installation quick guide integrated access control & environmental monitoring

Similar documents
AX200. Installation Guide

AX200 & i-box. Installation & User Guide

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro 1500 Single Door IP Controller

emerge Essential Access Control System

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

PRT-RDS2 Standard 2 Reader Expander

Single Door Standalone Access Control User Manual

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

W3-H Waterproof Keypad/Reader/Controller

SNAP, CLICK, DONE. Getting Started Guide

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010

Saturday from 09:00-13:00 (GMT) Documentation on all Paxton products can be found on our website -

Digital Keypad Introduction

Quick Start Installation Guide

A list of distributors can be found on our website at -

6222 Two Door Module Technical Operations Manual

Installing Keypad and Backplate

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

7612 Programming Instructions

IBA-7612 Programming Instructions

Startup Guide. NetAXS-123. Version 5.2

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

TOUCHLOCK compact keypad Stainless Steel

W3-M. Metal waterproof standalone access control/reader. User Manual

Technical Manual Nova: Cabinet Security Management System (CSMS)

Waterproof. Keypad/Reader/Controller

User Manual. PCKeypad Wireless Keypad

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

A

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

PRT-RDE2 Ethernet 2 Reader Expander

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

ACTsmart2 Product Range Operating and Installation Instructions

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Innovative Electronics for a Changing World INDEX

User Manual SOLOgarde

Installation Instructions

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

SNMP Web Management. User s Manual

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Model HM-535 Power Supply Installation and Service Instructions

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

CM-110SK Standalone Keypad Installation Instructions

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

TALS 2. Torque Activated Logging System. Operating Instructions

PRT-PX16 16 PGM Output Expander

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

SCP Hardware Quick Reference

VIDI-AC-2CS Access Controller/ Reader

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

EL-ST100 KEYPAD CONTROLLER

AX Enterprise

Dimensioned drawing. Measurement principle

SEM3 - Embedded Micro Metering Module

DOLXFD1000B. Waterproof Access Control/Reader

EnCell Battery Cell Monitor

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Access Control System - Installation Guide

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

GV-AS200 Controller. Hardware Installation Guide

Sigma XT Ancillary Board (K588)

TOUCHLOCK compact. Ins-182 Date code:

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE

smartentry Wireless Video Doorphone User Manual

Technical Instructions MT15000/2 MT15000/2-M

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

Quick Start Guide. Mounting the Essential Plus and Elite

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

REX F-0-9 Standalone or Access Controller

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Installation and User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

SensorWATCH Basic RH - Wireless Setup Users Help Guide Part Number: A Revision: 1.1.0

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

CF3000 Dealer Diagnostic Tool Instruction Manual

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Installation & User Manual

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Canlan INSTALLATION MANUAL

Operation manual For NG BIOSINGLE Version 1.1

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

AX3000 Platine Terminal Ethernet TCP/IP

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Transcription:

installation quick guide integrated access control & environmental monitoring

Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical connection diagrams are shown at the back of this document. Technical Specifications and urrent onsumption output (x 2): 2 volts D.5 Amps maximum each lock output 3 Amps total Auxiliary output: 2 volts D at Amp maximum Sensor ports: 500mA Readers & peripherals: 500mA Mains Supply Rating: 5 Amps urrent onsumption: 4W Mains Input Voltage: 00 to 240 volts A 50/60 Hz. Replacement glass fuses on the mains fused input block are 3.5 Amps slowblow Based on typical example on the AX300 controller with 2 standard magnet locks and two proximity readers BTU = 82.49 It is advised to leave 20mm spacing between adjacent controllers at the vents Watts = 52.4 at 237VA @ 0.22Aac Dimensions: Nett Weight: Monitoring 300 x 260 x 75mm (.8 x 0.25 x 3.5 ) actual 305 x 260 x 80mm (2.00 x 0.25 x 3.5 ) with space for vents 2.5kg (5.5lb) controller 2.3kg (5.07lb) optional battery The AX300 has an integrated power and battery monitoring circuit if mains power is lost, it is indicated on the controller unit and the server software. If installed, the 7 Ampere battery will automatically initiate without any power interruption. The battery low alarm indicates prior to the battery being automatically cutoff to prevent battery drainage damage. In addition, on a daily basis, the power circuit and battery are tested and the transactions stored in the server software for diagnostic purposes. If during installation no mains power is available, the controller unit can be installed, tested and commissioned by activating the battery start button on the controller. If this method of test is used, the battery must be disconnected and reconnected to reset the unit ready for standard mains operation. able Specifications Description able Type Maximum Length AX300 Ethernet onnection 0mbs at 5/at 5E 00 metres (328ft) AX300 to AX Reader 6 ore >22 Awg 50 metres (64ft) AX300 to / ontact 2 ore 24 Awg 50 metres (64ft) AX300 to 2 ore > 22 Awg 50 metres (64ft) Sensors 4 core 26 Awg 5 metres (49ft)

onfiguring the AX300 IP Address using the Navigation Keys Note The IP address can only be configured using the keypad whilst the AX300 controller is offline. The general display will scroll between system offline and the AX300 name which is blank by default. Press the display will show Sensor present 2. Press the display will show Reset all 3. Press the display will show Network settings 4. Press to enter the network settings menu 5. The first option is the local IP address, and is by default 0.0.0.0 the local IP address is the address for the AX300 controller. 6. Press OK to change the IP address. Use and to scroll between the range off 0255, when the number on the display is correct press to move to the next part of the address. When the full IP address is on the screen press OK to return to the menu. 7. Press to move to Gateway IP, repeat step 6 to enter a valid Gateway IP address, if this is not required then leave the gateway address at 0.0.0.0 8. Press to move to Subnet mask, the default subnet mask is 255.255.255.0 if this needs to be changed repeat step 6 9. Press to move to Host IP address, this needs to be set to the IP address of the P running the AX software. 0. Press to exit the Network Settings menu. Press to return to the main menu 2. Plug the AX300 controller into the network and add the controller into the software. LD Menu Structure >System Online> >300> >Other System Messages> >Sensors Present 23456> >System Online> > OK> > Status> > OK > > OK 2> > OK Readers> > OK Sensors 3> > OK Sensors 46> >Network Settings> * >Local IP 0.0.0.0> >Host IP 0.0.0.0> >Subnet Mast 255.255.255.0> >Gateway IP 0.0.0.0> >Reset All> ** >onfirm Reset> >ancel Reset> * Network address settings can only be set / amended whilst the unit is offline ** Only displayed when the unit is offline

AX300 ontroller Front Panel Indication Identifier Description olour Indicates able Link Green ON = Ethernet link OFF = Ethernet link incorrect or missing connection (check network cable) Network Activity Amber Flashing network data / activity 2V Output OK Green ON = onboard power supply OK ~ A Input Green ON = mains power supply OK + Fault Red ON = low battery indicator Point Point 2 Green/Red Green/ Red Green Flashing = normal mode Green ON= door unlocked Red Flashing = high security mode Red ON = deadlock mode Alarm Red ON = warning alarm, read LD display for detailed information. To clear alarm press OK Left standard wallmounted AX300 controller shown with optional battery backup

AX300 Software Setup. Install the standard AX200. The software is provided on the D supplied with the controller, alternatively, this can be downloaded from the website http://www.axxessidsoftware.co.uk. To install the software click on the file setup.exe and follow the on screen prompts. 2. Ensure that the P is connected to the network and has a static IP address 3. Start the software. Enter the user name and password: Default user name: Default password: Then click OK. Allow the software to initialise. 4. On the transaction screen check for any error messages and address these before proceeding eg. duplicate IP address refer to the Technical Manual for additional details. 5. The AX300 controller can be powered up and connected to the network. Installing a New Device There are two methods of installing new devices setup using the Device Wizard, or Manual onfiguration to configure the new device manually proceed to step 3. Using the Device Wizard The Device Wizard icon appears when an AX300 controller is connected on the same LAN network and has not been configured. Device Wizard Icon 6. Select the Device Wizard Icon. 7. Ensure the New Device Wizard set to automatic (default) then select Add. In the dialog box that appears Set block of IP address select OK. Note after this has been initially completed, this step will no longer appear.

8. onfigure the Server by selecting the Server IP button or by manually entering the IP address provided by your IT Department. 9. onfigure the start address by selecting the start address button or entering the IP address manually provided by your IT Department, then select OK. Server IP Button Start Address Button 0. In the Device Manager window ensure the set device remains on the default setting (automatic) and select Add.. Enter the name of your first access point access point reader (eg. Main ). Select the mode of use. (eg ard only), then select Next. 2. Repeat step for the second access point access point reader 2, then select OK. When the controller has been successfully added proceed to step 22. Manual onfiguration of an AX300 If you have configured the AX300 using the Device Wizard proceed to step 22. 3. From the Main Screen select the Point button at the bottom of the 4. Select the Device Manager tab. 5. Wait approximately 0 seconds, whilst the Device Manager searches the network for AX300 controllers powered on. It is recommended to configure one controller at a time. P Server Icon AX300 controllers not configured are displayed in red, whilst AX300 controllers configured are displayed in grey. Previously configured AX300 controllers that are not online are displayed in grey with a red cross through.

6. Double click on the P Server icon, located at the top of the image tree. 7. Select the Server IP button to toggle between server address (if more than one is available). 8. In the Auto set up for device box. Select the Start address button to obtain the next available IP address or manually enter the IP range provided by your IT department, then select OK. Server IP Button The P Server icon will now be displayed in blue indicating that it has been configured. Start Address Button 9. Double click on the AX300 device, displayed in red. AX300 Device 20. Type in a name for the AX300 controller. Select the Auto Set button to automatically add the IP address or alternatively manually enter the IP address, then select Download. Select Yes in the "Are you sure?" dialog box. 2. After approximately 5 seconds the New Device Wizard will be displayed, select Add. Type in the name of the Point into the text box and select type of access required. (eg. ard only), then select Next Repeat step 2 for the second Point. The TP/IP setting screen can now be closed.

Online Status 22. The Main Screen displays the AX300 controller and peripheral status data, including the two access point names. Status AX300 Setup for Single Point (In/Out Readers) To setup the AX300 controller for a single door with In and Out readers follow these settings: 23. Select the Point shown at the bottom of the screen. Select the Device Manager tab. 24. Double click on the device that you want to configure. Single In / Out 25. Ensure the Single door In Out option is checked. lose the TPIP Settings window. 26. Set the first access point to either In Reader or Out Reader. Select Save. Select the second access point and set it to the opposite of the first access point In Reader or Out Reader. Select Save and then lose. In Reader Out Reader Points Save

Add a ard or Keyfob for Testing 27. From the Main Screen select ardholder button. Then select the blue Add button. Enter the ard number, together with cardholders details. Fields highlighted in Yellow are mandatory, these include ard Number, Group and Time Zone. Select Save. These details will now appear in the table at the bottom of the screen. Select lose. This will download the cardholder data. Add 28. The AX300 controller is now ready for testing. Save Adding Sensors on the AX300 ontroller The AX300 has six sensor ports, with a wide range of sensors available including temperature, humidity, flood, current, vibration, smoke, dust, and additional inputs /outputs.. Plug the sensor to one of the 6 sensor ports on the AX300 controller. 2. From the software, the Add Device Wizard will start automatically, select Add. 3. Specify default settings and select next. 4. Enter an appropriate name for the sensor and select OK. 5. The sensor will be added to the system. 6. To review and edit the settings go to the environment screen and select the sensor from the controller tree view. Read frequency The interval in seconds for the sensor to read its value Reporting frequency The interval in seconds for the sensor to report the reading Status / Time Normal Max PreAlarm Min hange / Value last reading from the sensor Enter the normal or average reading for future reference High limit value for sensor to generate an alarm Prealarm limit value for the sensor Low limit value for sensor to generate an alarm Select change and enter a value. If the reading changes and exceeds the value entered between the reporting interval, an alarm will occur. For example on a temperature sensor if the temperature increases by 2 degrees in 60 seconds an alarm will occur.

AX300 Fail Safe onnections Granted Point & 2 Pulse second Point Point 2 Relay 4 Relay 5 Factory Reset Hold down for 0 seconds during startup 2v 7aH AX Reader Point Tamper Strobe Sounder S e n s o r P o r t s RJ45 Ethernet Relay Outputs voltfree contacts max. 5A at 2VD ircuit Restart External Alarm Output 2 3 4 5 6 D Data N NO N 2 2 NO 2 N 3 3 NO 3 4 NO/N 5 NO/N ontact / 2VD.5A max. Point Reader (In) D Data 5VD In I/O Expander + 2 volt out max. A In + AX300 IP ontrol & Environmental Monitoring Inputs ontact / 2VD.5A max. Point 2 Point 2 Reader (Out) Fail unlocked magnet lock and fail safe electric strikes 2VD.5 ampere maximum Fail locked fail secure electric strike 2VD.5 ampere maximum AX300_V2_0 3 ntct ntct External alarm output max. 50mA 2VD Relay 4 and 5 program in software normally open (NO) or normally closed (N) Input 4 Input 5 Fire + 2V www.axxessid.com ontact L Exit Switch ontact Triple Pole 5 2 5 2 6 4 3 Triple Pole 6 4 3 + + Exit Switch L AX Reader

AX300 Fail Secure onnections Granted Point & 2 Pulse second Point Point 2 Relay 4 Relay 5 Factory Reset Hold down for 0 seconds during startup Point 2v 7aH 6 + AX Reader 7 AX Reader Tamper S e n s o r P o r t s 5VD In I/O Expander RJ45 Ethernet N NO N 2 2 NO 2 N 3 3 NO 3 4 NO/N 5 NO/N Strobe Sounder + 2 volt out max. A Relay Outputs voltfree contacts max. 5A at 2VD External Alarm Output External alarm output max. 50mA 2VD Relay 4 and 5 program in software normally open (NO) or normally closed (N) ircuit In + Point 2 AX300 IP ontrol & Environmental Monitoring ontact / 2VD.5A max. Point Reader (In) Inputs ontact / 2VD.5A max. Point 2 Reader (Out) Restart Fail unlocked magnet lock and fail safe electric strikes 2VD.5 ampere maximum Fail locked fail secure electric strike 2VD.5 ampere maximum AX300_V2_0 3 2 3 4 5 6 D Data D Data ntct ntct Input 4 Input 5 Fire + 2V www.axxessid.com ontact Triple Pole 3 L Exit Switch Optional Optional ontact Triple Pole 3 Exit Switch L 6 + 7

AX300 In and Out Reader onnection Factory Reset Hold down for 0 seconds during startup 2v 7aH Granted Point & 2 Pulse second Point Point 2 Point Tamper Relay 4 Relay 5 Strobe Sounder S e n s o r P o r t s RJ45 Ethernet Relay Outputs voltfree contacts max. 5A at 2VD Restart ircuit External Alarm Output 2 3 4 5 6 D Data N NO N 2 2 NO 2 N 3 3 NO 3 4 NO/N 5 NO/N D Data 5VD In I/O Expander AX300 IP ontrol & Environmental Monitoring ontact / 2VD.5A max. Point Reader (In) In ontact / + 2VD.5A max. Point 2 Point 2 Reader (Out) Fail unlocked magnet lock and fail safe electric strikes 2VD.5 ampere maximum Fail locked fail secure electric strike 2VD.5 ampere maximum AX300_V2_0 3 ntct Inputs ntct External alarm output max. 50mA 2VD Relay 4 and 5 program in software normally open (NO) or normally closed (N) Input 4 Input 5 Fire + 2V www.axxessid.com + 2 volt out max. A ontact Button Masked out on computer it will not display on the screen on Point but can be connected Triple Pole 5 2 6 4 3 +

AX300 Barrier / Automatic ontrol In and Out onnection Factory Reset Hold down for 0 seconds during startup Exit Loop Voltage Free NO onnection Optional AX Reader Tamper S e n s o r P o r t s 2v 7aH Restart RJ45 Ethernet Relay Outputs voltfree contacts max. 5A at 2VD Granted Point & 2 Pulse second Point Point 2 Relay 4 Relay 5 External Alarm Output ircuit Point 2 3 4 5 6 D Data D Data N NO N 2 2 NO 2 N 3 3 NO 3 4 NO/N 5 NO/N Strobe Sounder 5VD In I/O Expander AX300 IP ontrol & Environmental Monitoring ontact / 2VD.5A max. Point Reader (In) In + Point 2 ontact / 2VD.5A max. Point 2 Reader (Out) Fail unlocked magnet lock and fail safe electric strikes 2VD.5 ampere maximum Fail locked fail secure electric strike 2VD.5 ampere maximum AX300_V2_0 3 ntct External alarm output max. 50mA 2VD Relay 4 and 5 program in software normally open (NO) or normally closed (N) Inputs ntct Input 4 Input 5 Fire + 2V www.axxessid.com Barrier/Automatic door Monitoring. Voltage Free N onnection Optional + 2 volt out max. A Barrier/Automatic door Monitoring. Voltage Free N onnection Optional + Third Party Relay Barrier ontroller or onnection AX Reader Third Party Relay Exit Loop Voltage Free NO onnection Barrier ontroller or onnection Optional +

AX300 Barrier ontrol / Automatic

AX300 Third Party HID Readers Fail Safe onnection Granted Point & 2 Pulse second Point Point 2 Relay 4 Relay 5 Factory Reset Hold down for 0 seconds during startup 2v 7aH Tamper Point S e n s o r P o r t s Strobe Sounder RJ45 Ethernet Relay Outputs voltfree contacts max. 5A at 2VD ircuit Restart External Alarm Output 2 3 4 5 6 D Data N NO N 2 2 NO 2 N 3 3 NO 3 4 NO/N 5 NO/N ontact / 2VD.5A max. Point Reader (In) D Data 5VD In I/O Expander + 2 volt out max. A In + AX300 IP ontrol & Environmental Monitoring Inputs ontact / 2VD.5A max. Point 2 Point 2 Reader (Out) Fail unlocked magnet lock and fail safe electric strikes 2VD.5 ampere maximum Fail locked fail secure electric strike 2VD.5 ampere maximum AX300_V2_0 3 ntct ntct External alarm output max. 50mA 2VD Relay 4 and 5 program in software normally open (NO) or normally closed (N) Input 4 Input 5 Fire + 2V www.axxessid.com ontact L Exit Switch control wire is orange ontact Triple Pole 5 2 5 2 6 4 3 Triple Pole 6 4 3 + + Exit Switch L control wire is orange

November 203 2_5 Installation Instructions The AX300 controller includes a fixing kit for installation onto brick or plasterboard walls. Please note the controller is not suitable for outdoor use and should be installed in an area protected from the elements of rain/ water.. Drill top centre hole using a 6mm drill bit. Insert rawl plug and insert screw, do not over tighten the screw in the plug until all the holes have been drilled. 2. Hang the unit on the screw, ensure the unit is hanging inline horizontally, mark the two bottom fixing holes with a marker pen. 3. Remove the unit from the screw. Drill the two additional mounting holes, inserting a rawl plug in each. 4. Hang the unit back on the top centre screw and hand tighten. Insert and hand tighten the two bottom fixing screws. 5. Before finishing, ensure the unit is straight, then tighten all three screws. AX300 Drilling Dimensions 20.00 260.00 27.00 30.00 50.00 300.00 305.00 270.00 Distributor: 2728 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN6 8TZ United Kingdom Tel: +44 (0)793 784002 Fax: +44 (0)793 784005 Email: info@axxessid.com Website: www.axxessid.com