

IT Air Conditioning Units

Green IT and Green DC

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Liquid Cooling Package LCP Cooling Systems

MS Noise 9210 Active 24U Acoustic Rack

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

NetShelter CX Technical Guide

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Data Center Design: Power, Cooling & Management

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

RE Series Rack from Eaton Product Presentation

MS Noise 9210 Passive 24U Acoustic Rack

LCP Hybrid Efficient performance with heat pipe technology

Power & Cooling Considerations for Virtualized Environments

Efficiency of Data Center cooling

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

1.0 Executive Summary

Cooling Solutions & Considerations for High Performance Computers

Improving Rack Cooling Performance Using Blanking Panels

Rittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency By: Daniel Kennedy

FREEING HPC FROM THE DATACENTRE

ECOBAY: Closed loop water cooled server cabinet for data centers

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Rethinking Datacenter Cooling

1.866.TRY.GLCC WeRackYourWorld.com

Liebert DCW CATALOGUE

SmartMod Intelligent, Integrated Infrastructure for the Data Center

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

NetShelter CX Performance Guide

Planning a Green Datacenter

Data Centre In A Box

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

A Green Approach. Thermal

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

84 kw, Tier 3, Direct Expansion, 937 ft 2

Data Center Design: Power, Cooling & Management

Recapture Capacity for Existing. and Airflow Optimization

MSYS 4480 AC Systems Winter 2015

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

EF-Series EuroFrame Gen 2 Cabinet System

ENCLOSURE THERMAL TESTING HEAT REMOVAL IN THE REAL WORLD

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Eaton 93PM UPS Efficient. Scalable. Innovative.

Green Data Centers A Guideline

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Ten Cooling Solutions to Support High- Density Server Deployment

Precision Cooling. Precision Cooling Advantages

Trends in Data Center Energy Efficiency

The Energy. David L. Moss Dell Data Center Infrastructure

Transcription:

One Stop Cooling Solution Ben Tam Business Development Manager

Agenda One Stop Cooling Solution Challenges Customers Are Facing Today Rack / Row / Room Solution Keynotes New Product Launch Slide 2 2

One Stop Cooling Solution CRAC InRow (ISX) Slide 3 3

One Stop Cooling Solution Amico Leonardo Loenardo Max Wall-mounted Monoblock Unisplit InRoom SC Room Air Distribution Room Row Inrow SC model InRow Direct Expansion InRow Chilled Water Thermal Containment Access Flooring Rack Air Distribution InRack direct expansion Rack Building Technical Chillers Free Cooling Chillers and Economizers Ecoflair Heat Rejections 4

One Stop Cooling Solution Building Room Cooling Rack Cooling Server Row Cooling 5

Challenges Customers Are Facing Today Remove Hot Spot Elimination of hot spots within room and rack High Density Application Deployment of high heat IT equipment Dynamic cooling Because of virtualization Performance Ensure stable inlet temperatures to IT equipment TCO (CAPEX and OPEX) Minimize total cost of ownership Flexibility To add cooling as the demand increases Minimum floor space Limited space for further expansion Slide 6 6

Room Cooling Solution 7

Room Cooling Solution CRAC When to select Room Cooling Low density environment (<5kW per rack) Evenly distributed load Mega data center Legacy design Slide 8 8

Room Cooling Solution CRAC Remove Hot Spot HD Application Dynamic cooling Performance CAPEX OPEX Flexibility Min. space Thermal Containment Slide 9 9

Room Solution CRAC Main features Range from 6 to 20kW Upflow / downflow Air-cool / water-cool / chilled-water Only 450mm depth Group control Alert thru network Amico Slide 10 10

Row Cooling Solution 11

Row Cooling Solution InRow Cooling with Thermal Containment Hot Aisle Ceiling Tiles/Cable Trough Seals in hot air, prevents mixing with room air InRow Cooling InRow Air Conditioner Cools hot chamber air Slide 12 12

Row Cooling Solution When to select Row Cooling SME market Small to Medium data center Low density to high density environment Raised floor or no raised floor environment Looking for ultra high efficient solution Consider TCO, not only CAPEX Looking for minimal and unified design Slide 13 13

Row Cooling Solution InRow Cooling with Thermal Containment Hot Aisle Ceiling Tiles/Cable Trough Seals in hot air, prevents mixing with room air Remove Hot Spot HD Application Dynamic cooling Performance CAPEX OPEX InRow Cooling InRow Air Conditioner Cools hot chamber air Flexibility Min. space Slide 14 14

Row Cooling Solution Overview Slide 15 15

Row Cooling Solution InRow Cooling Unit 300mm width InRow Main features Up to 30kW Air-cool / water-cool / chilled-water cool/selfcontained Small footprint Server inlet temperature control Variable fan speed Hot-swappable fan Slide 16 16

Row Cooling Solution InRow Cooling Unit Main features Up to 60kW Optional with humidifier and heater Air-cool / water-cool / chilled-water cool Small footprint Server inlet temperature control Variable fan speed by EC fan 600mm width InRow Slide 17 17

Rack Cooling Solution 18

Rack Cooling Solution Slide 19 19

Rack Cooling Solution Enhance Air Distribution and Hot Air Removal Unit Active Floor Module Rack Air Distribution Unit Rack Side Air Distribution Unit Air Removal Unit (ARU) Slide 20 20

Rack Cooling Solution Enhance Air Distribution and Hot Air Removal Slide 21 21

Rack Cooling Solution Enhance Air Distribution and Hot Air Removal When to select Rack Air Flow Distribution Unit Base cool is in place and with enough cooling capacity Small to Mega data center No more space for expansion Slow air flow at server Hot Spot Slide 22 22

Rack Cooling Solution Enhance Air Distribution and Hot Air Removal Remove Hot Spot HD Application Dynamic cooling Performance CAPEX OPEX Flexibility Min. space Slide 23 23

Rack Cooling Solution Rack Air Containment Rack Air Containment InRow Cooling IR Top View NetShelter SX Slide 24 24

Rack Solution Rack Air Containment 5 to 18kW per rack without redundancy 5 to 18kW per rack with 100% redundancy 2.5 to 9kW per rack with 100% redundancy 5 to 18kW per rack with 50% redundancy 7.5 to 27kW per rack with 30% redundancy 29kW per rack without redundancy 29kW per rack with 100% redundancy 14.5 kw per rack with 100% redundancy Slide 25 25

Rack Solution Rack Air Containment When to select Rack Air Containment SME market Just few server racks No dedicated room for IT equipment Low or high density application Looking for minimal and unified design Slide 26 26

Rack Solution Rack Air Containment Remove Hot Spot HD Application Dynamic cooling Performance CAPEX OPEX Flexibility Min. space Slide 27 27

Keynotes Start from today. To sell your customer Schneider Electric provides One Stop Cooling Solution Full range of products: Rack, Row and Room Cooling High density application Row Cooling and Active Floor High efficient solution as Schneider Electric is the global specialist in energy management Full pre-sales and technical support on cooling business Slide 28 28

Two More Things 29

Incentives 30

Incentives Offer voucher for the top 3 salesman (accumulative order) 1 st Prize HKD20,000 2 nd Prize HKD12,000 3 rd Prize HKD8,000 Notes: The accumulative order shall be over HKD300,000 for all cooling equipment End date: Order intake from Mar 1 to Aug 31 Slide 31 31

New Product Launch 32

Netshelter CX Description A Soundproofed Server Room in a Box which allows IT deployment where ever and whenever it is needed, saving space, cost and deployment time. 18U 24U 38U 33

Netshelter CX Integrated Features 1. Soundproofed enclosure 2. Integrated ventilation fans 3. Power distribution included 8 5 1 4. Mobile, on heavy-duty castors 5. EIA spec 4 post 19-inch rack 6. Lockable front doors 3 6 7. Front & rear accessory rails, used for cable management 7 8. Detachable side panels & rear fanmodules for easy access. 2 4 3 2 34

Netshelter CX Applications 1. Corporate (Branch office) 2. Retail branches 3. SME/SMB 4. Finance (inc Banks) 5. Pro AV & Media 6. Schools (mobile computing) 7. Home offices 8. Government (local offices) 9. Conferencing 10. Health (Medical Offices) 11. Start-ups 12. Interior Design Sector 35

Time for Q&A 36