Contents 1 Measurement and Machine Tools An Introduction

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

Form Measurement ROUNDTEST RA-1600

Creative Calibration Centre, Plot No.-3802, Laxman Vihar, Phase-I, Gurgaon, Haryana. Discipline Mechanical Calibration Issue Date

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Calibration House, 71, Tarani Colony, Near Amir Vila, A. B. Road, Dewas, Madhya Pradesh. Discipline Mechanical Calibration Issue Date

Reliance Calibration Laboratory, Sr. No. 21/7, (Gokul Nagar, Narhe), Lygude Estate, Dhayari-Sinhgad Road, Pune, Maharshtra

Excel Calibration Private Limited, No. 101, Legend Constructions, No /101, Barkathpura, Hyderabad, Telangana

Schedule. NO: SAMM 082 (Issue 2, 18 May 2018 replacement of SAMM 082 dated 8 December 2017) f applicable) Page: 5 of 40

STEP-BY-STEP INSTRUCTIONS FOR BUILDING AN AUTOCOLLIMATOR. TECHSPEC Optical Cage System

Sliding Prices this Winter. Local Distributor. Supporting your. Large Workshop Vernier Caliper. Traditional Feeler Gauge Set.

Micro-Flat Datums Pvt. Ltd., Plot No , Zone D-3, GIDC, Vitthal Udyognagar, Anand, Gujarat

Discipline Mechanical Calibration Issue Date Certificate Number C-0131 Valid Until Last Amended on - Page 1 of 10

PRESETTER SP40. Pesaro, September 2013

Operation Manual. Autocollimator Test Wedge for quick testing of Electronic Autocollimators

Multi-sensor measuring technology. O-INSPECT The best of optical and contact measuring technology for true 3D measurements.

ROUNDTEST RA Roundness/Cylindricity Measurment

Engineering Metrology

OPTI 513R / Optical Testing

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty

CALCULATION OF 3-D ROUGHNESS MEASUREMENT UNCERTAINTY WITH VIRTUAL SURFACES. Michel Morel and Han Haitjema

Vasals Engineering Industries, No. 33, First Floor, Govardhan Garden, J.C. Industrial Area, Kanakapura Road, Yelachenahalli, Bangalore, Karnataka

MICRO-HITE 350 / 600 / 900 Height Gages MICRO-HITE main instruments 350 / 600 / 900

Mitutoyo General Catalog

Surface Roughness Testing

Calibration of a portable interferometer for fiber optic connector endface measurements

PRECISION MEASURING INSTRUMENTS

leica industrial theodolite

Lateral scale calibration for focus variation microscopy

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Discipline Mechanical Calibration Issue Date Certificate Number C-0386 Valid Until Last Amended on - Page 1 of 6

A U T O C O L L I M A T O R S

Test Report UST - Universal Surface Tester

Ch 22 Inspection Technologies

YOUR STABLE PARTNER FOR MANUFACTURING. MARSTAND

Thickness of the standard piece: 10 mm The most important calibration data are engraved in the side face of the specimen.

f. (5.3.1) So, the higher frequency means the lower wavelength. Visible part of light spectrum covers the range of wavelengths from

ROUNDTEST RA-2200 SERIES

Superfast Optical Roughness Measurement

Friction & Roughness Measurement of Elastomer

UNIT IV - Laser and advances in Metrology 2 MARKS

Reflection and Refraction of Light

Chapter 7: Geometrical Optics. The branch of physics which studies the properties of light using the ray model of light.

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING

Mirror Example Consider a concave mirror radius -10 cm then = = Now consider a 1 cm candle s = 15 cm from the vertex Where is the image.

Probe station system

COMPARISON OF TWO INSTRUMENT DESIGNS FOR NON-CONTACT MEASUREMENT OF GOSSAMER MIRRORS

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z

SWING ARM OPTICAL CMM

Test Report UST - Universal Surface Tester

LINEAR HEIGHT LH-600 PRE 1286(2) 1-D / 2-D

Nominal depths (step heights) in µm 0.05; 0.1; 0.23; ; 2; 5; 10; 20; 50; ; 400; 500; 525; 600; 900; 1000

System for Gauge Blocks Diagnostics

Measuring instruments and systems 2009 mechanical optical electronical

TR-200 Surface roughness tester

Horizon Premium. Length Measuring and Setting Instrument. The new Trimos Horizon Premium

Design of three-dimensional photoelectric stylus micro-displacement measuring system

TESA UPD Gauge Block Comparator with a 25 mm Measuring Span

Optical 3D measurements capture the entire surface with nanometer precision

Calibration Equipment

Product Datasheet. Features Specifications Other Options

SPECIAL OFFERS 16,995 METROLOGY DIRECT 4,000. Micro-Vu Vertex 110 Vision Measuring System 2008 AUTUMN / WINTER PROMOTION

100 points 4 Pages of problems + 1 equation sheet 48 minutes. Recitation Instructor (circle one): Cardwell Griffith Nilsen Schoun Shiroyanagi Willis

MarSurf. The new generation of contour measurement systems MarSurf XC 20 MarSurf XC 2

INSPECTION FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

DATA SHEET DEA GLOBAL SILVER 09.XX XX.10

Mirror Example Consider a concave mirror radius r = -10 cm then. Now consider a 1 cm candle s = 15 cm from the vertex Where is the image.

IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS

3D Freeform Surface Measurement on Coordinate Measuring Machine Using Photometric Stereo Method

Mounting of large lenses in Infrared instruments

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE

Calibration of Optical Rotary Tables using Autocollimators and Laser Interferometer Systems

Overview over the different measurement methods for geometry error correction for measuring machines and machine tools

Micro Cutting Tool Measurement by Focus-Variation

PTZ 140 Camera Head and Kits

TECHNICAL DATA OPTIV PERFORMANCE 663/664 DUAL Z

Physics 111 Homework Solutions Week #8 - Monday

AN EVALUATION OF NON-CONTACT LASER SCANNER PERFORMANCE USING CALIBRATED ARTIFACTS

FROM THE THUMBNAIL TEST TO MARSURF.

SURFACE ROUGHNESS TESTER TR100/110

Electronic calipers Dial calipers Vernier calipers. External micrometers Internal micrometers Depth micrometers

PORTABLE SURFACE ROUGHNESS GAGE. POCKET SURF

Experimental accuracy assessment of different measuring sensors on workpieces with varying properties

LABMASTER. Pratt & Whitney UNIVERSAL MEASURING SYSTEM. Model 175. Measurement Systems, Inc.

Formtracer SV-C3200/4500 Series

Machining and metrology systems for free-form laser printer mirrors

Every tool comes with Certificate of Inspection (see back for details)

Surface Roughness Testing L-1

Prof. Alexander Slocum John Hart Pat Willoughby

LABMASTER AUTOMATIC. Pratt & Whitney. Model 1000A UNIVERSAL MEASURING SYSTEM. Measurement Systems, Inc.

LABMICROMETER. Pratt & Whitney UNIVERSAL LENGTH MEASURING SYSTEM. Measurement Systems, Inc.

Advantages of 3D Optical Profiling Over Other Measurement Technologies

Simply the best fixation. 3D articulated arms Innovative high-quality products

High Precision Optical Instrumentation for Large Structure Position Monitoring: The BCAM System Applied to the CMS Magnet

Alicona Specifications

Discipline Mechanical Calibration Issue Date Certificate Number C-1056 Valid Until Last Amended on - Page 1 of 8. 0.

Transcription:

Calibration or s Laser raiations Stabilize laser of the mise en pratique: absolute frequency Optical beat frequency 633 633 24 khz 2 95% No 08010- Laser raiations Other stabilize laser: vacuum wavelength Optical beat frequency 633 633 1.0E-09 2 95% Yes 08010-10201 0.5 125 Material steel Q[28, 0.47L ], L in, s range from 28 to 65 0.5 125 Material ceramic Q[30, 0.39L ], L in, s range from 30 to 57 0.5 125 Material tungsten carbie Q[28, 0.22L ], L in, s range from 28 to 39 0.5 125 Material chromium carbie Q[28, 0.36L ], L in, s range from 28 to 53 0.5 125 Material steel, tungsten carbie an chromium carbie Q[50, 0.50L ], L in, s range from 50 to 1.2E+02 0.5 125 Material ceramic Q[70, 0.50L ], L in, s range from 70 to 1.4E+02 The BIPM key atabase, September 2017 1/5

Calibration or s 150 1000 Material steel Q[50, 0.80L ], L in, s range from 1.3E+02 to 8.5E+02, 10502, 10503 Step gauge: face spacing up to 1020 Step gauge size < 1020 Q[0.26, 1.4E-03L ], Caliper checker: face spacing up to 1020 Caliper checker size < 1020 Q[0.30, 2.7E-03L ], Line stanar Precision line scale: line spacing Line scale up to 250 Glass scale low coefficient of thermal expansion (8E-08 K -1 ) Q[41, 100.0E- 03L ], Line stanar Precision line scale: line spacing Line scale up to 1000 Glass scale working stanar Q[0.11, 2.9E-03L ], 0.1 1 0.24 D 1 100 Q[0.23, 1.4E- s range from 0.23 to 0.27 10502 D 100 300 Q[0.25, 1.4E- s range from 0.29 to 0.49 10503 The BIPM key atabase, September 2017 2/5

Calibration or s Internal cyliner (plain ring gauge): D an focusing microscope 0.1 100 Q[0.37, 1.3E- s range from 0.37 to 0.39 Angle by circle ivier Optical polygon: face angle Inexing table an one autocollimator, error separation 3 72 faces 0.2 " 2 95% No 10201, 10202, 10203, 10204 Angle by circle ivier Inexing table: inex angle Cross calibration versus polygon an autocollimator 360/n 360/n Measure angle: 360/n, number of ivision n 3, 4, 6, 8 an 12 0.2 " 2 95% No Angle instrument Autocollimator: error of inicate angle Sine arm an autocollimator -1000 1000 " 0.2 " 2 95% No Optical flat: flatness eviation over whole Fizeau, three flat test, automatic assessment 0 0.3 60 4 10201 Optical flat, optical parallel: flatness Fizeau, automatic assessment 0 0.3 60 20, 10102 Optical parallel: parallelism Gauge block comparator 0 20 60 40 The BIPM key atabase, September 2017 3/5

Calibration or s Rounness Glass hemisphere: rounness R Multi-step, styluson-spinle rounness instrument 0 20 Diameter 1 to 355 Q[7.7, 7.6R ], R in, s range from 7.7 to 1.6E+02 Rounness Internal an external cyliner, magnification stanar: rounness R Stylus-on-spinle rounness instrument 0 20 Diameter 1 to 355 Q[12, 12R ], R in, s range from 12 to 2.2E+02 10401 5436-1, type A), epth Stylus instrument 0.025 32 Groove epth, ISO 5436-1 Q[6.6, 12 ], in, s range from 6.6 to 3.8E+02 5436-1, type A), epth Interference microscope an stylus instrument (for premeasurement) 0.01 10 Groove epth ISO 5436-1 Q[2.4, 5.4 ], in Non-contact optical 5436-1, type A), epth profiler 0.3 50 Groove epth ISO 5436-1 Q[75, 7.3], in Roughness stanar, ISO 5436-1 type C, D: Ra (ISO 4287) Stylus instrument 0.025 32 Ra (ISO 4287) ISO 4287, ISO 4288, ISO 11562 Q[10, 12Ra ], Ra in, s range from 10 to 3.8E+02 10601 The BIPM key atabase, September 2017 4/5

Calibration or s Roughness stanar, ISO 5436-1 type C, D: Rz (ISO 4287) Stylus instrument 0.025 32 Rz (ISO 4287) ISO 4287, ISO 4288, ISO 11562 Q[18, 17Rz ], Rz in, s range from 18 to 5.4E+02 10601 CMM artefacts Ball plate: 2D center coorinates using swing roun metho up to 620 x 620 Ball plate size < 620 x 620 Q[0.27, 1.9E-03L ], 2-D, 3-D instruments CMM: error of inicate [size; location; shape] Comparison with gauge blocks up to 1200 x 1000 x 700 CMM size < 1200 x 1000 x 700 Q[0.52, 1.4E-03L ], 2-D, 3-D instruments CMM: error of inicate [size; location; shape] Comparison with step gauges up to 1200 x 1000 x 700 CMM size < 1200 x 1000 x 700 Q[0.52, 2.0E-03L ], The BIPM key atabase, September 2017 5/5