Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Similar documents
Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

Low Voltage and Medium Voltage Direct Replacement and Retrofill Circuit Breakers Selector Guide

Switchgear Survival Guide: Ten Tips to Optimize Switchgear and Enhance Reliability

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

GE Industrial Solutions. Aftermarket Solutions. Product Portfolio

Risk Mitigation of Aging Electrical Infrastructure

Medium Voltage Metal-Enclosed Power Capacitor Banks

Innovation for MV distribution

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

TRENDS IN SWITCHGEAR SPECIFICATIONS

White Paper. UL Standards for Power Control System Equipment

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Refurbishment of Switchgear and Switchgear Devices

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1. Coordination of series-rated devices is permitted where indicated on Drawings.

EntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability.

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

Power Control Systems

SACE Emax 2 Specification guide

Spectra RMS Circuit Breakers with microentelliguard Trip Units

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins

Switchgear FEATURE. Basler Electric Company

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

ABB Medium Voltage Days 2016 Asset service innovation Solutions along the lifecycle

Free Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

NW08 to NW63 fixed circuit breakers Circuit breakers

SECTION SWITCHGEAR

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Mitigating Arc Flash Hazards

Type VR Electrically Operated Ground and Test Device

Advanced Monitoring Solutions for Critical Electric Power Transmission & Distribution Assets

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Your partner in energy solutions. Systems Division. Automation & services. (Formerly Pauwels Canada Inc)

Fundamentals of Circuit Breaker Maintenance. AVO Training Institute, Inc. 2018

Smart Systems. Smart Systems

Modular, scalable, high-efficiency power protection for data centers

Medium voltage switchgear With fixed pattern circuit breaker GenieEvo

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM

DNB Power and Control System Information and Interim Safety Procedures. Version draft 5/06/08

SECTION SWITCHBOARDS

Elastimold Molded Vacuum Recloser - MVR

Grid Automation packaged solutions Optimal automation of medium voltage grids

Switchgear Design Impacts the Reliability of Backup Power Systems

SECTION MEDIUM-VOLTAGE CIRCUIT BREAKER SWITCHGEAR (GAS-INSULATED, VACUUM)

STEP OUT OF THE ARC FLASH HAZARD ZONE

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

Instructions for installation, operation and maintenance of the Arc Quenching Device (AQD)

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

1510 MOTOR CONTROLLERS

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

Document C0. Use for:

StruxureWare Power Monitoring Expert 8.0 Data Center Edition

SIEBREAK-VCB 5-15 kv metal-enclosed interrupter switchgear usa.siemens.com/siebreak

Electrical solutions for buildings. Energizing tomorrow s buildings, today

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Air-insulated medium-voltage secondary distribution switchgear

DESCRIPTIVE BULLETIN. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear

SECTION METAL-CLAD MEDIUM VOLTAGE SWITCHGEAR (VacClad-W)

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

SECTION DISCONNECT SWITCHES

SERIES SD3800 / SD3810 SPECIFICATION

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

T300MVi MEDIUM VOLTAGE DRIVES

Series 2400 Paralleling Switchgear

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Power-Style QED-2, Series 2 Low Voltage Switchboards

Products Portfolio. Pole mounted Vacuum Recloser

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Prime Point on Wave Energy Reducing Switchgear ( SWITCHGEAR ).

GE Energy Industrial Solutions. Entellisys 4.5. Low-Voltage Switchgear Application Guide

Product brochure. Cyberex. Remote Power Panel (RPP) Power distribution system

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer

PRODUCT BROCHURE. Cyberex Remote Power Panel (RPP) Power distribution system

60103 Circuit Breaker

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

TSC Schneider-PDI Agenda

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

RELT Reduced Energy Let Thru 2018

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS

Modular, scalable, high-efficiency power protection for data centers

Benefits, offering and references

TeSys IEC Contactors and Overload Relays

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Transcription:

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much time and money on equipment maintenance?

Square D Services: Your source for circuit breaker excellence. Square D Services brings together exceptional circuit breaker technology, engineering and installation expertise in complete solutions designed to minimize downtime, improve reliability and extend the life of your existing equipment. The heart of any industrial facility is its electrical distribution system In an industrial facility, nothing operates without a reliable flow of electricity. Therefore, it is critical to properly maintain the switchgear that houses overcurrent protective devices, including circuit breakers, fuses or protective relays. However, even with annual maintenance there may be instances where repairs and/or upgrades are necessary. Factors to consider include the operating environment, the availability of spare parts, reliability and the cost of ongoing maintenance. Another consideration may be the need to increase the switchgear s fault or continuous current rating or the desire to upgrade technology. As a result, facility managers are often faced with the choice of maintaining aging (or obsolete) equipment or replacing it with a new switchgear line-up to take advantage of current technology. Upgrade existing equipment Square D Services offers two additional options that are cost-effective and will expand the capabilities of your electrical system with minimal downtime. Our direct replacement and retrofill solutions utilize the upgraded technology of our Masterpact NT/NW insulated case circuit breaker for low voltage systems or the Magnum TM circuit breaker for medium voltage systems. Masterpact NT/NW Low Voltage Circuit Breakers These state-of-the-art circuit breakers provide solid state protection, reduce the potential for an arc flash event and do not require maintenance under normal operating conditions. Designs are available for most manufacturers low voltage switchboards and switchgear. Magnum Medium Voltage Circuit Breakers Each Magnum circuit breaker is manufactured using totally new components including state-of-the art vacuum or SF6 arc interruption technology. Designs are available in 5kV to15kv for most manufacturers switchgear. The benefits of utilizing the existing switchgear structure include: An economical alternative to purchasing new equipment The footprint of the equipment line-up is not affected The downtime is minimized when compared with equipment demolition and replacement Cable damage, replacement or splicing is negated Upgrades can be performed on an incremental basis to meet budget constraints or outage opportunities 3

Square D Services Modernization Solutions The right solution for your application. Two different upgrade solutions with the same end result: improved power system reliability and lower life cycle costs. Retrofill The existing switchgear cell and bus are modified to accept the new circuit breaker. Low Voltage - This solution provides a Masterpact cradle and circuit breaker, along with a new racking mechanism and primary and secondary connections in each switchgear cell. Existing cells are modified to accept the new cradle and circuit breaker, including a custom-engineered connection between the cradle and the switchgear line and load side bus. Custom designs are available for most brands of low voltage switchgear. Medium Voltage - This solution upgrades switchgear by installing a new medium voltage circuit breaker and cell into an existing line-up. Necessary modifications including an all-new racking mechanism, primary and secondary disconnects and customized connections are made to the existing cell. Available designs include: Air-Magnetic to Vacuum or SF6 Air-Blast to Vacuum or SF6 OCB Switchgear to Vacuum or SF6 Switchgear Convert Stationary Circuit Breaker to Draw-Out or Obsolete Air Circuit Breaker to Vacuum or SF6 Direct Replacement A new circuit breaker and adapter cradle fit into the existing cubicle with little-to-no cell modification, resulting in minimal downtime. Low Voltage - A standard Masterpact cradle is installed into an adapter cradle to form one assembly, which is then installed into the switchgear cubicle. (This cradle-in-cradle assembly locks into place and will remain in the switchgear cell after the initial installation.) The new Masterpact circuit breaker racks in and out of the adapter cradle. A new door is installed, however cell interlocks, the racking mechanism and the switchgear structure are not modified. Designs are available for most manufacturers switchgear. Medium Voltage The Magnum direct replacement circuit breaker will rack into the switchgear line-up and correctly interface with the existing compartment cell. The original racking mechanism, safety interlocks and the primary / secondary disconnects inherent in the original equipment design are maintained and the switchgear structure is not modified. Magnum medium voltage direct replacement circuit breakers are available for most manufacturers switchgear. 4

Low and Medium Voltage Circuit Breakers Why upgrade? When considering whether to replace or upgrade your existing switchgear, there are a number of factors to consider. One which many people never think about is conduit placement. Before After Installing new switchgear (which is usually smaller than the older/obsolete equipment it is designed to replace) requires that existing conduit above and below the equipment be moved. This time consuming and expensive process is eliminated by upgrading existing equipment with solutions from Square D Services. Improved Reliability Dash-pot style or air break interrupting devices on existing circuit breakers may have reliability issues - Many do not trip at all - Those that trip are not repeatable and may be well outside the time-current coordination parameters Aging materials reduce equipment reliability - Dielectric breakdown of insulating components - Degradation of aging mechanical parts Increased Capabilities Fault current interruption - New circuit breakers are available with higher ratings - In most cases the interruption capacity of the entire switchgear can be increased with an engineering study and a circuit breaker upgrade or replacement Arc flash limiting circuit breaker availability Trip unit accuracy and repeatability Power metering, monitoring and communication Reduced Maintenance Costs Older power circuit breakers require periodic maintenance and overhaul, which is expensive and time consuming - Lengthens outages - May require outside support Many components for existing circuit breakers are no longer supported - New parts are no longer available - The quantity and quality of used or reconditioned parts is decreasing - Prices of used or reconditioned parts are increasing Masterpact and Magnum replacement breakers for switchgear modernization are installed, tested and commissioned by factory-trained Square D Service technicians and are backed by a one-year warranty. Magnum Replacement Circuit Breaker Masterpact Replacement Circuit Breaker 5

Square D Services Modernization Solutions Masterpact NT/NW Low Voltage Direct Replacement Circuit Breakers Masterpact NT/NW power circuit breakers are designed to help protect electrical systems from damage caused by overloads, short circuits and equipment ground faults. Providing the latest in breaker technology, Masterpact circuit breakers feature high ampere interrupting and short-time current ratings, Modbus communication protocol and field-installable devices, including sensor plugs and accessories. Masterpact circuit breakers do not require maintenance under normal operating conditions. Completely modular in design, all replaceable parts can be installed with hand tools and require no critical adjustments. Additional features include: Drawout breakers with three racking positions and status indicator on cradle High ampere interrupting rating (AIR) High short-time current rating Drawout or fixed mount, 3- or 4-pole construction Integral ground-fault protection for equipment Protective relaying functions Zone-selective interlocking (ZSI), which can reduce damage in the event of a fault Field-installable accessories Meets the requirements of UL 489, UL 1066, ANSI, IEC 60947-2 and CE Mark standards Benefits include: Reduced maintenance requirements; no lubrication or adjustments required Shutters are provided, potentially reducing PPE required to remove breakers MicroLogic Trip Units: Protection and Communications For smarter breakers, a complete line of Micrologic trip units are available for use with Masterpact circuit breakers. These trip units provide TRIP UNIT TYPES TRIP UNIT FEATURES Basic A P H Open and close the circuit breaker n n n Circuit breaker position and status: Open / Tripped / Closed / Connected / Test / Disconnected n n n Display all measurements and settings n n n View current and voltage waveforms Fine settings n n Read all logged data n n Maintenance record n n Micrologic Trip Units Standard Masterpact designs are available for most manufacturers low voltage switchgear for direct replacement or retrofill applications. Fused for short-circuit protection Choice of Micrologic solid state trip unit devices for overload protection Micrologic trip units provide three levels of protection combined with three levels of functionality: Current (type A), Power (type P) and Harmonics (type H). Functions include: Load protection Power measurement Power monitoring Maintenance monitoring 6

Low and Medium Voltage Circuit Breakers Magnum Medium Voltage Direct Replacement Circuit Breakers Reduced Costs for Equipment Upgrades New circuit breakers installed in existing switchgear Available in 5kV to 15kV versions Utilizes new vacuum and SF6 arc interruption Upgraded MVA ratings are available Installation expense is a fraction of new equipment costs Reduced maintenance and operating costs Less Down Time for Installation Rolls into the existing cell with little-to-no modifications - A bus outage may not even be required Complete factory testing backed by standard equipment warranty Installation overseen by trained technician Enhanced Equipment Reliability Designed to meet ANSI/IEEE C37.59 standards Manufactured with all new components High dielectric strength, moisture resistance, primary insulation Nuclear certification available Available for Most Manufacturer s Equipment General Electric Allis-Chalmers and Siemens/Allis Westinghouse and Cutler-Hammer ITE/ABB McGraw Edison FPE Square D The Magnum operating mechanism is simple to inspect and maintain. 7

Why Choose Square D Services? Square D Services from Schneider Electric, offers a broad range of service solutions to support any manufacturers electrical distribution equipment. Whether the solution is refurbishment, replacement, maintenance or recommendations to optimize your existing system, our nationwide network of qualified experts offers a complete service package. For more information call 1-888-SQUARED or visit us online at www.squared-services.com Emergency Services & Disaster Recovery 1-888-778-2733 24 hours/day 7 days/week Schneider Electric North American Operating Division 9870 Crescent Park Drive West Chester, OH 45069 Tel: 513-777-4445 Fax: 513-755-5028 2009 Schneider Electric. All rights reserved. 1910BR0801 4-09