Operator Interfaces Introduction & Selection Guide SELECTION GUIDE INTRODUCTION UCT-31P

Similar documents
Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

Process displays For current and voltage

PROGRAMMABLE MARQUEE DISPLAYS

Programmable Relay ZEN V2 Units

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Counting On Your Process Preset Counters

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

02/11/2015

Bulletin 2707 DTAM Plus Operator Interface Product Data

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Displays Transducers. Displays and transducers

PROGRAMMABLE MESSAGE DISPLAYS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

TABLE OF CONTENTS. Communication Functions

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Absolute Encoders Multiturn

Product data sheet accessories control and regulation Accessories AIRWIN

Product Description. Contents. Fusion Series. New Information December 2003

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

MODEL: R2K-1 SEN TRONIC AG. R2K Series

2. Actuator B: Ball type P: Pin type F: Flat type

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Supply voltage. Input current. Encoder supply. Memory

Digital Indicator Solutions

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Temperature Switches

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

TWDLCDA40DRF. Price* : USD

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

02/11/2015

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

TWDLCAA24DRF extendable PLC base Twido V AC supply - 14 I 24 V DC - 10 O relay

JUMO Quantum PID100/PID200/PID300

Magnetically Actuated Safety Interlock Switches

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Process controllers for the meat processing industry

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

TWDLCDA40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

TWDLMDA20DRT extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state and relay

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

LS 5000 series Vibration Level Switch for liquids

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Programmable Logic Controllers

TWDLMDA20DTK extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state

Indicomp 4 Bargraph Indicator

E-STOP relays, safety gate monitors

Universal power supply

Classification Enclosure rating Input voltage Type of

TWDLCDE40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

TWDLMDA20DRT extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state and relay

Manual Industry Interfaces

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

PointMaster 100. Multipoint Recorder 10/ EN

Display and Monitoing Units

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

TWDLCAA24DRF extendable PLC base Twido V AC supply - 14 I 24 V DC - 10 O relay

TWDLCDA10DRF compact PLC base Twido - 24 V DC supply - 6 I 24 V DC - 4 O relay

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

signo 727 SSI operating instructions

High Voltage DC Meter

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TWDLMDA20DRT extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state and relay

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Solid State Remote Power Controller E /627

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Operating instructions. Switching amplifier DN0210 DN / / 2015

Trident and Trident X2 Digital Process and Temperature Panel Meter

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

HIGH-VOLTAGE DC METER

Expansion Module HZS 541-1S

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

JUMO mtron T Measuring, Control, and Automation System

RS485 MODBUS Module 8I8O

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Simple solutions for control technology

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Energy Management Modular Energy meters Type EM2-96

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Transcription:

Introduction & Selection Guide UCT-30 UCT-31 UCT-31P UCT-34 UCT-34P UCT-36 INTRODUCTION Brodersen message displays and operator panels provide the operator with relevant information about e.g. operating conditions and actual measured variables, when the plant is operating normally, and alerts the operator in case of a malfunction situation. The information is transferred from a PLC or other controller and converted to clear, simple messages on the display - as fixed texts or a combination of fixed text and current measured variable. Operator panels have 2 lines of text with 20 characters and a capacity of up to 200 messages. Each message can include up to 16 dynamic digits. As and where desired, the operator can key his way directly into the PLC and change parameters or implement pre-programmed functions - and here it is possible to choose between panels with 4 or 24 keys. Operator panels are supplied with different options for connection to the controller - e.g. with a parallel interface for direct connection to the digital outputs on the controller, with a serial interface including drivers to most PLCs or with VT100 terminal emulation. Programming of texts is perfectly straightforward and is done either with an ordinary PC or by connecting a PC keyboard directly. If display message printouts including the time are required for documentation or data-logging purposes, a printer can be connected. TYPE UCT-33 UCT-36 UCT-30 UCT-31 UCT-31P UCT-35 UCT-35P UCT-32 UCT-32P UCT-35 UCT-35P UCT-32 UCT-32P UCT-33 Accessories SELECTION GUIDE Parallel interface Ÿ Serial interface Number of keys UCT-34 24 UCT-34P 24 4 24 4 4 4 4 UCC-201: 2.5 m Variable digits Real-time clock & calendar Acoustic alert Printer output 90 90 92 94 94 Page... 96 96 98 98 98 98 ACC... UCT-32/34 UCT-35/35P UCT-31/31P UCT-30 UCT-33/36 INTRO... The elegant design and small dimensions of the Brodersen message displays have been tailor-made for incorporation in a console or control panel. Brodersen also manufactures message displays and operator panels with BITBUS interface and industrial PCs. 97

VT100 Terminal Emulation UCT-33/36 UCT-33 UCT-36 DESCRIPTION REAR PANEL/CONNECTIONS UCT-33/36 message display and operator panel is compatible with a VT100 terminal. Due to physical and functional limitations only a subset of the VT100 control commands are applicable to this device. UCT-33/36 can be used as a nonintelligent man machine interface in industrial installations. The display acts as an output device for a "host", e.g. a PLC or a computer - data coming from the host is displayed on the screen. Simultaneously the keypad can be used as an input device to the host - information entered through the keyboard is sent to the host. The terminal utilizes a serial RS232C data interface to transfer data between the terminal and the host. UCT-33 has 4 keys, UCT-36 has 24 keys on the front panel, both versions are equipped with a 2 x 20 character VFD display. The units have IP65 front sealing and are designed for mounting in installation panels. The dimensions corresponds to DIN standard for panel meters etc. Versions are available for AC/DC supply voltage. 1 2 3 4 5 1. RS232C connector, 9-pole sub-d. 2. Code switch. 3. Fuse. 4. Mains supply, plug-in screw terminals. 5. Ground terminal. VERSIONS/ORDERING CODES Type: UCT-36 230 Number of keys: 4 keys. UCT-33 24 keys. UCT-36 12-48V AC/DC 924 110-240V AC 230 98

VT100 Terminal Emulation UCT-33/36 TECHNICAL DATA Display: Display field: Height of characters: Intensity: Keypad: VFD type, 2 x 20 characters, 5 x 7 dot matrix. Readable at a distance up to 3 m. 125 x 22 mm. 5 mm. Selectable, 4 levels. UCT-33: 4 keys. UCT-36: 24 keys. Tactile feedback type. Acoustic feedback selectable Serial interface: EIA, RS 232C. Mode: Full duplex. Speed: 300, 1200, 2400, 4800, 9600 Baud. Code: ASCII. Format: Asynchronous. Character size: 7 or 8 bit. Parity: Even, odd or none. Synchronization: XON / XOFF. Control: Subset of VT100 (ANSI) 9-pole sub-d (male). Mains frequency: 12-48VAC/DC(10.5-58V). 110-240V AC (90-265V). 40-60Hz. Consumption: Approx. 10W. Ambient temperature:-20 to +50 C. Protection: EMC: Isolation: Mains: Front: IP54. Rear: IP20. According to EN50081-1, EN50082-2. 4kV AC. according to EN60950 class II. MECHANICAL DIMENSIONS UCT-36: 96 UCT-33: 48 192 9 96 10 ACC... UCT-32/34 UCT-35/35P UCT-31/31P UCT-30 UCT-33/36 INTRO... Dimensions: Front: UCT-33: UCT-36: Depth: Panel cut-out: Housing: 192 x 48 mm according to DIN43700. 192 x 96 mm according to DIN43700. 96 mm + connectors (10 mm) + front (9 mm). 186 x 45 mm. Front: Plastic. Rear: Anodized aluminium. Weight: Approx. 600 g. 99

Parallel Interface UCT-30 UCT-30 DESCRIPTION REAR PANEL/CONNECTIONS General purpose message display for front panel mounting with up to 100 prestored messages. Each message contains 2 lines of text with up to 20 characters per line. The message display can easily be integrated into any PLC controlled system as the message selection is controlled by 9 (or less) standard outputs on the PLC. Versions available for direct mains supply or battery supply. 1 2 3 4 5 6 1. Parallel inputs, plug-in screw terminals. 2. Code switch. 3. Connector for external keyboard or PC. 4. Fuse. 5. Mains supply, plug-in screw terminals. 6. Ground terminal. VERSIONS/ORDERING CODES Type: UCT-30 230 With 100 messages. UCT-30 12-48V AC/DC 924 110-240V AC 230 100

Parallel Interface UCT-30 TECHNICAL DATA Display: Display field: Height of characters: Intensity: Messages: Character sets: Inputs: Input voltage: Input current: Input delay: Built-in DC supply: Programming: RS232C format: Mains frequency: VFD type, 2 x 20 characters, 5 x 7 dot matrix. Readable at a distance up to 3 m. 125 x 22 mm. 5 mm. Programmable, 4 levels. Up to 100 messages. 40 characters each. Messages are selected by an 8 bit binary co-de at the parallel input. Messages are stored in a built-in memory (EEPROM) independent of supply voltage. Danish, UK, German, Swedish. Danish CP850, UK CP850, Swedish CP850, German CP850 Swiss/1 CP850, French CP850 Special character set available on request. 9 optocoupled inputs, PNP, NPN or relay controllable. 10-30V DC (active). Max. 3V DC (non active). 12V DC: Typically 3mA. 24V DC: Typically 6mA. Typically 1ms (noise suppression). 12V DC nom. max. 100mA. Standard XT/AT-compatible keyboards or PC via RS232C. 1200 Baud, ASCII, 1 start bit, 8 bit, no parity, 1 stop bit. 7-pole female DIN connector (XT/AT compatible). 12-48V AC/DC (10.5-58V). 110-240V AC (90-265V). 40-60Hz. MECHANICAL DIMENSIONS 48 192 9 96 10 ACC... UCT-32/34 UCT-35/35P UCT-31/31P UCT-30 UCT-33/36 INTRO... Consumption: Approx. 10W. Ambient temperature: -20 to +50 C. Protection: EMC: Isolation: Dimensions: Front: Depth: Panel cut-out: Housing: Front: IP54. Rear: IP20. According to EN50081-1, EN50082-2. Mains: 4kV AC according to EN60950. Parallel input to electronics: 2kV AC. 192 x 48 mm according to DIN43700. 96 mm + connectors (10 mm) + front (9 mm). 186 x 45 mm. Front: Plastic. Rear: Anodized aluminium. Weight: Approx. 600 g. 101

Parallel Interface UCT-31/31P UCT-31/31P DESCRIPTION REAR PANEL/CONNECTIONS General purpose message display for front panel mounting with up to 200 prestored messages. Each message contains 2 lines of text with up to 20 characters per line. Process values, counter values, etc. with up to 16 digits can be placed in the text field. The message display can easily be integrated into any PLC controlled system as the message selection and read-out of process values is controlled by 9 (or less) standard transistor outputs on the PLC. The UCT-31P version can be connected to a standard parallel printer and each message can be printed out for e.g. documentation together with the actual time and date derived from the built-in realtime clock. Versions available for direct mains supply or battery supply. 1 2 3 4 5 6 7 1. Parallel inputs, plug-in screw terminals. 2. Printer output, 25-pole sub-d. 3. Code switch. 4. Connector for external keyboard or PC. 5. Fuse. 6. Mains supply, plug-in screw terminals. 7. Ground terminal. VERSIONS/ORDERING CODES Type: UCT-31P 230 With 200 messages/16 variable digits. UCT-31 With 190 messages/16 variable digits/uct-31p printer output & real-time clock. 12-48V AC/DC 924 110-240V AC 230 102

Parallel Interface UCT-31/31P TECHNICAL DATA Display: Display field: Height of characters: Intensity: VFD type, 2 x 20 characters, 5 x 7 dot matrix. Readable at a distance up to 3 m. 125 x 22 mm. 5 mm. Programmable, 4 levels. Messages: Up to 200 messages (P-version: 190). 40 characters each. Messages are selected by an 8 bit binary code at the parallel input (100 messages using BCD selection). Messages are stored in built-in memory (EE- PROM) independent of supply voltage. Variable digits: Time/date digits: Character sets: Inputs: Up to 16 digits totally. The variable digits can be used for a single value or separated into a number of values and placed at any position in the text field. The values are entered by using a 4 bit binary code selecting the digit position and a 4 bit BCD code entering the digit value. Up to 10 digits totally. year-month-date, hours, minutes. The time/date digits can be placed at any position in the text field. Time/date are derived from the internal realtime clock. Danish, UK, German, Swedish. Danish CP850, UK CP850, Swedish CP850, German CP850 Swiss/1 CP850, French CP850 9 optocoupled inputs, PNP or NPN controllable. Programming: RS232C format: Mains frequency: Standard XT/AT-compatible keyboards or PC via RS232C. 1200 Baud, ASCII, 1 start bit, 8 bit, no parity, 1 stop bit. 7-pole female DIN connector (XT/AT compatible). 12-48V AC/DC (10.5-58V). 110-240V AC (90-265V). 40-60Hz. Consumption: Approx. 10W. Ambient temperature: -20 to +50 C. Protection: EMC: Isolation: Dimensions: Front: Depth: Panel cut-out: Housing: Front: Rear: Front: IP54. Rear: IP20. According to EN50081-1, EN50082-2. Mains: 4kV AC according to EN60950. Parallel input to electronics: 2kV AC 192 x 48 mm according to DIN43700. 96 mm + connectors (10 mm) + front (9 mm). 186 x 45 mm.: Plastic. Anodized aluminium. Weight: Approx. 600 g. ACC... UCT-32/34 UCT-35/35P UCT-31/31P UCT-30 UCT-33/36 INTRO... Input voltage: Input current: Input delay: 10-30V DC (active). Max. 3V DC (non active) 12V DC: Typically 3mA. 24V DC: Typically 6mA. Typically 1ms (noise suppression). MECHANICAL DIMENSIONS Built-in DC supply: 12V DC nom. max. 100mA Real-time clock: Time (hours-minutes) 2 x 2 digits. Calendar (year-month-date) 3 x 2 digits. Automatic correction for leap days. Correction for summertime via code switch. 48 192 9 96 10 Accuracy: 25 C: Better than ± 1s/day. -20 to +50 C: Better than ± 5s/day. Battery back-up: Min. 3 years, typically 5 years. Printer output: Standard parallel (Centronics type). For each message it is possible to select whether the message should be printed or not. Time and date will automatically precede all messages sent to the printer. 25-pole sub-d (female) connector. 103

Parallel Interface UCT-35/35P UCT-35/35P DESCRIPTION REAR PANEL/CONNECTIONS General purpose message display for front panel mounting with up to 200 prestored messages. Each message contains 2 lines of text with up to 20 characters per line. Process values, counter values, etc. with up to 16 digits can be placed in the text field. The message display can easily be integrated into any PLC controlled system as the message selection and read-out of process values is controlled by 9 (or less) standard transistor outputs on the PLC. 4 button keypad on the front with direct connection to the rear connector available for any command going to the inputs of the PLC. The UCT-35P version can be connected to a standard parallel printer and each message can be printed out for e.g. documentation together with the actual time and date derived from the built-in realtime clock. Versions available for direct mains supply or battery supply. 8 1 2 3 4 5 6 1. Parallel inputs, plug-in screw terminals. 2. Printer output, 25-pole sub-d. 3. Code switch. 4. Connector for external keyboard or PC. 5. Fuse. 6. Mains supply, plug-in screw terminals. 7. Ground terminal. 8. Keypad output, plug-in screw terminals. 7 VERSIONS/ORDERING CODES Type: UCT-35P 230 With 200 messages/ 16 variable digits/4 keys. UCT-35 With 190 messages/ 16 variable digits/4 keys/ printer output & real-time clock. UCT-35P 12-48V AC/DC 924 110-240V AC 230 104

Parallel Interface UCT-35/35P TECHNICAL DATA Display: Display field: Height of characters: Intensity: VFD type, 2 x 20 characters, 5 x 7 dot matrix. Readable at a distance up to 3 m. 125 x 22 mm. 5 mm. Programmable, 4 levels. Messages: Up to 200 messages (P-version: 190). 40 characters each. Messages are selected by an 8 bit binary code at the parallel input (100 messages using BCD selection). Messages are stored in built-in memory (EEPROM) independent of supply voltage. Variable digits: Time/date digits: Keypad: Load: Contact resistance: Character sets: Up to 16 digits totally.the variable digits can be used for a single value or separated into a number of values and placed at any posi tion in the text field. The values are entered by using a 4 bit binary code selecting the digit position and a 4 bit BCD code entering the digit value. Up to 10 digits totally. Year, month, date, hours, minutes. The time/date digits can be placed at any position in the text field. Time/date are derived from the internal realtime clock. 4 potential free push-buttons with common terminal. Tactile feedback type. Max. 30V/20mA. Max. 100Ohms. Danish, UK, German, Swedish. Danish CP850, UK CP850, Swedish CP850, German CP850 Swiss/1 CP850, French CP850 Mains frequency: 12-48V AC/DC (10.5-58V). 110-240V AC (90-265V). 40-60Hz. Consumption: Approx. 10W. Ambient temperature:-20 to +50 C. Protection: EMC: Isolation: Dimensions: Front: Depth: Panel cut-out: Housing: Front: IP54. Rear: IP20. According to EN50081-1, EN50082-2. Mains: 4kV AC according to EN60950. Parallel input to electronics: 2kV AC 192 x 48 mm according to DIN43700. 96 mm + connectors (10 mm) + front (9 mm). 186 x 45 mm. Front: Plastic. Rear: Anodized aluminium. Weight: Approx. 600 g. MECHANICAL DIMENSIONS 48 192 9 96 10 ACC... UCT-32/34 UCT-35/35P UCT-31/31P UCT-30 UCT-33/36 INTRO... Inputs: Input voltage: Input current: Input delay: Built-in DC supply: Real-time clock: Accuracy: Battery back-up: Printer output: Programming: RS232C format: 9 optocoupled inputs, PNP or NPN controllable. 10-30V DC (active). Max. 3V DC (non active). 12V DC: Typically 3mA. 24V DC: Typically 6mA. Typically 1ms (noise suppression). 12V DC nom. max. 100mA. Time (hours-minutes) 2 x 2 digits. Calendar (year-month-date) 3 x 2 digits. Automatic correction for leap days. Correction for summertime via code switch. 25 C: Better than ± 1s/day. -20 to +50 C: Better than ± 5s/day. Min. 3 years, typically 5 years. Standard parallel (Centronics type). For each message it is possible to select whether the message should be printed or not. Time and date will automatically precede all messages sent to the printer. 25-pole sub-d (female) connector. Standard XT/AT-compatible keyboards or PC via RS232C. 1200 Baud, ASCII, 1 start bit, 8 bit, no parity, 1 stop bit. 7-pole female DIN connector (XT/AT compatible). 105

RS232 Serial Interface UCT-32/32P/34/34P UCT-32 UCT-34 DESCRIPTION REAR PANEL/CONNECTIONS Message display/operator panel for front panel mounting with up to 190 prestored messages. Each message contains 2 lines of text with up to 20 characters per line. Process values, counter values, etc. with up to 16 digits can be placed in the text field. The message display utilizes a serial RS232 data interface to transfer data between the message display and a PLC. The message display has built-in drivers for different PLC types and the actual type is selected via a code switch on the message display. Optional versions with drivers/interface for Idec, ABB, Siemens and Koyo PLCs. Versions available with 4 or 24 button keypad. The UCT-32P/34P version can be connected to a standard parallel printer and each message can be printed out for e.g. documentation together with the actual time and date derived from the built-in realtime clock. The real-time clock data is also available for the connected PLC. Versions available for direct mains supply or battery supply. 1 2 3 4 5 6 7 1. PLC connector, 9-pole sub-d. 2. Printer output, 25-pole sub-d. 3. Code switch. 4. Connector for external keyboard or PC. 5. Fuse. 6. Mains supply, plug-in screw terminals. 7. Ground terminal. VERSIONS/ORDERING CODES Type: UCT-32 P 230 / I Number of keys: 4 UCT-32 24 UCT-34 Printer output: P 12-48V AC/DC 924 110-240V AC 230 Optional drivers: Idec FA2, FA2J, FA3. Idec Micro 3 ABB Procontic Siemens S5 Koyo DL205, DL405 I M3 ABB S K We are continuously developing new drivers. Please request our data sheet containing current information. 106

RS232 Serial Interface Operator Interfaces UCT-32/32P/34/34P TECHNICAL DATA Display: Display field: Height of characters: Intensity: Messages: Variable digits: Time/date digits: VFD type, 2 x 20 characters, 5 x 7 dot matrix. Readable at a distance up to 3 m. 125 x 22 mm. 5 mm. Programmable, 4 levels. Up to 190 messages, 40 characters each. Messages are selected via the serial data interface. Messages are stored in a built-in memory (EEPROM) independent of supply voltage. Up to 16 digits totally. The variable digits can be used for a single value or separated into a number of values and placed at any position in the text field. The values are entered via the serial data interface. Up to 10 digits totally, Year, month, date, hours, minutes. The time/date digits can be placed at any position in the text field. Time/date are derived from the internal realtime clock and are available for the connected PLC. Keypad: UCT-32: 4 keys. UCT-34: 24 keys. Tactile feedback type. Acoustic feedback selectable. Character sets: Serial input: Option I version: Option S version: PLC drivers: Option I: Danish, UK, German, Swedish. Danish CP850, UK CP850, Swedish CP850, German CP850 Swiss/1 CP850, French CP850 RS232C. Option M3: Idec Micro 3 Non standard interface adapted to the programming port of the PLC. 20mA current loop (TTY). 9-pole male sub-d connector. Idec FA2, FA2 (CPU-5M), FA2J, FA3 (CP11/12/13). Battery back-up: Printer output: Programming: RS232C format: Mains frequency: Min. 3 years, typically 5 years. Standard parallel (Centronics type). For each message it is possible to select whether the message should be printed or not. Time and date will automatically pre cede all messages sent to the printer. 25-pole sub-d (female) connector. Standard XT/AT-compatible keyboards or PC via RS232C. 1200 Baud, ASCII, 1 start bit, 8 bit, no parity, 1 stop bit. 7-pole female DIN connector (XT/AT compatible). 12-48V AC/DC (10.5-58V). 110-240V AC (90-265V). 40-60Hz. Consumption: Approx. 10W. Ambient temperature: -20 to +50 C. Protection: EMC: Isolation: Dimensions: Front: UCT-32: UCT-34: Depth: Panel cut-out: Housing: Front: IP54. Rear: IP20. According to EN50081-1, EN50082-2. Mains: 4kV AC according to EN60950. 192 x 48 mm according to DIN43700. 192 x 96 mm according to DIN43700. 96 mm + connectors (10 mm) + front (9 mm). 186 x 45 mm. Front: Plastic. Rear: Anodized aluminium. Weight: Approx. 600 g. MECHANICAL DIMENSIONS ACC... UCT-32/34 UCT-35/35P UCT-31/31P UCT-30 UCT-33/36 INTRO... Option A: Option S: Option K: Real-time clock: Accuracy: ABB Procontic, CPU type: 07KR31, 07KR91, 07KT92, 07KP62 & 35ZE94 (active mode). L1 network: Siemens S5PLC, CPU type: S5/95U, S5/100U, S5 115U/ CPU941 & CPU/942. K-sequence: Koyo DL205, DL405, CPU type: DL230, DL240, DL430, DL440. Time (hours-minutes) 2 x 2 digits. Calendar (year-month-date) 3 x 2 digits. Automatic correction for leap days. Correction for summertime via code switch. 25 C: Better than ± 1s/day. -20 to +50 C: Better than ± 5s/day. UCT-34: 96 UCT-32: 48 192 9 96 10 107

Accessories PC EDITOR UCTTOOL32 The PC editor UCTTOOL32 provides all facilities for easy programming, editing, storage and transfer of message files. Message files are transferred between the PC and message display via a RS232 link. EXTERNAL KEYBOARD UCK-21 CABLES FOR PC PROGRAMMING Cable, 25-pole sub-d. Cable, 9-pole sub-d. UCC-201 UCC-202 UCC-201: 2.5 m FRONT PLATE ADAPTER The front plate adapter makes it simple to replace older UCT-20/21 message displays with new UCT-30/31/31P displays. No extra holes are required to fit the adapter plate which is placed between the front plate of the message display and the panel front. UCC-202: 2.5 m CABLES FOR PLC COMMUNICATION Cable for ABB Procontic (2.5 m) UCC-216 Cable for Siemens S5 (2.5 m) UCC-217 Cable for Idec FA2, FA2J, FA3 (2.5 m). UCC-218 Cable for Idec Micro 3 (2,5m) UCC-219 BRODERSEN ENTER NEW SETPOINT ACTUAL: 200 NEW 280 AMF-20 Front plate adapter. Rubber washed for increased front sealing IP 66: IP-66. AMF-32 UCT-30/31/32/33/35 AMF-34 UCT-34/36 CABLES AVAILABLE FROM KOYO DISTRIBUTOR Cable for Koyo DL205. D2-DSDBL Cable for Koyo DL405. D4-DSCBL CABLE FOR PC COMMUNICATION UCC-561 UCC-561: 3.0 m 108