Made in Germany Product characteristics Magnetic-inductive flow meter Connector Process connection: G2 flat seal connection to pipe by means of an adapter Function programmable Totaliser function Empty pipe detection 2 outputs OUT1: flow monitoring (binary), quantity meter (pulse), preset counter (binary) OUT2: flow or temperature monitoring (analogue or binary) Input for counter reset 4-digit alphanumeric display
5...300 l/min -20...80 C Application Application Medium temperature Electrical data Electrical design Operating voltage [V] Current consumption [ma] Insulation resistance [MΩ] Protection class Reverse polarity protection Outputs Output function Current rating [ma] Voltage drop [V] Short-circuit protection Overload protection Analogue output Max. load [Ω] Min. load [Ω] Pulse output Frequency range [Hz] Measuring / setting range Empty pipe detection Resolution Reset point, rp Analogue start point, ASP Analogue end point, AEP Flow end point, FEP Low flow cut-off, LFC Measuring dynamics Frequency end point, FrEP Volumetric flow quantity monitoring Conductive liquids (conductivity:>= 20 µs/cm / viscosity: < 70 mm²/s at 40 C) -10...70 DC PNP/NPN 18...32 DC ¹) < 150 > 100 (500 V DC) III OUT1: normally open / normally closed programmable or pulse or frequency or empty pipe detection or IO-Link OUT2: normally open / normally closed programmable or analogue (4...20 ma; 0...10 V, scalable) or empty pipe detection 5...300 l/min -360...360 l/min 0.5 l/min 6.5...300 l/min 5...298.5 l/min 0...240 l/min 60...300 l/min 0.5 l/min 2 x 250 < 2 pulsed 4...20 ma; 0...10 V 500 (4...20 ma) 2000 (0...10 V) flow rate meter 10...10000 normally closed / open 20...300 l/min; 1.5...18 m³/h 5...15 l/min; 0.3...0.9 m³/h 1:60 0.01...10 khz 10 Hz 0.0 9999 x 10³ 0.3...18 m³/h -21.6...21.6 m³/h 0.02 m³/h 0.4...18 m³/h 0.3...17.9 m³/h 0...14.4 m³/h 3.6...18 m³/h 0.02 m³/h
Pulse value Pulse length Resolution Reset point, rp Analogue start point, ASP Analogue end point, AEP Accuracy / deviations Accuracy Repeatability Pressure loss (dp) / flow rate (Q) 0.0 9999 x 10³ 0.1 9999 x 10³ 0.1 l...300 x 10³ m³ 0.1 l 0.016...2-20...80-40...100 0.2-19.2...80.0-19.6...79.6-20...60 0...80 0.2 ± (0.8% MW + 0.5% MEW) ²) ± 0.2% MEW Accuracy Temperature drift Reaction times Power-on delay time Start-up delay Response time Damping, dap Response time Software / programming Programming options [K] ± 1 (25 C; Q > 15 l/min) ± 0.0333 C / K 5 0...50 < 0.25 (dap = 0) 0...5 T09 = 3 (Q > 15 l/min) Hysteresis / window; NO / NC; output logic; current / voltage / frequency / pulse output; start-up delay; display can be deactivated; display unit; empty pipe detection
Interfaces IO-Link Device Transfer type IO-Link revision SDCI standard IO-Link Device ID Profiles SIO mode Required master port type Process data analogue Process data binary Min. process cycle time Environment Pressure rating Ambient temperature Storage temperature Protection Tests / approvals EMC EC pressure equipment directive 97/23/EC Shock resistance Vibration resistance Mechanical data Process connection Materials (wetted parts) Housing materials Weight Displays / operating elements Display Electrical connection Connection Wiring [ms] [bar] [kg] COM2 (38.4 kbaud) 1.1 IEC 61131-9 CDV 359 d / 00 01 67 h Smart Sensor: Process Data Variable; Device Identification A 3 2 5 16-10...60-25...80 IP 65 / IP 67 DIN EN 61000-4-2 ESD: 4 kv CD / 8 kv AD DIN EN 61000-4-3 HF radiated: 10 V/m DIN EN 61000-4-4 Burst: 2 kv DIN EN 61000-4-5 Surge: 1 kv DIN EN 61000-4-6 HF conducted: 10 V DIN EN 60068-2-27: DIN EN 60068-2-6: G2 flat seal 20 g (11 ms) 5 g (10...2000 Hz) stainless steel 316L / 1.4404; stainless steel 316Ti / 1.4571; PEEK (polyether ether ketone); Hastelloy C-4 (2.4610); Centellen; FKM stainless steel 316L / 1.4404; stainless steel 316Ti / 1.4571; PC (polycarbonate); FKM; PBT-GF 20; elastolan 3.064 Display unit 6 x LED green (l/min, m³/h, l, m³, 10³, C) Switching status 2 x LED yellow Measured values 4-digit alphanumeric display Programming 4-digit alphanumeric display M12 connector; gold-plated contacts
OUT1/IO-Link: 5 selection options - switching output empty pipe detection - switching output flow rate monitoring - frequency output flow rate monitoring - pulse output quantity meter - signal output preset counter OUT2/InD: 6 selection options - switching output empty pipe detection - switching output flow rate monitoring - switching output temperature monitoring - analogue output flow rate - analogue output temperature - input signal counter reset Accessories Accessories (included) Remarks Remarks Pack quantity [piece] 2 x packing washer (Centellen); Label ¹) to DIN EN 50178, SELV, PELV ²) Q > 15l/min, Mediums- und Umgebungstemperatur +22 C ± 4K MW = measured value MEW = final value of the measuring range 1 ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice. GB SM9000 12.04.2013