Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms

Similar documents
HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Frequency-based method to optimize the number of projections for industrial computed tomography

Advanced Reconstruction Techniques Applied to an On-Site CT System

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Industrial Radiography Simulation by MCNPX for Pipeline Corrosion Detection

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

Introduction to Biomedical Imaging

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

Translational Computed Tomography: A New Data Acquisition Scheme

CIVA Computed Tomography Modeling

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Deliverable D10.2. WP10 JRA04 INDESYS Innovative solutions for nuclear physics detectors

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

Simulation of Radiographic Testing for POD Assessment

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

3D Computed Tomography (CT) Its Application to Aerospace Industry

Quality control phantoms and protocol for a tomography system

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

Medical Imaging BMEN Spring 2016

Recognition and Measurement of Small Defects in ICT Testing

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DUAL energy X-ray radiography [1] can be used to separate

CIVA CT, an advanced simulation platform for NDT

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

CT Systems and their standards

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste

Simulation of Internal Backscatter Effects on MTF and SNR of Pixelated Photon-counting Detectors

Optimisation of the process of X-ray tomography applied to the detection of defects in composites materials

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Continuation Format Page

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography

Shielding factors for traditional safety glasses

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

Scatter Correction Methods in Dimensional CT

Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation

Image Acquisition Systems

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

Gamma spectroscopic measurements using the PID350 pixelated CdTe radiation detector

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

X-ray simulation and applications

MEDICAL IMAGING 2nd Part Computed Tomography

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

New developments in industrial radiography at EDF

Plane Wave Imaging Using Phased Array Arno Volker 1

Ch. 4 Physical Principles of CT

Intermediate energy x-ray backscatter characteristics from the interaction with macroscopically thick layered media

Characterization of damage mechanisms in glass fibre reinforced polymers using X-ray computed tomography

Comparison of phase contrast X-ray computed tomography methods for non-destructive testing of materials

COMPUTER SIMULATION OF X-RA Y NDE PROCESS COUPLED

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle

DUE to beam polychromacity in CT and the energy dependence

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

Available online at ScienceDirect

Limitations in the PHOTON Monte Carlo gamma transport code

Radiographic Simulator artist: Version 2

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

How beam hardening influences the dimensional geometry in X-ray computed tomography

High Resolution Phased Array Imaging using the Total Focusing Method

2. Combination of eddy current inspection and imaging analysis

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Ultrasonic Multi-Skip Tomography for Pipe Inspection

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

Modeling the Transmission Loss of Passthroughs in Sound Package using Foam Finite Elements

Reconstruction Methods for Coplanar Translational Laminography Applications

Evaluation of 3D fiber orientation analysis based on x-ray computed tomography data

Energy resolved X-ray diffraction Cl. J.Kosanetzky, G.Harding, U.Neitzel

High-resolution X-ray computed tomography of inhomogeneous materials

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY

Digital Image Processing

DAMAGE INSPECTION AND EVALUATION IN THE WHOLE VIEW FIELD USING LASER

STATUS AND FUTURE ASPECTS OF X-RAY BACKSCATTER IMAGING

Modelling I SPECIFIC REQUIREMENTS ON COMPUTER MODELING OF RADIOGRAPHIC INSPECTIONS OF NUCLEAR COMPONENTS

Fits you like no other

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography

Applying Hounsfield unit density calibration in SkyScan CT-analyser

Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation. Wadeson, Nicola and Morton, Edward and Lionheart, William

Application of MCNP Code in Shielding Design for Radioactive Sources

Comparison of fiber orientation analysis methods in Avizo

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

TOLERANCE ANALYSIS OF THIN-WALL CFRP STRUCTURAL ELEMENTS USING TOMOGRAPHIC IMAGING

Enhanced material contrast by dual-energy microct imaging

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

Diffraction. Single-slit diffraction. Diffraction by a circular aperture. Chapter 38. In the forward direction, the intensity is maximal.

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology

Transcription:

11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16395 Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms Philipp SCHUETZ, Iwan JERJEN, Jürgen HOFMANN, Mathieu PLAMONDON, Alexander FLISCH, Urs SENNHAUSER Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf, Switzerland e-mail: schutz.p@gmail.com, iwan.jerjen@empa.ch, juergen.hofmann@empa.ch, mathieu.plamondon@empa.ch, alexander.flisch@empa.ch, urs.sennhauser@empa.ch Abstract High energetic X-ray photons are scattered in both the object and the system s components and cause artefacts in industrial computed tomography (CT). In this contribution, we investigate the influence of individual CT components on environmental scattering by experimentally verified Monte Carlo simulations. An assessment of different configurations indicates a potential reduction in environmental scattering by 81 ± 4 % due to system modifications. The contribution of environmental scattering to the transmission signal displays only a weak spatial variation. Thus, an analytical correction method is suggested, which is applied on the transmission images prior to reconstruction. This procedure requires a single input parameter and is applied on measurements of an industrial CT system operating a source with 450 kv maximum acceleration voltage. The suggested procedure increases the contrast of the central hole in an aluminium step cylinder with a diameter larger than 160 mm by more than a factor of 2.4 compared to non-corrected data. Keywords: Modelling and Simulation, Image Processing, Computed Tomography, X-ray Scattering, Correction Algorithm, Monte Carlo Simulations, Cone-beam Computed Tomography 1. Introduction X-ray computed tomography (CT) is a non-destructive method to inspect samples for defects and deviations in both internal and external structures. Typical applications include the failure analysis of industrial products [1,2], the investigation of structures in the sample [3,4] and dimensional metrology [5]. In conventional industrial CT, the object is rotated around a fixed axis in small angular steps and, in each orientation of the specimen, an X-ray transmission image is recorded [6]. A key assumption for the reconstruction of the tomographic crosssections in classical CT is a linear propagation of the photons from generation to detection. Scattering processes invalidate this assumption and cause a deterioration of the imaging quality due to the detection of scattered photons. For energies exceeding 150 kev, the interaction cross-sections of (in)elastic scattering events dominate those of (photo-electric) absorption processes for most industrially relevant materials [7] highlighting the importance to consider the influence of scattered radiation for medium- and high energy CT applications. Discriminating scattered from non-scattered photons is very challenging in experiments. Therefore, Monte Carlo simulations with established packages such as GEANT4 [8-10] or EGS/Rosi [11] are performed, in which the propagation of the photons through the sample and the system is tracked and thereby the contribution of scattered photons to the detected signal can be quantified. For the CT-system considered in this contribution, a Monte Carlo model was implemented in the GEANT4 framework and experimentally verified [8, 10, 12]. In this contribution, the effect of different system configurations on the distribution of detected scattered radiation is examined with simulations. Based on the results of the simulation study, the system setup has been modified and the results of the experimental verification will be presented. Based on an elementary assessment of the spatial distribution of the scattered radiation, a correction procedure will be presented, which displays a significant improvement of the image quality on the examined test sets.

2. Materials and Methods 2.1 Monte Carlo modelling of X-ray photon propagation with GEANT4 The models for the X-ray propagation are implemented in the GEANT4 framework (version 4.9) as described in [8,12]. The components of the CT scanner are modelled as geometrical primitives employing bulk material properties. For electrons, the following physical processes are activated: ionization, bremsstrahlung and multiple scattering processes. In addition, for photons, models for Rayleigh and Compton scattering as well as for the photoelectric effect are included. The photons are generated at the source location with an energy spectrum adopted from an experimentally verified model of the source assuming 450 kv acceleration voltage and an external filtration of 1.0 mm tungsten [10]. The photons are emitted isotropically in a cone with an opening angle of 7.25 (half-angle). For all simulated photons, the total energy deposited in the scintillator (cesium-iodide with 2 mm thickness) mounted on an aluminium plate of 1 mm thickness is recorded. Furthermore, the total deposited energy from photons scattered in the mirror, in the detector or in the walls is recorded. If the photon is scattered in more than one of these components, the deposited energy is split equally between the interacting parts. In each simulation, the histories of 8. 10 6 or 8. 10 7 photons are analysed (the number of considered photons was increased whenever the statistics was insufficient). The error of the estimated photon numbers is calculated as the standard deviation of the results from 8 independent Monte Carlo runs with a length of one eighth of the total number of events. 2.2 Assessment of influence from different system configurations Two different scintillator supports are considered (a more encompassing set of different configurations is considered in [12]). The different geometries are visualized in Fig. 3. The major differences between the two designs are the liner composition (iron-lead sandwich for the non-optimised setup, carbon fibre reinforced polymers, CFRP, with a thickness of 0.55 mm for the optimised setup) and the geometry (49 x 51 x 32 cm 3 in the initial setup to 58 x 51 x 51 cm 3 in the optimised setup). In the experimental setup, the scintillation light is recorded via a 45 mirror in a CCD camera at the bottom of the detector box. For this mirror two configurations are evaluated: glass matrix with 2.8 mm thickness or a polycarbonate plate (1.5 mm thick). To reduce the effect of backscattering from the walls the unlined walls are compared with a configuration where the walls are lined with a sandwich of tin (1 mm thick) and lead (2 mm thick) or a massive layer of lead (50 mm wall thickness). As test object, an aluminium parallelepiped with 70 x 70 x 190 mm 3 is simulated at a distance of 1107 mm from the source (source-detector distance is set to 1500 mm). 2.3 Spatial variability of environmental scattering contribution To assess the spatial variability of the energy deposited in the scintillator due to environmental scattering a total of 2. 10 9 photon histories are analysed. The sensitive area of the scintillator is split into areas of 0.96 x 0.96 mm 2 (corresponding to a binning factor of four in the experiment) and the deposited energy in the corresponding volume is calculated. To reduce the effect of noise, a Gaussian image filter with a standard deviation of 5 pixels is applied to the simulated transmission image. 2.4 Experimental verification of reduced scattering by system redesign The effect of the instrument redesign is evaluated with a CT scanner (described in detail in [12]) operating an X-ray source with 450 kv maximum acceleration voltage manufactured by Comet (Model MXR-451HP/11/Y). The source spectrum is filtered with a liner of tungsten (alloy HPM1750) with 0.5 mm thickness. The beam is shaped by an additional lead collimator to a vertical aperture of 4 mm for the evaluation of the instrumental redesign or to an angular

aperture of 8.87 x 6.09 (horizontal x vertical) for the assessment of the software correction. In the detector, the scintillation light generated in a Thallium-doped Cesium Iodide scintillator with 2 mm thickness is imaged by a CCD camera (Alta U32 from Apogee Imaging Systems) via a 45 mirror. Both detector setups are shown in Fig. 1. The non-optimised scintillator support is built from liners of lead and steel and described in detail in [8]. The optimised scintillator support is built from liners of CFRP (details given in [12]). For the experimental evaluation of the impact of the system modification, an aluminium step cylinder with levels of outer diameter 40, 60, 80, 100, 120, 160, 200, and 220 mm and a total height of 160 mm in steps of 20 mm is recorded. Along the symmetry axis of the cylinder a hole with 20 mm diameter has been drilled. The sample is positioned at 1107 mm from the source with a source-detector distance of 1500 mm. For the tomographic measurements with the slit collimator, an acceleration voltage of 450 kv and a tube current of 2.9 ma is set (reduced to 2.5 ma during flat field acquisition) to record a total of 720 projections with a total integration time of 8.0 s. The tomograms are reconstructed with the software of the system s supplier based on the Feldkamp-Davis-Kress algorithm [14]. The measurements with a large angular opening are performed with a tube current of 3.3 ma (reduced to 3.0 ma during flat field acquisition) and an integration time of 4.0 s. 2.5 Correction algorithm for remaining environmental scattering The observed low spatial variability of the contribution from environmental scattering (cf. Fig. 4) justifies the two assumptions that the contribution of environmental scattering to the image signal is isotropic and that it is independent of the local signal strength in the presence of the sample or in the absence of the object. Therefore, the measured transmission signal is Defining the environmental transmission as and the actual transmission, we obtain for the actual transmission 1 This correction formula is applied on the transmission images prior to reconstruction. As the reconstruction of the system s supplier did not permit the reconstruction of modified data, an in-house implementation of the Feldkamp-Davis-Kress algorithm was employed for the evaluation of the effect of the correction formula. The parameter may be determined in a binary search process [13]. Evaluations on a broad set of test data indicate that it may be estimated from the projection images, given the projection images do not display an excessive spatial variation [13]. Figure 1: CT-setup prior (left) and after redesign (right). Essential elements of the modified setup are a new scintillator support with larger dimensions from carbon fibre reinforced polymer, a foil mirror (not visible) and the bimetallic liners on the concrete walls.

3. Results and Discussion 3.1 Influence of scintillator support geometry and material The fraction of energy scattered in the environment is displayed for different system configurations in Fig. 2. An exchange of the scintillator support built from steel-lead liners with a larger scintillator support from carbon fibre reinforced polymers permits a substantial reduction of the amount of backscattered radiation. As the beam stopping power of the support is lost upon the exchange, the backscattering of the walls increases substantially. The contribution of the mirror on the other hand is largely constant because the fraction of transmitted primary radiation is unchanged upon the exchange. Evaluating the position where the photons are scattered (cf. Fig. 3) indicates that most photons are scattered in the parts of the support in the primary beam. Exchanging the material of the support liners with lighter materials reduces the radiation scattered in the scintillator support only marginally, but a larger amount of radiation is scattered back by the walls [12]. Increasing the dimensions of the box permits a substantial reduction of the scattering. Therefore, in the new setup the dimensions of the box are increased and the liners are exchanged by CFRP. Figure 2: Fraction of scattered radiation detected in scintillator for different configurations. Starting point is the initial, nonoptimised setup as depicted in Fig. 1 (left). An exchange of the scintillator support yields a significant reduction of the scattered radiation, whereas the contribution of the walls increases due to the loss of the strong beam stopping power of the scintillator support. The contribution of scattered radiation may be further reduced by exchanging the mirror and lining of the walls. Figure 3: Number of photons depositing energy in the scintillator and scattered in individual parts of the detector. (left) Nonoptimized detector design with steel-lead liners (right) Detector designed for reduced environmental scattering. Key features of the new detector are the increased geometric dimensions as well as the replacement of dense materials in the primary beam by thin liners of carbon fibre reinforced polymers (CFRP).

3.2 Optimisation of mirror support and wall lining Lining the walls with thick layers of lead (50 mm thickness) reduces the backscattering from the walls less effectively than a bimetallic liner of 1 mm tin and 2 mm lead. This bimetallic liner material outperforms all other combinations examined elsewhere [12] for the given setup, source energy and filtration. Please note here that for different applications another combination might be more effective. Besides the scintillator support and the walls, the mirror causes substantial backscattering. In simulations, an substitution of the glass support of the mirror (thickness 2.8 mm) with a polycarbonate liner of 1.5 mm thickness reduces the back scattering contribution by 70 %. The reflective layer (thickness 20 µm) has only a marginal influence [12]. In the experiment, the mirror with the glass support was exchanged with a mirror based on a reflective foil. Compared to the initial setup, the contribution of radiation scattered in the environment is reduced by 81 ± 4 % if both the scintillator support and the mirror matrix are exchanged and the walls are lined with the bimetallic layers. Besides the total contribution of scattered radiation to the deposited energy in the scintillator, the spatial distribution is investigated (cf. Fig. 4). Remarkably, the distribution of environmentally scattered radiation displays only a small spatial variation. The increase of the strength at a higher vertical position may be explained by the shorter distance of these scintillator parts to the mirror. Figure 4: Vertical profile through simulated transmission image of an aluminium parallelepiped with 19 cm depth. Compared is the total transmission signal with the contribution of signal arising from detected photons scattered in the environment. The environmental scattering displays only a marginal spatial dependence, which may be attributed to the fact that at a higher vertical position the mirror is substantially closer to the scintillator than at a lower position. 3.3 Experimental validation In Fig. 5, a cross-sectional cut through the step with a diameter of 160 mm is compared for both setups. The grey level profile of the optimised measurement indicates an improved contrast and displays less noise compared to the analogous profile from the measurement of the non-optimised setup. Quantitatively, the contrast C is calculated here as with the average grey value in the profile of Fig. 5.c) for positions with an absolute value between 15 mm and 25 mm and the average grey value for positions with an absolute value below 5 mm from the centre of the hole. For the nonoptimised setup, this yields a contrast value of 1.4±0.3 and, for the optimised setup, a value of 1.9±0.3 is determined, which corresponds to an increase of 36 %. This improvement of the contrast is in agreement with the reduction of environmental scattering predicted in-silico [12].

a) b) c) Figure 5: Tomogram comparison of an aluminium step cylinder (diameter 160 mm) with original and optimised setup. a) Non-optimised setup b) Optimised setup c) comparison of grey value profile (average over 5 pixels) through center of the slice. The labels refer to the system setup before and after the optimisation. The X-ray beam is shaped by a slit collimator with 4 mm vertical opening. 3.4 Effect of algorithmic scatter correction on image contrast Although the instrumental redesign reduces environmental scattering substantially, the tomographic slices through the larger steps still display cupping artefacts (cf. Fig. 6 (left)). Applying the correction formula derived in section 2.5 with an optimised value of the scattering contribution corrects most of the cupping artefacts (cf. Fig. 6 (right)). The largest two steps display a high level of noise in the image grey values, which arises from the strong influence of noise on the logarithm of the transmission value (input for the reconstruction process) [13]. A common quality criterion for the reconstruction image is how much the grey values in the hole recover the grey value of air. As a figure of merit, the contrast! with and defined as in section 3.3 is considered (the attenuation of air is assumed to be 0) and the values displayed in Table 1 are obtained. All contrast values for the corrected measurements outperform the corresponding values of the non-corrected measurement. For the steps with more than 160 mm diameter, the contrast increases by more than a factor of 2.4. A draw-back of the correction procedure is that the noise in the grey level profiles increases (manifest by the increased standard deviation of the contrast values). An analysis of the influencing factors on the optimum value of the scattering contribution indicates that for a large class of objects the parameter may be estimated from the projection data [13]. Figure 6: Comparison of tomographic slice through aluminium step cylinder with non-corrected data, but optimised setup (left) and corrected data (right). To examine the effect on the complete cylinder, this measurement has been performed with the lead collimator permitting an angular opening of 8.87 x 6.09 (horizontal x vertical).

Table 1: Step height values extracted for the aluminium step cylinder prior and after correction (cf. Fig. 6). Contrast Level Non-corrected Corrected 40 0.93 ± 0.07 0.95 ± 0.05 60 0.923 ± 0.007 0.967 ± 0.006 80 0.845 ± 0.008 0.953 ± 0.006 100 0.73 ± 0.01 0.922 ± 0.009 120 0.59 ± 0.01 0.90 ± 0.01 160 0.30 ± 0.02 0.72 ± 0.04 200 0.13 ± 0.03 0.42 ± 0.09 220 0.09 ± 0.04 0.28 ± 0.12 4. Conclusion Medium and high energy X-ray computed tomography may suffer from artefacts caused by radiation scattered in the object and the environment. In this paper, the contribution of the system components to environmental scattering is investigated and a simple correction procedure for the contribution of (environmental) scattering is evaluated. Optimising the system components for low environmental scatter permits a reduction of environmental scattering by more than 80 %. Key element for this reduction is to remove as much as possible elements from the primary beam, build the exposed elements by light materials permitting low wall thicknesses (such as carbon fibre reinforced polymers) and by lining the wall with bimetallic liners reducing the backscatter (in our study a combination of 1 mm tin and 2 mm lead outperformed the other combinations). For the optimised setup, the contribution of the environmental scattering for the investigated object is mostly spatially isotropic. To correct these scattering contributions, a simple procedure based on the assumption of a constant background is presented, which is applied on the projection images prior reconstruction. An evaluation of different test samples indicates that the estimation of the background strength has a strong influence on the effect of the correction. This observation explains why the substantial reduction of the environmental scattering by the system redesign yields a mediocre numerical improvement of the contrast. But for a substantial improvement of the image quality, the combined action of system redesign and correction algorithm is required.

References [1] I. Jerjen, et al., Detection of stress whitening in plastics with the help of x-ray dark field imaging, Polymer Testing 32:1094 1098, 2013. [2] P. Jacob, I. Jerjen, G. Nicoletti, Root-cause investigations of stitch bond shearing by means of 3D-X-ray computer tomography (XCT), metallographic polishing and FIB. In: 36 th international symposium for testing and failure analysis, 2010. [3] L. M. Keller, et al., Characterization of multi-scale microstructural features in opalinus clay, Microporous and Mesoporous Materials 170:83 94, 2012. [4] P. Schuetz, et al., Quantitative comparison of the eye formation in cheese using radiography and computed tomography data, International Dairy Journal 31:150 155, 2013. [5] S. Carmignato, Accuracy of industrial computed tomography measurements: Experimental results from an international comparison, CIRP Annals - Manufacturing Technology 61:491 494, 2012. [6] A. C. Kak, S. Malcom, Principles of computerized tomographic imaging, IEEE Press, Philadelphia, PA, USA, 1988. [7] C. T. Chantler, Theoretical Form Factor, Attenuation, and Scattering Tabulation for Z=1-92 from E=1-10 ev to E=0.4-1.0 MeV, Journal of Physical and Chemical Reference Data 24:71 643, 1995. [8] A. Miceli, et al., Monte Carlo simulations of a high-resolution X-ray CT system for industrial applications, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 583:313 323, 2007. [9] S. Agostinelli, et al., G4 a simulation toolkit, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 506, 250 303, 2003. [10] A. Miceli, et al., Comparison of simulated and measured spectra of an industrial 450 kv X-ray tube, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 580, 123 126, 2007. [11] J. Giersch, A. Weidemann, G. Anton, ROSIan object-oriented and parallel computing Monte Carlo simulation for X-ray imaging, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 509:151 156, 2003. [12] P. Schuetz, A. Miceli, I. Jerjen, A. Flisch, J. Hofmann, R. Broennimann, et al., Reducing environmental scattering in industrial computed tomography by system redesign. NDT and E Int 58:36 42, 2013. [13] P. Schuetz, I. Jerjen, J. Hofmann, M. Plamondon, A. Flisch, U. Sennhauser, Correction algorithm for environmental scattering in industrial computed tomography, NDT and E Int 64:59-64, 2014. [14] L. A. Feldkamp, L. C. Davis, J. W. Kress, Practical cone-beam algorithm, J. Opt. Soc. Am. A 1: 612 619, 1984.