Advanced NI-DAQmx Programming Techniques with LabVIEW

Hands-on Lab 2: LabVIEW NI-DAQ Basics 2

LabVIEW Core 1. What You Need To Get Started. File Locations. The course installer places the course files in the following location: ni.

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

Dept. of Electrical, Computer and Biomedical Engineering. Instrumentation for the data acquisition laboratory

E Series Multifunction I/O 1.25 MS/s, 12-Bit, 16 or 64 Analog Inputs

A variety of ECONseries modules provide economical yet flexible solutions

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

VIBbox 64-Channel Sound & Vibration Solution

Low Cost Data Acquisition Setup for Electrical Machines Laboratory. Ciprian Sorandaru, Sorin Musuroi

ECONseries Low Cost USB DAQ

ECONseries Low Cost USB DAQ

What s New in Data Acquisition

Data Acquisition in LabVIEW

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

DT3016. High-Speed, Multifunction PCI Data Acquisition Board. Overview. Key Features. Supported Operating Systems

ni.com/training Quizzes LabVIEW Core 1 ni.com/training Courses Skills learned: LabVIEW environment Certifications Skills tested: LabVIEW environment

ENGR 1000, Introduction to Engineering Design

Data Acquisition Laboratory

AIO AH-PCI. Features. Packing List. 12-bits Analog I/O Board (High Gain) for PCI AIO AH-PCI 1. Ver.1.04

Vernier SensorDAQ User s Manual

USB-231-OEM. Analog and Digital I/O. User's Guide. January Rev 4 Measurement Computing Corporation

Analog Input Sample Rate

NI-DAQmx Basic Course NITS John Shannon

Data Acquisition Fundamentals

USB 1608G Series USB Multifunction Devices

USB 1608G Series USB Multifunction Devices

GEORGIA INSTITUTE OF TECHNOLOGY School of Electrical and Computer Engineering ECE 2020 Fall 2017 Lab #1: Digital Logic Module

DATENBLATT ADA16-8/2(LPCI)L. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

BE/EE189 Design and Construction of Biodevices Lecture 5. BE/EE189 Design and Construction of Biodevices - Caltech

Additional products and features

User Manual. Printed: 11/6/2013 Filename: NATUM1 - National Instruments I/O Device for V+ User Manual, V1.1 Copyright 2003, SimPhonics Incorporated

DAQ in MATLAB HANS-PETTER HALVORSEN,

Acquiring Data from Sensors and Instruments Using MATLAB

DT9828. USB Powered Thermocouple Measurement Module. Key Features: Analog Input Channels

DT Channel Analog Input USB DAQ Module. Key Features:

DT MS/s High-Speed, Isolated Simultaneous USB Data Acquisition Module. Overview. Key Features. Bandwidth of the DT9862

Developing Measurement and Control Applications with the LabVIEW FPGA Pioneer System

PHY 351/651 LABORATORY 1 Introduction to LabVIEW

Features. RoHS COMPLIANT 2002/95/EC

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.02

Datalogging in LabVIEW

1. Learn about LabView software and its different components

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.02

CHAPTER IV Computerized Data-acquisition Systems

Low Cost Multifunction I/O 100 ks/s, 12-Bit, 8 Analog Inputs

A 40-pin connector provides access to 24 DIO connections.

Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE AI-1616L-LPE 1. Ver.1.01

Features Summary. Input Ranges

Electron Paramagnetic Resonance PH425 System outline Michael Kabatek & Jessica Lovewell Version 1.1

±500 V Isolation Protects Your Data. Sample Rate. 16 bits ±1.25 V, ±2.5 V, ±5 V, ±10 V 100 ks/s 16 2

Multifunction DAQ Accessory and Cable Selection Guides

NI Technical Symposium ni.com

DT9853/DT9854 Isolated, Low Cost D/A Modules for USB

Register Map and Descriptions

Developing Measurement and Analysis System using MATLAB

PHYS 5061 Lab 6 Programmable Instruments

DATENBLATT ADA16-32/2(PCI)F. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

DT7816 Linux Data Acquisition Real-Time High Performance ARM Module for Embedded Applications

BTH-1208LS Wireless Multifunction DAQ Device

Lab Exercise 2: Data Acquisition with NI LabVIEW

Determination of Drag Coefficient

Homework Assignment 9 LabVIEW tutorial

USER GUIDE USB-634x/635x/636x OEM X Series USB-6341/6343/6356/6361/6363/6366 OEM Devices

Portable E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, 16 Analog Inputs

Computerized Measurement systems

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.01

Chapter 1 Introducing the OM-USB-1608FS-Plus... 6 Functional block diagram... 6

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.01

Low-Cost E Series Multifunction DAQ. 12 or 16-Bit, 200 ks/s, 16 Analog Inputs

Lab Exercise 4: Analog & Digital I/O Signals

High-Speed M Series Multifunction DAQ 16-Bit, up to 1.25 MS/s, up to 80 Analog Inputs

ENGR 1000, Introduction to Engineering Design

Engineering Project-I. Module 1: Familiarization of LabVIEW and the Vernier Toolkit

USB-234. Analog and Digital I/O. User's Guide. January Rev 4 Measurement Computing Corporation

Computer Hardware Requirements for Real-Time Applications

NI USB-622x/625x/628x OEM

Unlocking the Potential of Your Microcontroller

AMPLICON ADIO32. LabVIEW DRIVER SOFTWARE

NI mydaq HANS-PETTER HALVORSEN, Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics

LabVIEW FPGA in Hardware-in-the-Loop Simulation Applications

High-Speed Voltage Output up to 1 MS/s/Channel, up to 16 Bits, up to 32 Channels

High-Speed Voltage Output up to 1 MS/s/Channel, up to 16-Bit, up to 32 Channels

16-Bit A/D Converter (ENOB=14.1) 16-bit D/A. 16-bit D/A. Digital I/O (8/8) Counter/Timer (2)

USB-231. Analog and Digital I/O. User's Guide

Computer Interfacing Using LabView

Agenda. Programming FPGAs Why Are They Useful? NI FPGA Hardware Common Applications for FPGAs How to Learn More

LabVIEW Tutorials. T.1 Temperature Measurement and Cold Junction Compensation (CJC) LUMS School of Science and Engineering

M Series USB-6221/6225/6229/6251/6255/6259 OEM Devices

UM E. DT9812, DT9813, and DT9814 User s Manual

LabVIEW Basics I: Introduction Course

High-Accuracy M Series Multifunction DAQ 18-Bit, up to 625 ks/s, up to 32 Analog Inputs

DAQ Hardware Overview Guide

USB-201-OEM. Analog and Digital I/O. User's Guide

User-configurable Resolution. 9 to 12 bits (0.5 C to C)

AO-1604LX-USB. Features. High-Resolution Analog Output Unit for USB AO-1604LX-USB 1. Ver.1.01

CompactDAQ Chassis PRODUCT FLYER CONTENTS. Цены и срок поставки уточняйте на сайте по телефону: или

Step-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

LABORATORY USE OF A MICROCOMPUTER (Last Revision: August 27, 2000)

Transcription:

Data acquisition system Part (1) Digital inputs output and counter You can think of a data acquisition system as a collection of software and hardware that connects you to the physical world. A typical data acquisition system consists of these components. Components Data acquisition hardware Sensors and actuators (transducers) Signal conditioning hardware Computer Software Description At the heart of any data acquisition system lies the data acquisition hardware. The main function of this hardware is to convert analog signals to digital signals, and to convert digital signals to analog signals. Sensors and actuators can both be transducers. A transducer is a device that converts input energy of one form into output energy of another form. For example, a microphone is a sensor that converts sound energy (in the form of pressure) into electrical energy, while a loudspeaker is an actuator that converts electrical energy into sound energy. Sensor signals are often incompatible with data acquisition hardware. To overcome this incompatibility, the signal must be conditioned. For example, you might need to condition an input signal by amplifying it or by removing unwanted frequency components. Output signals might need conditioning as well. However, only input signal conditioning is discussed in this chapter. The computer provides a processor, a system clock, a bus to transfer data, and memory and disk space to store data. Data acquisition software allows you to exchange information between the computer and the hardware. For example, typical software allows you to configure the sampling rate of your board, and acquire a predefined amount of data. The data acquisition components, and their relationship to each other, are shown below.

The figure depicts the two important features of a data acquisition system: Signals are input to a sensor, conditioned, converted into bits that a computer can read, and analyzed to extract meaningful information. Data from a computer is converted into an analog signal and output to an actuator. Data Acquisition Hardware Data acquisition hardware is either internal and installed directly into an expansion slot inside your computer, or external and connected to your computer through an external cable, which is typically a USB cable. At the simplest level, data acquisition hardware is characterized by the subsystems it possesses. A subsystem is a component of your data acquisition hardware that performs a specialized task. Common subsystems include Analog input Analog output Digital input/output Counter/timer Hardware devices that consist of multiple subsystems, such as the one depicted below, are called multifunction boards.

Analog Input Subsystems Analog input subsystems convert real-world analog input signals from a sensor into bits that can be read by your computer. Perhaps the most important of all the subsystems commonly available, they are typically multichannel devices offering 12 or 16 bits of resolution. Analog input subsystems are also referred to as AI subsystems, A/D converters, or ADCs. Analog Output Subsystems Analog output subsystems convert digital data stored on your computer to a real-world analog signal. These subsystems perform the inverse conversion of analog input subsystems. Typical acquisition boards offer two output channels with 12 bits of resolution, with special hardware available to support multiple channel analog output operations. Digital Input/output Subsystems Digital input/output (DIO) subsystems are designed to input and output digital values (logic levels) to and from hardware. These values are typically handled either as single bits or lines, or as a port, which typically consists of eight lines. While most popular data acquisition cards include some digital I/O capability, it is usually limited to simple operations, and special dedicated hardware is often necessary for performing advanced digital I/O operations. Counter/Timer Subsystems Counter/timer (C/T) subsystems are used for event counting, frequency and period measurement, and pulse train generation.

Lab work: In our lab data acquisition hardware that we will use is a data acquisitions card USB-6009 from national instrument, and labview is our software. The NI USB-6008/6009 provides connection to eight analog input (AI) channels, two analog output (AO) channels, 12 digital input/output (DIO) channels, and a 32-bit counter with a Full Speed USB interface. Digital I/O The NI USB-6008/6009 has 12 digital lines, P0.<0..7> and P1.<0..3>,which comprise the DIO port. GND is the ground-reference signal for the DIO port. You can individually program all lines as inputs or outputs. Digital I/O Circuitry Figure below shows P0.<0..7> connected to example signals configured as digital inputs and digital outputs. You can configure P1.<0..3> similarly.

Event Counter You can configure PFI 0 as a source for a gated inverter counter input edge count task. In this mode, falling-edge events are counted using a 32-bit counter. I/O Protection To protect the NI USB-6008/6009 against overvoltage, under voltage, and over current conditions, as well as ESD events, you should avoid these fault conditions by using the following guidelines: If you configure a DIO line as an output, do not connect it to any external signal source, ground signal, or power supply. If you configure a DIO line as an output, understand the current requirements of the load connected to these signals. Do not exceed the specified current output limits of the DAQ device. National Instruments has several signal conditioning solutions for digital applications requiring high current drive. If you configure a DIO line as an input, do not drive the line with voltages outside of its normal operating range. The DIO lines have a smaller operating range than the AI signals. Treat the DAQ device as you would treat any static sensitive device. Always properly ground yourself and the equipment when handling the DAQ device or connecting to it. Exercise 1: Connect led as a digital output on DAQ and control a led from your front panel on labview. Exercise 2: Connect switch as digital input for DAQ indicate switch status by led on your front panel. Exercise 3: Implement event counter using DAQ. Exercise 4: Implement flasher using DAQ>