Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

Similar documents
100% electricity. Power factor correction components

AUTOMATIC POWER FACTOR CONTROLLERS AND THYRISTOR MODULES 23

100% electricity. Automatic transfer switch controllers ATL series

Page Backlight graphic display, 128x80 pixels. Optic interface port for programming, data download and diagnostics

Page measurement up to 15th order Front optical USB and Wi-Fi communication port for PC, smartphone and tablet connection

Motor protection relays

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

SOFT STARTERS PLANET -LOGIC

E N E R G Y M E T E R S

DIGITAL METERING INSTRUMENTS DMG SERIES

Digital multimeters DMG

Expansion modules and accessories

MOTOR PROTECTION CIRCUIT BREAKERS

Page Page Page ACCESSORIES Communication devices Remote display unit Protective covers Converters Gateway Connecting cables.

ENGINE, GENERATOR AND ATS CONTROLLERS. Engine Protection Controllers p18-1

Istruzioni per l uso. Operating instructions. Bedienungsanleintung. Notice d utilisation. Instrucciones de uso

Switches Unlimited Contact: Phone: * Fax:

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL

Automatic Power Factor Controllers Thyristor Modules p17-7

VARIABLE SPEED DRIVES

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

MOTOR & CIRCUIT PROTECTION

ENERGY AND AUTOMATION

Page 5-3. Page 5-2 Page 5-3

DCRJ8 DCRJ12 Automatic power factor regulator

with Backlight Graphic LCD Screen

Products and solutions for generating sets

DATA SHEET Selectable AC transducer, TAS-331DG

Rapidus Power Factor Controller

Engine and generator controllers

Digital metering instruments and current transformers

GCR 06, GCR 12. Power factor correction controller. User and service manual

POWER FACTOR REGULATOR

ES Energy Saver Product Ranges 90Amp 6000Amp

100% electricity. Programmable logic relays

A2000 Multifunctional Power Meter

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

100% electricity. Automatic transfer switch controllers ATL series

MIC-2 Multi-instrument DATA SHEET

E 1. SPECOM - Network analyser. Content. E.2 Description. E.3 Specom C - Technical data. E.4 Specom M - Technical data. E.5 Data communication

Metering instruments and current transformers

Motor protection circuit breakers

Quality touch! Pushbuttons and selector switches. series

ENGINE AND GENERATOR CONTROLLERS

3 Pole Contactors with AC operating coils

PFC-10 Power Factor Controller

Reactive power regulators and protections

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

For Info: Phone: Fax:

MIC-2 MKII, Multi-instrument DATA SHEET

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

HMI HUMAN MACHINE INTERFACE

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

Energy Management Solutions

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

MI 2792A PowerQ4 Plus

DATA SHEET Selectable AC transducer, TAS-321 DG

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

ahead of time Voltage Stabilisers

VARIABLE SPEED DRIVES VLA1 SERIES

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Tesseract. Technical Data sheet

PQM - Power Quality Monitoring

DIGITAL LCD MULTIMETERS AND POWER ANALYZERS Graphic LCD or touch screen Remote display Expandable versions.

Products and solutions for machine builders (OEM)

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Process controllers for the meat processing industry

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

Type ADXC... 2 phase control Type ADXL... 2 phase control Type ADX... 3 phase control Accessories Software...

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

AND COMMUNICATION MODULES

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

TeSys contactors From 115 to 2750 A

Mini Contactors & Overloads

Features. Description. Applications

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

EM2020 Selectable AC transducer A (UK)

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Quick Start Installation Guide

Micro Contactor MA Series

Voltage Dip-Proofing Inverter

Page Page 23-17

Three-Phase Power Quality Analyzer PowerPad Model 3945

Transcription:

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC 100% ity

Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration in 144x144mm housing Capacitor overload protection Internal overheating protection TTL/RS232 serial port Automatic set-up function (adjustable) Configurable alarms. DCRJ Digital programming 8 or 12 step configurationin 144x144mm housing Separate voltage measurement input Capacitor overload protection Internal-external overheating protection RS232 programming and suvision interface RS485 suvision interface Automatic set-up function (adjustable) Configurable alarms Voltage and current harmonics measurement Event log Suitable for medium voltage systems. DESCRIPTION DCRK DCRJ Front plate 3-digit display 4-digit display supplement 4 oation keys 1 function key 7 LED indicators for main functions and measurements 14 LED indicators for main functions and measurements Control - Functions Automatic recognition of current flow 4-quadrant oation Separate voltage input Three-phase voltage control Medium-voltage usage Phase-Neutral connection in 3-phase systems Programmable input as functional or remote tem sensor Keypad lock TTL/RS232 communication interface RS232 communication interface Isolated RS485 communication interface Automatic set-up function (adjustable) Easy current transformer setting function Set-up and automatic panel test software Remote suvision software Real time clock with back-up battery Current and voltage waveform captures, related to harmonic events Events logging such as: alarms, power ON, power OFF, set-up changes, etc. Measurements Instantaneous displacement power factor (cosϕ) Instantaneous and average weekly power factor Voltage and current Reactive power to reach set-point value Total reactive power Capacitor overload Electric panel temature Maximum voltage and current value Maximum capacitor overload value Maximum panel temature value Maximum capacitor temature value Active and apparent power Current and voltage harmonic analysis Current and voltage harmonic waveform logged at overload events Step var value Number of switching step Protections Voltage too high and too low Current too high and too low Over compensation (capacitors disconnected and Cosϕ higher than set-point) Under compensation (capacitors connected and Cosϕ lower than set-point) Capacitor overload Capacitor overload on all 3 phases Over temature No-voltage release protection Capacitor bank failure Over maximum harmonic distortion level limit Programmable alarm proties (enable, trip delay, relay energising, etc.) 2

Automatic power factor regulators DCRK series DCRK 5 - DCRK 7 DCRK 8 - DCRK 12 Order code Steps Flush-mount Qty Weight housing size pkg n [mm] n [kg] DCRK 5 5 96x96 1 0.365 DCRK 7 7 96x96 1 0.375 DCRK 8 8 144x144 1 0.640 DCRK 12 12 144x144 1 0.660 Software Example of main window frame using DCRK SW software Order code Description Qty Weight pkg n [kg] DCRK SW Set-up and automatic 1 0.246 test software complete with cable 51 C11 Accessories and spare parts 51 C11 PC DCRK connecting 1 0.090 cable for TTL/RS232 communication port, 2.8 m long 31 PACR Front protective cover for 1 0.107 DCRK8 and DCRK12 types, IP54 General characteristics Digital microprocessor regulator for automatic power factor correction systems with output relays for the connection and disconnection of capacitor banks 5, 7, 8 and 12 step versions, the last two of which are programmable as alarm and/or fan control For co-generation systems; 4 quadrant oation Accurate and reliable power factor control of a system even in presence of high current and voltage harmonic content Warrants optimal capacitor use for increased life by the rational control of the capacitor oation and connection time RMS voltage and current measurements Average weekly power factor measurement (last 7 days) Adjustable tripping sensitivity, integral switching time Adjustable reconnection time delay No-voltage release protection Protection against capacitor overload and panel overheating Automatic set-up function (adjustable) TTL-RS232 interface with sonal computer for: fast set-up, function and alarm customising and automatic panel testing. Oational characteristics Voltage circuit Supply and control voltage Ue: 380-415VAC standard; 220-240VAC or 415-440VAC on request Rated frequency: 50/60Hz ±1% self configurable Power consumption: 6.2VA (DCRK5 and DCRK7) 5VA (DCRK8 and DCRK12) Current circuit Rated current Ie: 5A (1A on request) Oation range: 0.125-6A Overload peak: 20Ie for 10ms Power consumption: 0.65W Measurements and controls Power factor adjustment: 0.8 inductive - 0.8 capacitive Voltage measurement range: -15 to +10% Ue Current measurement range: 2.5 to 120% Ie Temature measurement range: -30...+85 C Capacitor overload current range: 0-250% Type of voltage and current measurement: RMS Reconnection time of same step: 5-240s Tripping sensitivity: 5-600s/step Output relays 5, 7, 8 or 12 steps, the last of which is isolated Contact configuration: Normally Open (NO); the last contact of DCRK8-DCRK12 is a changeover type Rated current Ith: 5A 250VAC (AC1) Maximum capacity of common terminal: 12A Rated oational voltage: 250VAC IEC/EN 60947-5-1 contact designation: C/250, B/400 Maximum switchable voltage: 440VAC Housing Flush mounting Degree of protection on front: IP54 for DCRK5 and DCRK7. IP41 for DCRK8 and DCRK12 (IP54 with protective cover 31 PACR) Oating temature: -20...+60 C Connection Type of terminal: plug-in Maximum cable section: 2.5mm 2 ; AWG 12. Certifications and compliance Certifications obtained: culus. Compliant with standards: IEC/EN 61010-1, IEC/EN 61000-6-2, CISPR 11/EN 55011. 3

Automatic power factor regulators DCRJ series DCRJ 8 - DCRJ 12 Order code Steps Flush-mount Qty Weight housing size pkg n [mm] n [kg] DCRJ 8 8 144x144 1 0.940 DCRJ 12 12 144x144 1 0.980 Software Example of main window frame using DCRJ SW software Order code Description Qty Weight pkg n [kg] DCRJ SW Set-up, automatic 1 0.246 test and remote control software complete with cable 51 C2 Accessories and spare parts 51 C2 PC DCRJ connecting 1 0.090 cable, 1.8 m long 51 C4 PC 4 PX1 converter 1 0.147 drive connecting cable, 1.8 m long 51 C5 DCRJ Modem 1 0.111 connecting cable, 1.8 m long❶ 51 C6 DCRJ 4 PX1 1 0.102 converter drive connecting cable, 1.8 m long 51 C9 4 PX1 Modem 1 0.137 connecting cable, 1.8 m long 4 PX1 RS232/RS485 converter 1 0.600 drive, galvanically isolated, 220-240VAC❷ NTC 01 Temature sensor 1 0.150 31 PACR Front protective cover, 1 0.107 IP54 protection ❶ 3Com-U.S. Robotics 56k V.92 modem with RS232 interface, complete with PC connecting cable, compatible with LOVATO ELECTRIC remote control software. ❷ RS232/RS485 opto-isolated converter drive, 38,400 Baud-rate maximum, automatic or manual TRANSMIT line suvision, 220...240VAC ±10% supply (110-120VAC on request). General characteristics Digital microprocessor regulator for automatic power factor correction systems with output relays for the connection and disconnection of capacitor banks 8 and 12 step versions, the last two of which are programmable as alarm and/or fan control For medium voltage systems (separate voltage input) and co-generation (4 quadrant oation) Accurate and reliable power factor control of a system even in presence of high current and voltage harmonic content Warrants optimal capacitor use for increased life using rational control of the capacitor oation and connection time RMS voltage and current measurements Measurement of average weekly power factor (last 7 days), capacitor overload, panel temature, voltage and current harmonic content Event viewing when harmonic overload limit exceeded Harmonic content analysis of logged events complete with relative waveforms Adjustable tripping sensitivity, integral switching time Adjustable reconnection time delay No-voltage release protection Protection against capacitor overload and panel overheating Panel temature sensor Connection to remote NTC temature sensor Automatic set-up function (adjustable) One RS232 and one RS485 serial ports Remote suvision software for sonal computer interface and suvision for: fast set-up, function and alarm customising and automatic panel testing. Oational characteristics Supply circuit Dual supply voltage Ue: 110-127 / 220-240VAC Rated frequency: 50/60Hz ±5% Power consumption: 9.7VA Voltage circuit Three phases without neutral Oating range: 85-760VAC Rated frequency 50/60Hz ±5%, self configurable Current circuit Rated current Ie: 5A (1A on request) Oation range: 0.125-6A Overload peak: 20Ie for 10ms Power consumption: 0.3VA Measurements and controls Type of voltage and current measurement: RMS Voltage measurement range: 100-690VACVAC Current measurement range: 2.5 to 120% Ie Temature measurement range: -40...+85 C Capacitor overload current range: 0-250% Power factor adjustment: 0.8 inductive - 0.8 capacitive Reconnection time of same step: 5-240s Tripping sensitivity: 5-600s/step Output relays 8 or 12 steps, the last of which is isolated Contact configuration: Normally Open (NO); the last of which is a changeover type Rated current Ith: 5A 250VAC (AC1) Maximum capacity of common terminal: 12A Rated oational voltage: 250VAC IEC/EN 60947-5-1 contact designation: C/250, B/400 Maximum switchable voltage: 440VAC Housing Flush mounting Degree of protection on front: IP41; IP54 with protective cover 31 PACR. Oating temature: -20...+60 C Connection Type of terminal: plug-in Maximum cable section: 2.5mm 2 ; AWG 12. Certifications and compliance Certifications obtained: culus. Compliant with standards: IEC/EN 61010-1, IEC/EN 61000-6-2, CISPR 11/EN 55011. 4

Contactors for power factor correction with control circuit: AC BF K contactors (including limiting resistors) 11 BF..K... Order code Maximum oating Qty Wt power at ❶ 230V 400V 440V 690V pkg [kvar] [kvar] [kvar] [kvar] n [kg] AC coil. 11 BF9K 10 ❷❸ 4.5 8 9 10 10 0.490 11 BF12K 10 ❷❸ 7 12.5 14 16 10 0.490 11 BF20K 00 ❷❹ 9 15 17 20 10 0.530 11 BF25K 00 ❷❹ 11 20 22 22 10 0.530 11 BF40K 00 ❷❹ 17 30 33 36 10 0.660 11 BF50K 00 ❷❹ 22 38 41 46 5 1.440 11 BF65K 00 ❷❹ 26 45 50 56 5 1.470 11 BF80K 00 ❷❹ 34 60 65 70 5 1.470 ❶ Consult our Customer Service (Tel. +39 035 4282422) for the use of contactors to switch with delta connection. ❷ Complete order code with the coil voltage digit (if 50Hz) or with the voltage digit followed by 50 60 (if 50-60Hz frequency) or with the voltage digit followed by 60 (if 60Hz). Standard voltages are as follows: -- 50Hz 24-48-110-220-230-240-380-400-415V -- 50/60Hz 24-48-110-220-220/230 (indicate 220 230 only) - 230-240-380-380/400 (indicate 380 400 only) - 415V -- 60Hz 24-48-110-120-220-230V. Other voltages available on request. ❸ One NO auxiliary contact incorporated. ❹ No auxiliary contact incorporated. Oational characteristics Type Rated current Fuse gg [A] [A] BF9 K 12 16 BF12 K 18 25 BF20 K 23 40 BF25 K 30 40 BF40 K 43 63 BF50 K 58 80 BF65 K 70 100 BF80 K 90 125 Ambient oating temature: 50 C. For ambient tematures higher than 50 C and up to 70 C, the maximum oating power values indicated in the table must be reduced by a centage equal to the difference between the oating ambient temature and 50 C. E.g.: Using a BF25K 00 contactor at the ambient temature of 60 C, the maximum oating power (at 400V) of the contactor will be equal to 20 kvar 10% = 18 kvar. Oating cycle: 120 cycles/h. Electrical life: 200,000 cycles. Certifications and compliance Certification obtained: culus. Compliant to standards: IEC/EN 60947-4-1. Kits to assemble BF...K contactors Order code For contactor Qty Wt pkg n [kg] 11 G460 BF9 10 - BF12 10 - BF20 00 1 0.072 BF25 00 - BF40 00 11 G464 BF50 00 - BF65 00 - BF80 00 1 0.120 To optimise contactor stock management, a kit is available to transform normal three-pole contactors into BF..K types for power factor correction. The table to the left indicates which kits to purchase depending on the standard contactor in stock. 11 G46... 5

C0000071 Power factor correction components Dimensions and wiring diagrams DCRK5 - DCRK7 DCRK8 - DCRK12 DCRJ8 - DCRJ12 65 53 31 91 62 52 31 138.5 62.00 52.00 7.70 144.00 138.50 96 PA96x96 91 144 PACR 138.5 144.00 13 96 6 144 7.7 BF9K... - BF12K... BF20K... - BF25K... BF40K.. Ø 4.2 Ø 4.2 60 105~ 110 75 115~ 44 35 117.2 44 35 44 123 55 Ø4.2 40 55 127.7 BF50K.. - BF65K.. - BF80K.. 110 185~ 69.3 75 55 75 ø 6 149.5 DCRK... installed with BF...K contactors DCRJ... installed with BF...K contactors MAINS L1 L2 L3 MAINS L1 L2 L3 CT1 FU16 CT1 FU17 QS1 FU13 FU14 FU15 FU1 FU2 FU12 QS1 FU13 FU16 FU14 FU15 FU1 FU2 FU12 KM1 KM2 KM12 KM1 KM2 KM12 LOAD LOAD K1 K2 K12 K1 K2 K12 IMPORTANT a. For three phase connection, the voltage input must be connected between two phases; the line current transformer must be connected to the remaining phase. b. The polarity of the current input is irrelevant. c. When no auxiliary source is available, the line to be controlled (maximum 240VAC) can supply the regulator (DCRJ only). CAUTION! Always remove the power supply when oating on the terminals. BF9K - BF12K L1 L2 L3 1 3 5 BF20K - BF25K - BF40K - BF50K - BF65K - BF80K L1 1 L2 3 L3 5 A1 13 NO A1 A2 14 A2 2 4 6 T1 T2 T3 2 4 6 T1 T2 T3 PD23 GB 05 04 LOVATO ELECTRIC S.P.A. CONTROL SOLUTIONS FOR INDUSTRY Via Don E. Mazza, 12 24020 Gorle (Bergamo) Italy Tel. +39 035 4282111 Sales Department: TEL. +39 035 4282281 FAX +39 035 4282400 Web: www.lovatoelectric.com E-mail: info@lovatoelectric.com