MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

Similar documents
Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Intrinsically Safe Temperature Concentrator System

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

C160 Wall-/Pipe Mounted Universal Process Indicator

/8 DIN Universal Process Indicator

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Wall-/Pipe Mounted Universal Process Indicator

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

SX90 Process Controller

Intrinsically Safe Barriers

MLC 9000 Bus Compatible PID

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

/8 DIN Motorized Valve Controller

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

UNIVERSAL TEMPERATURE TRANSMITTER

Intrinsic Safety Control Drawing

Measurement Systems Datascan Installation and User Guide

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Vibration Transducer Interface

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no:

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no:

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Temperature/Process Controllers Manual

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

UNIVERSAL CURRENT CONVERTER

Safety instructions VEGATOR 121, 122

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

100mm Process Indicator Recorder

Trident and Trident X2 Digital Process and Temperature Panel Meter

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM101(1445) For 4511 devices from ser. no:

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

HART UNIVERSAL TEMPERATURE TRANSMITTER

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

Hazardous Area Protection

SITOP 3-phase 24 V DC, 20 to 40 A

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

5 Fieldbus Technology

BA505C 2-wire 4/20mA manual setpoint station Issue 6

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

HART UNIVERSAL TEMPERATURE TRANSMITTER

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

PD765 TRIDENT. Trident Series Process & Temperature Meters.

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

MODCELL 2050R Single Loop Controllers

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

RS-485 I/O Modules: ADAM-4000

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

INSTALLATION INSTRUCTIONS

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

LAUREL ELECTRONICS, INC.

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

VersaMax Micro and Nano Technical Product Presentation

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

FICHA TÉCNICA DE PRODUTO

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Strip Chart Recorders Specification Sheet

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

APPLICATION GUIDE. Interface Modules IM Series.

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Easy installation automatic earthing with simple DIN-rail mounting. Ultra-slim space-saving design

ACT20X-(2)HTI-(2)SAO Temperature/mA converter. Safety Manual

Millenium 3 logic controllers

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Level-Lance Model 5400A

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

DMC-1400 Documenting Multi-function Calibrator

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

M-series Traditional I/O

technical datasheet SD Series

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

NCS MIM. with MODBUS Interface. NET Concentrator System. September A. with MODBUS Interface

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Transcription:

830 SERIES Cuts installation and cable costs for all IS hazardous-area circuits Reduce the cost of installing hazardous-area cabling Save installation time, space and weight Highlight problems quickly with status reporting systems Protect the process with sensor failure detection and safety drives Connect directly to host systems through serial-data outputs Analogue inputs to controllers with Modbus communications Redundant data highways 830 Series s with Modbus outputs provide a cost-effective alternative to singleloop isolation. The cost of installed wiring is reduced by up to 50% by communicating the input of multiple hazardous-area sensors over dual-redundant data highways. Further savings are achieved by reducing the number of inputs to the host, cabinet space and weight. A, mounted in the hazardous area, caters for thermocouple, RTD and mv analogue inputs. A compatible safe-area receiver provides serial Modbus outputs for feeding to host PLC, PC or DCS controllers. Dual-redundant data highways between the and the receiver allow continuous normal operation with only one highway connected. The highway cable, a simple twisted pair or a pair of wires within an IS multi-core cable, carries both power and data, over distances up to 2km. If the is located in the hazardous area, each data highway must be protected by an 3052 digital isolator. Multiplexer systems can communicate the status of up to 32 inputs, reducing the number of hazardous area wiring pairs from 32 to two. Reduce costs by eliminating long runs of expensive thermocouple compensation cable from the hazardous to the safe area. AIso, if 3- or 4-wire RTDs are used, costs are reduced by terminating each RTD at the or its enclosure. Dual redundant highways increase system reliability. Failure detectors and safety drives protect against the consequences of sensor failure, while built-in systems report failures to the host controller. Accessories include steel and stainless-steel enclosures, earth-leakage detectors and a PC-based configuration software package. For more information see AN9010, A user s guide to s and TP1098, Cut the cost of intrinsic safety by multiplexing!

MULTIPLEXER TRANSMITTER 838B-MBF RECEIVERS s are normally sited in the hazardous area. They are connected to sensors in the field and communicate these inputs to the safe area via single-pair data highways. The data highways support communication between the safe and hazardous areas,and also provide power to the s no additional field power is required. The would typically be mounted close to the field instruments in an enclosure such as the ENC8 or ENC83 (see '800 Series Enclosures'). ANALOGUE INPUT TRANSMITTER Monitors inputs from up to 16 THC or millivolt sources (max ±60mV) or up to 15 2-, 3- or 4-wire RTDs within a hazardous area. Intrinsically safe; Zone 0 location Communication and power pass over twin data highways Powered by the data highway Thermocouples and RTDs may be mixed on one MULTI-DROPPING TWO S Two s can share the same single-pair highway to a single safe-area isolator/receiver combination, providing up to 32 multiplexed inputs. 838B-MBF receivers translate the information transmitted from the via the data highway. The 838B-MBF provides a Modbus serial-data output representation of the inputs together with status information. 838B-MBF MODBUS ANALOGUE RECEIVER Translates data received from the in the hazardous area and makes it available as twin RS485 Modbus serial data outputs. The 838B-MBF is configured by personal computer for thermocouple and RTD type, safety drive, high and low alarm and any other operational parameters. 3052 DATA HIGHWAY ISOLATOR An 3052 isolator is required for each data highway, when the is located in a hazardous area. It is not required for safearea applications. MULTI-DROPPING MODBUS RECEIVERS Up to 31 Modbus receivers can be multi-dropped on a single RS485 link to the host system. Modbus receivers can be controlled by any suitable Modbus master. The receivers may be used with other Modbus slaves on the same RS485 link. DATA HIGHWAY CABLING Cabling with low capacitance and resistance is recommended to achieve greater distances between s and receivers. See cable parameters in 'Basic Specifications' for specific requirements, and contact for latest cable recommendations. The system is designed to use both data highways, although it can be used with only one data highway in place. However, use of a single highway will increase response time. Data highway lengths of up to 2km in hazardous areas and 3km in safe areas have been achieved. ENCLOSURES A range of steel and stainless steel enclosures is available for mounting units in the field (see '800 Series Enclosures'). ENC8 and ENC8SS (stainless steel) enclosures provide protection for a single. The enclosures are dust-tight and waterproof to IP67. When using 4-wire RTDs, ENC83 and ENC83SS (stainless steel) enclosures provide additional terminals to accommodate the third and fourth RTD wires, which are not connected to the itself.

830 SERIES MULTIPLEXER SYSTEM DIAGRAM Hazardous area Safe area mv Up to 16 THC, RTD and mv inputs Data highway(s) to safe area Up to 32 signal inputs from (s) Data highway(s) from hazardous area 3052 isolator(s) 838B-MBF receiver 20 35V dc PCS83 configuration software Modbus master A Modbus master B Multi-dropping s Up to 30 multi-dropped Modbus slaves Additional

TRANSMITTERS BASIC SPECIFICATIONS (see also 'Common specification') (mv input) Number of input channels 16 THC or mv sources, potentiometer inputs up to 1kΩ) 15 (RTD or mixed) (IS segregated and fully floating when used with 3052) Location of input sources Zone 0, IIC, T4 Location of unit Zone 0, IIC, T4 Number of data highways Dual redundant (either or both) Power requirement Loop-powered through data highway from receiver No hazardous-area power supply required Multi- facility 1 or 2 Ambient temperature limits -20 to 60 C working -40 to 80 C storage Weight 1.3kg Typical response time 1s for each (input to receiver output) Electrical safety (each input circuit) Umax:out = 15V Imax:out = 16.3mA Wmax:out = 60mW Input sensor cable parameters BASEEFA values (C,L or L/R) (IIC) (IIB) (IIA) Electrical safety (data highwaycircuit[s]) maximum input parameters Cable parameters (data highway circuits, each highway) BASEEFA values (C,L or L/R) (IIC) (IIB) (IIA) 0.8µF,120mH or 505µH/Ω 2.4µF, 360mH or 1515µH/Ω 6.4µF, 960mH or 4040µH/Ω Umax:in = 30V Imax:in = 300mA Wmax:in = 1.2W Ceq = 0, Leq = 0 0.75µF, 5.2mH or 109µH/Ω 2.25µF,15.6mH or 327µH/Ω 6.00µF, 41.6mH or 827µH/Ω ADDITIONAL SPECIFICATIONS Each input terminal block is user-selectable by switch for mixed mv, THC, 2- or 4-wire RTD input or 3-wire RTD input. Measuring ranges ±60mV or ±25mV or ±10mV, auto ranging Common mode voltage Maximum 5V common mode between input channels of one mv signals Accuracy at 20 C (including non-linearity and hysteresis) <0.1% of measuring range Temperature effects on accuracy {(greater of 0.01% of range or 2µV) 0.01% of reading} / C Thermocouple signals Accuracy at 20 C (including non-linearity and hysteresis) <0.1% of measuring range ±0.7 C Upscale/downscale drive does not introduce any accuracy errors Temperature effects on accuracy {(greater of 0.01% of range or 2µV) 0.01% of reading 0.03 C}/ C RTD signals RTD range -200 to 850 C (Pt100 type, DIN 43760, IEC751: 1983) RTD excitation current 100µA Accuracy at 20 C (including non-linearity and hysteresis) <0.1% of measuring range Temperature effects on accuracy {(greater of 0.01% of range or 0.025 C) 0.005% of reading}/ C

838B-MBF RECEIVERS BASIC SPECIFICATIONS (see also Common specification ) 838B-MBF (Modbus output) Number of data highways 2, dual redundant (either or both may be used) Location of unit Safe area Input noise rejection Up to 0.5mA peak-to-peak at 100 to 1000Hz, or up to 1mA peak-to-peak at 50Hz Type of output(s) Dual RS485 Modbus protocol System protocol Modbus ASCII or RTU Serial communication parameters Baud rate: 300 to 19200 Stop bits: 1 or 2 Data bits: 7 or 8 Parity bit: odd, even or none Multi-receiver facility Up to 31 838B-MBF units can be connected to communicate with one Modbus master controller Power requirement 500mA at 20 35V dc Ambient temperature limits -20 to 50 C working -40 to 80 C storage Weight 840g ADDITIONAL SPECIFICATIONS 838B-MBF Thermocouple range supported Types E, J, K, N, R and T THCs to IEC 584. Other options are available, please contact for details. System configuration Serial communications parameters and system parameters entered using PCS83 software program, by downloading from process controller. Configuration parameters are retained by using battery-backed RAM. Linearisation Multi breakpoint calculation by microprocessor (output is linearised and cold junction compensated) Broken THC indication Serial output drives upscale or downscale Alarm facilities High and low alarms are indicated in the serial data and can be set for each input

3052 DIGITAL ISOLATOR for signals up to 10kHz Hazardous area Safe area 3052 5 1 This unit is similar in principle to the 3042 but operates at a higher frequency for use with digital signals. Its primary application is to provide IS protection for the data highways and s in 800 Series systems. The 3052 features two output circuits: one with a 15V 180 safety description, and an alternative 15V 100 circuit which can be used if higher loop resistances need to be accommodated, for example when surge protectors are incorporated in the data highways. If the low-resistance outputs are used on two units fitted to a dual-highway system however, the s are restricted to location in IIB atmospheres. SPECIFICATION See also 'Common specification' Number of channels One, fully floating Location of load Zone 0, IIC, T4 6 hazardous area if suitably certified Div 1, Group A, hazardous location Zone 0, IIB, T4 6 (Div 1, Group C, hazardous location) for s in dual-highway systems using the low-resistance outputs of two 3052s Input voltage 4 to 12V dc Signal bandwidth dc to 10kHz Minimum output voltage [V in minus (0.25 x current in ma)] V Input and output circuit ripple <1mA peak-to-peak Power dissipation within unit 160mW maximum at 12V with 20mA signal Replaceable fuse 50mA, 5 x 20mm glass to DIN 41571 sht. 2, semi-time-lag (M) No-fail earth fault protection (optional) Enabled by connecting terminal 8 to 2220 Fault on either line proclaimed: unit continues working Safety description Terminals 5 & 6 15V, 100, 150mA, U m = 250V rms or dc Terminals 6 & 7 15V, 180, 83.3mA, U m = 250V rms or dc FM max entity parameters V oc = 15V, I sc = 83.3mA, C a = 0.75µF, L a = 5.2mH Weight 130g 6 To 2220 (optional) Surge protection unit 7 3 8 6 3052 2 5 1 4 2 7 3 8 To 2220 (optional) 4 receiver receiver OTHER APPLICATIONS The 3052 is suitable for a variety of other applications, such as bringing back the status of a hazardous-area mechanical or optotransistor switch, or a magnetic shaft encoder (all via suitable current limiting resistors).