The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

Similar documents
TXP3500/4000 Series AC-DC Industrial PSU

LBC Series 3-phase PSU / Battery Charger

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Other standard features include current and voltage monitoring, overvoltage, overtemperature as well as short circuit protection.

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

Bel Power Solutions AC Power Distribution Unit (PDU) is used to distribute AC voltage in IT Racks following the Open Rack specification.

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

CSPS-6K (Shelf Type) POWER you need POWER SHELF

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Simple but elegant look and ease of installation make it ideal for various industrial applications.

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

C1U-W Tx Series

Output Voltage* (nom.)(adjustable)

D1U-W Hx Series

Safety Standards. Model Number: Unit Weight:

D1U4CS-W HxxC Series AC/DC Front End Power Supply

D1U-W Hx Series

CPCI - 6U - AC - 600W

C1U-W Tx Series AC/DC Front End Power Supply

RT4F-48V/50A-WAC RECTIFIER

ORDERING INFORMATION SEE PAGE 6

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

RT4F-110V/25A RECTIFIER

RT12-240V/2.4kW Rectifier Specification

Safety Standards. Model Number:

CPCI - 6U - DC - 350W

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Output Voltage* (nom.)(adjustable)

RT4B-110V/12A RECTIFIER

FMP VDC RECTIFIER 42 Amps 2000 Watts

(877) CPCI-6U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

Safety Standards. Model Number:

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

D1U5CS-H HA4C

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

AC-DC Power Supplies. The PerFormanCe Power PFC250 meets international safety requirements and is CE Marked to the Low Voltage Directive.

750W Power Supply with Single Output. RSP-750 series. File Name:RSP-750-SPEC

TEK360M series is a fan-less 300W, U-frame, switching power supply with active PFC function for medical application. Rated Output Power.

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

PSC600-series DC/DC W

Safety Standards. Model Number:

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

RT7-48V/6kW Specification

PDD-300 pulsed diode driver

EMH Series. 250 W & 350 W Forced-cooled. Industry Standard 3 x 5 x 1.43 Format. IT & Medical (BF) Approvals. 80 V VAC Operation

Safety Standards. Model Number:

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

RT4F-120V/20A-WAC RECTIFIER

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

Safety Standards. Model Number:

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

A0750 AC-DC POWER MODULE

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

3000W Programmable Single Output AEK AEK AEK AEK

DATASHEET. Ultra Capacitor Charger, UCC-4

Safety Standards. Model Number:

Table 1 shows all the different variations of output modules available.

Safety Standards. Model Number:

RT9-48V/1.4kW Rectifier Specification

CINT W Triple Output Industrial Series

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

PMT. Safety Standards. Model Number:

Safety Standards. Model Number:

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Safety Standards. Model Number:

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Universal Power Supplies

Safety Standards. Model Number

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

H-series (Rectifier Module)

TRC ELECTRONICS, INC

General. Environmental. EMC & Safety

Max Output Power Voltage. Convection Forced Convection Forced Nom Peak (2) Model Number (1)

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Packaging (5) Protection (3) Isolation Voltage (4)

P3-SCM. General Specifications

Safety Standards. Model Number:

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Transcription:

The TXP3500/4000 series of fan cooled power supplies convert the universal 3 phase AC line to an adjustable, wide range output at 3.5/4 kw and a 12 V standby output. Thanks to active current share system up to 8 units may be operated in parallel (28/32 kw). This industrial Power Supply Unit (PSU) includes DSP technology which enables monitoring of all electrical parameters and allowing control of the PSU from a system controller via RS485 / CAN bus communication interface. The output voltage is adjustable also by a resistor connected to Margin input. The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications. WorldWide 3phase Input Voltage Range (nom. 200 Vrms to 480 Vrms) Power Factor > 0.94 High Power Density 16 W/in 3 93% Typical Efficiency Parallel Operation of up to 8 Units (28/32 kw) Serial Operation of up to 4 Units Internal Fan Cooling System 25 to 55 C of Ambient Temperature Possibility to Install 3 Units in 2U 19 Rack RS485 / CAN bus Interfaces Adjustable Output Voltage Range Auxiliary Output 12 V / 0.8 A Active or Passive Current Sharing Industrial, Process & Control, Machinery PSU with universal input voltage range (180 528 VAC line to line) and configurable output voltage.

2 TXP3500/4000 Series MODEL INPUT VOLTAGE RANGE NOMINAL VOLTAGE VOLTAGE RANGE MAX CURRENT MAX POWER AVAILABILITY TXP35001048G 180 528 Vrms, 50/60 Hz 48 V Adjustable 10 50 VDC 73 ADC 3500 W Available TXP40001110G 350 528 Vrms, 50/60 Hz 110 V Adjustable 30 137. 36.5 ADC 4000 W Available PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Input Voltage * Input Frequency Input Current * Nominal (line to line) Permitted variation: Nominal Permitted variation: Per Line TXP35001048G TXP40001110G TXP35001048G TXP40001110G 180 350 200480 400480 528 528 Vrms Vrms 50/60 Hz 47 63 Hz TXP35001048G 5 12 TXP40001110G 5.2 7 Inrush Current Per Line 60 ** Apk Power Factor 0.94 Fuse 3 x 20 A, Fast acting * Model dependent ** After one minute cooling period Arms PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Output Voltage Output Power Rating Adjustable (range see Model Selection table) @ High Line and Low Line / High Line Output Current Fixed or Adjustable (60 100%) 3500 /4000 See Model Efficiency Typical, at High Line and nom. load 93 % Voltage Setting Accuracy ± 0.5 % Line Regulation @ Io = 0.5 * Io_nom ±0.5 % Load Regulation ±0.3 % Thermal Drift ±0.02 %/ C Transient Response @ Load variation 10100% and back: @ Load variation 50100% and back: Recovery time: Recovery time: Ripple Vout_nom (BW 20 MHz) 1.5 % Output Start Up 2.5 s Rise Time 250 ms ±5 ±3 2 0.4 W % ms % ms AsiaPacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 2018 Bel Power Solutions & Protection BCD.00684_AC

TXP3500/4000 Series 3 PARAMETER Protection / Vout_OFF Warning / Alarm DESCRIPTION / CONDITION Over Temperature Protection (internal sensors) Input Under Voltage Protection Input Over Voltage Protection Reversed Sense Output Protection Output Under Voltage Protection Output Over Voltage Protection Output Over Current / Short Circuit Protection Input under voltage Input over voltage Output over voltage Output under voltage Output overload Over temperature (internal sensors) >85 C Tamb, >90/110 C Ths1/2 >70 C Tamb, >105 C Ths2 5.1 GUI (GRAPHIC USER INTERFACE) SC UTILITY AND RS485/CAN COMMUNICATION PROTOCOL Please see detailed description in document BCA.00186, for the GUI please contact a Bel Power Solutions sales representative. 5.2 LED ING LED NAME COLOR STATUS OPERATING CONDITIONS ACOK DCOK OT/FAIL Green Green/Chartreuse/Yellow Yellow ON Blinking slowly Green ON Chartreuse ON Yellow ON Blinking slowly ON Blinking slowly Blinking fast AC Input Voltage is within operation range Over/under voltage Output current 033 % Output current 3366 % Output current 66100 % Over/under voltage Over Temperature Fan fail Communication error / no communication PARAMETER DESCRIPTION / CONDITION CRITERION Insulation Safety Standards Input to output: Input to chassis: Output to chassis: Signals to chassis: Latest edition of the following standards: CSA/UL609501, EN609501 and IEC609501 1.5 kvac (factory tested) 1 1.5 kvac 353 VAC 177 VAC Radiated Emission EN55011 Class A Conducted Emissions EN55011 Class A IMMUNITY REQUIREMENTS Electrostatic Discharge EN6100042 Level 4: ±6 kv contact, ±8 kv air Criterion B Radiated Electromagnetic Field EN6100043 80 6000 MHz Criterion A Electrical Fast Transient (EFT)/Burst EN6100044 Level 3: ±2 kv Criterion A Surge Immunity EN6100045 Level 3: ±1 kv DM, ±2 kv CM Criterion B RF Conducted Immunity EN6100046 Level 3: 10 Vac, 0.15 80 MHz Criterion A >5 years life at ambient temperature of +55 C Useful Life Assessment >10 years of predicted electrolytic capacitor life at TA = 55 C of and 100% load. 1 According to IEC/EN 60950 subassemblies connecting input to output are pretested with 3 kvac tech.support@psbel.com

4 TXP3500/4000 Series PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Humidity Operating range according IEC 60068278 10 90 RH Operating Temperature Ambient air temperature 25 +55 C Storage Temperature 40 +85 C PARAMETER Input Connector Output Connector Signal Input / Output Connector DESCRIPTION / CONDITION 4pin, Pitch 7.62 mm (Weidmüller 1081850000, see Fig.1) Bus bars, screw size M4, see Fig.1 15pin DSUB Male / Female (ETEC, SDD1515295FMS; see Fig.1) Figure 1. Rear View Connector Positions 8.1 INPUT POWER : PINOUT NAME PIN # TYPE RECOMMENDED WIRES Earth Earth / Chassis Min. 2.5 mm 2 AC Line 1 L1 Input Power AC Fused Min. 2.5 mm 2 AC Line 2 L2 Input Power AC Fused Min. 2.5 mm 2 AC Line 3 L3 Input Power AC Fused Min. 2.5 mm 2 528 Vrms (line to line) 16 Arms (per line) Connector type: Weidmüller 1081850000 Mating part: Weidmüller 1173520000 AsiaPacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 2018 Bel Power Solutions & Protection BCD.00684_AC

TXP3500/4000 Series 5 8.2 POWER : +/ BUS BARS NAME PIN # TYPE REFERENCE LOW LEVEL HIGH LEVEL Vout+ + Output Power DC Vout 50 / 137. Vout Output Power DC 73 / 36.5 ADC Connector type: Mating part: Busbar see Fig.1 Ring terminal for M4 screw, with appropriate cross section for wire. 8.3 INPUT : PINOUT NAME PIN # TYPE REFERENCE RS485A 1 RS485 Half Duplex, Differential pair RS485B CAN_H 2 CAN Bus CAN_L LOW LEVEL HIGH LEVEL +/60 ma @ 60 Ω, 0 pf 2 7 to 12 VDC 8 ma 27 to 40 VDC RESERVED 3 Do not connect IN OK 4 OUT OK 5 INHIBIT 6 ENABLE 7 AC Power Fail Warning open collector, low by fail Output Voltage Fault open collector, low by fail Output Inhibit Open circuit or High to shuts OFF Vout Power Supply Enable pin for unit enable short this pin to >2. >2. 1 8 Digital Ground / Return RS485B 9 RS485 Half Duplex, Differential pair RS485A CAN_L 10 CAN Bus CAN_H +/60 ma @ 60 Ω, 50 pf 2 7 to 12 VDC 8 ma 27 to 40 VDC N.C. 11 Do not connect OT/FAIL 12 PSPRESENT 13 Over Temperature / PSU Fail open collector, low by fail Power Supply Seated signal internally connected through 10 Ohm resistor to 1 VDC 100 ma N.C. 14 Do not connect N.C. 15 Do not connect 1 and SRTN / Vout are galvanically separated, SRTN and Vout are internally connected together 2 Connect 120 Ω resistors between RS485A and RS485B on both sides of the line externally Connector type: ETEC, SDD1515295FMS Mating part: Würth Elektronik, 61801529321 tech.support@psbel.com

6 TXP3500/4000 Series 8.4 : PINOUT NAME PIN # TYPE REFERENCE RS485A 1 RS485 Half Duplex, Differential pair RS485B CAN_H 2 CAN Bus CAN_L LOW LEVEL HIGH LEVEL +/60 ma @ 60 Ω, 50 pf 2 7 to 12 VDC 8 ma 27 to 40 VDC RESERVED 3 Do not connect IN OK 4 OUT OK 5 INHIBIT 6 ENABLE_MULTI 7 AC Power Fail Warning open collector, low by fail Output Voltage Fault open collector, low by fail Output Inhibit Open circuit or High to shuts OFF Vout Power Supply Enable pin for all units enable (in serial or parallel operation) >2. >2. 1 8 Signal Return RS485B 9 RS485 Half Duplex, Differential pair RS485A CAN_L 10 CAN Bus CAN_H +/60 ma @ 60 Ω, 50 pf 2 7 to 12 VDC 8 ma 27 to 40 VDC N.C. 11 Do not connect OT/FAIL 12 PSPRESENT OUT 13 Over Temperature / PSU Fail open collector, low by fail Power Supply Seated last unit in a string will pull down this signal (external short to ) and informs the Master Controller that all units in the string are seated and connected N.C. 14 Do not connect N.C. 15 Do not connect 1 and SRTN / Vout are galvanically separated, SRTN and Vout are internally connected together 2 Connect 120 Ω resistors between RS485A and RS485B on both sides of the line externally Connector type: ETEC, SDD1515295FMS Mating part: Würth Elektronik, 61801529221 8.5 SENSE/AUX/MARGIN/ACS LINES INPUT/ : PINOUT NAME PIN # TYPE SENSE+ 1 SENSE 2 Sense line for Vout+ voltage drop compensation for positive pole Sense line for Vout voltage drop compensation for negative pole REFERENCE +Vaux 3 Auxiliary output voltage SRTN LOW LEVEL HIGH LEVEL 12.1 11.8 SRTN 1 4 Return for +Vaux, Margin, ACS MARGIN 5 Adjust output voltage by ext. resistor connected between this pin and GND SRTN ACS 6 Active Current Share SRTN 1 SRTN and Vout are internally connected together 0 Ohms 37k Ohms 0.2 VDC 5.0 VDC 0.8 ADC 7 VDC 0.7 ma Connector type: Mating part: Phoenix Contact, MC 1.5/ 2G3.81 Phoenix Contact, MC 1.5/ 2ST3.81 AsiaPacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 2018 Bel Power Solutions & Protection BCD.00684_AC

TXP3500/4000 Series 7 8.6 DIP SWITCH FUNCTION SWITCH 1 ADR0 SWITCH 2 ADR1 SWITCH 3 ADR2 UNIT ADDRESS (hex/dec) OFF OFF OFF 0xB7 183 ON OFF OFF 0xB6 182 OFF ON OFF 0xB5 181 ON ON OFF 0xB4 180 OFF OFF ON 0xB3 179 ON OFF ON 0xB2 178 OFF ON ON 0xB1 177 ON ON ON 0xB0 176 SWITCH 4 SPEED SEL1 SWITCH 5 SPEED SEL2 SWITCH 6 RS485/CAN RS485 BUS SPEED [baud] CAN BUS SPEED [baud] OFF OFF OFF 460 800 ON OFF OFF 115 200 OFF ON OFF 19 200 ON ON OFF 9 600 OFF OFF ON 1 000 000 ON OFF ON 500 000 OFF ON ON 250 000 ON ON ON 125 000 8.7 PARALLEL OPERATION In case of parallel operation all SENSE/AUX/MARGIN/ACS connectors of units in parallel (pins 1, 2, 4, 6) need to be interconnected: LOAD TXPXX001XXXG Unit 1 Vout 8 VS 2 TXPXX001XXXG Unit 2 Vout 8 VS 2 TXPXX001XXXG Unit 8 Vout 8 VS 2 Figure 2. Parallel Operation Schematic CAUTION: DO NOT connect neither two different models nor same model units, when they have a different output voltage setting, together in parallel! tech.support@psbel.com

8 TXP3500/4000 Series 8.8 SERIAL OPERATION CAUTION: In case of serial operation the pins SRTN of particular units must not be connected together! LOAD + TXPXX001XXXG Unit 1 Vout 8 VS 2 TXPXX001XXXG Unit 2 Vout 8 VS 2 TXPXX001XXXG Unit 4 Vout 8 VS 2 Figure 3. Serial Operation Schematic PARAMETER Dimensions (W x H x D) Weight Cooling Enclosure CONDITIONS / DESCRIPTION 135 x 85 (2U) x 465 mm (see Fig.4) 6.5 kg (single PSU) Externally accessible serviceable fan IP20 Figure 4. Mechanical Dimensions AsiaPacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 2018 Bel Power Solutions & Protection BCD.00684_AC

TXP3500/4000 Series 9 NUCLEAR AND MEDICAL APPLICATIONS Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com