Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL

Similar documents
Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control INDUSTRY LEADING FEATURES / BENEFITS

Product Data. SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR TOUCH CONTROL

Installation, Start-up and Operating Instructions

Commercial Controls. Advanced control for saving time and money

SE7600E Series Application Guide

Connect with Comfort. Phone not included. Smart Wi-Fi Universal Thermostats

Owner s Manual. SYSTXBBECW01 & SYSTXBBECN01 Evolutionr Connext Control. NOTE: Read the entire instruction manual before starting the installation.

Communicating Wall Control Owner s Manual TSTAT0101SC

SE7600E Series Application Guide

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

Field selectable application type and room module series, via dip-switches on controller

Description. descriptors, makes set-up and monitoring very user friendly.

i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building

Semi flush-mounted room temperature controllers with LCD

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

Semi flush-mounted room temperature controllers with LCD

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Control systems. Efficient room control

75F Smart VAV with Reheat

THERMOSTATS & CONTROLLERS

Fast Route to Reliable Energy Savings ZIP Economizer

Andover ContinuumTM. b3850 Series Terminal Controllers

Andover ContinuumTM Infinet II

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Installation Manual. DZK BACnet

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Installation and Operation Instructions

RWD68U Universal Controller

OP10. Pre-programmed, configurable controller for simple applications

Room unit with PPS2 interface

L Connection Network Control System For Energence Rooftop Units

VZ7000 Series. BACnet Commercial Zoning System

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications

TF243 Series Digital Thermostat Fan Coil Unit Control

Semi Flush-mount Room Temperature Controllers with LCD

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Room controller STRA-17

PROLON INSTALLATION AND START UP GUIDE

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

SEZ7000 Series. Wireless Commercial Zoning System

Satchwell MicroNet. Building Management System MicroNet 50 Series

Owner s Manual. SYSTXBBECW01 -A, SYSTXBBECN01 -A & SYSTXBBECC01 -A Evolutionr Connext Control

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

Daikin HVAC Controls Guide Specification

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

Totaline Thermostats. Three Series To Meet Any Specification. Exceptional WARRANTY Application VERSATILITY

SMART VENTILATION MANAGEMENT: CHANGING THE WAY WE THINK ABOUT VENTILATION

Universal Controller

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC

Wiring Diagrams INDEX. UNIT DESCRIPTION DRAWING NUMBER FIG. NO. 09DK Field Wiring 09DK DK054,064

HLS34 Modbus FCU/VAV Controllers installation instructions

AHU Solutions Programmable controllers for air handling units

System Controls Suggested Specification

Master room unit for RRV controllers

Instructions for Installing Observer Control Version 6.0/3.19 Software rev

Operation 6035 ENGLISH PROG MENU

TC-8900 Controller Units with PM-8900 Power Modules

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

ECL Comfort V a.c. and 24 V a.c.

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

AirTouch 2 Zone Control System

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Control4 Audio Products

ECON-ZIP-BASE. ZIP Economizer Base Module

FCU-4 FAN COIL CONTROLLER

Pre-programmed room controller with display and communication

Operation Guide CT100

ECONOMIZERS. Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH UNITS CAUTION WARNING

Actuating Terminal Equipment Controller (ATEC) VAV with Reheat. Start-up Procedures Building Technologies Restricted

CTXA-AS/AT/AW, FTXA-AS/AT/AW

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

Pre-programmed room controller with display and communication

TC-9102 Terminal Controller

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM Infinet II

GLAS Smart Thermostat

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

CCS Handheld VAV Balancing Tool Technical Bulletin

Options Overview. February 6, Ben Newell

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

SER8300 Room Controller

TAC Xenta 121-HP Programmable Heat Pump Application

OPERATION MANUAL.

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Operation Guide CT101

Room unit with PPS2 interface

Room Temperature Controller

TM-2100 Series Room Command Module

7. PCB AND FUNCTIONS

Transcription:

SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL Product Data NOTE: Evolution Zone Control compatible with Evolution rated indoor equipment only. EVOLUTION t ZONE CONTROL Bryant specializes in creating a customized home comfort system tailored to your needs with our broad selection of residential heating and cooling products. The Evolution Zone Control System is the ultimate control center for all of your system components. When you add an Evolution Zone Control to a compatible variable speed furnace, fan coil, or small packaged product, you will enjoy longer heating and cooling cycles at lower fan speeds for a more consistent temperature throughout your home. By adding an Evolution or Preferred Series compatible outdoor unit, your benefits will increase even more. Benefits include better humidity and temperature control as well as a more energy efficient comfort system. INDUSTRY LEADING FEATURES/BENEFITS Bryant s revolutionary Evolution Zone Control is the smart control of the future. The Evolution Zone Control features a large backlit liquid crystal display, making it easier to read the temperature, even at night. Intuitive prompts let you program everything from humidity levels to fan speeds, giving you ultimate control over your home comfort. The Evolution Zoning system does not require a bypass damper, leaving air temperature (LAT) sensor, or a field supplied power transformer. Up to 8 zones of control Patented automatic duct assessment design compensates for duct work variability No bypass damper required or recommended No LAT or HPT sensors required or recommended No field -installed transformer required Fan airflow adjustment by zone 4 wire installation from each component in the system Intuitive on screen prompts for ease of installation and service Perfect Humidityt settings are the default, no longer requiring increased system setup Complete integration of the temperature, humidity, and ventilation in every season TrueSenset Dirty Filter Detection Indoor Air Quality pop -up reminders 7 day programmability with 2 or 4 periods per day Easy timed override schedule Simplified vacation schedules Day -at -a -glance programming for simplified ease of use Programmable fan by period General maintenance reminder messaging Optional Remote Access Kit can be added for access to your system from the internet or phone

MODEL NUMBER NOMENCLATURE SYSTX BB UIZ 01 -B Product Type Brand Model Type Packaged Quantity Software Version Evolution System Bryant UIZ - Zone User Interface 4ZC - Damper Control Module NIM - Network Interface Module SAM - System Access Module RRS - Remote Room Sensor LBP - Large Backplate GRP - Green ABCD Connector SYSTXBBUIZ01--B As an Energy Star Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency TM 3.56" 90.4 mm 3.56" 90.4 mm 0.98" 25 mm 0.37" 9.5 mm 1.34" 34.2 mm 0.37" 9.5 mm WALL WALL 6.00" 152.4 7.39" 187.5 mm Fig. 1 Unit Dimensions A07255 A07256 A07257 Recessed Mount Surface Mount 2

3.4" 86.4 mm 1.0" 25.4 mm 3.3" 83.8 mm.75" 19.1 mm 4.0" 101.6 mm 2.5" 63.5 mm HOLD Fig. 2 Smart Sensor Dimensions ZONING EQUIPMENT Evolution Zone Control Evolution Network Interface Module (NIM) Evolution Damper Control Module (4 Zone) A07283 NOTE: Each piece of zoning equipment is sold separately allowing for customization of the zoning application. * Required to control ventilator (when zoning is not applied) * Required to control a non---communicating heat pump in Hybrid Heatt applications. * Required to control a non---communicating 2---stage AC or HP (i.e. R---22 Series A) { One damper control module handles up to 4 zones. A second damper control module is needed for zones 5---8. OPTIONAL ACCESSORIES Evolution System Smart Sensor Evolution Remote Room Sensor (RRS) Evolution Large Decorative Backplate Green Indoor Unit Plug (ABCD Connector) --- 10 Pack Replacement Evolution System Access Module (SAM) Evolution System Access Module (Remote Access Kit, Skytel--- based) Evolution System Access Module (Remote Access Kit, Ethernet) Evolution System Access Module (Remote Access Kit, WiFi--- Ethernet) * A combination of Evolution Smart Sensors and Evolution Remote Room Sensors can be used in the zones. REPLACEMENT ACCESSORIES TSTATBBSEN01---B ATO1 *Available from RCD DAMPERS Round Dampers Rectangular Dampers Rectangular Barometric Bypass Round Barometric Bypass Fig. 3 Remote Room Sensor Dimensions Outdoor Sensor Damper Control Module 1---amp Fuse* SYSTXBBUIZ01--- B SYSTXBBNIM01* SYSTXBBZC01{ SYSTXBBSMS01* SYSTXBBRRS01 SYSTXX0LBP01 SYSTXGRPLG10 SYSTXBBSAM01 SYSTXBBSAM01 SYSTXBBCAT501 SYSTXBBWIFI01 6 / 152.4 mm DAMPRND06INC--- B 8 / 203.2 mm DAMPRND08INC--- B 10 / 254 mm DAMPRND10INC---B 12 / 304.8 mm DAMPRND12INC--- B 14 / 355.6 mm DAMPRND14INC--- B 16 / 406.4 mm DAMPRND16INC--- B 8 X 10 / 203.2 X 254 mm DAMPREC08X10---B 8 X 14 / 203.2 X 355.6 mm DAMPREC08X14---B 8 X 18 / 203.2 X 457.2 mm DAMPREC08X18---B 8 X 24 / 203.2 X 609.6 mm DAMPREC08X24---B 10 X 10 / 304.8 X 304.8 DAMPREC10X10---B 10 X 14 / 304.8 X 355.6 mm DAMPREC10X14---B 10 X 18 / 304.8 X 457.2 mm DAMPREC10X18---B 10 X 24 / 304.8 X 609.6 mm DAMPREC10X24---B 8 X 14 / 203.2 X 355.6 mm DAMPBAR08X14 8 X 24 / 203.2 X 609.6 mm DAMPBAR08X24 8 / 203.2 mm DAMPBAR08INC 10 / 254 mm DAMPBAR10INC 12 / 304.8 mm DAMPBAR12INC 14 / 355.6 mm DAMPBAR14INC 16 / 406.4 mm DAMPBAR16INC A07284 SYSTXBBUIZ01--B 3

SYSTXBBUIZ01--B DAMPERS (cont) Slip --- In Dampers Side mount, 8 X 8 / 203.2 X 203.2 mm Bottom mount, 8 X 8 / 203.2 X 203.2 mm Side mount, 8 X 10 / 203.2 X 254 mm Bottom mount, 8 X 10 / 203.2 X 254 mm Side mount, 8 X 12 / 203.2 X 304.8 mm Bottom mount, 8 X 12 / 203.2 X 304.8 mm Side mount, 8 X 14 / 203.2 X 355.6 mm Bottom mount, 8 X 14 / 203.2 X 355.6 mm Side mount, 8 X 16 / 203.2 X 406.4 mm Bottom mount, 8 X 16 / 203.2 X 406.4 mm Side mount, 8 X 18 / 203.2 X 457.2 mm Bottom mount, 8 X 18 / 203.2 X 457.2 mm Side mount, 8 X 20 / 203.2 X 508 mm Bottom mount, 8 X 20 / 203.2 X 508 mm Side mount, 8 X 22 / 203.2 X 558.9 mm Bottom mount, 8 X 22 / 203.2 X 558.9 mm Side mount, 8 X 24 / 203.2 X 609.6 mm Bottom mount, 8 X 24 / 203.2 X 609.6 mm Side mount, 10 X 10 / 254 X 254 mm Bottom mount, 10 X 10 / 254 X 254 mm Side mount, 10 X 12 / 254 X 304.8 mm Bottom mount, 10 X 12 / 254 X 304.8 mm Side mount, 10 X 14 / 254 X 355.6 mm Bottom mount, 10 X 14 / 254 X 355.6 mm Side mount, 10 X 16 / 254 X 406.4 mm Bottom mount, 10 X 16 / 254 X 406.4 mm Side mount, 10 X 18 / 254 X 457.2 mm Bottom mount, 10 X 18 / 254 X 457.2 mm Side mount, 10 X 20 / 254 X 508 mm Bottom mount, 10 X 20 / 254 X 508 mm Side mount, 10 X 22 / 254 X 558.9 mm Bottom mount, 10 X 22 / 254 X 558.9 mm Side mount, 10 X 24 / 254 X 609.6 mm Bottom mount, 10 X 24 / 254 X 609.6 mm Side mount, 12 X 12 / 304.8 X 304.8 mm Bottom mount, 12 X 12 / 304.8 X 304.8 mm Side mount, 12 X 14 / 304.8 X 355.6 mm Bottom mount, 12 X 14 / 304.8 X 355.6 mm Side mount, 12 X 16 / 304.8 X 406.4 mm Bottom mount, 12 X 16 / 304.8 X 406.4 mm Side mount, 12 X 18 / 304.8 X 457.2 mm Bottom mount, 12 X 18 / 304.8 X 457.2 mm Side mount, 12 X 20 / 304.8 X 508 mm Bottom mount, 12 X 20 / 304.8 X 508 mm Side mount, 14 X 14 / 355.6 X 355.6 mm Bottom mount, 14 X 14 / 355.6 X 355.6 mm Side mount, 14 X 16 / 355.6 X 406.4 mm Bottom mount, 14 X 16 / 355.6 X 406.4 mm Side mount, 14 X 20 / 355.6 X 508 mm Bottom mount, 14 X 20 / 355.6 X 508 mm Side mount, 16 X 16 / 406.4 X 406.4 mm Bottom mount, 16 X 16 / 406.4 X 406.4 mm Bottom mount, 16 X 20 / 406.4 X 508 mm DAMPSLS08X08---B DAMPSLB08X08---B DAMPSLS08X10---B DAMPSLB08X10---B DAMPSLS08X12---B DAMPSLB08X12---B DAMPSLS08X14---B DAMPSLB08X14---B DAMPSLS08X16---B DAMPSLB08X16---B DAMPSLS08x18---B DAMPSLB08X18---B DAMPSLS08X20---B DAMPSLB08X20---B DAMPSLS08X22---B DAMPSLB08X22---B DAMPSLS08X24---B DAMPSLB08X24---B DAMPSLS10X10---B DAMPSLB10X10---B DAMPSLS10X12---B DAMPSLB10X12---B DAMPSLS10X14---B DAMPSLB10X14---B DAMPSLS10X16---B DAMPSLB10X16---B DAMPSLS10X18---B DAMPSLB10X18---B DAMPSLS10X20---B DAMPSLB10X20---B DAMPSLS10X22---B DAMPSLB10X22---B DAMPSLS10X24---B DAMPSLB10X24---B DAMPSLS12X12---B DAMPSLB12X12---B DAMPSLS12X14---B DAMPSLB12X14---B DAMPSLS12X16---B DAMPSLB12X16---B DAMPSLS12X18---B DAMPSLB12X18---B DAMPSLS12X20---B DAMPSLB12X20---B DAMPSLS14X14---B DAMPSLB14X14---B DAMPSLS14X16---B DAMPSLB14X16---B DAMPSLS14X20---B DAMPSLB14X20---B DAMPSLS16X16---B DAMPSLB16X16---B DAMPSLB16X20---B DAMPER REPLACEMENT ACCESSORIES 45_ Actuator for round dampers DAMPACT45DEG--- R Actuators 90_ Actuator for rectangular dampers DAMPACT90DEG--- R Damper Actuator Cover DAMPACTXXCOV Damper Control Module 1---amp Fuse ATO1* *Available from RCD. 4

Compatible Products Air Conditioning units - 180A, 187A, 165A, 163A Heat Pumps - 288A, 286A, 265A, 264A, 263A Gas Furnace - 355AAV, 315AAV, 315JAV, 355BAV, 355CAV Fan Coils - FE Small Packaged Products - 707B, 607B, 577B, 677B, 704C, 604C, 574C, 577D, 707D, 607D, 677D Physical Characteristics of SYSTXBBUIZ01 Dimensions: See drawing Appearance: Plastic, white color, textured Physical Characteristics of SYSTXBBSMS01 Dimensions: 4.0 / 101.6 mm high x 3.4 / 86.4 mm wide x 1.0 / 25.4 mm deep Appearance: Plastic, white color, textured Physical Characteristics of SYSTXBBRRS01 Dimensions: 2.5 / 63.5 mm high x 3.3 / 83.8 mm wide x 0.75 / 19.1 mm deep Appearance: Plastic, white color, textured Electrical Characteristics/Communication Input Volts/Amps 24VAC Each device in the Evolution System has a four-pin connector labeled ABCD. It is recommended that the following color code be used when wiring each device: A Green = Data A B Yellow = Data B C White = 24VAC (Com) D Red = 24VAC (Hot) Environmental Requirements: Operating Temperature/Relative Humidity: User interface and all sensors: 32_F to 104_F / 0_C to 40_C, 95% rh non -condensing Storage Temperature/Relative Humidity: User interface: - 40_F to 134_F /-40_C to 56.7_C, 95% rh non -condensing Damper Control Module: -40_F to 185_F /-40_C to85_c, 41% rh non -condensing PRODUCT DATA INFORMATION Applications: Hybrid Heatt (Heat pump with gas furnace backup) Program Specifications: Temperature setpoint range: 40_F to90_f /4.4_C to 32.2_C Separate heat and cool setpoints Programming days: 7 day Programming periods: 2 -Day, Sleep 4 -Wake, Day, Eve, Sleep Auto changeover (may be disabled) Programmable fan (installer selectable) Humidity Sensor Offsets Auto Changeover Timer (installer adjustable) Smart Recovery (in heating and cooling) Hold function Copy functions: Copy period, day and zone Permanent memory Humidity display and control Temperature sensor offsets (indoor and outdoor) TrueSenset Dirty Filter Detection Wiring Requirements: Power supply: Dedicated 24VAC, 40 va, 60 Hz, via indoor equipment ABCD Connector. Isolated transformer, field supplied. Wiring material: Standard thermostat wire 18 to 24 gauge. SYSTXBBUIZ01--B 5

SYSTXBBUIZ01--B E2007 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 04/07 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No: PDSUIZ.01.3 Replaces: PDSUIZ.01.2 6