Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

Similar documents
TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

Transitioning from pencil beam to Monte Carlo for electron dose calculations

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

ADVANCING CANCER TREATMENT

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

FAST, precise. qa software

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

ADVANCING CANCER TREATMENT

Quick Reference Datasheet For All RIT113 Packages

Machine and Physics Data Guide

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

Basic Radiation Oncology Physics

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

DAILY LINAC QA BEAM QA

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Raising the Bar in IMRT QA

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Michael Speiser, Ph.D.

3DVH FAQs. What is PDP questions

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

Clinical implementation of photon beam flatness measurements to verify beam quality

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free beams

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Initial Clinical Experience with 3D Surface Image Guidance

TG-148 overview. Introduction. System Overview. System Overview. QA for Helical Tomotherapy: Report of the AAPM Task Group 148. Conflict of Interest:

Dynalog data tool for IMRT plan verification

Calibration and quality assurance for rounded leaf-end MLC systems

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

Chapter 9 Field Shaping: Scanning Beam

Outline. Outline 7/24/2014. Fast, near real-time, Monte Carlo dose calculations using GPU. Xun Jia Ph.D. GPU Monte Carlo. Clinical Applications

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Table of Contents. About AQUA

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Photon beam dose distributions in 2D

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

Real-time monitoring of linac performance using RT plans and logfiles

Dose Calculation and Optimization Algorithms: A Clinical Perspective

AAPM Standard of Practice: CT Protocol Review Physicist

Proton dose calculation algorithms and configuration data

UNCOMPROMISING QUALITY

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

ph fax Deming Way Middleton WI USA

Monitor Unit (MU) Calculation

Validation of a GPU-Based 3D dose calculator for modulated beams

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

LUP. Lund University Publications. Institutional Repository of Lund University

Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

CLINICAL ASPECTS OF COMPACT GANTRY DESIGNS

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

Basics of treatment planning II

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Photon Dose Algorithms and Physics Data Modeling in modern RTP

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

A SYSTEM OF DOSIMETRIC CALCULATIONS

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Using a research real-time control interface to go beyond dynamic MLC tracking

Advanced Radiotherapy

PyCMSXiO: an external interface to script treatment plans for the Elekta CMS XiO treatment planning system

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Agility MLC transmission optimization in the Monaco treatment planning system

Monte Carlo Treatment Planning: Implementation of Clinical Systems

The MSKCC Approach to IMRT. Outline

VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning. Rajat Kudchadker, Ph.D. Associate Professor

How would, or how does, the patient position (chin extended) affect your beam arrangement?

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1

Calculation algorithms in radiation therapy treatment planning systems

Automated Quality Assurance for Image-Guided Radiation Therapy

Calculating percent depth dose with the electron pencilbeam redefinition algorithm

Medical Dosimetry 37 (2012) Medical Dosimetry. journal homepage:

An Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields

Radiation therapy treatment plan optimization

Follow this and additional works at:

Modulation factors calculated with an EPID-derived MLC fluence model to streamline IMRT/VMAT second checks

Transcription:

AAPM MEDICAL PHYSICS PRACTICE GUIDELINE # : Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams Jennifer Smilowitz (Chair), University of Wisconsin-Madison Indra Das, Indiana University School of Medicine Vladimir Feygelman, Moffitt Cancer Center Benedick Fraass, Cedars-Sinai Medical Center Mark Geurts, University of Wisconsin-Madison Stephen Kry, MD Anderson Ingrid Marshall, Medical University of South Carolina Dimitris Mihailidis, Charleston Radiation Therapy Center Zoubir Ouhib, Lynne Regional Cancer Center Timothy Ritter, University of Michigan Michael Snyder, Wayne State University Lynne Fairobent, AAPM Staff University of Wisconsin SCHOOL OF MEDICINE AND PUBLIC HEALTH AAPM Spring Clinical Meeting, Denver March 4 Outline: follow outline of MPPG (plus rationale & some implementation experiences). Introduction a. Goals b. Tolerances and evaluation criteria c. Scope/exclusions. Staff qualifications 3. Data acquisition 4. Model within TPS software. Photon beams: basic dose algorithm validation MatLab code for D gamma analysis Trilogy: absolute dose verification, large field/off axis MLC tests TomoTherapy: tomophants 6. Photon beams: heterogeneity correction validation Clinac: CIRMS phantom 7. Photon beams: IMRT/VMAT dose validation TomoTherapy TG 9 tests and clinical case 8. Electron beams 9. Routine QA (downloadable datasets) What to do/check? This report only cover dose calculation, the term commissioning includes beam data acquisition, modeling, and validation. Figure : Workflow of TPS dose algorithm commissioning, validation and routine QA. The numbers refer to sections of this report. Goals While the implementation of robust and comprehensive QA programs recommended in other AAPM reports is strongly encouraged, the overall objective of this MPPG is to provide an overview of the minimum requirements for TPS dose algorithm commissioning and QA in a clinical setting. Specific goals for this report are to: Clearly identify and reference applicable portions of existing AAPM reports and peer-reviewed articles for established commissioning components. Provide updated guidelines on technologies that have emerged since the publication of previous reports. Provide guidance on validation tests for dose accuracy and constancy (select downloadable datasets/contours & beam parameters are provided for optional use). Provide guidance on typical achievable tolerances and evaluation criteria for clinical implementation. Provide a checklist for commissioning processes and associated documentation. Tolerances & Evaluation Criteria ( tier approach ) Wanted to state minimum acceptable tolerance for TPS basic dose calculation: The tolerances for the basic photon tests are widely accepted as minimum criteria for static photon beams under conditions of charged particle equilibrium. Wanted to push the limit on some evaluation criteria to find limitations of dose calculations: Given that there is not widely accepted minimum tolerance for the other verification tests in this MPPG, (including those for VMAT/IMRT), those evaluation criteria must not be interpreted as mandatory or regulatory tolerances. Rather, they are values defined as points for further investigation, possible improvement, and resolution. Did not want to state or use any minimum tolerance values not widely accepted/published: All the tolerances and criteria in this report are based on a combination of published guidelines, the dosimetric audits performed by the Radiological Physics Center, and the experience of authors. Users are encouraged to not only meet these tolerances, but also strive to achieve dosimetric agreement comparable to that reported in the literature for their particular algorithm. Scope/exclusions Title: Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams The scope of this report is limited to the commissioning and QA of the beam modeling and calculation portion of a TPS where: External photon and electron treatment beams are delivered at typical SSDs using a gantry mounted radiation source including conventional and small fields used in IMRT, VMAT, helical tomotherapy delivery, and SRS/SBRT (still up for discussion). Modern dose algorithms are utilized including corrections for tissue heterogeneity. The Multi-Leaf Collimator (MLC) is used as the primary method of shaping the beam aperture for treatments. (individually fabricated IMRT modifiers, cones still up for discussion) Excludes: (not an exhaustive list, and not all written in document) Non-dosimetric components of system, e.g.: DVH, leaf sequences, contours, image registration Brachytherapy Proton therapy Non-commercial planning systems Radiation delivered by robots

Outline: follow outline of MPPG (plus rationale & some implementation experiences). Introduction a. Goals b. Tolerances and evaluation criteria c. Scope/exclusions. Staff qualifications 3. Data acquisition 4. Model within TPS software. Photon beams: basic dose algorithm validation MatLab code for D gamma analysis Trilogy: absolute dose verification, large field/off axis MLC tests TomoTherapy: tomophants 6. Photon beams: heterogeneity correction validation Clinac: CIRMS phantom 7. Photon beams: IMRT/VMAT dose validation TomoTherapy TG 9 tests and clinical case 8. Electron beams 9. Routine QA (downloadable datasets) Data Acquisition Question What data do you use when commissioning a new dose algorithm?. Collect data according to vendors guidelines. Collect some of the vendor recommended data but not all 3. Collect all required data and more 4. Use golden beam data. Hey, I thought this wasn t a SAM session. Staff, Data, Model Staff qualifications QMP, defer to supervision MPPG Data acquisition defer to TPS manuals for all required data (water tank, and in air for MC) & refer to TG 6. An equipment list/ summary on small field/mlc data acquisition is included: PDD and OF with a small volume detector down to at least x cm MLC intra and inter-leaf transmission and leaf gap: Large chamber if an average intra- and inter-leaf value is specified. Separate measurements, use small chamber under the leaf and film for inter-leaf leakage measurements Measure leaf-end penumbra with a small detector (such as a diode or micro-chamber) to avoid volume-averaging effects Leaf timing for binary MLC systems should be verified using film or exit detector measurements Model refer to manual, iterate as needed using results from validation testing Outline: follow outline of MPPG (plus rationale & some implementation experiences). Introduction a. Goals b. Tolerances and evaluation criteria c. Scope/exclusions. Staff qualifications 3. Data acquisition 4. Model within TPS software. Photon beams: basic dose algorithm validation MatLab code for D gamma analysis Trilogy: absolute dose verification, large field/off axis MLC tests TomoTherapy: tomophants 6. Photon beams: heterogeneity correction validation Clinac: CIRMS phantom 7. Photon beams: IMRT/VMAT dose validation TomoTherapy TG 9 tests and clinical case 8. Electron beam validation 9. Routine QA (downloadable datasets) Validation Question What type of dose algorithm validation do you do as part of the commissioning process?. None. Routine patient specific DQA serves as validation 3. In-house test suite (chamber, array, films etc ) 4. Peer review audit (colleague or RPC). Combination of 3 and 4 Validation Measurements Water tank, ion chambers & diodes Custom phantom IMRT DQA Device (i.e. Delta4) Report was written such that user has freedom to use any suitable/available combination of phantoms and detectors. Combination of in-house and external audits It is recommended to take data at time of commissioning. This diagram shows a common set of tools (and what we are using at UW.)

. Basic Validation: Photon beams Photon beams: TPS model comparison (.-.3) Section (Photons in homogeneous media) has sets of tests:.-.3: sanity check of commission data physics module planning module and TG calibration value.4-.9: test fields that were not used in commissioning. Compare measured and calculated dose distribution. Tests should be run for each unique configured beam (energy and wedge) No additional measurements beyond commissioning data needed for these tests. Implementation:.Dose in test plan vs. TPS calibration (.% tolerance) Photon beams: Basic tests (.4-.) Part of an exercise to confirm match between two Varian s 9 cm SSD D = cm *Measure: high dose, penumbra, and low dose tail regions at various depths **Tests.4-.8 are intended for each open and (hard) wedged field. Nonphysical wedges are considered an extension of the corresponding open field in terms of spectra and only require the addition of Test.9 [7] International Atomic Energy Agency, "Commissioning and quality assurance of computerized planning systems for radiation treatment of cancer," Vienna, 4. Accuracy question How accurate is your worst off axis relative dose calculation?. %. % 3. 3% 4. 4%. % Accuracy question How accurate is your worst off axis relative dose calculation with a wedge in place?. %. % 3. 3% 4. 4%. % 3

Section : Basic photon tolerances Implementation:. Large MLC shaped field with extensive blocking (γ analysis) Example of a test pattern that tests many things at once: Off axis PDD ( ), 3 cross profiles ( cm, cm, cm) and in line profile ( cm) for open and wedge fields 6 wedge, toe in Implementation:. Large MLC shaped field with extensive blocking (γ analysis) D analysis open source MatLab code MV 6 wedge d= cm d= cm d= cm Save scan data in Excel and output dicom dose files from TPS (note dose grid origin and resolution). Script/detailed users manual will be available on the UW Open Source Medical Devices website and code revision history at github: http://discovery.wisc.edu/home/town-center/programs--events/recurringconferences/open-source-medical-devices/ https://github.com/bredfeldt/mppg Code interpolates data, shifts for best agreement and does gamma analysis according to Low et al, Med. Phys (), 988 Validate gamma calculation with 3%/3mm threshold Create simulated dose profiles A and B A = dose ramp with slope =.3 Gy/3mm B = A +.3*sqrt() Input A and B into gamma calculation Verify that gamma = at all positions Thanks to MatLab Master Jeremy Bredtfeldt! Calculation Test Case Calculation Test Results Min. γ will occur with a dose error is. () and position error is. (. dose Dose error Position error γ == (. ) (. ) +.3 3 and Relative Dose.9.9.8.8.7.7 A B calculated measured position Iso-γ contour.6.6. - -. - -... Position (cm) 4

Results from off axis PDD for open MV field %/.mm Results from off axis PDD for wedge MV field %/.mm PDD MV wdg PDD MV. One parameter change (off-axis) parameters change (off-axis & wedge) & Normalized Dose & Normalized Dose..8.6.4.8.6.4.. 3 3 Problem in buildup region. Adjust model of the electron contamination? Results from d= cm inline profile for 3 wedged MV field, γ = 3%/3mm 3 wdg.4 Scan direction. & Normalized Dose & Normalized Dose.6 3 3 Profile MV 3wdg MV @ cm. Results from d= cm inline profile for 3 wedged MV field, γ = %/3mm parameters change (off-axis, and wedge).8 Problem in buildup region. Adjust model of the electron contamination? Profile MV 3wdg MV @ cm. Depth (cm) Depth (cm) parameters change (off-axis, and wedge).8 3 wdg.6 Scan direction.4. Position (cm)..problem in leaf penumbra (T&G) region. Adjust leaf intra or inter leaf leakage model?. Problem with jaw closing to MLC defined edge? Position (cm) Results from d= cm crosline profile for 6 wedged MV field, γ = 3%/3mm Implementation: Basic test on TomoTherapy Profile MV 6wdg MV @ cm. Forward planned fields are not easily generated in tomo TomoPhants : set of standard plans with different jaw sizes (fixed and dynamic) run on cheese phantom with ion chambers for inline profiles (and Delta4 for volumetric DQA.) They are a good alternative to implementation of section tests dose profiles are extracted by Accuray and measured data is analyzed with excel sheets & Normalized Dose.8 6 wdg.6.4. Position (cm)

Implementation: TomoPhant results Same plan with helical and tomodirect, for each field size. Results: TomoDirect measured hotter than planned (compared to helical plans) cm FW plans were always hotter than planned (compared to other FW) ASL Ion chamber, error bars are 3% What can be done? Adjust JFOF (basically a collimator scatter output factor (Sc) table Heterogeneity questions Which algorithm is not acceptable for dose calculation for lung?. Pencil beam. Monte Carlo Max error =.% 3. Convolution superposition 4. Discreet ordinance (grid based Boltzman solver). All are acceptable Section 6: Heterogeneity Implementation : Heterogeneity tests (3% tolerance) Follow the methodology of the AAPM TG64. A CIRS xx cm3 Cube Plastic Water phantom ( Cube Phantom ) with low density wood (.7 g/cm3) inserts. Modern algorithms (C/S. MC, GBBS, no PB) Only test beyond heterogeneity (not in or at boundaries, areas at which it is difficult to measure) Only low density tissue Images from Vladimir Feygelman Section 7: IMRT/VMAT Verification IMRT DQA Question What gamma criteria do you use for patient specific delivery QA (DQA)?. %/mm. %/mm 3. 3%/3mm 4. 4%/4mm. I don t do patient specific DQA and/or I don t use gamma criteria for DQA analysis. 6

IMRT DQA Question What do you do when a case fails that criteria?. increase tolerance by %/mm. Re-measure 3. Re-plan 4. Pick tolerance so >9% pass and report tolerance values. My plans never fail MD Anderson Experience with failed DQA s 3%/ 3mm Film and ion chamber st Re-Measurement Passed: 7 nd Re-Measurement 3 rd or More Re- Measurements Passed: 7 Number of Plans Failing Absolute Dose: 3 Passed with Special Delivery: 6 Passed: Passed with Special Delivery: 3 Failed: 66 Failed: Passed with Special Delivery: 3 No Follow-Up Measurement: 47 No Follow-Up Measurement: Failed: No Follow-Up Measurement: 4 Only 3/3 failed cases were replanned! Extreme majority treated as is Thanks Stephen Kry IMRT/VMAT Validation Tests (section 7) Implemention: TG 9 C-shaped plan on tomo with Delta4 C-shape plan, on tomo Delta4 %mm (global) gamma analysis Use only detectors with >% signal Excellent results, % pass Downloadable data sets with plan instruction Section 8: Electron Beam Verification 7

Section 9 QA Annually or after major TPS upgrades Reference plans should be selected at the time of commissioning and then recalculated for routine QA comparison. For photons, representative plans for each configured beam should be chosen from Table 4 for static and wedge beams and Table 7 for IMRT/VMAT. Optionally, an additional thorax dataset with contours and suggested static beam parameters can be downloaded and used for some of these tests, (http://www.aapm.org/pubs/tg44/). A x cm field and a small field (e.g. x cm ) can be prescribed to the isocenter located in the center of the PTV. Wedged fields and dynamic arc plans can also be calculated on the thorax data set. For electrons, plans should be calculated for each energy using a heterogeneous dataset with reasonable surface curvature. The sample thorax dataset is also suitable for this test. Recommended plans also include extended distance and bolus verification. The routine QA re-calculation should agree with the reference dose calculation to within %/mm. A complete re-commissioning (including validation) may be required if more significant deviations are observed. Checklist to guide commissioning report Next steps. Respond to public comment reviewer comments Submit to JACMP await final review Continue implementation of MPPG on Varian, TomoTherapy and Elekta (AAPM annual meeting abstract) Fine tune gamma analysis in MatLab code, analyze remaining Trilogy and Infinity data Take heterogeneous and electron data Create test suite for each machine type (Pinnacle/Eclipse plans, R&V entry and scan Q s) Make gamma analysis code easily available (and easier data input) Thanks to my collaborators, and to you for your attention! All MPPG# members! UW clinical physicists who helped with implementation Adam Bayliss John Bayouth Ed Bender Jessica Miller UW Medical Physics graduate students Jeremy Bredtfeldt Sam Simiele 8