Transcription

1 Fundamentals of Circuit Breaker Maintenance 1 AVO Training Institute, Inc. 2018

2 Moderator n Ron Spataro AVO Training Institute Marketing Manager 2

3 Q&A n Send us your questions and comments during the presentation 3

4 Today s Presenter Mike Carter AVO Training Institute, Senior Instructor and Curriculum Advisor 4

5 Definition and Purpose of Circuit Breakers Definition A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. Its basic function is to interrupt current flow after a fault is detected. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation. 5

6 Definition and Purpose of Circuit Breakers Definition Circuit breakers are made in varying sizes, from small devices that protect low-current circuits or individual household appliance, up to large switchgear designed to protect high voltage circuits feeding an entire city. The generic function of a circuit breaker, RCD or a fuse, as an automatic means of removing power from a faulty system is often abbreviated as OCPD (Over Current Protection Device). 6

7 Definition and Purpose of Circuit Breakers 7 Purpose Interconnection of multiple generator sources into an electrical grid required development of circuit breakers with increasing voltage ratings and increased ability to safely interrupt the increasing short-circuit currents produced by networks. Simple air-break manual switches produced hazardous arcs when interrupting high voltages; these gave way to oilenclosed contacts, and various forms using directed flow of pressurized air, or of pressurized oil, to cool and interrupt the arc.

8 Definition and Purpose of Circuit Breakers Purpose All circuit breaker systems have common features in their operation, but details vary substantially depending on the voltage class, current rating and type of the circuit breaker. The circuit breaker must first detect a fault condition. In small mains and low voltage circuit breakers, this is usually done within the device itself. Circuit breakers for large currents or high voltages are usually arranged with protective relay pilot devices to sense a fault condition and to operate the opening mechanism. 8

9 Definition and Purpose of Circuit Breakers Purpose These typically require a separate power source, such as a battery, although some high-voltage circuit breakers are selfcontained with current transformers, protective relays, and an internal control power source. Once a fault is detected, the circuit breaker contacts must open to interrupt the circuit; this is commonly done using mechanically stored energy contained within the breaker, such as a spring or compressed air to separate the contacts. 9

10 Definition and Purpose of Circuit Breakers Purpose Circuit breakers may also use the higher current caused by the fault to separate the contacts, such as thermal expansion or a magnetic field. Small circuit breakers typically have a manual control lever to switch off the load or reset a tripped breaker, while larger units use solenoids to trip the mechanism, and electric motors to restore energy to the springs. 10

11 Definition and Purpose of Circuit Breakers Purpose The circuit breaker contacts must carry the load current without excessive heating, and must also withstand the heat of the arc produced when interrupting (opening) the circuit. Contacts are made of copper or copper alloys, silver alloys and other highly conductive materials. Service life of the contacts is limited by the erosion of contact material due to arcing while interrupting the current. 11

12 12 Air, Low- Voltage Power Circuit Breakers

13 Air, Low- Voltage Power Circuit Breakers 13 Visual and Mechanical Inspection Inspect physical and mechanical condition. Inspect anchorage, alignment, and grounding. Verify that all maintenance devices are available for servicing and operating the breaker. Prior to cleaning the unit, perform as-found tests, if required. Clean the unit. Inspect arc chutes. Inspect moving and stationary contacts for condition, wear, and alignment.

14 Air, Low- Voltage Power Circuit Breakers Visual and Mechanical Inspection Verify that primary and secondary contact wipe and other dimensions vital to satisfactory operation of the breaker are correct. Perform all mechanical operator and contact alignment tests on both the breaker and its operating mechanism in accordance with manufacturer s published data. 14

15 Air, Low- Voltage Power Circuit Breakers Visual and Mechanical Inspection Inspect bolted electrical connections for high resistance using one or more of the following methods: Use of a low-resistance ohmmeter Verify tightness of accessible bolted electrical connections by calibrated torque-wrench method in accordance with manufacturer s published data or Neta Table Perform a thermographic survey 15

16 Air, Low- Voltage Power Circuit Breakers Visual and Mechanical Inspection Verify cell fit and element alignment. Verify racking mechanism operation. Use appropriate lubrication on moving current-carrying parts and on moving and sliding surfaces. Perform adjustments for final protective device settings in accordance with coordination study provided by end user. Perform as-left tests. Record as-found and as-left operation counter readings. 16

17 Air, Low- Voltage Power Circuit Breakers Electrical Test Perform resistance measurements through bolted connections with a low-resistance ohmmeter. Perform insulation-resistance tests for one minute on each pole, phase-to-phase and phase-to-ground with the circuit breaker closed, and across each open pole. Apply voltage in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Neta Table

18 Air, Low- Voltage Power Circuit Breakers Electrical Test Perform a contact/pole-resistance test. (Optional) Perform insulation-resistance tests on all control wiring with respect to ground. The applied potential shall be 500 volts dc for 300-volt rated cable and 1000 volts dc for 600-volt rated cable. Test duration shall be one minute Determine long-time pickup and delay, short-time pickup and delay, ground-fault pickup and delay and instantaneous pickup current by primary current injection. 18

19 Air, Low- Voltage Power Circuit Breakers Electrical Test (Optional)Test functions of the trip unit by means of secondary injection. Perform minimum pickup voltage test on shunt trip and close coils in accordance with Neta Table Verify correct operation of auxiliary features such as trip and pickup indicators, zone interlocking, electrical close and trip operation, trip-free, antipump function, and trip unit battery condition. 19

20 Air, Low- Voltage Power Circuit Breakers Electrical Test Reset all trip logs and indicators. Verify operation of charging mechanism. Test Values Visual and Mechanical Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. 20

21 Air, Low- Voltage Power Circuit Breakers Test Values Visual and Mechanical Bolt-torque levels should be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Neta Table Results of the thermographic survey. Settings shall comply with coordination study recommendations. Operations counter should advance one digit per close-open cycle. 21

22 Air, Low- Voltage Power Circuit Breakers Test Values Electrical Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. Insulation-resistance values of breakers should be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Neta Table Values of insulation resistance less than this table or manufacturer s recommendations should be investigated. 22

23 Air, Low- Voltage Power Circuit Breakers Test Values Electrical Microhm or dc millivolt drop values should not exceed the high levels of the normal range as indicated in the manufacturer s published data. If manufacturer s data is not available, investigate values that deviate from adjacent poles or similar breakers by more than 50 percent of the lowest value. Insulation-resistance values of control wiring should be comparable to previously obtained results but not less than two megohms. 23

24 Air, Low- Voltage Power Circuit Breakers Test Values Electrical Pickup values and trip characteristic should be as specified and within manufacturer s published tolerances. Minimum pickup voltage on shunt trip and close coils should be in accordance with manufacturer s published data. In the absence of manufacturer s published data, refer to Neta Table Auxiliary features should operate in accordance with manufacturer s published data. 24

25 25 Circuit Breakers, Air, Medium-Voltage

26 Circuit Breakers, Air, Medium-Voltage Visual and Mechanical Inspection Inspect physical and mechanical condition. Verify that all maintenance devices are available for servicing and operating the breaker. Perform operator analysis (first-trip) test. Prior to cleaning the unit, perform as-found tests, if required. Inspect arc chutes. Inspect moving and stationary contacts for condition, wear, and alignment. 26

27 Circuit Breakers, Air, Medium-Voltage Visual and Mechanical Inspection If recommended by manufacturer, slow close/open breaker and check for binding, friction, contact alignment, contact sequence, and penetration. Verify that contact sequence is in accordance with manufacturer s published data. Perform all mechanical operation tests on the operating mechanism in accordance with manufacturer s published data. 27

28 Circuit Breakers, Air, Medium-Voltage Visual and Mechanical Inspection Inspect bolted electrical connections for high resistance using one or more of the following methods: Use of a low-resistance ohmmeter, verify tightness of accessible bolted electrical connections by calibrated torque-wrench or perform a thermographic survey. Verify cell fit and element alignment. Verify racking mechanism operation. 28

29 Circuit Breakers, Air, Medium-Voltage Visual and Mechanical Inspection Inspect puffer operation. Use appropriate lubrication on moving current-carrying parts and on moving and sliding surfaces. (Optional) Perform time-travel analysis. Perform as-left tests. Record as-found and as-left operation-counter readings. 29

30 Circuit Breakers, Air, Medium-Voltage Electrical Tests Perform resistance measurements through bolted connections with a low-resistance ohmmeter. Perform insulation-resistance tests for one minute on each pole, phase-to-phase and phase-to-ground with the circuit breaker closed, and across each open pole. Apply voltage in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Table

31 Circuit Breakers, Air, Medium-Voltage Electrical Tests Perform a contact/pole-resistance test. With the breaker in a test position, perform the following tests: Trip and close breaker with the control switch. Trip breaker by operating each of its protective relays. Verify mechanism charge, trip-free, and antipump functions. (Optional)Perform minimum pickup voltage tests on trip and close coils 31

32 Circuit Breakers, Air, Medium-Voltage Electrical Tests (Optional) Perform power-factor or dissipation-factor tests with breaker in both the open and closed positions and each bushing equipped with a power-factor/capacitance tap. In the absence of a power-factor/ capacitance tap, perform hotcollar tests. (Optional) Perform a dielectric withstand voltage test on each phase with the circuit breaker closed and the poles not under test grounded. Test voltage should be in accordance with manufacturer s published data or Neta Table

33 Circuit Breakers, Air, Medium-Voltage Electrical Tests Verify blowout coil circuit continuity. Verify operation of cubicle space heaters. Test Values Visual and Mechanical Compare first-trip operation time and trip-coil current waveform to manufacturer s published data. In the absence of manufacturer's published data, compare first-trip operation time and trip coil current waveform to previously obtained results. 33

34 Circuit Breakers, Air, Medium-Voltage Test Values Visual and Mechanical Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. Bolt-torque levels should be in accordance with manufacturer s published data. Results of the thermographic survey. Compare travel and velocity values to manufacturer s published data and previous test data. 34

35 Circuit Breakers, Air, Medium-Voltage Test Values Visual and Mechanical Operations counter should advance one digit per close-open cycle. Test Values Electrical Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. 35

36 Circuit Breakers, Air, Medium-Voltage 36 Test Values Electrical Insulation-resistance values of circuit breakers should be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Neta Table Values of insulation resistance less than this table or manufacturer s recommendations should be investigated. Microhm or dc millivolt drop values shall not exceed the high levels of the normal range as indicated in the manufacturer s published data. If manufacturer s data is not available, investigate values that deviate from adjacent poles or similar breakers by more than 50 percent of the lowest value.

37 Circuit Breakers, Air, Medium-Voltage Test Values Electrical Breaker mechanism charge, close, open, trip, trip-free, and antipump features shall function as designed. Minimum pickup for trip and close coils shall be in accordance with manufacturer s published data. Power-factor or dissipation-factor values shall be compared with previous test results of similar breakers or manufacturer s published data. 37

38 Circuit Breakers, Air, Medium-Voltage Test Values Electrical Power-factor or dissipation-factor and capacitance values should be within ten percent of nameplate rating for bushings. Hot collar tests are evaluated on a milliampere/ milliwatt loss basis, and the results should be compared to values of similar bushings. If no evidence of distress or insulation failure is observed by the end of the total time of voltage application during the dielectric withstand voltage test, the circuit breaker is considered to have passed the test. 38

39 Circuit Breakers, Air, Medium-Voltage Test Values Electrical The blowout coil circuit should exhibit continuity. Cubicle space heaters should be operational. 39

40 40 Circuit Breakers, Vacuum, Medium-Voltage

41 Circuit Breakers, Vacuum, Medium-Voltage Visual and Mechanical Inspection Inspect physical and mechanical condition. Inspect anchorage, alignment, and grounding. Verify that all maintenance devices are available for servicing and operating the breaker (Optional)Perform operator analysis (first-trip) test. Prior to cleaning the unit, perform as-found tests, if required. Clean the unit. Inspect vacuum bottle assemblies. 41

42 Circuit Breakers, Vacuum, Medium-Voltage Visual and Mechanical Inspection Measure critical distances such as contact gap as recommended by the manufacturer. If recommended by the manufacturer, slow close/open the breaker and check for binding, friction, contact alignment, contact sequence, and penetration. Perform all mechanical operation tests on the operating mechanism in accordance with manufacturer s published data. 42

43 Circuit Breakers, Vacuum, Medium-Voltage Visual and Mechanical Inspection Inspect bolted electrical connections for high resistance using one or more of the following methods: 1. Use of a low-resistance ohmmeter. 2. Verify tightness of accessible bolted electrical connections by calibrated torque-wrench method in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Neta Table Perform a thermographic survey 43

44 Circuit Breakers, Vacuum, Medium-Voltage Visual and Mechanical Inspection Verify cell fit and element alignment. Verify racking mechanism operation. Inspect vacuum bellows operation. Use appropriate lubrication on moving current-carrying parts and on moving and sliding surfaces. Perform time-travel analysis. Perform as-left tests. Record as-found and as-left operation counter readings. 44

45 Circuit Breakers, Vacuum, Medium-Voltage Electrical Test Perform resistance measurements through bolted connections with a low-resistance ohmmeter. Perform insulation-resistance tests for one minute on each pole, phase-to-phase and phase-to-ground with circuit breaker closed and across each pole with the breaker open. Apply voltage in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Table

46 Circuit Breakers, Vacuum, Medium-Voltage Electrical Test (Optional)Perform insulation-resistance tests on all control wiring with respect to ground. Perform a contact/pole-resistance test. With breaker in a test position, perform the following tests: 1. Trip and close breaker with the control switch. 2. Trip breaker by operating each of its protective relays. 3. Verify mechanism charge, trip-free, and antipump functions. 46

47 Circuit Breakers, Vacuum, Medium-Voltage Electrical Test (Optional) Perform minimum pickup voltage tests on trip and close coils. (Optional) Perform power-factor or dissipation-factor tests on each pole with the breaker open and each phase with the breaker closed. (Optional) Perform power-factor or dissipation-factor tests on each bushing equipped with a power-factor/capacitance tap. In the absence of a power-factor/ capacitance tap, perform hot-collar tests. 47

48 Circuit Breakers, Vacuum, Medium-Voltage Electrical Test Perform a vacuum bottle integrity (dielectric withstand voltage) test across each vacuum bottle with the breaker in the open position in strict accordance with manufacturer s published data. (Optional) Perform a dielectric withstand voltage test on each phase with the circuit breaker closed and the poles not under test grounded. Test voltage should be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Neta Table

49 Circuit Breakers, Vacuum, Medium-Voltage Test Values Visual and Mechanical Compare first-trip operation time and trip-coil current waveform to manufacturer s published data. In the absence of manufacturer's published data, compare first-trip operation time and trip coil current waveform to previously obtained results. Mechanical operation and contact alignment should be in accordance with manufacturer s published data. Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. 49

50 Circuit Breakers, Vacuum, Medium-Voltage Test Values Visual and Mechanical Bolt-torque levels should be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Neta Table Results of the thermographic survey. Compare travel and velocity values to manufacturer s published data and previous test data. Operation counter should advance one digit per close-open cycle. 50

51 Circuit Breakers, Vacuum, Medium-Voltage Test Values Electrical Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. Insulation-resistance values of circuit breakers should be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Table

52 Circuit Breakers, Vacuum, Medium-Voltage Test Values Electrical Microhm or dc millivolt drop values shall not exceed the high levels of the normal range as indicated in the manufacturer s published data. If manufacturer s data is not available, investigate values that deviate from adjacent poles or similar breakers by more than 50 percent of the lowest value. Breaker mechanism charge, close, open, trip, trip-free, and antipump features shall function as designed. 52

53 Circuit Breakers, Vacuum, Medium-Voltage Test Values Electrical Minimum pickup for trip and close coils shall be in accordance with manufacturer s published data. In the absence of data use NetaTable Power-factor or dissipation-factor values shall be compared to manufacturer s published data. In the absence of manufacturer s published data the comparison shall be made to similar breakers. 53

54 Circuit Breakers, Vacuum, Medium-Voltage Test Values Electrical Power-factor or dissipation-factor and capacitance values should be within ten percent of nameplate rating for bushings. Hot collar tests are evaluated on a milliampere/ milliwatt loss basis, and the results should be compared to values of similar bushings. If no evidence of distress or insulation failure is observed by the end of the total time of voltage application during the vacuum bottle integrity test, the test specimen is considered to have passed the test. 54

55 Circuit Breakers, Vacuum, Medium-Voltage Test Values Electrical If no evidence of distress or insulation failure is observed by the end of the total time of voltage application during the dielectric withstand voltage test, the test specimen is considered to have passed the test. Heaters should be operational. 55

56 Summary We discussed the definition and history of circuit breakers. We addressed the Neta MTS maintenance standards for the following circuit breaker types: Low voltage air circuit breakers. Medium voltage air circuit breakers. Medium voltage vacuum breakers. In future we will discuss oil circuit breakers of all voltage classes as well as SF6 gas breakers. 56

57 Save the Date for Our Next Webinar Tuesday September 18, 2018 at 1pm 2pm CDT Title: Vacuum Interrupter Technology Presented by: Greg Richmond AVO Training Specialist - Instructor 57

58 n DLRO A micro ohmmeter Smooth DC output Programmable ramp up, time on, ramp down, and output current Battery and line operated Megger Recommended Equipment n CABA Win Interfaces with EGIL, TM1600, TM1700, and TM1800 Detailed CB analysis and comparison to historical tests Simple consistent testing Fully customizable testing with Test Plan Editor (TPE) n EGIL For substations 245kV and below Vacuum CBs, OCBs, and gang operated SF 6 CBs CBs with 1 break per phase and 1 operating mechanism (gang op) 58 n TM kV substations and below Can be used on all circuit breakers 16 main and 16 Resistor contacts per phase Gang operated or IPO OCBs, SF 6, Vacuum, GIS, Airblast Dualground testing

59 Questions? After more than 50 years, AVO Training remains a global leader in safety and maintenance training for the electrical industry. We deliver an engaging, hands-on experience for our clients in a professional, real-world environment. We strive to provide industry relevant courses in a practical and flexible learning environment through an ongoing commitment to quality service, integrity, instruction, and client satisfaction. Our goal is to convey practical job skills and career development for our clients and students by saving lives through a world-class learning experience. 59 AVO Training Institute, Inc. 2018

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety MEDIUM VOLTAGE PRODUCTS UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety 2 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Operator

More information

Certification Exams. Detailed Content Outlines Level 2 Certified Assistant Technician Level 3 Certified Technician Level 4 Certified Senior Technician

Certification Exams. Detailed Content Outlines Level 2 Certified Assistant Technician Level 3 Certified Technician Level 4 Certified Senior Technician Detailed Content Outlines Level 2 Certified Assistant Technician Level 3 Certified Technician Level 4 Certified Senior Technician Certification Exams How to Use the Detailed Content Outlines These Detailed

More information

1510 MOTOR CONTROLLERS

1510 MOTOR CONTROLLERS SECTION 262913- MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions and Division 1 specification section,

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much time and money on equipment maintenance? Square D Services: Your source for circuit breaker

More information

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements Introduction to Bus Protection By Matt Horvath, P.E. November 6, 2018 Electrical Buses Physical and Electrical Junction A bus is a critical element of a power system, as it is the point of convergence

More information

TRENDS IN SWITCHGEAR SPECIFICATIONS

TRENDS IN SWITCHGEAR SPECIFICATIONS TRENDS IN SWITCHGEAR SPECIFICATIONS What changes are we seeing in equipment specifications? What s being discussed in client meetings? What s happening in the market to support these requests? EQUIPMENT

More information

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV) 1.1 DESCRIPTIONS OF WORK A. The Bidder shall furnish and install the equipment as specified herein and as shown on the contract drawings. B. The switchgear and circuit breakers shall be manufactured by

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

NU-LEC. Loop Automation. Reclosers & Sectionalizers

NU-LEC. Loop Automation. Reclosers & Sectionalizers NU-LEC Loop Automation Reclosers & Sectionalizers 1 NU-LEC LLC NU-LEC LLC is a wholly unit of NU-LEC Industries, Pty, Ltd. Sales and service center for United States, Canada, and the Caribbean. Warehouse

More information

1. Coordination of series-rated devices is permitted where indicated on Drawings.

1. Coordination of series-rated devices is permitted where indicated on Drawings. SECTION 16055 - OVERCURRENT PROTECTIVE DEVICE COORDINATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

MV Network Switchgear, Protection and Control

MV Network Switchgear, Protection and Control MV Network Switchgear, Protection and Control Ravinder Negi Manager, Services Execution INDIA Schneider Electric, New Delhi. Agenda An Overview MV Network Basic Definitions Circuit breaker Switchgear Control

More information

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold Tru-Break switchgear module Tru-Break switchgear module agenda Design platform and value Product specifications Operation Configuration examples

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc Redundant Bus Protection Using High-Impedance Differential Relays Josh LaBlanc Purpose Discuss the configuration of the bus under study, and touch on the needs for redundant protection on the bus. Briefly

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels 4 additional analog

More information

Enabling a Solid State Circuit Breaker

Enabling a Solid State Circuit Breaker Enabling a Solid State Circuit Breaker USING SOLID-STATE CIRCUIT BREAKERS TO REVOLUTIONIZE POWER DISTRIBUTION Mike Harris Atom Power, Inc. Copyright 2019 Atom Power, Inc. All rights reserved. Enabling

More information

SECTION SWITCHGEAR

SECTION SWITCHGEAR SECTION 26 23 13 SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION Exercise 2 Single Bus Scheme EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with electric power substations using the single bus scheme with bus section circuit breakers.

More information

Uncovering Value, Instilling Confidence. Dan Hook, PE, MBA EVP-Business Development WMEA Meeting May, 2016

Uncovering Value, Instilling Confidence. Dan Hook, PE, MBA EVP-Business Development WMEA Meeting May, 2016 Uncovering Value, Instilling Confidence Dan Hook, PE, MBA EVP-Business Development WMEA Meeting May, 2016 Introduction Western Electrical Services NETA Accredited, Field Service Testing PEARL Full Member,

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT66 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

It is the job of the protection system equipment to recognize and remove the fault.

It is the job of the protection system equipment to recognize and remove the fault. Protection 1 (read section 13.0 of text) 1.0 Introduction Faults do not occur that frequently 1/year/100 miles of transmission is typical. Distribution systems may see more than this. However, when they

More information

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136 Company Directive ENGINEERING SPECIFICATION EE SPEC: 136 Ancillary Electrical Equipment for Use in Conjunction with Switchgear and Protection/Control Panels NOTE: The current version of this document is

More information

SECTION MEDIUM-VOLTAGE CIRCUIT BREAKER SWITCHGEAR (GAS-INSULATED, VACUUM)

SECTION MEDIUM-VOLTAGE CIRCUIT BREAKER SWITCHGEAR (GAS-INSULATED, VACUUM) SECTION 26 13 13 - MEDIUM-VOLTAGE CIRCUIT BREAKER SWITCHGEAR (GAS-INSULATED, VACUUM) PART 1 - GENERAL 1.1 SCOPE A. This specification defines the technical requirements for indoor, gas-insulated switchgear

More information

Elastimold Molded Vacuum Recloser - MVR

Elastimold Molded Vacuum Recloser - MVR Subject: Elastimold Recloser Technical Specification Date: 4/24/12 File: MVR-RS-0412 Page: 1 of 6 1.0 SCOPE Elastimold Molded Vacuum Recloser - MVR 1.1 This specification covers electrical and mechanical

More information

Installation. Symmetra MW II kw 400 V. UPS Summary Normal Normal

Installation. Symmetra MW II kw 400 V. UPS Summary Normal Normal UPS Summary ~ ~ Normal Normal Installation Symmetra MW II 600 kw 400 V Contents Safety... IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS.......................... Symbols used in this guide.........................

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error: 41-766.7 SSV-T and SSC-T High Drop-out Relay device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the

More information

CP30F Series Circuit Protector for Improving Safety and Wiring Workability

CP30F Series Circuit Protector for Improving Safety and Wiring Workability CP30F Series Circuit Protector for Improving Safety and Wiring Workability EMURA, Takeshi * A B S T R A C T A circuit protector is a circuit-breaker that possesses both overcurrent protection and switch

More information

ELECTRICAL CONTROL SYSTEM COMPONENTS

ELECTRICAL CONTROL SYSTEM COMPONENTS Module - 2 ELECTRICAL CONTROL SYSTEM COMPONENTS Lecture - 1 MECHANICAL SWITCHES Shameer A Koya EEET 221 : Electrical Control Systems. Module 2 - Objectives State the functions of control system components

More information

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP) Discipline Engineering Standard - NSW Category Electrical Title s Reference Number PCP 07 - (RIC Standard: EP 99 00 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Equipment Short-Circuit Current Rating and Available Fault Current

Equipment Short-Circuit Current Rating and Available Fault Current Equipment Short-Circuit Current Rating and Available Fault Current Dan Neeser Field Application Engineer Eaton s Bussmann Business Dan.Neeser@CooperIndustries.com Agenda Interrupting Rating & Series Rating

More information

Type VR Electrically Operated Ground and Test Device

Type VR Electrically Operated Ground and Test Device Type VR Electrically Operated Ground and Test Device For Use with Masterclad Switchgear 4.76 kv 15 kv, 1200, 2000, 3000, 4000 A Up to 63 ka Short Circuit Rating Class 6055 Instruction Bulletin 6055-37

More information

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Voltage Panels and Enclosures designed and built with

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

ENhanced TEChnology.  Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver. ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Ver. 081226 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser

More information

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv) Outdo Distribution (15.5 kv and 27 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The automated distribution fault interrupting system shall confm to the following specification. 1.02 The

More information

Standards Update Notice (SUN) Issued: August 11, 2017

Standards Update Notice (SUN) Issued: August 11, 2017 Standard Information Standard Number: UL 621 Standard Name: Ice Cream Makers Standard Edition and Issue Date: 7 th Edition Dated May 7, 2010 Date of Revision: February 15, 2017 Date of Previous Revision

More information

Circuit Breakers,Reclosers, Switches, and Fuses

Circuit Breakers,Reclosers, Switches, and Fuses Section 17 Circuit Breakers,Reclosers, Switches, and Fuses 170. ARRANGEMENT This rule requires circuit breakers, reclosers, switches, and fuses be accessible only to qualified persons. Section 17 is part

More information

S&C Circuit-Switchers Mark VI

S&C Circuit-Switchers Mark VI S&C Circuit-Switchers Mark VI Outdoor Transmission (69 kv through 138 kv) Mark VI Circuit-Switcher with Pre-insertion Inductors... the most reliable way to switch and protect substation capacitor banks

More information

ABB Group - Bob van Evelingen. March 26, 2009 Slide Series. 600-Series. Transmiss. ABB Group - Bob van Evelingen. March 26, 2009 Slide 5

ABB Group - Bob van Evelingen. March 26, 2009 Slide Series. 600-Series. Transmiss. ABB Group - Bob van Evelingen. March 26, 2009 Slide 5 Arc Protection REA101 REA 101 A01 REA101 REA101 Open Close Bob van Evelingen Seminar / Maart-April 2009 Protection & Testing Relays, Breakers, Busbars, Transformers, Batteries Close March 26, 2009 Slide

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

4. CIRCUIT BREAKERS. Functional Emergency Switching

4. CIRCUIT BREAKERS. Functional Emergency Switching 4. CIRCUIT BREAKERS The circuit breaker/disconnector fulfils all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist. As shown in table H2-19 the circuit

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

ENhanced TEChnology.   Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

ELG4125: System Protection

ELG4125: System Protection ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.

More information

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing Understanding SCCR What is SCCR? When it comes to industrial machinery, it s critical to ensure that electrical panels are designed and built with the proper SCCR to maintain the system, eliminate downtime

More information

Purpose of High Voltage Circuit Switchers

Purpose of High Voltage Circuit Switchers Purpose of High Voltage Circuit Switchers Vertical interrupter circuit switcher without integral disconnect switch (Figure 2) Three-phase Interruption and Protection Circuit switchers have been developed

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

Circuit Breaker Asset Management using Intelligent Electronic Device (IED) Based Health Monitoring

Circuit Breaker Asset Management using Intelligent Electronic Device (IED) Based Health Monitoring Circuit Breaker Asset Management using Intelligent Electronic Device (IED) Based Health Monitoring Carey Schneider Mike Skidmore Zak Campbell Jason Byerly Kyle Phillips American Electric Power October

More information

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application Overhead Source-Transfer Application Detailed Functional Specification Guide 1.0 GENERAL 1.01 The automated distribution fault-interrupting system shall conform to the following specification. 1.02 The

More information

PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR

PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR POWR-GARD Supplemental Monitoring PGM-8325 SERIES Neutral Grounding Monitor PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR JULY 2, 2009 REVISION 10 F 1 CT1 CT2 A B L1 L2 GROUND FAULT 1.0 RESET RESISTOR FAULT

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit. Exercise 3-1 Motor Starters EXERCISE OBJECTIVE Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit. DISCUSSION OUTLINE The Discussion of this exercise

More information

Surge Protective Device

Surge Protective Device SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous

More information

Standards Update Notice (SUN) Issued: April 25, 2017

Standards Update Notice (SUN) Issued: April 25, 2017 Standard Information Standard Number: UL 1951 Standard Name: Electric Plumbing Accessories Standard Edition and Issue Date: 2 nd Edition Dated July 22, 2011 Date of Revision: February 21, 2017 Date of

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer

More information

Products Portfolio. Pole mounted Vacuum Recloser

Products Portfolio. Pole mounted Vacuum Recloser Products Portfolio Pole mounted Vacuum Recloser Efacec Switchgear Efacec Switchgear is a leading company in Portugal and a worldwide reference in the development of solutions for power generation, transmission,

More information

CBA HV Circuit Breaker Analyzer and Microhmmeter

CBA HV Circuit Breaker Analyzer and Microhmmeter CBA 2000 HV Circuit Breaker Analyzer and Microhmmeter Built-in 200 A microhmmeter Up to 18 main and 18 resistive contact inputs 12 auxiliary timing inputs Up to 4 trip/close coils control Motion and speed

More information

Smart Primary Injection High Current Testing Product Line. EPRI CBUD Users Group Meeting June

Smart Primary Injection High Current Testing Product Line. EPRI CBUD Users Group Meeting June Smart Primary Injection High Current Testing Product Line EPRI CBUD Users Group Meeting June 17 2010 1 1 Why get Smart? Megger has had Primary Current Injection with: DDA Series CB Series MS Series ODEN

More information

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation SECTION 26 24 16 PANELBOARDS PART 1 -GENERAL 1.1 SUMMARY A. Section includes distribution and branch circuit panelboards, electronic grade branch circuit panelboards, [and load centers]. 1.2 REFERENCES

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

SERIES SD3800 / SD3810 SPECIFICATION

SERIES SD3800 / SD3810 SPECIFICATION SERIES SD3800 / SD3810 SPECIFICATION SOLID DIELECTRIC SINGLE SIDED 15 KV & 25 KV PADMOUNTED VACUUM LOAD INTERRUPTERS AND VACUUM FAULT INTERRUPTERS WITH VISIBLE DISCONNECTS MANUALLY OPERATED / REMOTELY

More information

Tmax molded case circuit breakers Specification guide

Tmax molded case circuit breakers Specification guide Tmax molded case circuit breakers Specification guide Tmax Specification Guide 1 Specification Number: 26 28 16.14 Product Name: MOLDED CASE CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings

More information

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated with

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-39016/41E 15 June 2005 SUPERSEDING MIL-PRF-39016/41D 20 July 1988 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE, TERMINALS

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

ABB Data Center Forum 2017

ABB Data Center Forum 2017 ABB DATA CENTER FORUM 2017, 11 TH JULY 2017 ABB Data Center Forum 2017 Perfecting Data Center availability with Ultra-Fast Protection Devices Barbara Schlegel ABB DATA CENTER FORUM 2017, 11 TH JULY 2017

More information

CT-8000 S3. digital circuit breaker analyzer

CT-8000 S3. digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer Product Overview The CT-8000 S3 is Vanguard's fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available

More information

The Role of Semiconductor Devices in High Power Circuit Breaker Applications

The Role of Semiconductor Devices in High Power Circuit Breaker Applications The Role of Semiconductor Devices in High Power Circuit Breaker Applications NOEL Y A SHAMMAS Faculty of Computing, Engineering and Technology Staffordshire University P.O. Box 334 Beaconside Stafford

More information

6R MATRIX Pre-Defined. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

6R MATRIX Pre-Defined. Modular Relays. rms. Auxiliary, Trip & Supervision Relays Pre-Defined Modular Relays Auxiliary, Trip & Supervision Relays Rugged modular construction Rack or flush mounting Range of function types Draw out module, & 20 contact versions Operating & reset coils

More information

Mitigating Arc Flash Hazards

Mitigating Arc Flash Hazards 1910DB1402 / March, 2015 by Antony Parsons, Ph.D., P.E. and Reza Tajali, P.E. Schneider Electric Engineering Services Make the most of your energy SM Contents 1.0 Introduction... 3 2.0 What is Arc Flash

More information

Switchgear Survival Guide: Ten Tips to Optimize Switchgear and Enhance Reliability

Switchgear Survival Guide: Ten Tips to Optimize Switchgear and Enhance Reliability Switchgear Survival Guide: Ten Tips to Optimize Switchgear and Enhance Reliability 1910DB1207 By Hal Theobald, Product Marketing Manager, Schneider Electric Services Summary 1.0 Abstract...3 2.0 Introduction...3

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY SECTION 26 05 73 OVERCURRENT PROTECTIVE DEVICE PART 1 - GENERAL 1.1 SUMMARY A. Section includes computer-based, fault-current and overcurrent protective device coordination studies. Protective devices

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers Circuit Breaker Sentinel (CBS) for SF 6 power circuit breakers Circuit Breaker Sentinel (CBS) for SF 6 power circuit breakers It is widely recognized that the concept of periodic equipment maintenance

More information

ICX-CMOS-E-2006 Electrical / I&C Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

ICX-CMOS-E-2006 Electrical / I&C Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS 102904-ICX-CMOS-E-2006 Electrical / I&C Engineer Holds a B. Sc. in Electronics & Electrical Communications Engineering and has over 9 years hands-on experience working in I&C field. Has extensive experience

More information

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives TM MODERNIZE YOUR DC CRANES Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives Magnetek, the leader in digital power and motion control systems, brings you the

More information

Document C0. Use for:

Document C0. Use for: Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized

More information

Medium Voltage Metal-Enclosed Power Capacitor Banks

Medium Voltage Metal-Enclosed Power Capacitor Banks 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Power Capacitor Banks General Northeast Power System s (NEPSI's) medium

More information

CERTIFIED TEST REPORT

CERTIFIED TEST REPORT CP No.: CP1120 Rev. 1 Page: 1 of 24 CERTIFIED TEST REPORT Cooper Power Systems 15 kv Class 600 Amp CLĒĒR TM LOADBREAK SEPARABLE CONNECTOR SYSTEM REV. 1 DATE September 1, 2011 ORIGINAL REPORT DATE: July

More information

CAT II series Circuit Breaker Analyzers & Timers

CAT II series Circuit Breaker Analyzers & Timers CAT II series Circuit Breaker Analyzers & Timers Robust design for field use Accurate measurement in high voltage environment Timing and motion measurement Both Sides Grounded feature Built-in micro ohmmeter

More information

ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER

ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER smallhydro PRIME ENGINEERING LIMITED IS AN ELECTRICAL ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, IMPLEMENTATION AND MAINTENANCE. OUR TEAM OF PROFESSIONALS

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 BY H S W Karunaratne Assistant Director - Engineering Sri Lanka Standards Institution. 1 DEFINITIONS Ac module:

More information

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Miniature Circuit Breakers

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Course Details Date: January 28 January 31, 2019 Time: 8:00 A.M. - 4:30 P.M. Capacity: 12 attendees Provider: National Technology

More information

DESCRIPTIVE BULLETIN. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear

DESCRIPTIVE BULLETIN. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear DESCRIPTIVE BULLETIN SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear 2 S A F E G E A R 5/ 1 5 K V, U P TO 5 0 K A A R C - R E S I S TA N T S W I TC H G E A R SafeGear meets today s challenge for

More information