EZ Series In-Site CL control panel EZ Connect Mobile ios User Guide

Similar documents
Configuration Utility

Image from Google Images tabtimes.com. CS87 Barbee Kiker

Quick Start Guide: esignature & On-the-Spot App

Document Number: /4/2012

IFLEX SETUP INSTRUCTIONS FOR IPAD

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

LYNX Monitors USER & INSTALLER'S MANUAL ENGLISH

cmt Quick Start Guide

CONNECT. Instructions for use. ios

Save and Restore Backups using itunes File Sharing

Mobile Print Guide for Brother iprint&label (Apple Devices)

iphone Backup 1 P a g e

Accessing VXView 3. Checking Messages 4. Folder Tabs/Toolbar 5. Message Area 6. Almost Full Warning 7. Managing Address Books 8. Adding a Contact 9

How to set up Restrictions on the ipad

1 PoolManager 5 Software Releases Overview

LVM Touch Screen Centralized Controller

Save and Restore Backups using itunes File Sharing

uremote User Manual Version 1.3 Jan 2017

Windows user guide for version 3.3

If you get stuck at any point, please let us know! We love talking to our customers! You can reach us at the number below:

Mobile App Installation & Configuration

PureAudio Live Recorder User Guide

Connecting to your Caravan or Motorhome

ipad Basics Hannah Digital Literacy Specialist December 6 th, 2017

Chapter 1 Preparing Your ipads for Q-interactive

Microsoft Office 365 for Education

User s Guide to Breeze Web Application. Page 1

Roomie Remote 3. Setting Up Devices ABOUT DEVICES PREREQUISITES

INNOV.NET PTY LTD. User guide

INSTALLATION & OPERATING INSTRUCTIONS when Touch-5 Wi-Fi Module is Installed in PCR-4 Driver/Receiver

To configure Exchange ActiveSync on the device the following information is needed.

Acronis and Acronis Secure Zone are registered trademarks of Acronis International GmbH.

INNOV.NET PTY LTD. User guide

Q: Why do my multiple devices alert at different times when I separate from them?

HOW TO GET YOUR iphone UP AND RUNNING

LYONESS V-TERM. Instruction Manual.

IntraLinks Mobile for ipad User Guide

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Veris Sensors App. Quick Start Guide Pressure Monitoring. For Use with Differential Pressure / Air Velocity Transducers. Introduction.

CONTROL TECHNOLOGY CORPORATION. qmon User's Guide. Control Technology Corp

ipad Settings Turn on icloud Backup Go to Settings, icloud. From here you can choose what items you want to have backed up.

Salesforce Classic Guide for iphone

Manual for the Bellfires Wi-Fi box in combination with the Bellfires Gas app

Pairing two devices with the Belkin QODE Ultimate Pro and Slim Style Keyboard Cases

Office 365 Mobile Instructions. Setup on Apple (iphone, ipad) devices

Lutron Home Control+ App for the Apple ipad TM, iphone TM and ipod touch

Making Best Use of Your Tablet. Talk prepared by Angela Briggs February 2018

Prez Pro support documentation

Browse the internet, send and receive s and text messages, play music and movies, take and display photos and videos, and more.

AD-300 AD-301 NETWORKED HARDWIRED LOCK USER GUIDE

Apps Every College Student Should Have

InfraWare Mobile. for ios. Published October 06, 2015

Table of contents. 1 Instructions 3. 2 Enrolment and Verification 8. 3 Lock Function Information and Settings Other Functions 18.

USER & INSTALLATION MANUAL SMART-R BN86

Bombardier Flight Deck app

Startup Guide for Android. Intralinks VIA Version 3.2

Connection Guide (for D SLR Cameras) En

2015 LaMotte Chemical Products Company. Mobile App User Guide

FOCIS Flex Inspection

Valley Irrigation Run Time App Version 1.1

Organize Your iphone: Icons and Folders

Integration with Apple Configurator 2. VMware Workspace ONE UEM 1902

Mobile Apps Introduction Getting Started Features Resources

Manual Software Ios 6 For Ipod Touch 4 Ios 6 >>>CLICK HERE<<<

ComNav Installation Manual

Basics. Devices and Technical Requirements. Teaching Strategies GOLD Documentation App Frequently Asked Questions

Startup guide. Harmony Companion remote. Harmony Hub. Power adapter

The purpose of this document is to help you to get started with your ipad to access Lilly resources such as , calendar, Lilly apps and more.

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

DIESEL ON: FAQS I PRESS THE BUTTON BUT THE HANDS JUST SPIN AROUND ONCE AND THEN STOP. WHAT'S WRONG?

Heading. idevices Connected. App Manual. HomeKit Products

PANTA RHEI USB-Adapter

Use Office 365 on your iphone or ipad

Mobile Pay Plus Get Started Guide

PhotoFrame SPF1017 SPF1027. Quick start guide. 1 Get started 2 3. Play. Setup

CONTENTS. Using the Emperia Scan app 3. Using the Web Portal to access leads 6 FAQ 9

EQ Showroom App Setup & Instructions

Community Mobile Patrol Officer User Guide v13.4

TPS ISS ipad Setup Process. Setup your mobile Device

The Experts in Vacuum Solutions

HOW TO CONFIGURE FREY CHART PANEL WITH ipad. keeping an eye on vision

StarryBay. User Guide

Wi-Fi EVERIO, NOW WITH Wi-Fi Reference

ONYX FINGERPRINT PASSWORD LOCK MANUAL

LIGHTCAST V1.2 Software Guide for projectors

PNY DUO-LINK On-The-Go Flash Drive for iphone and ipad. User Manual

MetaTrader 4 for iphone. User Manual

QUICK START GUIDE NTS HOSTED PBX CALL MANAGER. Welcome. Getting Oriented

Lab - Working with ios

How to use the HTC Desire C mobile devices

Salesforce Classic Mobile Guide for iphone

User Guide: Sprint Direct Connect Plus - ios. User Guide. Sprint Direct Connect Plus Application. ios. Release 8.3. December 2017.

CITRIX NAVIGATION & ACCESSING myhr

Getting Started with Lync 2010 for iphone

Syncing ipad devices using itunes

DENT Instruments ELITEpro Mobile App

Before You Begin: Removing your GOS Account from the mail application installed on your ios device.

SCAN LEARN MORE. iw4 Start Guide Visit our website for additional help and how-to videos

Levelogger App & Interface User Guide

The Experts in Vacuum Solutions

Transcription:

SUPPORTED PLATFORMS EZ Series In-Site CL control panel EZ Connect Mobile ios User Guide Revision 0.1 The EZ Connect Mobile ios application was developed for use with Apple phones and ipads that meet the Minimum Device Requirements listed below. Running the application on Apple devices that do not meet the Minimum Device Requirements is not recommended and may result in improper operation. MINIMUM DEVICE REQUIREMENTS ios, version 9.x.x or higher Bluetooth 4.0 or higher Capable Devices include: iphone 4S or newer, ipad (3rd generation) or newer, ipad Air, ipad Mini, and ipad Pro APPLICATION PURPOSE The EZ Connect Mobile ios application is provided to support the EZ Series In-Site CL panel. EZ Connect Mobile ios has three primary functions: Set operation parameters in the EZ Series In-Site CL panel to control panel operation. Observe panel operation through the applications level bar graph, pump elapsed time meters, and pump cycle counters. Transfer events stored in the panel s event log as a fi le to an email recipient. That fi le can then be used by the In-Site Reporting program on a Windows-based PC. The ios application uses Bluetooth Smart communications to interface with the EZ Series In-Site CL. DEFINITIONS Term Definition Panel EZ Series In-Site CL Panel with Bluetooth Device Application Button A hand-held ios-based mobile tablet or phone. A program that runs on the device. In this document, except where noted, application refers to the EZ Connect program running on the device. The buttons referred to in this guide are display icons, not physical push buttons. The button name will be in caps (e.g. BUTTON) regardless of the font used for the actual display. 1 EZ Connect Mobile ios User Guide

CONNECTING THE DEVICE TO AN EZ Series In-Site CL PANEL Open the panel and position the communications switch in the BT Module position as shown below. The switch must remain in this position to allow operation with the mobile device. On the mobile device, open the Settings application (not the EZ Connect application). Then select the word Bluetooth. Ensure Bluetooth is ON. Toggle if not green to ON EZ Connect Mobile ios User Guide 2

CONNECTING THE DEVICE TO AN EZ Series In-Site CL PANEL If the application has not been downloaded or installed, fi rst follow steps in the EZ Series InSite CL Bluetooth Installation Instructions and Operation/Troubleshooting Manual before proceeding. To launch the EZ Connect application, the operator must fi rst connect to the panel by selecting the CONNECT button in the Panel Connection Display. The application displays all available panels that can be connected. The panel name is printed on the label located on the black inner panel. the panel name to connect. App Download EZI (00:11:22:0D:33:C9) PIN 123456 EXAMPLE OF LABEL Panel Name The application will prompt you for a password. The PIN is printed on the label located inside of the front door of the panel. Enter the PIN and select Enter. Note: The application will remember the PIN for future connection attempts. App Download EZI (00:11:22:0D:33:C9) PIN 123456 EXAMPLE OF LABEL PIN The panel will connect to the mobile device and automatically begin reading data and parameters. When that process completes successfully, the Status Display will be shown. 3 EZ Connect Mobile ios User Guide

RENAMING AN EZ Series In-Site CL PANEL On the Panel Connection display, the operator has the option to rename the panel to a more descriptive name. For example, in the display below, EZI (00:13:43:0D:23:C9) has be renamed to 1234 Elm St. for easier identifi cation. Once desired name has been entered, select RENAME PANEL. Note: It is important to be descriptive in a situation where multiple panels are in range to avoid connecting to the wrong panel. Enter new panel name SETTING PUMP PARAMETERS (PUMP SETTINGS tab) Note: When any settings are changed, the APPLY button must be selected to send the value to the panel. NOTE: When changing parameters of operation (settings), the application keeps track of pending changes and displays a red banner warning message as shown below: Setting changes must be applied for them to take effect. The APPLY button must be selected to make the changes effective, at which time the red banner warning message will disappear. If a user attempts to exit after changing parameters without selecting the APPLY button, the application will display the above red banner warning message. The user has the option to apply the changes or continue exiting the display without applying changes. Navigate to the Pump Settings Tab by clicking PUMP, or swiping to the correct page. Setting Pumping Operation To change pumping operation, select the value. A display with value options will appear. the desired operation. If the value is changed to Demand Dose, timing parameters will not appear on the display; if the value is changed to Timed Dose, timing parameters will appear. EZ Connect Mobile ios User Guide 4

Setting Pump Configuration To change Pump Confi guration, select the value. A display with value options will appear. the desired confi guration. If the value is set to Simplex, the Pumping Sequence parameter will not appear in the display; if the value is set to Duplex, the Pumping Sequence parameter will appear. Note: If the Pump Confi guration parameter is changed, the panel will be set to an HOA OFF state. The operator must manually put the panel into the HOA AUTO state for normal operation. Setting Pumping Direction To change Pumping Direction, select the value. A display with value options will appear. the desired direction. It is very unusual to change this parameter after the panel is installed. Note: Incorrect settings can cause panel settings to reset. Note: If the Pumping Direction parameter is changed, the panel will be set to an HOA OFF state. The operator must manually put the panel into the HOA AUTO state for normal operation. Setting Pumping Sequence This parameter will only appear if the Pump Confi guration is set to Duplex. the value for Pumping Sequence to change it. A display with value options will appear. the desired sequence. 5 EZ Connect Mobile ios User Guide

Setting Timed Dose Parameters Timed Dose parameters will only appear if the Pumping Operation is set to Timed Dose. To change the Time Dose Parameters, select the value. To change the time interval, select the value. A keypad allows a new time to be entered. The time is displayed as HH:MM:SS where HH is hours (0 to 99), MM is minutes (0 to 59), and SS is seconds (0 to 59). The colons do not need to be entered. DONE when the correct interval value is entered. DONE when the correct interval value is entered. time digits using the picker. EZ Connect Mobile ios User Guide 6

SETTING LEVEL PARAMETERS (LEVEL SETTINGS tab) Note: When any settings are changed, the APPLY button must be touched to send the value to the panel. NOTE: When changing parameters of operation (settings), the application keeps track of pending changes and displays a red banner message as shown below. Setting changes must be applied for them to take effect. The APPLY button must be selected to make the changes effective, at which time the banner message will disappear. If a user attempts to exit after changing parameters without selecting the APPLY button, the application will display a warning message. The user has the option to return to apply the changes or continue exiting the display without applying the changes. Navigate to the Level Settings Tab by clicking LEVEL, or swiping to the correct page. Setting Level Units To change the value for Level Units, select it. A display will appear. the desired units. Setting Level Transducer Range To change the value for Level Transducer Range, select it. A display will appear. the desired range. 7 EZ Connect Mobile ios User Guide

Setting Gauge Range The Gauge Range is the value of the level at the top of the level graph on the Status Display. The Gauge Range must be equal to or less than the Level Transducer Range. Values shown in parentheses (0 40 shown below) show the minimum and maximum values for the range. Touch the value for Gauge Range to change it. When the value is touched, a keypad will appear to change the value. Using the keypad, enter a valid range value. The application will not allow an incorrect value to be entered. Setting Alarm Setpoint The Alarm Setpoint is the level above which the alarm will activate (or level below if pumping up). The alarm can be any value less than or equal to the Level Transducer Range. To change Alarm Setpoint select the value. A keypad allows a new value to be entered. EZ Connect Mobile ios User Guide 8

Setting Level Setpoints Level Setpoint names vary depending on the Pump Operation (Demand or Timed Dosing) and the Pump Confi guration (Simplex or Duplex). See table below. Simplex Duplex Demand Dose Timed Dose Demand Dose Timed Dose Stop Redundant Off Stop Redundant Off Start Timer Enable lead Timer Enable Timer Override Lag Timer Override For example below, Demand Dose, Duplex are used. To change Level Setpoint, select the value. A keypad allows new values to be entered. setpoint value to change Values shown in parentheses display the minimum and maximum values for the range that can be entered. Minimums and maximums are based on adjacent setpoint values. Setpoint value ranges must meet the following guidelines: 1. Stop must be at least 3 and no greater than the Lead value (3 to 17). 2. Lead must be greater than Stop but less than Lag (13 to 23). 3. Lag must be greater than Lead but less than the Level Transducer Range (19 to 39). 9 EZ Connect Mobile ios User Guide

STATUS DISPLAY (STATUS tab) The Status Display shows the following information: Graphical and numeric representation of the current Tank Level (1). Graphical and numeric representation of Level Setpoints (2). Information for each pump: o HOA State (3) o Running State (4) o Pump Elapsed Run Time (5) o Pump Cycle Count (6) Panel control board ID, application software revision, and panel clock time (7) Panel fi rmware revision (8) Pump Related Functions: o Changing the HOA state (9) o Resetting the Run Time (10) o Resetting the Cycle Count (11) Status Display Information: o Synchronize the panel s clock to the mobile device s clock (12) o Download the current In-Site log (13) Note: The Status and Pump Status Display will be presented as two separate displays for devices with low display resolution, such as phones. This guide will only show information as a single display. 7 8 2 4 3 5 6 9 10 11 1 12 13 EZ Connect Mobile ios User Guide 10

ALARM INDICATION Pumping Direction set to Down If the level rises above the alarm setpoint, the alarm level icon will fl ash indicating a high level alarm. If the level rises above the Lag or Timer Override level, the respective level icon will fl ash indicating the condition. Pumping Direction set to Up If the level drops below the alarm setpoint, the alarm level icon will fl ash indicating a low level alarm. If the level drops below the Lag or Timer Override level, the respective level icon will fl ash indicating the condition. A Level Alarm will remain active until the level is not at or beyond the alarm setpoint or the alarm setpoint is changed. CHANGING PUMP HAND-OFF-AUTO (HOA) SETTING To change the HOA state of a pump, select and hold the state and select Hand, Off, or Auto. RESETTING PUMP RUN TIME To change the Run Time state of a pump, select and hold the time value. A message will appear to verify the user wants to erase the time to 00:00. ing YES will erase (reset) the time in the panel - it does not have to be applied. The erase (reset) cannot be reversed. RESETTING PUMP CYCLE COUNT To change the Cycle Count state of a pump, select and hold the count value. 11 EZ Connect Mobile ios User Guide

A message will appear to verify the user wants to erase (reset) the count to 0. ing YES will erase (reset) the cycle count in the panel - it does not have to be applied. The erase (reset) cannot be reversed. SYNCHRONIZING THE PANEL CLOCK The panel s internal time-of-day clock can be set to the device s time. Typically, the device time is updated through a web connection and is accurate. To synchronize the time, select the SYNC CLOCK button. The panel s clock (called Panel Time on the display) will automatically be set in the device s clock. Panel Time is set to device time. EZ Connect Mobile ios User Guide 12

DOWNLOADING THE In-Site LOG The In-Site log can be downloaded to the device and sent as a fi le to an email recipient or saved to your PC via itunes. the DOWNLOAD LOG button and the Download Log page will be displayed. To begin downloading the log select the DOWNLOAD LOG button, a progress bar will appear and indicate how much of the log has been downloaded. When the log has fi nished downloading it will be added to the list of log fi les that are saved on the device. Files saved on your device can be deleted, renamed, or emailed. for fi le options. File Name Entry File Option If you select DELETE you will get a confi rmation popup. If you select RENAME you will get a confirmation popup. Note: The fi le will get renamed to the contents of the File Name Entry. 13 EZ Connect Mobile ios User Guide

If you select EMAIL, and have set up an email account on your device, you will be directed to your Email client. Enter an Email address and select Send. Most commonly, the Email will be received on a Windows-based PC that has the In-Site Reporting application. If you have not set up an Email account on your device, go into your device SETTINGS, navigate to MAIL, CONTACTS, CALENDARS, and select ADD ACCOUNT. Follow the instructions to add an Email account. Alternatively, you can download your In-Site log fi les via itunes. Run itunes and plug your device into your PC, when itunes recognizes your device it will show up in the top left, select the icon when it appears. Navigate to Apps, then scroll to the bottom of the page and fi nd File Sharing. If EZ Connect is installed on your device, it should be listed in Apps. it and the list of your saved log fi les will be available in EZ Connect Documents. You can save the fi les to a location of your choice and open them with In-Site Reporting Software. 1 Your Device 2 Apps 3 Scroll Down 4 EZ Connect 5 Files 6 Save to... 1 2 4 5 3 6 EZ Connect Mobile ios User Guide 14

LOADING SAVED PARAMETER SETTINGS The Load Settings function allows previously saved parameter settings to be loaded or deleted. Settings can only be loaded from one of the settings displays. If loading is desired but current parameters have been modifi ed, they either need to be applied or cancelled before new settings can be loaded. To load settings, select the LOAD SETTINGS button and it will display the Load Settings page. A list of saved settings will appear if you have previously saved settings. the desired setting. A Settings Options popup will appear with a list of options to select from. desired setting DELETE Or LOAD To load a fi le, select LOAD, and your settings will be loaded. To delete a fi le, select DELETE. A confi rmation message appears to confi rm the user wants to delete the fi le. Press YES to delete the fi le or NO to cancel. 15 EZ Connect Mobile ios User Guide

SAVING PARAMETER SETTINGS The Save Settings function allows parameter settings to be saved to a device fi le. Settings can only be saved from one of the settings displays. If saving is desired but current parameters have been modifi ed, they need to be applied or cancelled before new settings can be saved. To save settings, select the SAVE SETTINGS button and it will display the Save Settings page. A list of Saved Settings will appear if you have previously saved some settings. the desired setting. A settings options popup will appear with a list of options to select from. To save a new setting select the SAVE SETTINGS button. Note: If you don t edit the fi le name in the File Name entry, the fi le will be saved as the default name. DELETE Or LOAD To delete a fi le, select DELETE. A confi rmation message appears to confi rm the user wants to delete the fi le (this will be the same as on the Load Settings Page). To rename a fi le, select RENAME. A confi rmation message appears to confi rm the user wants to rename the fi le. Note: the selected fi le will be renamed to the text entered in the File Name entry. Press YES to rename the fi le or NO to cancel. EZ Connect Mobile ios User Guide 16 SJE-Rhombus 1047057A 03/16