mbc082 Bus Converter

Similar documents
mtc002 Thermocouple Converter

ASTAT XB/XBm Remote Operator

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Copyright: December 2017 Nidec Issue: E

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

How to set-up and read MOBBUS

MRUC-20 Modul-R CAN Bus Network

RS485 MODBUS Module 8I8O

RS 485 Mini Modbus 1AO

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

mtc002 Thermocouple & Digital Sensor Grain Cable Converter

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

VersaMax IP Input Module

IntesisBox Modbus Server Panasonic

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

RS485 MODBUS Module 8AO

RS485 MODBUS Module 8I8RO

1. Introduction. 2. Installation MODBUS INTERFACE

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

RS485 MODBUS Module 6RO

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

RS485 MODBUS Module 16I-M

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

1. FEATURES AND BENEFITS

H704-42(H)(E), H704-42/1(H)(E)

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Wireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

TRANSDUCER T4311, T4411

Gateway 1400 Reference Manual

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

SIOX Four I/O Mini Module

RTD-W Installation Instructions

Copyright: December 2017 Nidec Issue: E

Installation and Programming Manual

PRELIMINARY MANUAL. DC8-50-V3 Current measurement system

PAC BI-DP BIM and 8701-CA-BI Carrier

Measurement Systems Datascan Installation and User Guide

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

T2314, T2414. Instruction Manual

A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Installation & Operation Guide

GFK-2415A March Type of sensor connection

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

G3 Series PROFIBUS DP Technical Manual

HRM-0800 Instruction Manual

IFC 100 Supplementary instructions

NetBiter I/O Extender User Manual

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

Flex Series User Guide

COOLMAX SR MAXIMIZER WALLMOUNT

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone.

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

EGW1-IA3-MB User s Manual

RS-FS-N01 Wind speed transmitter user's Guide (485type)

8520/8520R. User Manual

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Ocean Controls KTA-224 Modbus IO Module

Operation manual. HDOM-Profibus-V0. More options please visit;

11 Serial Communications

LAUREL ELECTRONICS, INC.

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS

VPGate Manual PROFIBUS to serial

Installation Instructions

LPG STM 94442A User s Manual

EL731 PROFIBUS INTERFACE

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

T2314, T2414. Instruction Manual

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

- NLS NAVIGATION LIGHT CONTROL

Ethernet/SIOX Gateway Applicable to firmware ver 1.0

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Powered Roller Controller for DeviceNet

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

P3-SCM. General Specifications

Modbus communication module for TCX2: AEX-MOD

Optional Accessories 6 2

DATA CONNECT ENTERPRISE

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

A66N2 Installation and Programming Manual

2002 Series DeviceNet Technical Manual

Momentum 171 CCC Processor with Ethernet Communication Port

Automationdirect.com. D i r e c t L o g i c M a g n e t i c P u l s e I n p u t C o p r o c e s s o r F 4-8 M P I

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

VersaMax IP I/O Module

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

Gateway BACnet IP/MS-TP slave KNX TP Code: EK-BJ1-TP-IP / EK-BJ1-TP-MSTP

Transcription:

BUS CONVERTER RS485 TO 1-WIRE BUS mbc082 mbc082 Bus Converter Document. 10910, Revision - February 2007 2007 CMC Industrial Electronics Ltd.

This page intentionally left blank.

mbc082 Bus Converter Technical Manual /i Table of Contents 1. Overview... 1 2. Description of Connectors, Operators and Indicators... 3 3. External Wiring... 5 3.1 Wiring the Sensor Bus Network... 5 3.2 Wiring the mtb006 Field Wiring Interconnects... 6 3.3 Wiring the Power and Communications Network... 6 3.4 Setting the Converter s Modbus Address... 7 4. 1-Wire Sensor Bus Operation... 10 5. Modbus RS485 RTU Communications... 12 6. Restoring Factory Default Values... 16 7. Specifications... 18 8. Troubleshooting Guide... 20 Table of Figures Figure 1 - Connectors, Operators and Indicators... 4 Figure 2 - Typical Data/Power Connections... 7 Figure 3 Address Switch Details... 8

mbc082 Bus Converter Technical Manual /ii Revision tes First Release February 15, 2007

mbc082 Bus Converter Technical Manual /iii This page intentionally left blank.

mbc082 Bus Converter Technical Manual /1 1. Overview The mbc082 Bus Converter is an industrial device mounted in a low cost plastic enclosure. The device is used to connect up to 32 1-Wire bus sensors to a Modbus 485 RTU compatible PLC or computer system. Automatic bus tuning is employed to allow a wide variation in network topology and cabling systems. The sensor bus can extend up to 300 meters (1000 feet). The sensor field bus includes a failsafe current limited sensor power supply. Communication to the host system is via an RS485 multi-drop network using Modbus RTU protocol. The device looks like a simple PLC to the host system. Sensor values and status are continuously available to the host system. Sensor network polling and maintenance are handled automatically in the background. Sensor bus fault detection and recovery are also automatic. A simple flashing lamp diagnostic is included to aid field service. This diagnostic identifies open and shorted sensor bus cables. Up to 6 sensor bus and hardware faults are annunciated. The 1-Wire sensor bus uses a unique serial number provided with each sensor for polling. The converter will automatically capture the serial numbers of sensors present on the bus and store them in ascending order. Included in the sensors serial number is also a device code. The device code tells the converter what type of sensor is present and how to process the sensors data. The sensor data is presented to the host system a single 16 bit word in 2 s complement form.

mbc082 Bus Converter Technical Manual /2 This page intentionally left blank.

mbc082 Bus Converter Technical Manual /3 2. Description of Connectors, Operators and Indicators 2 1 TB1 TB2 3 S2 S2 Bottom of circuit assembly shown with cover removed

mbc082 Bus Converter Technical Manual /4 ID Label Description Figure 1 - Connectors, Operators and Indicators TB1 RS485 Network and Supervisory Power Terminals TB2 RS485 Network and Supervisory Power Terminals 1 Communications lamp (green) 2 Status lamp (red) Communications and power connections. See drawing 10386 and 10416 in the Appendices for connection details. Communications and power connections. See drawing 10386 and 10416 in the Appendices for connection details. Flashes for each valid packet received and replied to. May light continuously, depending on the poll rate. rmal operation, flashing 1 second on / 1 second off; Diagnostics, a series of short flashes followed by 1 second off; Flashes Description 1 5VDC supply wire shorted to common wire 2 sensors detected on the bus 3 Data wire shorted to common wire 4 Data wire shorted to 5VDC wire 5 Excessive bus communications errors during an acquire serial number operation 6 Power on test hardware fault or Flash memory write fault 3 Sensor bus cable Attach the supplied 6 conductor sensor cable to this connector connector S1 Setup Press and hold during power-up to reload factory default values. S2 Address / Termination Switch ON 1 2 3 4 5 6 7 8 + + + + + + T T 32 16 8 4 2 1 Edge of enclosure To set an address turn on the switches that add up to the address required. Switch is shown set for address 1. For address 5, switches marked +1 and +4 would be turned on. The switch marked T is used to terminate the RS485 bus at the last converter on the network. Only the last device (only one communications cable connected) can have the T switches on.

POWER STATUS POWER INPUT - + V C I 1 2 0 4 X 16 X I 64 X X CMC Industrial Electronics www.cmciel.com 2 1 V mam001 Analog Input Module mts014 / 5VDC CMCIEL CANADA mts012 / 5VDC CMCIEL CANADA 16-0-8-0 31-104-108-190 16-0-8-0 31-104-108-190 STATUS CMC Industrial Electronics www.cmciel.com STATUS mts011-1/4 5VDC CMCIEL CANADA mts012 / 5VDC CMCIEL CANADA 16-0-8-0 31-104-108-190 16-0-8-0 31-104-108-190 mts014 / 5VDC CMCIEL CANADA 16-0-8-0 31-104-108-190 STATUS ROTATION mbc082 Bus Converter Technical Manual /5 3. External Wiring The sensor bus consists of CAT5 cable interconnected sing field wiring interconnects. The complete wiring system is specified. The sensors connect to the 1-Wire bus using RJ-11 connectors supplied with the sensors. moi215 mbc082 mbc081 mtb001 mcm001 CMC Industrial Electronics mts011 mcm001 AC Current Monitor 0-5A AC www.cmciel.com Internet / Intranet mam001 mts015 mtb006 mts012 mrs001 CMC Industrial Electronics mrs001 Rotation Sensor www.cmciel.com mrh001 Relative Humidity Monitor Desktop Computer mrh001 mts015 mts014 mtb005 Indoor Commercial Application mts012 Indoor / Outdoor Industrial Application Figure 1 Typical Field Wiring Detail 3.1 Wiring the Sensor Bus Network The mbc082 supports up to 32 1-Wire Bus devices. The 1-Wire Bus uses a single conductor for data communications. Included with the bus is 5VDC to power the sensors. Only CAT5 cable is permitted for the sensor bus. This cable is available in standard, plenum, direct burial and Teck90/ACIC jacket configurations. The only difference between cables is the jacket. Where the cable needs mechanical protection, we recommend direct burial cable or cables with a Teck90/ACIC jacket. Direct burial cable has a semi-rigid, tough outer jacket with good protection for most areas. Direct burial cable should be purchased with the available integral aluminum shield. Superior Essex Type BBDN, Part. 04-001-34 is an example of direct burial cable. The sensor bus allows for taps and tees in the network topology. The converter has an automatic adaptive sensor bus system that adjusts for changes in the cabling topology. This system is dynamic and requires no adjustments. Sensors can be installed anywhere on the cable. Branch lines of any length can be used, but the entire CAT5 network, including branches, must not exceed 305m or 1000.

mbc082 Bus Converter Technical Manual /6 The cabling system should also be shielded from severe electrical noise. Cable installation should prevent mechanical damage to both the main bus cable and the individual sensor cables. 3.2 Wiring the mtb006 Field Wiring Interconnects The Field Wiring Interconnect provides the transition between the CAT5 cable and the cables provided with each sensor and the mbc082 Bus Converter. Each of the field devices comes complete with 2 meters of cable and an attached RJ11 plug. The Field Wiring Interconnects have two, four or six RJ11 sockets to accept the field devices. Do not modify the cable attached to the mbc082 or the cables attached to the sensors. Connect these cables directly to the RJ11 sockets on the mtb006. The backbone of the system is CAT5 cable, which punches down to the 110 punch-down blocks on the front of the Field Wiring Interconnect. Any form of CAT5 cable including unshielded, shielded and direct burial can be used. The mtb006 Field Wiring Interconnect includes a NEMA4X plastic enclosure and all required internal mounting hardware for installation outdoors or in industrial environments. There are two or three, 110 punch-down blocks on the front of each Field Wiring Interconnect. The center block of the three block units is for the incoming cable. This is the cable that will be supplying power and data from an mbc082 or previous network branch. The one or two outgoing blocks are to continue the network. Punch the cables down using an approved 110 tool. The required cable color codes are printed next to the punch-down blocks. Use the supplied wire clamps to secure the cable if required. The shield on shielded CAT5 cable must be connected using the cable clamps or wire nuts if used. When using the mtb006 and shielded CAT5 cabling, connect the conduit ground strap to the grounding terminal in the mtb006 connected directly to the mbc082. Do not connect the grounding strap to the grounding terminal at any other mtb006. There are 2 switches and 2 indicator lights on the mtb001 and mtb006. The Branch A switch controls the network segment attached to the Network A punch-down block and Branch B switch controls the network segment attached to the Network B punch-down block. The power lamp indicates that 5 VDC control power is present. The Data lamp indicates that data packets are present on the bus. When first powering up the network, have all switches off. Add each network segment, observing the lamps. If a lamp go out, when a network segment is added, verify the wiring for that segment. This method can also be used to troubleshoot the network in the future. 3.3 Wiring the Power and Communications Network The mbc082 is equipped with 2 terminal strips for the RS485 communications network. The second terminal strip allows for the continuation of the network. Either terminal strip may be used for the incoming or outgoing cable. The RS485 network does not allow taps or tees in the cabling topology. Always bring both incoming and outgoing network cables directly to the mbc082. At the end of the cabling system the unused terminal strip is left unconnected.

mbc082 Bus Converter Technical Manual /7 24 VDC DATA + SHIELD DATA - COMMON 24 VDC DATA + SHIELD DATA - COMMON Modbus RS-485 network with 5VDC Power Wire colors shown are typical Figure 2 - Typical Data/Power Connections The communication network backbone cable should be a two pair individually shielded cable. Low capacitance twisted pair cable is recommended. The cable should be sized to ensure voltage drop on the supervisory power conductors does not exceed the input voltage specifications. The mbc082 uses efficient switching regulator technology. The input current required by the controller will increase proportionally as the input voltage is reduced. The mbc082 is a full load RS485 device allowing a maximum of 31 controllers from a single RS485 host transceiver. Do not connect more than 32 devices, including the host, to a network segment. The RS485 data signals are referenced to the 24VDC common terminal. The Data + line is the non-inverted RS485 data line and the Data - line is the inverted RS485 data line. The data lines of the mbc082 can be connected directly to an RS485 host or to an RS232 host using a suitable converter. 3.4 Setting the Converter s Modbus Address To set the converter s address turn on the switches that add up to the address required. The address switch is shown set for address 1. For address 5, switches marked +1 and +4 would be turned on. The switches marked T is used to terminate the RS485 bus at the last converter on the network. Only the last device (only one communications cable connected) can have the T switches on.

mbc082 Bus Converter Technical Manual /8 Switch Description 8 Adds 1 to address 7 Adds 2 to address 6 Adds 4 to address 5 Adds 8 to address 4 Adds 16 to address 3 Adds 32 to address 2 On to terminate network (Adds 64 to address before V1.05) 1 On to terminate network ON 1 2 3 4 5 6 7 8 + + + + + + T T 32 16 8 4 2 1 Edge of enclosure Figure 3 Address Switch Details The address switch is read during the power on sequence. Changes made to the address while the controller is running will not take effect until the next power on cycle or soft reset.

mbc082 Bus Converter Technical Manual /9 This page intentionally left blank.

mbc082 Bus Converter Technical Manual /10 4. 1-Wire Sensor Bus Operation The converter communicates with the field sensors over a 1-Wire communications bus. The bus voltage levels are 5VDC and the data bus is at 5VDC (high) when idle. The method of signaling is Master-Slave. The Master initiates communication by sending a command sequence. The slave device responds by controlling the bus during pre-defined read time slots. All slave devices are wired AND devices and can only leave the bus high, or pull it low during pre-defined time slots. Each slave device (sensor) has a unique serial number assigned by the manufacturer. Slave devices are selected by polling the bus with the slave s serial number. The serial numbers to be polled are stored in a table within the controller. Only devices specifically designed for use with the converter can be attached to the bus. A list of supported devices and sensors is included in the Appendix 1 of this manual. Polling of the sensors is automatic and continuous. The entire network of 32 sensors is polled approximately each second. Empty entries in the serial number table are skipped. The new values obtained from the sensors are placed in the sensor value table. The status of each sensor, either on of off line, is maintained in the sensor status registers. The health of the sensor data bus is reported in the converter s status register. Physical faults with the sensor bus are automatically reported. Status bits indicate the cause of sensor bus faults. Controller hardware and parameter tables faults are also indicated. The sensor bus power supply is current limited and controlled. If a short circuit is detected on the 5 VDC wire, the current is limited and then the power source is turned off. The power source will be returned in 10 seconds. If the power bus is still shorted, the cycle repeats every 10 seconds. damage will occur to either the data or power portions of the sensor bus due to shorts or open conditions. Do not apply external voltage sources of any kind to the sensor bus. The sensor serial number consists of eight, single byte (8-bit) numbers. The converter has a 32 entry table for the serial numbers. Sensors are polled from this table, starting from table entry 1. The converter stores the serial number table in flash memory. The serial numbers can be read from the table over the Modbus Network using a group of scratch pad registers. The serial number consists of: Byte Description 1 Sensor device code 2 MSB of serial number 3 Byte 5 of serial number 4 Byte 4 of serial number 5 Byte 3 of serial number 6 Byte 2 of serial number 7 LSB of serial number 8 Checksum of serial number The converter has a command register that allows operations to be controlled over the Modbus Network. One of these commands allows the setting of sensor serial number table entries from

mbc082 Bus Converter Technical Manual /11 the values stored in the scratchpad registers. See Section 5. Modbus 485 RTU Communications for details. A second command can automatically obtain the serial numbers of the sensors connected to the bus. A special sequence is initiated, which uses a high-speed algorithm to obtain the serial numbers. A third command allows the clearing of the serial number table. See Section 5. Modbus 485 RTU Communications for details on initiating the serial number search and clear commands. If the serial number table is clear when the acquire serial number command is executed, the serial numbers located will be placed in the table in ascending order. If the table contains previously located serial numbers, the controller will follow this sequence to store the new serial numbers; 1) All of the serial numbers currently attached to the sensor bus will be located and stored in a temporary table; 2) The temporary table will be verified against the existing table and any serial numbers from the existing table not found in the temporary table will be deleted from the existing table; 3) Any new serial numbers from the temporary table not founding in the existing table will be placed in the existing table in ascending order starting with the first empty space; This method of operation allows replacement sensors to be located and added to the table without disturbing the table positions of the pre-existing sensors. The serial number table may not be in true ascending order after completion of an acquire command with a previously populated sensor serial number table.

mbc082 Bus Converter Technical Manual /12 5. Modbus RS485 RTU Communications The controller communicates with a host computer or PLC over an RS-485 network using the Modbus RTU protocol. The default settings for the communications network are 19200 Baud, no parity and 1 stop bit. The memory of the controller has been configured to simulate a PLC with 45, 16 bit registers. These registers are allocated as follows: Register Typ Description 40001 R/W Sensor number Setting this register causes the serial number for the selected sensor to be loaded immediately into registers 40002 9. The sensor number is also used for the write sensor serial number command. The values in registers 40002 9 will be written to the location specified by this register upon execution of a write serial number command. The range of sensor numbers is 1 32. 40002-9 R/W Sensor serial number The values entered in these register are the sensor s serial number selected by register 40001. Each 16 bit register contains 1 byte (8 bits, right justified) of the serial number. The serial number is represented as follows: 40002 - The device code 40003 The most significant byte of the serial number 40004 Byte 5 of the serial number 40005 Byte 4 of the serial number 40006 Byte 3 of the serial number 40007 Byte 2 of the serial number 40008 The least significant byte of the serial number 40009 The checksum of the serial number The range of each serial number byte is from 0 255. If all bytes are set to 0, the entry is not polled during communications.

mbc082 Bus Converter Technical Manual /13 40010 R/W Command register The command register contains a series of bits that initiate operations within the controller. To initiate an operation, set the associated bit. The controller automatically clears the bits when the operations are initiated. A list of the bits and their functions follows: 0 Soft reset Reset the controller, equivalent to a power on reset. 1 Write serial no from scratch 2 Acquire serial numbers Write the serial number from registers 40002 9 to the table entry indicated in register 40001. Automatically acquire the sensor serial numbers for all sensors connected to the bus. If the table was cleared before performing this operation, the serial numbers will be retrieved and stored in ascending order, with the lowest order serial number in register 40014. If the sensor serial number table was already populated, sensors that existed in the table would remain in their previous locations. Sensors that were in the table, but not detected during this operation would be deleted. Any new sensors detected would be added to the blank spaces in the table in ascending order. The new table may now not be in ascending order. This method of operation allows the controller to acquire replacement sensors without disturbing the remaining sensors table positions. 3 Clear serial no s Clear the serial number table of all existing entries. The table will be filled with 0 and no sensors will be polled on the bus. 8 Channel select 0 On multi-channel sensor devices, select channel 0 for all sensors. 9 Channel select 1 On multi-channel sensor devices, select channel 1 for all sensors. 10 Channel select 2 On multi-channel sensor devices, select channel 2 for all sensors.

mbc082 Bus Converter Technical Manual /14 11 Channel select 3 On multi-channel sensor devices, select channel 3 for all sensors. 40011 R Status Register This register indicates the internal status of the converter and the sensor bus. A set bit indicates a fault. The fault assigned to each bit is as follows: 0 Bus data shorted low The data wire is shorted to the common wire. 1 Bus data shorted high The data wire is shorted to the 5VDC wire. 2 Sensors present sensors are present on the sensor bus, or the sensor bus data wire is open. 3 Bus power overload The 5VDC wire is shorted to the common wire. 4 Excessive bus errors During an acquire serial number operation, the converter detected excessive bus errors. This condition would indicate faulty sensor bus cabling, or excessive electrical interference on the sensor data bus. 8 Sensor bus fault A sensor bus fault is present as indicated by bits 0 4. 9 Sensor table overflow More than 32 sensors were detected during a sensor serial number acquire operation. 10 Unsupported Sensor detected A sensor was detected on the sensor bus that is not supported by this converter. 11 In acquire An acquire sensor serial numbers operation is in progress. 13 RAM fault The converters RAM did not pass the power on test. 14 Parameter table fault The parameter table checksum is invalid or a write to the parameter table Flash memory has failed. 15 Firmware fault The converters Flash memory firmware failed the power on CRC test.

mbc082 Bus Converter Technical Manual /15 400012-13 40014-45 R R Sensor status Each bit of these registers represents a single sensor. If the bit is set the sensor is faulted and not available. If the bit is clear is sensor is online. Bit 0 of register 400012 represents sensor 1. Bit 31 of register 40013 represents sensor 32. Sensor values Each of these registers represents a sensors raw 2 s complement value. The value is right justified, with the MSB representing the sign. Sensors that are offline have a forced value of +4095. Appendix 1 details the sensor value returned from each type of sensor. 40046 R Watchdog counter, increments every second and rolls over at 32767 40047 R Channel 0 - Software Version Channel 1 - Address switch setting

mbc082 Bus Converter Technical Manual /16 6. Restoring Factory Default Values Pressing and holding the SETUP push button during a power-up sequence will restore the factory default values. The STATUS indicator will flash at a 10 per second rate when the parameters have been reloaded. Release the button to resume normal operation. The Factory Default Values will be in effect immediately after this operation.

mbc082 Bus Converter Technical Manual /17 This page intentionally left blank.

mbc082 Bus Converter Technical Manual /18 7. Specifications Description Sensor bus Voltage Current Communications DC Power Supply Voltage Current Communication Standard Distance Input Load Termination Environment Temperature Relative Humidity Dimensions Hieght Width Depth Characteristic 5 VDC 0.125A, electronically limited 1-Wire Bus 22 to 28 VDC 80mA @ 24VDC maximum RS485 differential 500m (1640ft.) 12kΩ, standard 120Ω balanced line -40 to 70C (-40 to 158 F) 0 to 95% non-condensing 65mm (2.5in) 90mm (3.5in) 40mm (1.5in)

mbc082 Bus Converter Technical Manual /19 This page intentionally left blank.

mbc082 Bus Converter Technical Manual /20 8. Troubleshooting Guide Before attempting troubleshooting, familiarize yourself with the indicator lamps and address switch settings detailed in 2. Description of Connectors, Operators and Indicators. There are 2 basic systems operating within the mbc082. The first is the Modbus RTU RS485 communications network. This network connects multiple mbc082 s to a single Host or Master device. It is the host that polls for data from the mbc082. Before starting this guide, insure that the host is running and polling the mbc082 s. The second system is the sensor bus network. The mbc082 manages the sensor bus and continually polls for sensors in its serial number table. Before starting this guide verify that the sensor serial number table in the mbc082 s are correct. The status lamp on each mbc082 provides information as to the state of the sensor bus. The Field Wiring Interconnect status lamps and switches can be used to isolate network segments during troubleshooting. To isolate a defective cable or sensor, start at the Field Wiring Interconnect closest to the mbc082 and disable outgoing network segments using the switches. Observe the lamps on the Field Wiring Interconnect as you switch in additional segments. If a segment has a shorted cable or sensor, the lamps will go out when that segment is added. te if the power conductor is shorted, the mbc082 will turn off the 5VDC supply. Wait for at least 10 seconds to see if power is restored. Start Are any lamps flashing? Is 24VDC present on TB1 and TB2? Check network cabling and device supplying 24VDC Replace mbc082

mbc082 Bus Converter Technical Manual /21 Is the green lamp flashing or on steady? Is the host polling the mbc082's? Correct host Is the host polling the correct adresses? Correct host Are the mbc082 addresses set correctly? Set addresses and cycle the power Check bus voltage at first and last device on network Is Data + = 1.0-1.5V & Data - = 1.5-2.0V? Is the bus terminated properly? Check for termination at the host and insure terminate switch is on at the last mbc081 on network

mbc082 Bus Converter Technical Manual /22 Replace mbc081 Turn off power and break network so only the host and the first mbc081 are present. Make sure bus is terminated. Re-apply power. Is the green lamp now flashing or steady? Check cabling. Replace 1st mbc081 then host until communications is restored. Turn off power. Add next mbc081 to the network Re-apply power. Is next mbc081 now communicating? Replace the mbc081 just connected Is this the last mbc081 on the network?

mbc082 Bus Converter Technical Manual /23 Done Is the red lamp flashing at 1 sec on 1 sec off rate? Is the red light flashing 1 short flash? Sensor bus 5VDC bus wire is shorted to common wire Is the red light flashing 2 short flashes? sensors detected on the bus, data wire is open Is the red light flashing 3 short flashes? Sensor bus data wire is shorted to the common wire Is the red light flashing 4 short flashes? Data wire is shorted to the 5VDC wire

mbc082 Bus Converter Technical Manual /24 Is the red light flashing 5 short flashes? Excessive bus errors were detected during a serial number acquire operation Is the red light flashing 6 short flashes? The mbc081 hardware failed the power on test or write serial numbers to Flash memory has failed Any other lamp flashing sequence, mbc081 is defective, replace Are sensors indicating fault in the sensor status table? Is the faulted sensor's serial number entered in the serial number table? Add the sensor's serial number to the table or correct the sensor's serial number entry in the table

mbc082 Bus Converter Technical Manual /25 The sensor is defective or not connected to the sensor bus Are any sensor's value incorrect? Is the sensor bus 5VDC wire connected to the sensor? Check the 5VDC wire connected to the sensor with the incorrect value Replace the sensor Done

mbc082 Bus Converter Technical Manual /26 Appendix 1 Supported Sensors Only sensors supplied and approved by CMC Industrial are permitted. A wide variety of sensors are available. Contact the factory or our web site www.cmciel.com for a list of available sensors for this system.

mbc082 Bus Converter Technical Manual /27 This page intentionally left blank.