Trusted Output Power Distribution Unit (Diode Protected)

Similar documents
Trusted Power Distribution Unit 15-Way Fused

Trusted 40 Channel Digital Input Versatile FTA

Trusted TMR Expander Interface Adapter Unit

Trusted Demonstration Unit

Trusted Toolset Application Validator Software Package

Trusted High Integrity Power Supply System ( Vac and 24 Vdc)

Trusted TMR Processor Interface Adapter (T8120, T8121, T8122, T8123, T8128, T8129)

Trusted Peer to Peer Communications Software Package

Trusted Power System. Product Overview. Features:

Trusted Power System. Product Overview. Features:

Trusted OPC Server Package

Trusted SC300E Bridge Module

Trusted Gateway Module

Trusted TMR Expander Processor

AADvance The Next Step in Automation

Trusted TMR 24 Vdc Analogue Input Module 40 Channel

Trusted Communications Interface

Trusted TMR 24 Vdc Digital Input Module 40 Channel

Trusted TMR 120 Vac Digital Output Module 16 Channel

Trusted TMR 24 Vdc Digital Output Module 40 Channel

InView Communication Modules

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

Trusted TMR 24 Vdc Valve Monitor Module - 40 Channel

InView Firmware Update

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

CompactLogix Power Supplies Specifications

Kinetix 6000 Axis Module and Shunt Module

Solar Combiner Enclosure

Trusted TMR Processor

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

Line Impedance Stabilization Network (LISN)

Plantguard Processor Interface Adaptor

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller

Kinetix 300 Memory Module Programmer

Trusted TMR Speed Monitor

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller

Teaching Color-Sensing Connected Components Building Block. Quick Start

Color-Sensing Connected Components Building Block. Quick Start

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Embedded I/O Expansion Board with 10 Outputs

XTM1250SA DIN rail three phase four wire LCD display energy meter

Product Compatibility and Download Center

PRO-75 SERIES. User manual

Differential Liquid/Gas Pressure Transmitter

Analog Monitor Installation Manual

Analog Input Installation Manual

Digital ac/dc (24V) Input Module

PowerMonitor 1000 Unit Catalog Number Upgrade

Model 7705 Control Module

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

User Manual Digital Input Module

PV Rapid Shutdown device

Ampt String Optimizer V600 Series. Installation Manual J. hdpv.org

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Zener Barriers Bulletin 937Z

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Product Compatibility and Download Center

Installation Instructions

GuardLogix: Safety Gate Application with SensaGuard Switch

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Agilent OBSAI Protocol Tester

User s Guide. 600A AC Clamp Meter. Model 38387

PowerMonitor 5000 Unit Catalog Number Upgrade

Installation Instructions

CPCI-PS24 24V-Power Supply

HV-CS kv Edge Mount Triaxial Jack

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch

Simple Package Measurement Connected Components Building Block. Quick Start

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

PanelView 600 Terminals

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

2260B-RMK-Series Rack Mount Kit

STARTUP GUIDE. SP en-us ENGLISH

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Tempco Instruction Manual

16-Channel Digital Input Termination Card 24Vdc

Allen-Bradley Motors

16-Channel Input Digital Input Termination Card

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Worldwide Energy and Manufacturing USA, Co., LIMITED Add: RM 1708 C1, NAN FUNG TOWER, 173 DES VOEUX RD CENTRAL, HK. Installation Manual

16-Channel Digital Input Termination Card 24Vdc

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Agilent 70612B K18 Switch Matrix

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Transcription:

PD_T8297 Trusted Trusted Output Power Distribution Unit (Diode Protected) Product Overview The Trusted Output Power Distribution Unit is designed to provide 24 Vdc - 120 Vdc for use with Trusted Sourcing Output Modules, e.g. T8451 and T8471, 24 Vdc and 120 Vdc Digital Output Modules respectively, and T848X Analogue Output Modules obtaining their 0 V reference via Trusted Versatile Field Termination Assemblies (VFTAs). The Unit is designed to be mounted on a DIN rail above the relevant Output Module I/O connectors. Features: Supports up to three Trusted Sourcing Output Modules. Dual stud power connection for either single or dual feed. On-board common cathode diodes for dual dc feeds (AO or low current DO only). Rockwell Automation Publication PD_T8297 Issue 7

Trusted PD_T8297 Page intentionally left blank Rockwell Automation Publication PD_T8297 Issue 7

Trusted Output Power Distribution Unit (Diode Protected) PREFACE PREFACE In no event will Rockwell Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples given in this manual are included solely for illustrative purposes. Because of the many variables and requirements related to any particular installation, Rockwell Automation does not assume responsibility or reliability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, with respect to use of information, circuits, equipment, or software described in this manual. All trademarks are acknowledged. DISCLAIMER It is not intended that the information in this publication covers every possible detail about the construction, operation, or maintenance of a control system installation. You should also refer to your own local (or supplied) system safety manual, installation and operator/maintenance manuals. REVISION AND UPDATING POLICY This document is based on information available at the time of its publication. The document contents are subject to change from time to time. The latest versions of the manuals are available at the Rockwell Automation Literature Library under "Product Information" information "Critical Process Control & Safety Systems". TRUSTED RELEASE This technical manual applies to Trusted Release: 3.6.1. LATEST PRODUCT INFORMATION For the latest information about this product review the Product Notifications and Technical Notes issued by technical support. Product Notifications and product support are available at the Rockwell Automation Support Centre at http://rockwellautomation.custhelp.com At the Search Knowledgebase tab select the option "By Product" then scroll down and select the Trusted product. Some of the Answer ID s in the Knowledge Base require a TechConnect Support Contract. For more information about TechConnect Support Contract Access Level and Features please click on the following link: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/50871 This will get you to the login page where you must enter your login details. IMPORTANT A login is required to access the link. If you do not have an account then you can create one using the "Sign Up" link at the top right of the web page. Rockwell Automation Publication PD_T8297 Issue 7 i

PREFACE Trusted Output Power Distribution Unit (Diode Protected) DOCUMENTATION FEEDBACK Your comments help us to write better user documentation. If you discover an error, or have a suggestion on how to make this publication better, send your comment to our technical support group at http://rockwellautomation.custhelp.com ii Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) PREFACE SCOPE This manual specifies the maintenance requirements and describes the procedures to assist troubleshooting and maintenance of a Trusted system. WHO SHOULD USE THIS MANUAL This manual is for plant maintenance personnel who are experienced in the operation and maintenance of electronic equipment and are trained to work with safety systems. SYMBOLS In this manual we will use these notices to tell you about safety considerations. SHOCK HAZARD: Identifies an electrical shock hazard. If a warning label is fitted, it can be on or inside the equipment. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which can cause injury or death, property damage or economic loss. ATTENTION: Identifies information about practices or circumstances that can cause injury or death. CAUTION: Identifies information about practices or circumstances that can cause property damage or economic loss. BURN HAZARD: Identifies where a surface can reach dangerous temperatures. If a warning label is fitted, it can be on or inside the equipment. This symbol identifies items which must be thought about and put in place when designing and assembling a Trusted controller for use in a Safety Instrumented Function (SIF). It appears extensively in the Trusted Safety Manual. IMPORTANT NOTE TIP Identifies information that is critical for successful application and understanding of the product. Provides key information about the product or service. Tips give helpful information about using or setting up the equipment. Rockwell Automation Publication PD_T8297 Issue 7 iii

PREFACE Trusted Output Power Distribution Unit (Diode Protected) WARNINGS AND CAUTIONS WARNING: EXPLOSION RISK Do not connect or disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations or equivalent AVERTISSEMENT - RISQUE D EXPLOSION Ne pas connecter ou déconnecter l équipement alors qu il est sous tension, sauf si l environnement est exempt de concentrations inflammables ou équivalente MAINTENANCE Maintenance must be carried out only by qualified personnel. Failure to follow these instructions may result in personal injury. CAUTION: RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference. Caution should be exercised with regard to the use of portable communications equipment around such equipment. Signs should be posted in the vicinity of the equipment cautioning against the use of portable communications equipment. CAUTION: The module PCBs contains static sensitive components. Static handling precautions must be observed. DO NOT touch exposed connector pins or attempt to dismantle a module. iv Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) PREFACE ISSUE RECORD Issue Date Comments 5 Sep 05 Format 6 Sep 15 Rebranded and reformatted 7 Apr 16 Standardisation of Relative Humidity Range and Operating Temperature statements in the Specification Section Rockwell Automation Publication PD_T8297 Issue 7 v

PREFACE Trusted Output Power Distribution Unit (Diode Protected) Page intentionally left blank vi Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) Table of Contents Table of Contents 1. Description... 3 2. Installation... 5 3. Associated Cable Selection... 7 4. Pin-out Connections... 9 5. Specification... 11 Rockwell Automation Publication PD_T8297 Issue 7 1

Table of Contents Trusted Output Power Distribution Unit (Diode Protected) Page intentionally left blank 2 Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) 1. Description 1. Description Figure 1 T8297 Photo The wiring diagram of the Trusted Output Power Distribution Unit is shown in Figure 2. Figure 2 Trusted Output Power Distribution Unit Wiring Diagram The Trusted Output Power Distribution Unit is designed to distribute the +ve field loop power for the 24 Vdc - 120 Vdc range of Trusted Sourcing Output Modules. The output 0 V reference and 0 V power return is via the Trusted Versatile Field Termination Assembly (VFTA). Up to three Output Modules may be supported providing the total load does not exceed the maximum rated capacity of the Unit. Rockwell Automation Publication PD_T8297 Issue 7 3

1. Description Trusted Output Power Distribution Unit (Diode Protected) Each supply stud is capable is capable of supplying the maximum rated capacity and can be used in single or dual configuration as required. Dual configuration may be used where the supply is fed via blocking diodes. Where the total load current for three Trusted Analogue or Digital Output Modules is less than 6 A, the supply can be fed via the on-board blocking diodes through terminal block TB1. If this method of supply is used, insulating sleeves must be fitted to the redundant power studs. 4 Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) 2. Installation 2. Installation The Trusted Output Power Distribution Unit may be mounted on TS32 or TS35 DIN rails. Rockwell Automation Publication PD_T8297 Issue 7 5

2. Installation Trusted Output Power Distribution Unit (Diode Protected) Page intentionally left blank 6 Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) 3. Associated Cable Selection 3. Associated Cable Selection The output cables detailed in PD-TC100 and PD-TC200 may be used to connect the Unit to the associated output modules Rockwell Automation Publication PD_T8297 Issue 7 7

3. Associated Cable Selection Trusted Output Power Distribution Unit (Diode Protected) Page intentionally left blank 8 Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) 4. Pin-out Connections 4. Pin-out Connections Refer to Figure 2. Rockwell Automation Publication PD_T8297 Issue 7 9

4. Pin-out Connections Trusted Output Power Distribution Unit (Diode Protected) Page intentionally left blank 10 Issue 7 Rockwell Automation Publication PD_T8297

Trusted Output Power Distribution Unit (Diode Protected) 5. Specification 5. Specification Voltage Range Supply Current (via studs) Supply Current (via TB1) Supply Connection +ve (stud) Supply Connection +ve (TB1) Power Output (3-off) 22 Vdc - 120 Vdc 65 A max 6 A max 2-off M6 x 25 mm studs BLZ 2-part terminal 6-way AMP MATE-N-LOK connector Conductor Clamping Range 0.5 mm 2 to 2.5 mm 2 Operating Temperature 0 C to +60 C (+32 F to +140 F) Non-operating Temperature -25 C to +70 C (-13 F to +158 F) Relative Humidity range (operating, storage & transport) 10 % 95 %, non-condensing Environmental Specifications Refer to document 552517 Dimensions Height Width Depth (including mounting rail) 70 mm (2.75 in) 90 mm (3.54 in) 50 mm (1.9 7 in) Weight 100 g (0.22 lb) Rockwell Automation Publication PD_T8297 Issue 7 11