EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

Similar documents
sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

EE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

HLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

CDD4 Duct Carbon Dioxide Transmitter

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

EE671 - Miniature Air Flow Transmitter

EE870 Modular CO 2 Transmitter

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Environmental Conditions C - remote sensing probe up to 120 C (248 F)

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

EE160 - Humidity and Temperature Transmitter for HVAC Applications

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

TOXALERT MODEL AIR 2000

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

Immersion Temperature Sensors

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

TEMPERATURE CO 2 CALIBRATION

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

Multi-range pressure and differential pressure transmitter

GMM220 CO 2. Transmitter Modules. Introduction. Mounting

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

CDD4 Series Room CO2 Transmitter Installation Instructions

Manual EE371. Dew Point Transmitter / Switch down to -60 C Td. BA_EE371_e // V2.0 // technical data are subject to change

WIRELESS TRANSMITTER DUOS CO 2

Room unit with PPS2 interface

HygroFlex HF3 Transmitters. User Guide

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

CDD Carbon Dioxide Transmitter

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

EE210. Humidity and Temperature Transmitter for Demanding Climate Control Applications. Features. Applications

InBin-P Pressure switches from 5 Pa Pa

CAEL-DP Series Dew Point Transmitter for Industrial Control

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

RТTH DUAL ROOM SWITCH

InCos-P Pressure sensor 20 Pa Pa

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION

Flush-mount room sensor

DP DP2500 DP0250

Precision digital measuring device PHYSICS 51

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

AIR QUALITY/ GAS DETECTION

Ease of Use. Data at Your Fingertips LMS PHARMA

Humidity goes Digital

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Sensor for car parks and tunnels

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

PHYSICS Digital Measuring Devices

HT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control

Evo2. Free programmable room controller. Summary

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

User Manual. PolyGard AT Infrared Carbon Dioxide transmitter Serial No. AT December, PolyGard is a registered trademark of MSR

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

C7110C1001A / C7110D1009A WALL MODULES

Room unit with PPS2 interface

TXM1.8RB. TX-I/O Blinds module

Room Temperature Controllers

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

EE210. Humidity and Temperature Transmitter for Demanding Climate Control Applications. Features. Applications

MOD-RI Room Interface Modules with Modbus

HygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL

PTU300 Combined Pressure, Humidity and Temperature Transmitter

TPM 80. Dew Point Transmitter. Manual. BA_TPM80_e // V1.0 // technical data are subject to change

Precision humidity/temperature control/sensing

HygroFlex HF7 Humidity Temperature Transmitters. User Guide

Resistance measuring module

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Room Temperature Controller

Table of contents: 1. HygroClip 2 in general. 2. The different probes. 3. Features in details. 4. Customer benefits. 5. Replacement overview

Product Specification. CO 2 Engine ICB. Sensor module for bio applications

RXTH DUAL ROOM SENSOR / SWITCH

Transcription:

EE80 Series HVAC Room Transmitter and Switches for, Relative Humidity and Temperature EE80 series set new standards in measurements for HVAC. The transmitters resp. switches combine, relative humidity (RH) and temperature (T) measurement in one modern and userfriendly housing. The basic EE80 version for and T can be easily extended with a RH plug-in module. The measerument is based on the infrared principle. A patented auto-calibration procedure compensates for the aging of the infrared source and ensures outstanding long term stability. EE80 provides analogue outputs (in V or ma). The optional display indicates sequentially the actual measuring data. As one more option a switching output with adjustable switching point and hysteresis is available. A wide variety of models ensures an optimal adjustment for customised requirements. EE80 Typical Applications building management for residential and office areas ventilation control Technical Data Measuring values Measurement principle Non-Dispersive Infrared Technology (NDIR) Sensor E+E Dual Source Infrared System Working range 0...2000ppm 0...5000ppm Accuracy at 20 C (68 F) 0...2000ppm: < ± (50ppm +2% of measuring value) and 1013mbar 0...5000ppm: < ± (50ppm +3% of measuring value) Response time t 63 < 90 sec Temperature dependence typ. 2ppm / C Long term stability typ. 20ppm / year Sample rate ca. 0.5 min Relative Humidity Measurement principle capacitive Sensor element HC103 Working range 1) 10...90% RH Accuracy at 20 C (68 F) ±3% RH (30...70% RH) ±5% (10...90% RH) Temperature Accuracy at 20 C (68 F) ±0.3 C (±0.54 F) version with current output 4-20mA: ±0.7 C (±1.26 F) Outputs 0...2000/5000 ppm / 0...100% RH / 0-5V -1mA < I L < 1mA 0...50 C (32...122 F) 0-10V -1mA < I L < 1mA 4-20mA R L < 500 Ohm Max. switching voltage 50V AC / 60V DC Max. switching load 1A at 50V AC 1A at 30V DC Min. switching load 1mA at 5V DC Contact material Ag+Au clad General Supply voltage SELV 24V AC ±20% 15-35V DC SELV = Safety Extra Low Voltage Power requirement < 3 W Warm up time 2) < 5 min EE80 96 Features / RH / T measurement in one device RH output with plug-in module analogue or switching output modern design optional display easiest installation long term stability v1.7

Display LC display: alternating (ppm) / T ( C or F) / RH (% RH) Electrical connection screw terminals max. 1.5 mm 2 (AWG16) Electromagnetic compatibility EN 61000-6-3 EN61326-1+A1+A2:05.2002 EN 61000-6-1 Working temperature range 0...90% RH (non condensing) / -5...55 C (23...131 F) Storage temperature range 0...90% RH (non condensing) / -20...60 C (-4...140 F) 1) refer to the working range of the humidity sensor HC103! 2) warm up time for performance according specification Connection Diagram am EE80-xx2/3x EE80-xCS power supply 15...35V DC 24V AC ±20% power supply 15...35V DC 24V AC ±20% EE80-xx6x relay status switching off Hysteresis [% of MR] power supply 15...35V DC 24V AC ±20% ON 25% of MR OFF Level [% of MR] switching on Housing Dimensions (mm) 500 1000 2000 ppm Material of housing: Protection class: PC IP20 Colour of housing: Cover: Back: RAL 9003 (signal white) RAL 7035 (light grey) (other colours upon request) W x H x D = 85 x 100 x 26mm (3.3 x 3.9 x 1 ) Ordering Guide EE80 voltage / current output: WORKING RANGE MODEL DISPLAY T-UNIT T-SCALE + T (CT) + T + RH (CTF) 0-5V (2) 0-10V (3) 4-20mA 1) (6) without display (--) with display (D04) C (--) F (E01) 0...50 (T04) -5...55 (T31) 0...40 (T55) other (Txx) EE80- EE80-1) current output (6) not available for model CTF EE80 switching output: WORKING RANGE Accessories MODEL (C) switching output - humidity plug-in module (HA011003) (S) 97 Order Example EE80-2CT3D04-T04 Version with voltage output: Working range: 0...2000ppm Model: + T Output: 0-10V Display: with display T-Unit: C T-Scale: 0...50 C (32...122 F) EE80

EE85 Series Duct mounted transmitters and switches of the EE85 series are designed for HVAC applications. The sensing element uses the Non-Dispersive Infrared Technology (NDIR). A patented auto-calibration procedure compensates for drift caused by the aging of the sensing element and guarantees outstanding long term stability. Installed into a duct a small flow of air will be established by convection through the probe into the transmitter housing and back into the duct. Inside the transmitter housing the air will diffuse through a membrane into the sensing element. The operation in closed loop air stream avoids pollution of the sensor. EE85 Measuring ranges of 0...2000ppm and 0...5000ppm correspond to an analogue interface of 0-5/10V or 4-20mA. Selectively a switching output with adjustable switching point and hysteresis is available. The instruments can be easily positioned in the duct with the standard mounting flange. Typical Applications building management for residental and office areas ventilation control Technical Data Measuring Values Measurement principle Sensing element Non-Dispersive Infrared Technology (NDIR) E+E Dual Source Infrared System Measuring range 0...2000ppm / 0...5000ppm Accuracy at 20 C (68 F) 0...2000ppm: < ± (50ppm +2% of measuring value) and 1013mbar 0...5000ppm: < ± (50ppm +3% of measuring value) Traceable to international standards, administrated by NIST, PTB, BEV... 1) Response time τ 63 < 120s Temperature dependence typ. 2ppm / C Long term stability typ. 20ppm / year Sample rate ca. 30s Outputs s 0...2000ppm / 0...5000ppm 0-5V -1mA < I L < 1mA 0-10V 4-20mA -1mA < I L < 1mA R L < 500 Ohm Max. switching voltage 50V AC / 60V DC Max. switching load 1A at 50V AC 1A at 24V DC Min. switching load 1mA at 5V DC Contact material Ag+Au clad General Supply voltage SELV 24V AC ±20% 15-35V DC SELV = Safety Extra Low Voltage Power requirement < 3W Warm up time 2) < 5 min Housing / protection class PC / housing: IP65, probe: IP20 Cable gland M16 x 1.5 cable Ø 4.5-10 mm (0.18-0.39 ) Electrical connection screw terminals max. 1.5 mm 2 (AWG 16) Electromagnetic compatibility EN 61000-6-3 ÖVE EN61326-1+A1+A2:05.2002 EN 61000-6-1 FCC Part 15 ICES-003 ClassB Working temperature and conditions -5...55 C (23...131 F) 0...95% RH (not condensating) Storage temperature and conditions -20...60 C (-4...140 F) 0...95% RH (not condensating) 1) minimum flow speed 1m/s (200ft/min) 2) warm up time for performance according to specification EE85 102 Transmitter and Switches for Duct Mounting Features very simple installation compact housing auto-calibration traceable calibration measuring ranges: 0...2000ppm or 0...5000ppm analogue or switching output v1.3

Dimensions (mm) Operation Principle 12 (0.47 ) Seal 37.2 (1.46 ) sensing element A 80 (3.15 ) A...according to ordering guide 80 (3.15 ) air flow direction Connection Diagram am s EE85-xC2/3x EE85-xCSx EE85-xC6x relay status switching off Hysteresis [% of MR] ON 25% of MR ma OFF Level [% of MR] switching on 500 1000 2000 ppm Ordering Guide Order Example MEASURING RANGE EE85- MODEL PROBE LENGTH (see dimensions A ) (C) 0-5V (2) 50mm (2) 0-10V (3) 200mm (5) 4-20mA (6) switching output (S) EE85-5C35 measuring range: 0...5000ppm model: output: 0-10V probe length: 200mm 103 EE85

EE82 Series Measuring instruments in green houses or life stock barns are exposed to a very demanding environment: high humidity levels, pollutants like fertilizers, herbicides and high ammonia concentrations are just a few of the many hazards. The robust, functional housing of the EE82 with integrated special filter has been designed for such applications. The air diffuses through the filter into the instrument enclosure. Then the air diffuses further through a second membrane filter integrated in the measuring cell. The measurement is based on the non-dispersive infrared (NDIR) technology. The patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field. Measuring ranges of 0...2000/5000/7000ppm correspond to an analogue interface of 0-5/10V or 4-20mA. Selectively a switching output with adjustable switching point and hysteresis is available. The very practical snap-in mounting flange and connector for the supply voltage and outputs allow quick and easy installation of the EE82 without ever opening the housing. Typical Applications green houses fruit and vegetable storage life stock barns Technical Data Measuring Values Measuring principle Non-Dispersive Infrared Technology (NDIR) Sensing element E+E Dual Source Infrared System Measuring range 0...2000/5000/7000ppm Accuracy at 20 C (68 F) 0...2000ppm < ± (50ppm +2% of measuring value) and 1013mbar 0...5000ppm < ± (50ppm +3% of measuring value) 1) Response time τ 63 0...7000ppm < ± (50ppm +5% of measuring value) < 120s Temperature dependence typ. 2ppm / C Long term stability typ. 20ppm / year Sample rate ca. 30s Output 0...2000/5000/7000ppm 0-5 / 0-10V -1mA < I L < 1mA 4-20mA R L < 500 Ohm Max. switching voltage 50V AC / 60V DC Max. switching load 1A at 50V AC 1A at 30V DC Min. switching load 1mA at 5V DC Contact material Ag+Au clad General Supply voltage SELV 24V AC ±20% 15-35V DC SELV = Safety Extra Low Voltage Power requirement < 3W Warm up time < 5 min Housing / protection class PC / IP54 Electrical connection M12 plug Electromagnetic compatibility EN 61000-6-3 ÖVE EN61326-1+A1+A2:05.2002 EN 61000-6-1 FCC Part 15 ICES-003 ClassB Working temperature and conditions -20...60 C (-4...140 F) 0...100% RH Storage temperature and conditions -20...60 C (-4...140 F) 0...95% RH (not condensating) 1) minimum air velocity 1m/s (200ft/min) EE82 98 Transmitters and Switches for Agriculture Applications EE82 Features easy installation compact housing auto-calibration measuring range 0...2000/5000/7000ppm analogue or switching output v1.3

80 (3.15 ) Dimensions (mm) 80 (3.15 ) 51 (2 ) snap in - mounting kit Connection Diagram am EE82-xC2/3/6 EE82-xCS 1) GND internally conected relay status switching off Hysteresis [% of MR] ON 25% of MR OFF Level [% of MR] switching on 500 1000 2000 ppm Ordering Guide Order Example MEASURING RANGE 0...7000ppm (7) MODEL (C) 0-5V (2) 0-10V (3) 4-20mA (6) switching output (S) EE82-5C3 Measuring range: 0...5000ppm Model: Output: 0-10V EE82- EE82 99