IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Similar documents
Absolute Encoder ZE-115-M

CE-65-M INTERBUS-S. Operating Instructions. Retain for future use!

Operating instructions. Standstill monitor A / / 2011

Absolute Encoder ZE Series

Absolute Encoder HE-65-M

GS202 Encoder Switch

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

Faults on the system Proximity switch connection technology:

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

HE-65 CAN-BUS. (DeviceNet-Slave) Technical Information TR - ECE - TI - GB /30/2016

AK-30 Profibus-DP Operating Manual for Axis Cassette with PNT Measuring Systems Please keep for further use!

Laser Measuring Device LE-200

MDM-8. Technical Documentation Parallel Output Module. Please keep for further use!

GV204 Impulse Splitter for Incremental Encoders

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINC-2 Technical Documentation ICI (Incremental Counter Interface) Submodule Please keep for further use!

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ISG Isolated DIN Rail Mount Signal Conditioner Issue: Revision A Technical User Manual

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Serial PROFIBUS Interface

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

DC562, digital input/output module,

SmartWire-DT Modules IP67

Assembly instruction / User manual

DI561 Digital Input Module

Type Quickstart (from device Version 2)

RTU500 series Data Sheet Power Supply CP-E 24/2.5

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

SMVector Additional I/O Module Installation and Operation Manual

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Type ME43. Quickstart

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

AI561 Analog Input Module

DX561 Digital Input/Output Module

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

DC561, digital input/output module,

SINCOS. Linear Stepper Motor Power Stage. Manual 2066-A006 GB

MINI MCR-SL-UI-REL(-SP)

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

MINI-PS AC/10-15DC/8

MINI MCR-SL-PT100-UI-200

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Operating instructions Evaluation system for flow sensors VS / / 2013

USB I/O-CARD WITH 32 INPUTS

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

MINI MCR-SL-UI-2I(-SP)(-NC)

Electronic Temperature Controller. Instruction Manual Version

User manual BLCDN-8M12LT-8XSG-PD-8XSGPD

DI572 Digital Input Module

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

AO523 Analog Input Module

User Manual HMI Linkbox HL01 DP/MPI

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Operating Instructions

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-CVS NC

Laser Measuring Device LE-200

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating instructions IO-Link master CabinetLine AL19xx

Operating Instructions Differential Pressure Transducer PS27

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SIMADYN D Digital Control System. Expansion Module IT41. User Manual. Edition DK No

MDM 011-Z1 Regen Resistor

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Power supply CP-E 24/0.75 Primary switch mode power supply

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

User manual Technical parameters

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

CPCI-PS24 24V-Power Supply

User Manual BLCDP-2M12MT-2RFID-S

Transcription:

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC Author: WEA

Contents TR-Electronic GmbH D-78647 Trossingen Eglishalde 6 Tel.: (0049) 07425/228-0 Fax: (0049) 07425/228-33 E-mail: info@tr-electronic.de http://www.tr-electronic.de Copyright protection This Manual, including the illustrations contained therein, is subject to copyright protection. Use of this Manual by third parties in contravention of copyright regulations is forbidden. Reproduction, translation as well as electronic and photographic archiving and modification require the written content of the manufacturer. Offenders will be liable for damages. Subject to amendments Any technical changes that serve the purpose of technical progress, reserved. Document information Release date/rev. date: 09/08/2006 Document rev. no.: TR - EAK - BA - GB - 0093-02 File name: TR-EAK-BA-GB-0093-02.DOC Author: WEA Font styles Italic or bold font styles are used for the title of a document or are used for highlighting. Courier font displays text, which is visible on the display or screen and software menu selections. < > indicates keys on your computer keyboard (such as <RETURN>). 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 2 of 18

Contents Contents Contents...3 Revision index...4 1 Safety...5 1.1 General Potential for Danger...5 1.2 Safety Information...5 1.2.1 Installation information...6 1.2.1.1 Screening...7 1.2.1.2 Measures for Interference Suppression...7 1.3 Appropriate Use...8 1.4 Danger Due to Particular Types of Use...9 1.5 Danger Due to Accessories...9 1.6 Authorized Operators...9 1.7 Safety Measures at the Place of Assembly...10 2 Transportation / Storage...10 3 Assembly instructions...11 4 Commissioning...12 4.1 General information about the device...12 4.2 Block diagram...13 4.3 Cassette design...14 4.4 Input circuit, differential +5V...15 4.5 Adjusting of the output levels...15 5 Appendix...16 5.1 Pin assignments...16 5.1.1 Incremental input X0...16 5.1.2 Supply voltage X7...16 5.1.3 Incremental outputs X1 - X6...17 5.2 Technical data...18 Drawings Dimension drawing... 04-975-007 Mating connectors... 00-000-1066 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 3 of 18

Revision index Revision index Revision Date Index First release 09/08/06 00 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 4 of 18

Safety 1 Safety 1.1 General Potential for Danger If you use the cassette in conjunction with a programmable TR Encoder (CE / ZE series), it is possible to output different signal bits. Additional functions such as self-monitoring, detection of standstill and direction of rotation, speed control and soft-limit-switches are provided by means of these signal bits. Therefore it is crucial to integrate the signal bits into your own safety concept by means of the PLC's evaluation software. The cassette provides no diagnostics for errors. All the persons who are involved in the assembly, commissioning and operation of the device must be appropriately qualified d must follow exactly the instructions in this manual This is for your own safety and the safety of your equipment! 1.2 Safety Information This operating manual contains information that you must comply with to ensure your personal safety and to avoid damage to property. The information is emphasized by warning triangles, which have different appearances to match the level of danger: Warning Means that if the appropriate safety measures are ignored, death, severe injury or considerable damage to property can occur. i Caution Means that if the appropriate safety measures are ignored, slight injury or damage to property can occur. Note Emphasizes important information about the product, its properties or helpful information for using it. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 5 of 18

Safety 1.2.1 Installation information Due to the fact that the cassette is normally used as a component part of a larger system, this information is intended to provide a guideline for safe installation of the cassette in its environment. Warning Observe the safety and accident prevention regulations that apply to the specific application. In the case of equipment with a fixed connection (stationary installations/systems) without all-pole mains switches and/or fuses, you must install a mains switch or a fuse in the system and connect the equipment to a protective earth. Before commissioning devices that are run with mains voltage, check whether the set rated voltage range matches the local mains voltage. With a 24-V supply, ensure safe electrical isolation of the extra-low voltage. Use only mains units that comply with IEC 364-4-41 or HD 384.04.41 (VDE 0100 Part 410) standards. Fluctuations in or deviations from the rated mains voltage may not exceed the tolerances stated in the technical data. If they do, functional failures of the electrical components and hazardous conditions cannot be ruled out. You must take precautions to ensure that, following voltage dips and failures, it is possible to restart an interrupted program in an orderly manner. In this context, no dangerous operating status conditions may occur even for a brief period of time. If necessary, you must force an EMERGENCY STOP. EMERGENCY STOP devices that comply with EN 60204/IEC 204 (VDE 0113) must remain effective in all the operating modes of the automation equipment. Unlocking the EMERGENCY STOP devices must not result in an uncontrolled or undefined restart. Install the connecting and signal lines such that inductive and capacitive interference does not adversely affect the automation functions. Install automation technology equipment and its operator input elements such that they are sufficiently protected against being operated by mistake. Take appropriate hardware and software measures in the I/O link to prevent possible cable or wire breakages on the signal side leading to undefined status conditions in the automation equipment. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 6 of 18

Safety 1.2.1.1 Screening The use of electronic sensor active systems in modern machines makes it crucial to enforce a consistent and correctly executed interference suppression and wiring concept. These conditions are the only guarantee that systems containing electronic measuring systems and the cassette will function properly. Recommended Screened Cable Wiring Switching Cabinet Measuring Systems Machine Control Unit 0V bar with screen terminal for measuring system cable Power Unit Measuring system and control cable Power Cable Ground cable 10 mm² (R ground cable << R screen ) 1.2.1.2 Measures for Interference Suppression Feed the connecting line to the cassette at a large distance, or separately, from power lines carrying interference. Use only completely screened lines for data transfer and ensure they are well earthed. In the case of differential data transfer, (RS422, RS485, etc.), you must additionally use twisted-pair lines. Use cables with a minimum cross-section of 0.22 mm² for data transfer. Use a ground cable with a minimum cross-section of 10 mm² to avoid equipotential bonding via the screen. In this context, you should ensure that the ground cable's resistance is much lower than the screen's resistance. Wire the screen continuously keeping a large area in contact with special screen connecting terminals. Avoid crossing cables. If this is not possible, the cables should only cross at rightangles. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 7 of 18

Safety 1.3 Appropriate Use The pulse distributor IV-30 is used in complex plants together with incremental encoders for extending the signal path. The device allows distribution of the signals K1, /K1 and K2, /K2 as well as K0, /K0 of a single encoder to six outputs with each different output potentials. Warning Deenergize the system before carrying out wiring or opening and closing electrical connections! Short-circuits, voltage peaks etc. can lead to malfunctions and uncontrolled conditions in the system or to serious personal injury or damage to property. Before switching on the system, check all the electrical connections! Connections that are made incorrectly can lead to system malfunctions; wrong connections may result in serious personal injury or damage to property. For safety reasons, mechanical or electrical changes to the axis cassette or to the measuring systems are prohibited! i Note Always keep to the commissioning and operating instructions specified in this manual. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 8 of 18

Safety 1.4 Danger Due to Particular Types of Use Caution A current that is too high will destroy the cassette! A maximum current of 300 ma may be taken from the cassette's power supply (encoder connector). If the current is above 300 ma, the encoder must be fed from a separate supply. Encoders that have built-in heating must also be supplied separately. 1.5 Danger Due to Accessories Caution Mating connectors that are not plugged in correctly can lead to a cassette malfunction! Tightly screw the mating connector to its intended connector. 1.6 Authorized Operators This device may only be commissioned by qualified personnel. In the context of the safetyspecific information in this document, qualified personnel are considered to be persons who are authorized to commission, ground and mark circuits, equipment and systems in accordance with recognized safety standards. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 9 of 18

Transportation / Storage 1.7 Safety Measures at the Place of Assembly Warning Do not carry out welding if the cassette has already been wired-up or is switched-on! Potential fluctuations can destroy the cassette or adversely affect its function. Do not touch connector contacts with your hands! Static charges could destroy the electronic components in the cassette. Inputs that are not being used may not be connected (refer to the pin assignments) i Keep to the supply voltage range: 24 V DC ±20% (including residual ripple) Note Ensure that the area around the place of assembly is protected from aggressive media (acid, etc.). 2 Transportation / Storage Transportation Information Do not drop cassette or subject them to excessive jolting! The device contains sensitive electronic components. Use only the original packaging material! Incorrect packaging material can cause damage to the device in transit. Storage Storage temperature: -30 to +80 C Store in a cool place. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 10 of 18

Assembly instructions 3 Assembly instructions The cassette are designed to be mounted on rails in the switch cabinet. No extra assembly accessories are required for mounting the cassette on the rail. The cassette housing is placed on the mounting rail from below and pushed upwards with the tension springs (Fig. 1). Simply push the cassette housing against the mounting rail until it snaps into place (Fig. 2). Fig. 1 Fig. 2 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 11 of 18

Commissioning 4 Commissioning 4.1 General information about the device The impulse divider IV 30 is used in complex plants together with incremental encoders for extending the signal path. All signal inputs and outputs are designed potential separated. That means there is no connection of the signals to the supply voltage (0V) between the channels. The unit allows distribution of the signals K1, /K1 and K2, /K2 as well as K0, /K0 of a single encoder to six outputs with each different output potentials. For each channel the RS422 output level must be selected separately by a corresponding jumper coding in the mating connector. If other output levels are used, these must be adjusted by feeding of a separate voltage to UP-I and 0V. The input needs differential 5V signals. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 12 of 18

Commissioning 4.2 Block diagram galvanic separation K0, K1, K2 and inversions Power supply Encoder X0 pin 8, 10 = +5V or pin 9, 10 = US Encoder connection (ISI) X0 ISI-output channel 1 X1 Auxiliary voltage and voltage level codification Channel 1 K0, K1, K2 and inversions Power supply (US) encoder (X7 pin 1, 2) Power supply (US) Encoder X7 ISI-output channel 2 X2 Auxiliary voltage and voltage level codification Channel 2 K0, K1, K2 and inversions Power supply for unit IV-30 (X7 pin 9, 10) Power pack for IV-30 ISI-output channel 3 X3 Auxiliary voltage and voltage level codification Channel 3 K0, K1, K2 and inversions ISI-output channel 4 X4 Auxiliary voltage and voltage level codification Channel 4 K0, K1, K2 and inversions ISI-output channel 5 X5 Auxiliary voltage and voltage level codification Channel 5 K0, K1, K2 and inversions ISI-output channel 6 X6 Auxiliary voltage and voltage level codification Channel 6 K0, K1, K2 and inversions 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 13 of 18

Commissioning 4.3 Cassette design Front view IV30 Input connector X0 Supply of the incremental signals K0, K1, K2 and their negated signals as well as an optional supply of the signal source with +5VDC / 300mA or with +24VDC ± 20%. Supply voltage X7 About this connector the supply voltage for the device and signal source (encoder) must be connected. Output connector X1 - X6 for the channels 1 to 6 According to the jumper codings in the mating connectors the incremental signals at the channels 1 to 6 with RS422-level or optionally with 24V ± 20% can be picked off. The 0V-Signal at X1 to X6 is reference potential of the respective output. Under each other it exist a galvanic separation. 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 14 of 18

Commissioning 4.4 Input circuit, differential +5V This complies with the basic configuration of the device for differential signal input levels. The device requires all incremental traces (K0, K1, K2 and their negated signals). Principle wiring diagram for input circuit Kx RS485 Receiver Succeeding electronics / Kx 4.5 Adjusting of the output levels The output level can be selected separately for each channel by a corresponding jumper codification in the mating connector: 1. RS422 output level 2. (11-29)V output level Connector X1 - X6 Connector X1 - X6 1 2 3 4 5 6 7 8 9 10 K0+ K0- K1+ K1- K2+ K2-0V 5V-O US-O* UP-I 1 2 3 4 5 6 7 8 9 10 K0+ K0- K1+ K1- K2+ K2-0V 5V-O US-O* UP-I 0V 11-29 V Jumper 1: 8/10 with internal 5V voltage supply with external voltage supply (The supply voltage should be filtered against EMC-disturbances) * only available in the 24V variant, without galvanic separation 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 15 of 18

Appendix 5 Appendix 5.1 Pin assignments 5.1.1 Incremental input X0 Pin number Pin name Function Level 1 K0+ Input reference impulse 5V differential 2 K0- Input reference impulse, negated 5V differential 3 K1+ Input signal1 5V differential 4 K1- Input signal1, negated 5V differential 5 K2+ Input signal2 5V differential 6 K2- Input signal2, negated 5V differential 7 --- --- --- 8 5V-O Encoder supply 5V 5V / 0,3 A 9 USE-O Encoder supply US 24V ±20% 10 0VE-O Encoder supply 0V 0V 5.1.2 Supply voltage X7 Pin number Pin name Function Level 1 USE-I Input encoder supply 24V ±20% 2 0VE-I Input encoder supply 0V 3 --- --- --- 4 --- --- --- 5 --- --- --- 6 --- --- --- 7 --- --- --- 8 --- --- --- 9 US-I Output supply US 24VDC ±20% 10 0V-I Output supply 0V 0V 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 16 of 18

Appendix 5.1.3 Incremental outputs X1 - X6 Pin number Pin name Function Level 1 K0+ Output reference impulse RS422 or ext. 11V..24V 2 K0- Output reference impulse, negated RS422 or ext. 11V..24V 3 K1+ Output Signal1 RS422 or ext. 11V..24V 4 K1- Output Signal1, negated RS422 or ext. 11V..24V 5 K2+ Output Signal2 RS422 or ext. 11V..24V 6 K2- Output Signal2, negated RS422 or ext. 11V..24V 7 0V Output reference potential 0V 8 5V-O 9 US-O* 10 UP-I Output coding Signal supply +5V Output coding Signal supply +US Input coding Signal supply +5V / 0,15 A +24V ±20% +5V...+24V * only available in the 24V variant, without galvanic separation 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 17 of 18

Appendix 5.2 Technical data Device supply... Power pack for 24VDC ±20% Aux. voltage output (optional)... Connector X0 galvanically decoupled +5V encoder, max. 300mA Connector X1-6 galvanically decoupled +5V per signal channel, max. 150mA Reverse battery protection... Yes Transient voltage protection... ESD Excess current release... VDE 0113 Filter groups... IEC 1000-4-x Current consumption (unloaded)... approx. 120 ma min./max. input current per track... 1.5mA / 20mA * Output level... RS422 according to DIN 66 384 or ISO/IEC 8482 max. input impulse frequency... 250 khz Operating temperature range... 0-60 C Weight... approx. 500g * The given norm defines the signal levels as follows: Respectively, reference is the 0V signal of the receiver. The signals may "float" from -7 V to +12V (common mode range) On the side of the transmitter the difference level must be > ±1,5 V On the side of the receiver the difference level must be > ±0,3 V 09/08/2006 TR - EAK - BA - GB - 0093-02 Page 18 of 18