QCS DESKTOP SERVER OR OPERATOR STATION ON WIN10 ENTERPRISE 64 BIT Where Used: 65120593, 65120594, 651206 Page 1 of 74 Contents 1. About this Document... 2 2. Motherboard Layout of T5810 Workstation... 2 3. Overview of ESIS... 4 3.1. Setting up an ESIS repository... 4 3.2. ESIS folder mapping... 13 4. Installing the Operating System for Desktop Server or Operator Station... 14 4.1. Desktop Server Checklist... 14 4.2. QCS Operator Station Checklist... 14 4.3. Windows Operating System only Checklist... 14 5. Install the add on Broadcom Dual Port NIC Hardware (Optional)... 15 6. Enable the Embedded NIC (Optional)... 15 7. Experion PKS System Installation... 16 7.1. Generation of Configuration Files... 16 7.1.1. Generating the Configuration Files for Desktop Server... 19 7.1.2. Generating the Configuration Files for QCS Operator station... 34 7.1.3. Generating the Configuration Files for Windows Operating System only... 48 7.2. Installing the Desktop Server... 54 7.3. Installing the QCS Operator Station... 57 7.4. Installing the Windows Operating System only... 61 8. Monitor Connection settings... 67 9. Set the display Properties... 68 9.1.1. Display Properties Configuration for Single Monitor... 68 9.1.2. Display Properties Configuration for Dual Monitor... 71 10. Installing the RAE... 74 Related documents EPDOC-XX36-en-5A Experion PKS Fault Tolerant Ethernet Installation and Service Guide 65120594 Real-Time Application Environment (RAE) R7.1 with Experion R5.1 Release and Installation Notes Senior Manager, Engineering: Manager, Engineering: DCC: Originator: Hrishikesh Thakre Burton, Bethann Rajesh A.R/Barun Paul DATE: DATE: DATE: DATE: April 6, 2017 Rev Original Date Issued: April 6, 2017
Where Used: 65120593, 65120594, 651206 Page 2 of 74 1. About this Document This document provides the procedure to produce a QCS Desktop Server or a QCS Operator Station for RAE R70x.x systems. 2. Motherboard Layout of T5810 Workstation Figure 1 Motherboard Layout of T5810 Workstation
Where Used: 65120593, 65120594, 651206 Page 3 of 74 Table 1 Slots in the Motherboard Layout Number Name Number Name 1. PCI slot (slot 6) 2. PCIe x16 slot (PCIe 2.0 wired as x4) (slot 5) 3. PCIe 3.0 x16 slot (slot 4) 4. PCIe 2.0 x1 slot (slot 3) 5. PCIe 3.0 x16 slot (slot 2) 6. PCIe x16 slot (PCIe 3.0 wired as x8) (slot 1) 7. DIMM slots 8. intrusion-switch connector 9. CPU heatsink fan connector 10. processor socket 11. DIMM slots 12. front-panel audio connector 13. internal USB 2.0 connector 14. coin-cell battery 15. optional hard-drive fan connector 16. system-fan connector 17. HDD temperature sensor connector 18. system-fan connector 19. PWR_REMOTE connector (for Teradici 20. thunderbolt sideband connector Host 21. Card) system-fan connector 22. password jumper 23. front panel and USB 2.0 connector 24. internal speaker connector 25. USB 3.0 front-panel connector 26. internal USB 2.0 connector for flexbay 27. SATA Connectors (HDD0-HDD3 & SATA0-1) 28. RTC_RST Jumper 29. 24-pin system power connector 30. CPU power connector
Where Used: 65120593, 65120594, 651206 Page 4 of 74 3. Overview of ESIS ESIS can be set up only on a local hard drive, a portable USB hard drive, or a removable USB drive. Setting up ESIS incudes installing Operating System (OS) and Experion software on a shared folder (the shared folder is created on a hard drive or USB drive) which can be accessed over a network to perform Experion installation on one or more systems. ESIS provides a single repository for OS and Experion software on multiple systems simultaneously. ESIS can be updated for any media updates or new media releases. 3.1. Setting up an ESIS repository If you want to use the ESIS to perform installation/migration, you must set up an ESIS repository. The ESIS is a file server/file share. It is an accessible Windows node with account security, capable of hosting a share that has available disk space to host the Experion installation media. You can set up an ESIS to host the Experion software. The ESIS can be accessed using a network share, USB drive, or a removable hard drive for installation/migration of system software on Experion system nodes. If you use ESIS, you do not have to insert the software medias into the Experion node to install the system software. ESIS repository consists of the following media: Experion PKS System Installation DVD Experion PKS System Installation Updates DVD Windows 10 Enterprise OS reinstallation DVD Windows 2016 OS reinstallation DVD Experion Installation DVD 1 Experion Installation DVD 2 SQL Server 2014 DVD Experion Support and Maintenance DVD Experion PDF Collection DVD Experion Updates DVD Prerequisites On the ESIS node, you must disable McAfee On-Access Scan for your virus protection software before setting up or updating ESIS. The network link speed on the node where ESIS is being set up, must match the link speed on the switch to which the node is connected (Link speed is 1 Mbps Full Duplex for an FTE-based network). Attention DO NOT install/setup ESIS on Experion nodes. You can create an ESIS repository on a local hard disk that can be accessed using a network share. For setting up an ESIS repository, the minimum space required on the ESIS server is 33 GB. NOTE: Depending upon your preferences for ESIS setup, the minimum size required for ESIS setup varies.
Where Used: 65120593, 65120594, 651206 Page 5 of 74 You must have.net Framework 2.0 or higher version installed on your computer for creating an ESIS repository. You can create the ESIS repository on the following operating systems: - Microsoft Windows 10 Enterprise (64-bit) - Microsoft Windows Server 28 (64-bit) - Microsoft Windows Server 2016 Standard (x64) (64-bit) The ESIS and Experion Migration Storage Node (EMSN) can be hosted on the same server. When hosted on the same node, while connecting to EMSN or ESIS, ensure to use the same account (with same permission) during migration. To set up an ESIS repository 1. Insert Experion Installation DVD 1. The Honeywell Experion PKS Installer screen is displayed. Attention If auto run is disabled on a system and Honeywell Experion PKS Installer screen does not appear, perform the following steps: 1. Using the Windows Explorer, browse to the cdbrowse path (X:\Browser), 2. Double-click cdbrowse.exe. 2. Click Setup an Experion Software Installation Server.
Where Used: 65120593, 65120594, 651206 Page 6 of 74 Attention If the ESIS tool fails to start and an error message Net 2.0 or higher needs to be installed is displayed. Administrator with CoreAdmin privileges in Terminal Manager can access the Standard Workflow Configuration Tool. Click OK to exit Navigate to <Install Media>\Packages\Microsoft\DotNet3.5\dotnetfx35.exe, and install.net framework 3.5 Or Add.Net 2.0 by starting Experion PKS System Initializationmedia\Packages\Software\Net_Framework\2. 0\Dotnetfx.exe..
Where Used: 65120593, 65120594, 651206 The Welcome to ESIS page is displayed. Page 7 of 74 The options in the Welcome to ESIS page are as follows: Create a new ESIS repository Upgrade existing ESIS repository Resume a failed ESIS repository creation Remove an existing ESIS repository Attention When the ESIS Preparation Utility is started on the node for the first time, only the option Create a New ESIS Repository is selected by default and all the other options are unavailable. 3. Select Create a New ESIS Repository if not already selected and click Next. The Select a path dialog box is displayed.
Where Used: 65120593, 65120594, 651206 Page 8 of 74 4. Click Browse to select the destination folder for the ESIS repository. Attention The destination folder must be located only on USB drives, removable hard drives, or local system drives. If you select local system drive, a message prompting to share the destination location is displayed. Perform the following steps: 1. Click OK. 2. In the <Folder Name> Properties dialog box, select Sharing.
Where Used: 65120593, 65120594, 651206 Page 9 of 74 3. Select Share this folder. 4. Enter the Share name. 5. Click Permissions to assign the share permissions. NOTE: Read permission is required for ESIS share. 6. Click OK. 5. Click Next. 6. The Select media page is displayed. Select the check boxes next to the name of the media you want to select for ESIS repository creation. NOTE: Apart from mandatory media select Experion PDF Collection DVD, and OS DVDs.
Where Used: 65120593, 65120594, 651206 Page 10 of 74 7. Click Start. The following dialogue box appears: 8. Click Ok.
Where Used: 65120593, 65120594, 651206 The Status Display page is displayed. Page 11 of 74 The selected media is displayed on the left pane of the Status Display page. The Current step displays the progress of the current media being copied. The Overall Progress displays the progress of all the media being copied. The Description displays a message related to the current media being copied. 9. When one media is successfully copied, the dialogue box appears to change the DVD. 10. Insert the DVDs as per the system instructions. This will be repeated on completion of all medias. 11. Click Ok.
Where Used: 65120593, 65120594, 651206 Page 12 of 74 12. After all the selected media are successfully copied, the Description is updated as ESIS Repository [<Name>] created successfully at <Destination Location>. 13. Click Finish. Attention Ensure that you enable On Access Scan for your antivirus after you have completed the ESIS setup.. 14. Click on Close to exit the Honeywell - Experion PKS Installer R5.
Where Used: 65120593, 65120594, 651206 Page 13 of 74 3.2. ESIS folder mapping The following table provides the naming information of ESIS folder mapping. System Installation Medias Experion PKS Installation DVD 1 Experion PKS Installation DVD 2 Experion PKS Support Software DVD Microsoft SQL Server 2014 Standard DVD Experion Support and Maintenance (ESM) DVD Experion PKS System Initialization DVD Release R2.1 (or Later*) Experion PKS System Initialization Updates DVD Release R2.1 (or Later*) Experion PKS PDF Collection Microsoft Windows 10 Enterprise 64-bit HPS OS reinstallation media Microsoft Windows Server 2016 R2 Standard 64-bit (x64) HPS Reinstallation DVD ESIS folder mapping D_EID1 D_EID2 D_SUP D_SQL D_ESM D_EXP D_EXP_UPD D_PDF D_WIN10 D_WIN2016 * Check QCS Compatibility Matrix for the latest version of Initialization Medias. NOTE: For more information about ESIS creation and setup, refer to the Software_Installation_Users_Guide_EPDOC-X136-en-5.
Where Used: 65120593, 65120594, 651206 Page 14 of 74 4. Installing the Operating System for Desktop Server or Operator Station You must perform the following tasks to create the QCS Workstation platform for RAE R70x.x systems. 4.1. Desktop Server Checklist Task See Section Completed? Install the add on Broadcom Dual Port NIC Hardware (Optional) 5 Enable the Embedded NIC (Optional) 6 Experion PKS System Installation 7 Generation of Configuration Files 7.1 Generating the Configuration Files for Desktop Server 7.1.1 Installing the Desktop Server 7.2 Monitor Connection settings 8 Set the display Properties 9 Installing the RAE 10 4.2. QCS Operator Station Checklist Table 2 Desktop Server configuration steps Task See Section Completed? Install the add on Broadcom Dual Port NIC Hardware (Optional) Enable the Embedded NIC (Optional) 6 Experion PKS System Installation 7 Generation of Configuration Files 7.1 Generating the Configuration Files for QCS Operator station 7.1.2 Installing the QCS Operator Station 7.3 Monitor Connection settings 8 Set the display Properties 9 Installing the RAE 10 Table 3 QCS Operator station configuration steps 4.3. Windows Operating System only Checklist Task See Section Completed? Install the add on Broadcom Dual Port NIC Hardware (Optional) 5 5 Enable the Embedded NIC (Optional) 6 Experion PKS System Installation 7
Where Used: 65120593, 65120594, 651206 Page 15 of 74 Task See Section Completed? Generation of Configuration Files 7.1 Generating the Configuration Files for Windows Operating System only 7.1.3 Installing the Windows Operating System only 7.4 Monitor Connection settings 8 Set the display Properties 9 Installing the RAE 10 Table 4 Windows Operating System only configuration steps 5. Install the add on Broadcom Dual Port NIC Hardware (Optional) To install the add on Broadcom Dual Port NIC Hardware, perform the following steps. 1. Open the Chassis. 2. Install the add on Broadcom Dual Port NIC (65431381) card in the PCIe X 1 slot 3. 6. Enable the Embedded NIC (Optional) By Default, the Integrated NIC card will be disabled. To enable Embedded NIC, perform the following steps. 1. Start the computer. 2. Press F2 as the computer boots to enter the System Setup. The Dell Inc. Precision Workstation T5810 dialog box for BIOS settings appears. 3. Expand and select System Configuration > Integrated NIC.
Where Used: 65120593, 65120594, 651206 Page 16 of 74 The Integrated NIC information is displayed in the right pane. 4. Under Integrated NIC, select Enabled. 5. Click Apply. 6. Click Exit 7. Experion PKS System Installation CAUTION: Users must use Experion PKS System Initialization R2.1 (or Later)* media along with HPS Operating System Reinstallation media to install Windows 10 Enterprise (64bit) operating system on the Honeywell qualified Dell Precision T5810 (RAID) Workstation (13G MLK) machines. For detailed information on above media refer to the latest Experion PKS System Initialization Media Software Change Notice. * Check QCS Compatibility Matrix for the latest version of Initialization Medias. 7.1. Generation of Configuration Files Prerequisites The ESIS section (Section 3) must be completed before generation of configuration files. You need another Windows computer with a CD/DVD ROM (Microsoft Windows 10 (64- bit) or Microsoft Windows Server 28 (64-bit) or Microsoft Windows Server 2016 Standard (x64) (64 bit)) to generate the configuration files for the target machine. The configuration files must be saved to a USB flash drive or on any removable disk. You will need to use these configuration files along with Experion PKS System Initialization media to install the Operating System With/Without Product Install on the target computer. To generate the configuration files for the target machine, perform the following steps. NOTE: Acknowledge the user account control dialog box, if it appears. It is not necessary or mandatory for the user account control dialog box to appear during the installation process. This information is applicable for the entire manual, unless explicitly stated otherwise.
Where Used: 65120593, 65120594, 651206 Page 17 of 74 1. Browse to ESIS repository and navigate to Setup.exe. 2. Right click on Setup.exe and click Run as administrator. 3. If the User Account Control dialog box appears with a message, then Click Yes. The Welcome To ESIS Tool dialog box appears. 4. Select OS preparation with/without Product Install. 5. Click Next. The Experion PKS System Initialization Wizard appears.
Where Used: 65120593, 65120594, 651206 Page 18 of 74 6. Select Generate Configuration files. 7. Click Next. NOTE: If the configuration files are already generated for the target machine, select Modify existing configuration files. Click Browse to browse to the configuration files and select the InitMediaOptions.xml file. Click Next. The subsequent dialog boxes are displayed according to the selections made as per the configuration files. You can modify the selections if required. To generate the configuration files for the Desktop machine, Operator station and Operating system only refer the below table. Scenarios Generating the Configuration Files for Target Machine as Desktop Server Generating the Configuration Files for QCS Operator station Generating the Configuration Files for Windows Operating System Sections to follow 7.1.1 7.1.2 7.1.3
Where Used: 65120593, 65120594, 651206 Page 19 of 74 7.1.1. Generating the Configuration Files for Desktop Server To generate the configuration files for target machine as desktop server using Experion PKS System Initialization Media, perform the following steps. 1. Select Generate Configuration files from Experion PKS System Initialization Wizard and click Next. 2. The Platform Configuration dialog box appears. 3. Select the following in Platform Configuration: From Choose Configuration, select Reinstall OS and Configure System in Platform Configuration. Check the Product Installation box. From Product Installation, select R5.1 from the drop-down list. From Select Platform, select Workstation and select the Precision T5810 for the target machine from the drop-down list. From Select Operating System, select Client and choose the Windows 10 (X64) from drop-down list. Click Next. The Operating System Configuration dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 20 of 74 4. Select the following in the System Settings: Select the English (United States) from the drop-down list. Select the Time Zone from the drop-down list appropriate to the geographical location where the system is used. Enter the Computer Name.
Where Used: 65120593, 65120594, 651206 Page 21 of 74 Naming restrictions The computer name must be 15 characters or less in length and with an alphabetic and numeric character ( a to z or A to Z or 0-9 ) and cannot contain spaces or other non-standard characters. The QCS workstation computer name must not end with letters A or B. Enter the Company Name. Enter the Customer Name. NOTE: For the Company Name and Customer Name do not use special characters. Enter the Workgroup Name. 5. In the Security Password Details: In the Security Password and Confirm Security Password boxes, type the password. 6. In the Account box, type User Account Name (QCSAdmin). In the Password and Confirm Password boxes, type the password. NOTE: Ensure to create a strong and unique password. Following are the criteria for ensuring a strong password. Must not contain the user s account name or parts of the user s full name that exceed two consecutive characters. Must be minimum of 6 characters and maximum 32 characters in length. Must begin with an alphabet and the must be in uppercase. Must contain characters from three of the following four categories. English uppercase characters (A through Z). English lowercase characters (a through z). Base 10 digits (0 through 9). Non-alphabetical characters (- @ # $ % ^ & + = ' ~! * ( ) _ + = { }\\ : ; \ " < >,.? /). Space is also a non-alphabetical character. The Security Password shall be used to protect the secured data (Example: Windows User Accounts password) during the installation and will be discarded after completing the installation.(security password must be 6-20 Characters) 7. Click Next. The Network and Input/output Device Information dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 22 of 74 NOTE: For the systems with FTE connections ensure to install Broadcom Dual Port Network adapter. 8. For configuring the systems with FTE, proceed with Step 10. 9. For configuring the system with Ethernet, select the Network Type as Ethernet, select the No. of Adapters as One from the drop-down list and Network Link Speed as 1 mbps Full Duplex. The configuration of a network port can be changed by selecting it and clicking the TCP/IP Properties for NIC button. The IPAddress dialog box appears and enter the required details. Click Ok. Skip to Step 12. 10. In the Network Configuration, select the following: Select the Network Type as FTE for systems with FTE Select No. of Adapters as Two for systems with FTE The configuration of a network port can be changed by selecting it and clicking the TCP/IP Properties for NIC button. 11. In the FTE Configuration: Type the Multicast Address Type the Device Index Type the UDP Source Port Type UDP Destination Port Provide a Friendly Name.
Where Used: 65120593, 65120594, 651206 Page 23 of 74 NOTE: For detailed information about FTE installation and configuration refer to Fault Tolerant Ethernet Installation and Service Guide - EPDOC-XX36-en-5A 12. In the I/O details, ensure the following settings are selected: Single monitor option. 1280x1024 resolution option. 13. Click Next. 14. Read through the Confirmation Configuration Summary details. 15. Click Generate Product Install Config. Files. The Welcome to the Honeywell Experion PKS R5.1 Installation Setup dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 24 of 74 16. Click Next. The license Agreement dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 25 of 74 17. Select I accept the terms in the License agreement. 18. Click Next. The Setup type of Node to install dialog box appears. 19. Select Server (ESV). 20. Click Next. The User and License Information dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 26 of 74 21. In the Customer Information section, enter the Name and Company Name. 22. In the Experion System Software section, click Browse to import the License file. 23. Click Next. The Machine name information message box appears. 24. Click Yes. The Installation Path(s) Selection dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 27 of 74 25. Click Next. The default installation paths must be used. The RAE software does not support Custom Install Paths (CIP). The Experion Network Selection dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 28 of 74 26. Choose a Network type and click Next. If you are selecting FTE as the Network type, then the FTE Boot and NTP IP Address Configuration dialog box appears. Enter the appropriate information in the displayed fields for Base IP Address, Subnet Mask, Default Gateway, NTP First IP Address and NTP Second IP Address. If you are selecting Ethernet, the EthNet_Sim and NTP IP Address Configuration dialog box appears. Enter the appropriate information in the displayed fields for Base IP Address, Subnet Mask, Default Gateway, NTP First IP Address and NTP Second IP Address. 27. Click Next. The Information message box appears to confirm the network selection made.
Where Used: 65120593, 65120594, 651206 Page 29 of 74 28. Click Yes. The Feature and Options Selection dialog box appears. 29. Click Custom. 30. Uncheck HMIWeb Solution Pack Runtime. 31. Check EMDB Server, Experion PKS System Document and Experion PKS SCN, Installation,. 32. Click Next. The Experion Accounts Password Entry dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 30 of 74 33. Type a strong password for all the accounts created during installation. For each of the applicable account, in the Password and Confirm Password boxes, type the password. NOTE: Password for the accounts must adhere to the following rules. Must not contain the user s account name or parts of the user s full name that exceed two consecutive characters. Must be minimum of 6 characters and maximum 32 characters in length. Must contain characters from three of the following four categories. English uppercase characters (A through Z). English lowercase characters (a through z). Base 10 digits (0 through 9). Non-alphabetical characters (- @ # $ % ^ & + = ' ~! * ( ) _ + = { }\\ : ; \ " < >,.? /). Space is also a non-alphabetical character. Type the confirmation password for each applicable account. 34. Click Next. The Experion Accounts Password Entry dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 31 of 74 35. Type a password for all the accounts created during installation. For each of the applicable account, in the Password and Confirm Password boxes, type the password. 36. Click Next. The Summary dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 32 of 74 37. Click Continue. The Confirmation summary dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 33 of 74 38. Click Save Config. Files. 39. Save the Configuration files to a USB flash drive. Click OK. The Experion PKS System Initialization dialog box appears indicating that Configuration files are saved successfully. 40. Click OK. 41. Click Finish on Confirmation summary dialog box. The Honeywell Experion System Initialization Dialog Manager dialog box appears. 42. Read the instructions on the Honeywell Experion PKS System Initialization R2.1 DialogManager. 43. Click OK. 44. Close the Honeywell- Experion PKS System Initialization window.
Where Used: 65120593, 65120594, 651206 Page 34 of 74 7.1.2. Generating the Configuration Files for QCS Operator station To generate the configuration files for target machine as QCS Operator station using Experion PKS System Initialization Media, perform the following steps. 1. Select Generate Configuration files from Experion PKS System Initialization Wizard and click Next. 2. The Platform Configuration dialog box appears. 3. Select the following in Platform Configuration: From Choose Configuration, select Reinstall OS and Configure System in Platform Configuration. Check the Product Installation box. From Product Installation, select R5.1 from the drop-down list. From Select Platform, select Workstation and select the Precision T5810 for the target machine from the drop-down list. From Select Operating System, select Client and choose the Windows 10 (X64) from drop-down list. Click Next. The Operating System Configuration dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 35 of 74 4. Select the following in the System Settings: Select the English (United States) from the drop-down list. Select the Time Zone from the drop-down list appropriate to the geographical location where the system is used. Enter the Computer Name. Naming restrictions The computer name must be 15 characters or less in length and with an alphabetic and numeric character ( a to z or A to Z or 0-9 ) and cannot contain spaces or other non-standard characters. The QCS workstation computer name must not end with letters A or B. Enter the Company Name. Enter the Customer Name. NOTE: For the Company Name and Customer Name do not use special characters. Enter the Workgroup Name. 5. In the Security Password Details: In the Security Password and Confirm Security Password boxes, type the password. 6. In the Account box, type User Account Name (QCSAdmin). In the Password and Confirm Password boxes, type the password.
Where Used: 65120593, 65120594, 651206 Page 36 of 74 NOTE: Ensure to create a strong and unique password. Following are the criteria for ensuring a strong password. Must not contain the user s account name or parts of the user s full name that exceed two consecutive characters. Must be minimum of 6 characters and maximum 32 characters in length. Must begin with an alphabet and the must be in uppercase. Must contain characters from three of the following four categories. English uppercase characters (A through Z). English lowercase characters (a through z). Base 10 digits (0 through 9). Non-alphabetical characters (- @ # $ % ^ & + = ' ~! * ( ) _ + = { }\\ : ; \ " < >,.? /). Space is also a non-alphabetical character. The Security Password shall be used to protect the secured data (Example: Windows User Accounts password) during the installation and will be discarded after completing the installation. (Security password must be 6-20 Characters). 7. Click Next. The Network and Input/output Device Information dialog box appears. NOTE: For the systems with FTE connections ensure to install Broadcom Dual Port Network adapter.
Where Used: 65120593, 65120594, 651206 Page 37 of 74 8. For configuring the systems with FTE, proceed with Step 10. 9. For configuring the system with Ethernet, select the Network Type as Ethernet, select the No. of Adapters as One from the drop-down list and Network Link Speed as 1 mbps Full Duplex. The configuration of a network port can be changed by selecting it and clicking the TCP/IP Properties for NIC button. The IPAddress dialog box appears and enter the required details. Click Ok. Skip to Step12. 10. In the Network Configuration, select the following: Select the Network Type as FTE for systems with FTE Select No. of Adapters as Two for systems with FTE The configuration of a network port can be changed by selecting it and clicking the TCP/IP Properties for NIC button. 11. In the FTE Configuration: Type the Multicast Address Type the Device Index Type the UDP Source Port Type UDP Destination Port Provide a Friendly Name.
Where Used: 65120593, 65120594, 651206 Page 38 of 74 NOTE: For detailed information about FTE installation and configuration refer to Fault Tolerant Ethernet Installation and Service Guide - EPDOC-XX36-en-5A 12. In the I/O details, ensure the following settings are selected: Single monitor option. 1280x1024 resolution option. 13. Click Next. 14. Read through the Confirmation Configuration Summary details. 15. Click Generate Product Install Config. Files. The Welcome to the Honeywell Experion PKS R5.1 Installation Setup dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 39 of 74 16. Click Next. The license Agreement dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 40 of 74 17. Select I accept the terms in the License agreement. 18. Click Next. The Setup type of Node to install dialog box appears. 19. Select Flex Station (ES-F). 20. Click Next. The User and License Information dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 41 of 74 21. In the Customer Information section, enter the Name and Company Name. 22. Select Do Not Install Software under Do you want to Install Licensed feature? 23. Select No under Are there licensed TPS Components to install? 24. Click Next. The Installation Path(s) Selection dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 42 of 74 25. Click Next. The default installation paths must be used. The RAE software does not support Custom Install Paths (CIP). The Experion Network Selection dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 43 of 74 26. Select Network for communicating between Experion Nodes (Server Client or Supervisory) as Ethernet. 27. Click Next. The Feature and Options Selection dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 44 of 74 28. Click Custom. 29. Uncheck Signon Manager and HMIWeb Solution Pack Runtime. NOTE: For Operator Station, the following features are optional Experion PKS System Document Experion PKS SCN, Installation,. 30. Click Next. The Experion Accounts Password Entry dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 45 of 74 31. Type a strong password for all the accounts created during installation. For each of the applicable account, in the Password and Confirm Password boxes, type the password. NOTE: Password for the accounts must adhere to the following rules. Must not contain the user s account name or parts of the user s full name that exceed two consecutive characters. Must be minimum of 6 characters and maximum 32 characters in length. Must contain characters from three of the following four categories. English uppercase characters (A through Z). English lowercase characters (a through z). Base 10 digits (0 through 9). 32. Click Next. The Summary dialog box appears. Non-alphabetical characters (- @ # $ % ^ & + = ' ~! * ( ) _ + = { }\\ : ; \ " < >,.? /). Space is also a non-alphabetical character. Type the confirmation password for each applicable account.
Where Used: 65120593, 65120594, 651206 Page 46 of 74 33. Click Continue. The Confirmation summary dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 47 of 74 34. Click Save Config. Files. 35. Save the Configuration files to a USB flash drive. Click OK. The Experion PKS System Initialization dialog box appears indicating that Configuration files are saved successfully. 36. Click OK. 37. Click Finish on Confirmation summary dialog box. The Honeywell Experion System Initialization Dialog Manager dialog box appears. 38. Read the instructions on the Honeywell Experion PKS System Initialization R2.1 DialogManager. 39. Click OK. Close the Honeywell- Experion PKS System Initialization window.
Where Used: 65120593, 65120594, 651206 Page 48 of 74 7.1.3. Generating the Configuration Files for Windows Operating System only The below procedure is for operating systems such as VMware vsphere Client and VMware Workstation. To generate the configuration files for target machine as Windows Operating System only using Experion PKS System Initialization Media, perform the following steps. 1. Select Generate Configuration files from Experion PKS System Initialization Wizard and click Next. 2. The Platform Configuration dialog box appears. 3. Select the following in Platform Configuration: From Choose Configuration, select Reinstall OS and Configure System in Platform Configuration. Uncheck Product Installation. NOTE: This check box must be unchecked since the OS Installation needs to be completed before installing the product software. From Select Platform, select Workstation and select the Precision T5810 for the target machine from the drop-down list. From Select Operating System, select Client and choose the Windows 10 (X64) from drop-down list. Click Next. The Operating System Configuration dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 49 of 74 4. Select the following in the System Settings: Select the English (United States) from the drop-down list. Select the Time Zone from the drop-down list appropriate to the geographical location where the system is used. Enter the Computer Name. Naming restrictions The computer name must be 15 characters or less in length and with an alphabetic and numeric character ( a to z or A to Z or 0-9 ) and cannot contain spaces or other non-standard characters. The QCS workstation computer name must not end with letters A or B. Enter the Company Name. Enter the Customer Name. NOTE: For the Company Name and Customer Name do not use special characters. Enter the Workgroup Name. 5. In the Security Password Details: In the Security Password and Confirm Security Password boxes, type the password. 6. In the Account box, type User Account Name (QCSAdmin). In the Password and Confirm Password boxes, type the password.
Where Used: 65120593, 65120594, 651206 Page 50 of 74 NOTE: Ensure to create a strong and unique password. Following are the criteria for ensuring a strong password. Must not contain the user s account name or parts of the user s full name that exceed two consecutive characters. Must be minimum of 6 characters and maximum 32 characters in length. Must begin with an alphabet and the must be in uppercase. Must contain characters from three of the following four categories. English uppercase characters (A through Z). English lowercase characters (a through z). Base 10 digits (0 through 9). Non-alphabetical characters (- @ # $ % ^ & + = ' ~! * ( ) _ + = { }\\ : ; \ " < >,.? /). Space is also a non-alphabetical character. The Security Password shall be used to protect the secured data (Example: Windows User Accounts password) during the installation and will be discarded after completing the installation.(security password must be 6-20 Characters). 7. Click Next. The Network and Input/output Device Information dialog box appears. NOTE: For the systems with FTE connections ensure to install Broadcom Dual Port Network adapter.
Where Used: 65120593, 65120594, 651206 Page 51 of 74 8. For configuring the systems with FTE, proceed with Step 10. 9. For configuring the system with Ethernet, select the Network Type as Ethernet, select the No. of Adapters as One from the drop-down list and Network Link Speed as 1 mbps Full Duplex. The configuration of a network port can be changed by selecting it and clicking the TCP/IP Properties for NIC button. The IPAddress dialog box appears and enter the required details. Click Ok. Skip to Step 12. 10. In the Network Configuration, select the following: Select the Network Type as FTE for systems with FTE Select No. of Adapters as Two for systems with FTE The configuration of a network port can be changed by selecting it and clicking the TCP/IP Properties for NIC button. 11. In the FTE Configuration: Type the Multicast Address Type the Device Index Type the UDP Source Port Type UDP Destination Port Provide a Friendly Name.
Where Used: 65120593, 65120594, 651206 Page 52 of 74 NOTE: For detailed information about FTE installation and configuration refer to Fault Tolerant Ethernet Installation and Service Guide - EPDOC-XX36-en-5A 12. In the I/O details, ensure the following settings are selected: Single monitor option. 1280x1024 resolution option. 13. Click Next. 14. Read through the Confirmation Configuration Summary details. 15. Click Save Config. Files. 16. Save the Configuration files to a USB flash drive. Click OK. The Experion PKS System Initialization dialog box appears indicating that Configuration files are saved successfully. 17. Click OK.
Where Used: 65120593, 65120594, 651206 Page 53 of 74 18. Click Finish on Confirmation summary dialog box. The Honeywell Experion System Initialization Dialog Manager dialog box appears. 19. Read the instructions on the Honeywell Experion PKS System Initialization R2.1 DialogManager. 20. Click OK. 21. Close the Honeywell- Experion PKS System Initialization window.
Where Used: 65120593, 65120594, 651206 Page 54 of 74 7.2. Installing the Desktop Server To install the desktop server machine on the target machine using Experion PKS System Initialization Media, perform the following steps. 1. Insert the Experion PKS System Initialization R2.1 (or Later*) media, connect the USB flash drive that has the configuration files (created for the target machine in Section 7.1) and connect the network share, USB drive, or a removable hard drive and the re-start the computer. * Check QCS Compatibility Matrix for the latest version of Initialization Medias. Attention Ensure that you connect USB drive to back panel USB port of the machine as the front panel USB port of the machine is disabled. 2. Watch the monitor while it restarts and press any key when you see the message Press any key to boot from CD or DVD. The Windows is loading files message appears. The Experion PKS System Initialization Pre-Install Utility window appears. 3. Click Browse and select the path where the configuration files are saved. 4. Select InitMediaOptions.xml files.
Where Used: 65120593, 65120594, 651206 Page 55 of 74 5. Click Open. 6. Click Next. The Experion PKS System Initialization Pre-Install Utility dialog box appears. 7. In the Configuration details, select the following: Partitions count as Two from the drop-down list. Type the size of Primary partition as 150 GB. 8. Type the security password details in the Security Password box.
Where Used: 65120593, 65120594, 651206 Page 56 of 74 9. Select appropriate location for installation media. - If you select ESIS from Network as appropriate location, continue with Step 10. - If you select ESIS from USB drive as appropriate location, Continue with Step 11. 10. In the Information for connecting to ESIS share: - Browse and give the ESIS path. - Enter the User name. - Enter the Password. 11. Under Information for connecting to ESIS share, Browse and give ESIS path. 12. Click Next. The Honeywell License Agreement dialog box appears 13. Select I accept the terms in the license agreement. 14. Click Install. A warning message appears indicating that the disk contents and partition will be deleted. 15. Click Yes to continue. 16. The Experion PKS System initialization preparing for Operating System installation dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 57 of 74 The Windows Setup dialog box appears. 17. The Installing Window dialog box displays the status of the Operating System installation 18. During Installation, your computer will restart several times. 19. After the required installations are completed, a message should appear in the Experion PKS-Status Display dialog box confirming the Experion PKS System Initialization Installation completed successfully. 20. Click Yes to restart the system. 7.3. Installing the QCS Operator Station To install the QCS operator station on the target machine using Experion PKS System Initialization Media, perform the following steps. 1. Insert the Experion PKS System Initialization R2.1 (or Later*) media, connect the USB flash drive that has the configuration files (created for the target machine in Section 7.1.2) and connect the network share, USB drive, or a removable hard drive and the re-start the computer. * Check QCS Compatibility Matrix for the latest version of Initialization Medias.
Where Used: 65120593, 65120594, 651206 Page 58 of 74 Attention Ensure that you connect USB drive to back panel USB port of the machine as the front panel USB port of the machine is disabled. 2. Watch the monitor while it restarts and press any key when you see the message Press any key to boot from CD or DVD. The Windows is loading files message appears. The Experion PKS System Initialization Pre-Install Utility window appears. 3. Click Browse and select the path where the configuration files are saved. 4. Select InitMediaOptions.xml files. 5. Click Open. 6. Click Next. The Experion PKS System Initialization Pre-Install Utility dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 59 of 74 7. In the Configuration details, select the following: Partitions count as Two from the drop-down list. Type the size of Primary partition as 150 GB. 8. Type the security password details in the Security Password box.
Where Used: 65120593, 65120594, 651206 Page 60 of 74 9. Select appropriate location for installation media. - If you select ESIS from Network as appropriate location, continue with Step 10. - If you select ESIS from USB drive as appropriate location, Continue with Step 11. 10. In the Information for connecting to ESIS share: - Browse and give the ESIS path. - Enter the User name. - Enter the Password. 11. Under Information for connecting to ESIS share, Browse and give ESIS path. 12. Click Next. The Honeywell License Agreement dialog box appears 13. Select I accept the terms in the license agreement. 14. Click Install. A warning message appears indicating that the disk contents and partition will be deleted. 15. Click Yes to continue. 16. The Experion PKS System initialization preparing for Operating System installation dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 61 of 74 The Windows Setup dialog box appears. 17. The Installing Window dialog box displays the status of the Operating System installation 18. During Installation, your computer will restart several times. 19. After the required installations are completed, a message should appear in the Experion PKS-Status Display dialog box confirming the Experion PKS System Initialization Installation completed successfully. Click Yes to restart the system. 7.4. Installing the Windows Operating System only To install the Windows Operating System on the target machine using Experion PKS System Initialization Media, perform the following steps. 1. Insert the Experion PKS System Initialization R2.1 (or Later*) media, connect the USB flash drive that has the configuration files (created for the target machine in Section 7.1.3) and connect the network share, USB drive, or a removable hard drive and the re-start the computer. * Check QCS Compatibility Matrix for the latest version of Initialization Medias.
Where Used: 65120593, 65120594, 651206 Page 62 of 74 Attention Ensure that you connect USB drive to back panel USB port of the machine as the front panel USB port of the machine is disabled. 2. Watch the monitor while it restarts and press any key when you see the message Press any key to boot from CD or DVD. The Windows is loading files message appears. The Experion PKS System Initialization Pre-Install Utility window appears. 3. Click Browse and select the path where the configuration files are saved. 4. Select InitMediaOptions.xml files. 5. Click Open. 6. Click Next. The Experion PKS System Initialization Pre-Install Utility dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 63 of 74 7. In the Configuration details, select the following: Partitions count as Two from the drop-down list. Type the size of Primary partition as 150 GB. 8. Type the security password details in the Security Password box.
Where Used: 65120593, 65120594, 651206 Page 64 of 74 9. Select appropriate location for installation media. - If you select ESIS from Network as appropriate location, continue with Step 10. - If you select ESIS from USB drive as appropriate location, Continue with Step 11. 10. In the Information for connecting to ESIS share: - Browse and give the ESIS path. - Enter the User name. - Enter the Password. 11. Under Information for connecting to ESIS share, Browse and give ESIS path. 12. Click Next. The Honeywell License Agreement dialog box appears 13. Select I accept the terms in the license agreement. 14. Click Install. A warning message appears indicating that the disk contents and partition will be deleted. 15. Click Yes to continue. 16. The Experion PKS System initialization preparing for Operating System installation dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 65 of 74 The Windows Setup dialog box appears. 17. The Installing Window dialog box displays the status of the Operating System installation 18. During Windows Installation, your computer will restart several times. 19. After the required installations are completed, a message should appear in the Experion PKS-Status Display dialog box confirming the Experion PKS System Initialization Installation completed successfully. 20. Click Ok to restart the system.
Where Used: 65120593, 65120594, 651206 Page 66 of 74 After Operating System installation completed, it need to be activated. To activate the Operating System, Connect the system to the internet and go to System properties page. Click Activate Windows and follow the onscreen directions. NOTE:
Where Used: 65120593, 65120594, 651206 Page 67 of 74 8. Monitor Connection settings The NVIDIA NVS 315 video card is capable of driving two VGA, single link DVI, Display Port or HDMI displays. Figure 2 Monitor connection settings for NVIDIA NVS315 Dual Video Card A DVI to VGA adapter converter can be used to convert the DVI signal to a VGA signal if required. CAUTION: Honeywell does not recommend you to use nvidia Quadro NVS 3 video card with nvidia NVS 315 video card. If you are using two video cards for quad display then ensure that both the video cards are same. If any one of the two nvidia Quadro NVS 3 video card used for quad display fails, then replace the failed video card with a new nvidia Quadro NVS 3 video card and not nvidia NVS 315 video card. If you cannot obtain a new nvidia Quadro NVS 3 video card for replacing the failed nvidia Quadro NVS 3 video card, then replace both the video cards for quad display with a new nvidia NVS 315 video card.
Where Used: 65120593, 65120594, 651206 Page 68 of 74 9. Set the display Properties This section provides the procedure to configure the display properties. 9.1.1. Display Properties Configuration for Single Monitor To configure the display properties for a computer using a single monitor, perform the following steps. 1. Right-click on the desktop, and then click Display Settings from the shortcut menu. The Settings dialog box appears. 2. Set Change the size of text, apps, and other items as 1% (Recommended) option. 3. Click Advanced display settings. The Customize your display dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 69 of 74 4. Under Resolution, move the Slider to set a screen resolution of 1280x1024 in drop-down list. 5. Click Apply. 6. The Display Settings message appears, prompting you to keep the display settings you have configured. 7. Click Keep Changes. 8. Click Display adapter properties under Related settings. The Generic PnP Monitor and NVIDIA NVS 315 Properties dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 70 of 74 9. Click the Monitor tab. 10. Under Screen refresh rate, select 60 Hertz. 11. Click Apply. The Display Settings message appears, prompting you to keep the display settings you have configured. 12. Click Keep changes. 13. Click OK. 14. Close the Display dialog box.
Where Used: 65120593, 65120594, 651206 Page 71 of 74 9.1.2. Display Properties Configuration for Dual Monitor When T5810 System is used with dual monitors, first configure the display settings for a single monitor, see section 9.1.1 and then configure the display settings for the second monitor. To configure the Display settings for the second monitor, perform the following steps. 1. Connect both the Monitors to the NVIDIA NVS 315 card. 2. Right-click on the desktop, and then click Display Settings from the shortcut menu. The Settings dialog box appears. 3. Set Change the size of text, apps, and other items as 1% (Recommended) option. 4. Click Advanced display settings. The Customize your display dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 72 of 74 5. Under Resolution, move the Slider to set a screen resolution of 1280x1024 in drop-down list. 6. Click Apply. 7. The Display Settings message appears, prompting you to keep the display settings you have configured. 8. Click Keep Changes. 9. Click Display adapter properties under Related settings. The Generic PnP Monitor and NVIDIA NVS 315 Properties dialog box appears.
Where Used: 65120593, 65120594, 651206 Page 73 of 74 10. Click the Monitor tab. 11. Under Screen refresh rate, select 60 Hertz. 12. Click Apply. The Display Settings message appears, prompting you to keep the display settings you have configured. 13. Click Keep changes. 14. Click OK. 15. Close the Display dialog box.
Where Used: 65120593, 65120594, 651206 Page 74 of 74 10. Installing the RAE To install RAE R70x.x on this workstation, refer to the manual: Real-Time Application Environment (RAE) R7.1 with Experion R5.1 Release and Installation Notes p/n 65120594.