Quick Installation Manual

Similar documents
Indicator (Square) Ultra Bright LED Type

Saving a location and and restarting it it on on the the CX-Programmer. Existing the CX-Designer and restarting. Editing a screen on the CX-Designer

Indicator (Square) Ultra Bright LED Type

F3SG-RA. Safety Light Curtain. Advanced Safety Light Curtain in Rugged, IP67 Rated Housing. Online. Blanking

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Digital Temperature Controllers E5 C Series

F3SL. Safety Light Curtain for Long Distance Detection

F39-BT Bluetooth Communication Unit. F39-BTLP Lamp and Bluetooth Communication Unit. F39-JD B Double-Ended Cable *1. F39-JGR2W Cascading Cable *1

Sockets, Slim I/O Relays, I/O Relay Terminals

DIN Track Terminal Blocks XW5T

E2CY-SD. Proximity Sensor with Separate Amplifier Unit for Detection of Non-ferrous Metals with Simple Sensitivity Adjustment

Safety Light Curtain. F3SG- R Series. User's Manual. Cat. No. Z352-E1-08.

Pushbutton Switches. A22N-P/A30N-P (Pushbutton Switches, Selector Switches) M22N-P (Indicators) A22NE-P (Emergency Stop Switch)

Switch Mode Power Supplies S8VK-X. IoT Production Site Innovation

Viper 650/850 eplc. Quick Setup Guide I600-E-01

MEASURING AND MONITORING RELAYS

F3ET Lightcurtain in robust aluminium housing

Three-phase Voltage Relay

Radically Increase the Performance of Multipoint Temperature Control with the EJ1.

Cobra 350 eplc Robot. Quick Setup Guide I592-E-01

E5_C-T Programmable Temperature Controller (Digital Controller)

UMA Series. Safety Mat. Easy-to-install safety mat with advanced features Model Number Structure

FA Communications Software

2D Code Reader V400-F

Electronic Thermostat

F3SJ Series. EASY type simple and affordable hand protection. Safety Light Curtain. BASIC type simple hand protection and simple muting functions

Number of input channels

Solid-state timer Compact, Multi-function Timers for G2R Relay Socket. Model Number Structure. Ordering Information. Model Number Legend

Safety Laser Scanner OS3101

Measuring and Monitoring Relays K8DT

F3EM Measuring lightcurtain in robust aluminium housing

OMRON TM COLLABORATIVE ROBOT

Photoelectric Sensor

Durable Space-saving Advanced

Electronic Thermostat

Switch Mode Power Supplies S8VK-X. IoT Production Site Innovation

8000 Series: Installation Supplement R2-1-12

D40Z. Versatile applications. Compact Non-contact Door Switch. Wide range of applications at the highest safety level

CX-Process Monitor Plus Ver. 2.0

Programmable Multi Axis Controller CK3M

CX-Process Tool INTRODUCTION GUIDE

T4HD: Installation Supplement R8.1.13

E5_N/E5_N-H Digital Temperature Controllers

Plateau Head Knob-type Selector Switch

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

Three-phase Voltage Relay

MEASURING AND MONITORING RELAYS

D40Z. Versatile applications. Compact Non-contact Door Switch. Wide range of applications at the highest safety level

Control Panel Basics Volume 2

SF4C. Instruction Manual

USB-Serial Conversion Cable User's Manual

FA Integrated Tool Package. CX-One. Ver. 2.0 CXONE-AL C-EV2/-AL D-EV2. Greater Integration with CX-One Version 2.0

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ

Three Intuitive, Easy-to-use Indicators

Single-phase Voltage Relay

NX1 Machine Automation Controller Continue to pursue productivity

Safety Mat / Safety Mat Controller UM/MC3. Stay one step ahead in safety

Compact Non-contact Door Switch D40Z. Wide range of applications at the highest safety level

Single-phase Overvoltage/Undervoltage Relay

EE-SX95. Meeting Customer Needs with Ultracompact Sensors that Mount with M3 Screws. Ultra-compact Pre-wired Photomicrosensor (Non-modulated) Features

Conductive Level Controller

F3SJ-A F3SJ-A. Safety Light Curtain. safety light curtain that. Options. software. The F3SJ-A system is a fullfeatured

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

NJ/NX-series Machine Automation Controller Database Connection CPU Unit

New Value For Control Panels. Innovation in Control Panel Building

Miniature Inductive Prox TL-W

Safety Monitoring Relays

DIN Track Mounted, Standard 22.5-mm Width Timer Range

Collaborative Robots TM5

Authorized Distributor: OMRON Industrial Automation Global:

Photoelectric Sensor. Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Sensor

Conductive Level Controller

Omron Adept Technologies,Inc.

Safety Relay Unit G9SE Series

E3S-DC. Color Mark Photoelectric Sensor

SAFETY DEVICES SE4-R SERIES. SAFEasy TYPE 4 LIGHT CURTAINS

Safety Relay Unit G9SE Series

G9SX-SM Sensor-less Monitoring of Standstill for Machines with Long Inertia

SmartVision MX. Userʼs Guide I608-E-01

MEASURING AND MONITORING RELAYS

Data Reference Manual

Sysmac Library Omron's control expertise changes programming

Classification Applicable models Specification Type Model

Instruction Manual SF4B- C. Compact Light Curtain / Type 4. Phone: Fax: Web: -

Machine Automation Controller NX1P

Safety Relay Unit (I/O Unit Type)

OS3101. Operator Presence Detection in Work Areas with Complex Shapes. Safety Laser Scanner. Ordering Information. Safety/Area.

ACCESSORIES FOR SAFETY DEVICES

3D Vision Sensor FZD Series

Number of optical axis

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

OptoFence. OptoFence OF OF safety light curtains. Description

Photoelectric Sensor

Through-beam pre-wired E3F1-TN11 2M *1 E3F1-TP11 2M *1 15 m. pre-wired E3F1-RN11 2M E3F1-RP11 2M 0.1 to 3 m

SEN TRONIC AG WARNING. QUICK INSTRUCTION MANUAL Compact Light Curtain / Type 4 SF4B- C 1 SAFETY PRECAUTIONS 2 CONFIRMATION OF PACKED CONTENTS

SMARTSCAN INFORMATION

Machine Automation Controller NJ Series

Introducing Hex-shaped Models with Build-in Lenses

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

Transcription:

Safety Light Curtain F3SG- RA Series http://www.ia.omron.com/f3sg-r Document Title Safty Light Curtain F3SG-R Series User's Manual Cat. No. Z352-E1 OMRON Corporation 2014-2016 All Rights Reserved. Original instructions 7999687-9D

Introduction Thank you for purchasing the Series Safety Light Curtain (hereinafter referred to as the "F3SG- RA"). This document contains simple instructions to install the. Please download the User's Manual for full contents of the instructions from our website at: http://www.ia.omron.com/f3sg-r Table of Contents 1. What is Included...1 2. System Components...2 3. Setup Procedure Example...2 4. Setting with DIP Switch...3 5. Examples...4 5-1. EDM disabled, Auto Reset Mode, External Test disabled, Muting disabled and PNP Outputs..4 5-2. EDM enabled, Manual Reset Mode, External Test in 24 V Active, Muting enabled and PNP Outputs...4 5-3. EDM disabled, Auto Reset Mode, External Test disabled, Muting disabled and NPN Outputs..5 5-4. EDM enabled, Manual Reset Mode, External Test in 0 V Active, Muting enabled and NPN Outputs...5 6. Mounting and Beam Alignment...6 6-1. Mounting with Standard Fixed Brackets (F39-LGF)...6 6-2. Mounting with Standard Adjustable Brackets (F39-LGA)...8 7. Operation Check...11 Suitability for Use/Contact Information...11 1. What is Included Product main unit x 1, Receiver x 1 Quantity Factory Default Settings Feature External Test Interlock EDM (External Device Monitoring) Auxiliary Output Muting Override Factory Default Setting 24 V Active Auto Reset Mode enabled Disabled Safety output information (Inverted signal output: Enable) Standard Muting Mode enabled Enabled Refer to F3SG-R Series User's Manual for more information. Standard Fixed Bracket The number of brackets included depends on protective height of the. Less than 1,280 mm: 2 sets 1,280 mm or longer and up to 2,270 mm: 3 sets 2,350 mm or longer and up to 2,510 mm: 4 sets Warning Zone Label 1 Troubleshooting Guide Sticker 1 Safety Precautions 4 1 For ratings/specifications, input/output circuit, LED indicator status and troubleshooting, refer to Safety Light Curtain F3SG-R Series User's Manual. 1

2. System Components Beam center-line mark <> <Receiver> DIP Switch () Beam Indicator Power Cable (Gray) Extension cable Receiver DIP Switch (Receiver) Push-Switch Power Cable Communication Port (Black) 1. Test indicator (Green) 2. Operating range indicator (Green) 3. Power indicator (Green) 4. Lockout indicator (Red) 1. Top-beam-state indicator (Blue) 2. PNP/NPN mode indicator (Green) 3. Response time indicator (Green) 4. Sequence error indicator (Yellow) 5. Blanking indicator (Green) 6. Configuration indicator (Green) 7. Interlock indicator (Yellow) 8. External device monitoring indicator (Green) 9. Internal error indicator (Red) 10. Lockout indicator (Red) 11. Stable-state indicator (Green) 12. ON/OFF indicator (Green/Red) 13. Communication indicator (Green) 14. Bottom-beam-state indicator (Blue) 3. Setup Procedure Example Setup Setting with DIP Switch*...... page 3...... page 4...... page 6...... page 11 Done * Setting with DIP Switch may be necessary according to your application. For settings with Configuration Tool and by teach-in, refer to Safety Light Curtain F3SG-R Series User's Manual. 2

4. Setting with DIP Switch Step 1 Step 2 Step 3 DIP Switch Receiver 1 O 1 O 2 N 2 N 3 4 5 6 7 8 3 4 5 6 7 8 1 O N 2 3 4 Screw(M2.5) Screw(M2.5) Tightening torque: 0.35 N m (recommended) Open the cover Change the settings (See below) Close the cover Position Function 1 Scan Code 2 External Device Monitoring (EDM) Setting DIP-SW1 DIP-SW2 Factory default setting : Indicates a switch position. Scan Code A Description Scan Code B External Device Monitoring (EDM) Disabled External Device Monitoring (EDM) Enabled Receiver 3, 4 Interlock/Pre-Reset Auto Reset Manual Reset (Start/Restart Interlock) Pre-Reset Auto Reset (same as factory default setting) Blanking Disabled 5, 6 Fixed Blanking/ Floating Blanking 7 PNP/NPN Selection 8 DIP Switch/ Configuration Tool Selection 1 Scan Code Fixed Blanking Enabled Floating Blanking Enabled Blanking Disabled (Same as Blanking Disabled (factory default setting)) PNP NPN DIP Switch Enabled Configuration Tool Enabled Scan Code A Scan Code B Short Mode 2, 3 Operating Range Selection Setting Inhibited Setting Inhibited Long Mode 4 External Test 24 V Active 0 V Active The receiver has two DIP Switches, both of which must be configured based on the table above. 3

5. Examples For input/output circuit and other examples than below, refer to Safety Light Curtain F3SG-R Series User's Manual. 5-1. EDM disabled, Auto Reset Mode, External Test disabled, Muting disabled and PNP Outputs Not used: White Receiver F39-JG A-L F39-JG A-D [DIP Switch settings] *1 Not used: Yellow TEST: Black RESET: Yellow MUTE A: Gray MUTE B: Pink AU: Red OSSD1: Black OSSD2: White Function EDM Disabled (factory default setting) Receiver Auto Reset (factory default setting) PNP (factory default setting) External Test: 24 V Active (factory default setting) +24 VDC Power Supply *1. The functions are configurable with DIP Switch. Refer to 4. Setting with DIP Switch for more information. *2. Refer to Safety Light Curtain F3SG-R Series User's Manual for more information. *3. The safety controller and the must share the power supply or be connected to the common terminal of the power supply. Safety Controller *2 *3 5-2. EDM enabled, Manual Reset Mode, External Test in 24 V Active, Muting enabled and PNP Outputs Not used: White Not used: Yellow F39-JG A-L S1 TEST: Black S2 *3 RESET: Yellow *2 S3 F39-JG A-D MUTE A: Gray S4 Receiver MUTE B: Pink S5 AU: Red OSSD1: Black IN1 KM1 OSSD2: White IN2 KM2 0 VDC [DIP Switch settings] *1 Function EDM Enabled Receiver Manual Reset PNP (factory default setting) External Test: 24 V Active (factory default setting) +24 VDC Power Supply 0 VDC KM1 KM2 M KM1 KM2 IN PLC *4 S1: Test Switch (Connect the line to 0 V if this switch is not required) S2: Override Cancel Switch S3: Lockout/Interlock Reset Switch or Override Switch S4, S5: Muting sensor KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: 3-phase motor PLC: Programmable controller (Used for monitoring only. NOT related to safety system.) *1. The functions are configurable with DIP Switch. Refer to 4. Setting with DIP Switch for more information. *2. Also used as Override input line. *3. Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury. *4. When connecting to the PLC, the output mode must be changed with the Configuration Tool according to your application. 4

5-3. EDM disabled, Auto Reset Mode, External Test disabled, Muting disabled and NPN Outputs F39-JG A-L F39-JG A-D Receiver [DIP Switch settings] *1 Function EDM Disabled (factory default setting) Receiver Auto Reset (factory default setting) NPN External Test: 0 V Active Not used: White Not used: Yellow TEST: Black RESET: Yellow MUTE A: Gray MUTE B: Pink AU: Red OSSD1: Black OSSD2: White *1. The functions are configurable with DIP Switch. Refer to 4. Setting with DIP Switch for more information. *2. Refer to Safety Light Curtain F3SG-R Series User s Manual for more information. *3. The safety controller and the must share the power supply or be connected to the common terminal of the power supply. IN1 IN2 Safety Controller *2 *3 +24 VDC Power Supply 0 VDC 5-4. EDM enabled, Manual Reset Mode, External Test in 0 V Active, Muting enabled and NPN Outputs F39-JG A-L F39-JG A-D [DIP Switch settings] *1 Function EDM Enabled Receiver Manual Reset NPN External Test: 0 V Active Not used: White Not used: Yellow TEST: Black RESET: Yellow *2 MUTE A: Gray MUTE B: Pink AU: Red OSSD1: Black OSSD2: White KM1 KM2 S1 S2 *3 S3 M KM1 KM2 S1: Test Switch (Connect the line to 24 V if this switch is not required) S2: Override Cancel Switch S3: Lockout/Interlock Reset Switch or Override Switch S4, S5: Muting sensor KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: 3-phase motor PLC: Programmable controller (Used for monitoring only. NOT related to safety system.) *1. The functions are configurable with DIP Switch. Refer to 4. Setting with DIP Switch for more information. *2. Also used as Override input line. *3. Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury. *4. When connecting to the PLC, the output mode must be changed with the Configuration Tool according to your application. 5

6. Mounting and Beam Alignment 6-1. Mounting with Standard Fixed Brackets (F39-LGF) Dimensions (Check position) [Backside mounting] Step1 Check position 50.35 Step2 Mount 40 35 35 Standard Fixed Bracket (F39-LGF) 2-M5 or M6 Standard Fixed Bracket (F39-LGF) F 66 51 D A 6.4 C2 (Protective height for 14mm) C1 (Protective height for 30mm) 51 51 F A 9.2 24.85 P 2-M5 or M6 24.85 43 33 18 < Screw: M5 or M6 > [ Unit : mm ] -30 Series Dimension A C1+18 Dimension C1 4-digit number of the type name (Protective height) Dimension D C1-50 Dimension P 20-14 Series Dimension A C2+48 Dimension C2 4-digit number of the type name (Protective height) Dimension D C2-20 Dimension P 10 Protective height (C1) Number of Standard Fixed Brackets *1 Dimension F 0190 to 1230 2 *2 1000 mm max. 1310 to 2270 3 1000 mm max. 2350 to 2510 4 1000 mm max. Protective height (C2) Number of Standard Fixed Brackets *1 Dimension F 0160 to 1200 2 *2 1000 mm max. 1280 to 2080 3 1000 mm max. *1. The number of brackets required to mount either one of emitter and receiver. *2. Mounting an emitter or receiver with one bracket is possible for the models of protective height of 0160 to 0270. In this case, locate this bracket at half the Dimension A (or at the center of the sensor length). Refer to Safety Light Curtain F3SG-R Series User's Manual for dimensions of side mounting. 6

Mounting 1. Loosen the screw. Step1 Check position Hexagon socket head cap screw (M3 x 15) Fixed Bracket Step2 hook Mount 2. Lightely tighten the screw. Optical surface of Optical surface of Slide the hook in the groove Fixed Bracket Fixed Bracket Slide the hook in the groove 3. Adjust the mounting position and secure the bracket. Adjust the bracket to mounting position Adjust the bracket to mounting position Tightening torque: 2.0 N m (recommended) 4. Secure the bracket to the wall. Screws to mount the brackets to the wall are not included. 7

6-2. Mounting with Standard Adjustable Brackets (F39-LGA) Dimensions (Check position) [Backside mounting] 50.35 Step1 Check position 48.6 35 35 Step2 Mount Standard Adjustable Bracket (F39-LGA) 2-M5 or M6 Step3 Align beams Standard Adjustable Bracket (F39-LGA) F 84 72 D C2 (Protective height for 14mm) C1 (Protective height for 30mm) A F A 6.4 72 72 9.2 24.85 P 2-M5 or M6 24.85 43 33 18 < Screw: M5 or M6 > [ Unit : mm ] -30 Series Dimension A C1+18 Dimension C1 4-digit number of the type name (Protective height) Dimension D C1-50 Dimension P 20-14 Series Dimension A C2+48 Dimension C2 4-digit number of the type name (Protective height) Dimension D C2-20 Dimension P 10 Protective height (C1) Number of Standard Adjustable Brackets *1 Dimension F 0190 to 1230 2 *2 1000 mm max. 1310 to 2270 3 1000 mm max. 2350 to 2510 4 1000 mm max. Protective height (C2) Number of Standard Adjustable Brackets *1 Dimension F 0160 to 1200 2 *2 1000 mm max. 1280 to 2080 3 1000 mm max. *1. The number of brackets required to mount either one of emitter and receiver. *2. Mounting an emitter or receiver with one bracket is possible for the models of protective height of 0160 to 0270. In this case, locate this bracket at half the Dimension A (or at the center of the sensor length). Refer to Safety Light Curtain F3SG-R Series User's Manual for dimensions of side mounting. 8

Step1 Check position Mounting and Beam Alignment 1. Loosen the screws and adjust the angle. hexagon socket head cap screw (M3 x 15) hexagon socket head cap screw (M3 x 15) hook Step2 Mount Step3 Align beams 2. Lightely tighten the screw. Optical surface of Optical surface of Slide the hook in the groove Adjustable Bracket Slide the hook in the groove 3. Adjust the mounting position and secure the bracket. Adjustable Bracket Adjust the bracket to mounting position Adjust the bracket to mounting position Tightening torque: 2.0 N m (recommended) 4. Secure the bracket to the wall. Screws to mount the brackets to the wall are not included. 9

5. Perform beam alignment according to the indicators. <> <Receiver> <Receiver> <Receiver> Step1 TOP(Blue) TOP(Blue) Check position Step2 Mount STB(Green) STB(Green) Step3 BTM(Blue) BTM(Blue) Align beams Angle adjustment range: ±15 6. Securely tighten the remaining screws. Tightening torque: 2.0 N m (recommended) <Enlarged view> Hexagon socket head cap screw (M3x15) 10

For more information, visit http://www.ia.omron.com/f3sg-r Setting with DIP Switch 7. Operation Check After setting with DIP Switch, wiring, mounting and beam alignment are done, check the operation of the. Attach the included Troubleshooting Guide Sticker nearby, if necessary. TROUBLESHOOTING [EN] Blinking OFF LED INDICATOR TOP BLANK CFG LOCKOUT EDM INTERNAL Blinking Once ON/OFF COM BTM or LONG POWER LOCKOUT ON/OFF, COM, or INTERNAL Blinking Twice POWER LOCKOUT STB SEQ MAJOR CAUSE Cap is not attached. Error of other F3SG in cascade. Error is detected due to Blanking Monitoring Error of model combination in cascade Error of EDM Error of internal circuit Error of OSSD lines Error of communication Error of DIP-SW setting Error of emitter Error due to abnormal power supply or noise Error due to noise Error due to vibration or ambient light Wrong sequence of Muting or Interlock input 9600184-8A(5) Refer to Safety Light Curtain F3SG-R Series User's Manual or the website for troubleshooting. http://www.ia.omron.com/f3sg-r Suitability for Use Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. See also Product catalog for Warranty and Limitation of Liability. OMRON Corporation Suitability for Use/Contact Information Industrial Automation Company (Manufacturer) Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. (Representative and Importer in EU) OMRON ASIA PACIFIC PTE. LTD. Wegalaan 67-69, NL-2132 JD Hoofddorp No. 438A Alexandra Road # 05-05/08 (Lobby 2), THE NETHERLANDS Alexandra Technopark, Tel: (31)-2356-81-300 / FA: (31)-2356-81-388 Singapore 119967 Tel: (65) 6835-3011 / Fax: (65) 6835-2711 OMRON SCIENTIFIC TECHNOLOGIES INC. OMRON (CHINA) CO., LTD. 6550 Dumbarton Circle Room 2211, Bank of China Tower, Fremont, CA 94555 U.S.A. 200 Yin Cheng Zhong Road, Tel: (1) 510-608-3400 / Fax: (1) 510-744-1442 PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222 / Fax: (86) 21-5037-2200 In the interest of product improvement, specifications are subject to change without notice. 11