Delta T Dew Heater for CDK

Similar documents
IRF90 - Rotating Focuser

Installation Instructions

The basic product comes with the IRS5 control board, 3 internal cables, 1 external cable with a 5 volt adapter and a mounting bracket with hardware.

PlaneWave CDK12.5 Astrograph f/8 with Borosilicate Optics, 3" Dovetail, Delta T Ready, 3,5" Hedrick Focuser (without EFA Kit)

Seeburg JCU-DEC Kit Convert Your Seeburg DEC Wallbox Into a Jukebox

Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #

Blue Point Engineering

Camera Features. Package Contents. Camera Features

700TSU INSTALLATION MANUAL

midi LOGGER 900 SERVICE MANUAL GL900-UM-251 GL900-UM

IncroMAXX Transit. Installation Guide Lake Forrest Drive Suite 410 Atlanta, GA

MultiConnect Adapters

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

Lightning Stitch Assembly

SMM501/501-H (Surveillance Mode Module) Ford Police Interceptors (Sedan and SUV)

1020 / 1022 INSTALLATION MANUAL

xtablet T1600 Vehicle Holder Installation Guide

Custom O2+ODAC Soldering Instructions

VERSION 1.1 SEPTEMBER 12, 2017 ULTIMATE POWERBOX PRODUCT MANUAL BY PEGASUS ASTRO [COMPANY ADDRESS]

2M Outdoor Motorized Bullet Camera

TracKing for Precedent Single Temperature and Multi-Temperature Installation Instructions

midi LOGGER 820 GL820-UM-251

Touch Sense Controller

HUAWEI FT2260 Home Phone Connect Quick Start

INSTALLATION INSTRUCTIONS MODEL MRC44KP MRC44 KEYPAD

Hyper Stimulator Set Up Instructions

ELITE Test Systems. /Quick Start Wiring. Botron Company Inc.

INSTALERT VARIABLE MESSAGE SIGN

Lab 4: Trajectory Following 1

VC2100 / VC MB Digital Event Recorder

PRODUCT SPECIFICATION

Installing Keypad and Backplate

midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

Larson Systems Inc. FLASH 48 Parts List ,000 lb Whisper Drive ,200 lb Whisper Drive A

midi LOGGER 220 GL220-UM-251

64-Ch Windows-based NVR. with 8-Bay Hard Disks NVR-E6480. Quick Installation Guide

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

1029 INSTALLATION MANUAL

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

LED Maintenance Instructions

GL2200 MIXING CONSOLE

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

P160 User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

Floor Standing Pedestal

Humidity/Temperature Sensor

!!!---WARNING---!!! 2011 DYNOJET RESEARCH ALL RIGHTS RESERVED FOR RACING VEHICLE USE ONLY

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

12 Options 12.1 CTIU OPERATOR INTERFACE UNITS

10/100Base-TX Industrial Ethernet Extender

EASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations

1. Introduction 1.1.Product Overview

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

WIFI TOUCH PANEL WALL CONTROL F-TS

Global Plasma Solutions. 10 Mall Terrace, Bldg C Savannah, GA (912) ph (877) fax

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Butterfly Laser Diode Mount

PRODUCT SPECIFICATION

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

LVS 7500 External System Installation and Quick Start Guide

DYNAVISION D2 TM INSTALLATION MANUAL

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

705 INSTALLATION MANUAL

4200 Model # - C Controller Instruction Manual V.3.1. This instruction manual serves as a guide for the 4200 Controller.

D/E Remote Relay Panel User Guide

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

HOME THEATER PC CHASSIS

PT Teleprompter

Please take serious note of the following warnings:

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

User Guide Diamond Drive Cartridge System DDCSSAS / DDCSIS DDCSSAU / DDCSIU

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

527F Dual PC Option Installation Guide as replacement for 32MP made by Fadal

The Dimmer III Package Dimensioner Setup Manual

Accsense Wireless System. Temperature Monitor

QUICK START INSTALLATION GUIDE

Profinet Set in IP20 TI-BL20-E-PN-4

Operating Instructions for Memo-Chip BL2

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014

Hygro-Thermometer / Datalogger

ProMinder Standard Heating System Installation Instructions

M350. Embedded Mini-ITX Enclosure. Installation Guide Version 1.0

VMC Touch: Mounting Monitor Bracket Ports Connection And Cables Installation

IEI emerge MicroNode Install and Setup Guide. Contents

Diamond Systems Hercules II Single Board Computer FastStart Guide

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

R e f U S U S E R M A N U A L

IP68 Sealed - Mini USB Buccaneer

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

S7999D SOLA Operator Interface Display

4100/ VDC Converter Installation Instructions

Programmable Controller IC697ACC721/724/744

Pandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006

Transcription:

Delta T Dew Heater for CDK Delta T Dew Heater for CDK12.5 (125902) Your CDK 12.5 Delta T Dew Heater includes the following: QTY 1 Delta T control box w/ mounting bracket attached 1 2.5Amp AC adapter 2 RCA Cables 1 Temp cable (phone jack on both ends) 1 USB cable 2 Mounting Screws 1 USB Flash Drive with PWI Software 1 Instruction Sheet *Delta T Dew Heater is only compatible with CDK telescopes that are equipped with pre installed heaters on the primary and secondary mirrors. Mounting the Delta T Control onto your CDK Telescope The Delta T control box attaches to any of the mounting holes around the outside of the telescope s back plate. Use the included ¼ 20 screws the thread the L bracket attached to the control box to the corresponding mounting holes on the telescope back plate. Fig 1 Delta T Control box with mounting bracket and screws Attaching the Cables CDK 12.5 Your Delta T controller comes with two RCA cables for connecting to the heaters installed in the CDK telescope. Also included is a cable to connect to the telescope s temperature sensors, and a USB to connect to a PC. 1. Connect one end of the RCA cable to the port marked PRI on the back of the telescope (see Fig 2) and connect the other end to the port labeled Primary on the control box (see Fig 4). 2. Connect one end of the RCA cable to the port marked SEC on the back of the telescope and connect the other end to the port labeled Secondary on the control box. 3. Connect one end of the phone jack cable to the port marked TEMP on the back of the telescope (see Fig 2) and connect the other end to the port labeled Temp on the control box (see Fig 4). 4. Connect the USB cable to the port marked USB on the front of the control box (see fig 3) and connect the other end to your PC. Note: remember that you must always connect the Temp cable as described in step #3 before plugging in the USB cable. Otherwise the PWI3 software may not be able to detect the temperature sensors attached to the mirrors.

5. Now power on the control box by connecting the barrel connector of the AC adapter to the 12vDC port on the control box (fig 3). 6. Turn the power switch on the control box to the on position and check that the red LED light comes on (see fig 3). NOTE: The power on the telescope s electronics panel does not need to be on in order for the dew heater to work. However the EFA box will need to be on and connected in order to read the primary mirror and ambient temperature sensors Fig 2 Electronics panel on back plate of CDK12.5 Fig 3 Front electronics panel on the Delta T controller Fig 4 Rear electronics panel on the Delta T controller

Delta T Dew Heater for CDK14 (600195) Your CDK14 Delta T Dew Heater includes the following QTY 1 Delta T control box w/ mounting bracket attached 1 AC Adapter 12V, 5Amp 2 RCA Cables 1 Secondary Output cable 1 Temp cable (phone jack on both ends) 1 USB cable 2 Mounting Screws 1 USB Flash Drive with PWI Software 1 Instruction Sheet *Delta T Dew Heater is only compatible with CDK telescopes that are equipped with pre installed heaters on the primary and secondary mirrors. Mounting the Delta T Control onto your CDK Telescope The Delta T control box attaches to any of the mounting holes around the outside of the telescope s back plate. Use the included ¼ 20 screws the thread the L bracket attached to the control box to the corresponding mounting holes on the telescope back plate. Attaching the Cables CDK 14 Your Delta T controller comes with two RCA cables for connecting to the heaters installed in the CDK telescope. Also included is a cable to connect to the telescope s temperature sensors, and a USB to connect to a PC. Fig 5 Delta T Control box with mounting bracket and screws 1. Locate the Secondary Output Cable that has a Turck connector at one end and two Molex connectors (two pin and three pin). a. Connect the two pin and three pin Molex connectors to the corresponding connectors on the cable coming from secondary assembly (see Fig 6). b. Connect the other end to the port labeled Secondary Output on the back of the telescope. (see Fig 7)

Fig 6 Secondary Output Connectors Fig 7 Secondary Output Port 2. Connect one end of the RCA cable to the port marked PRI on the back of the telescope (see Fig 8) and connect the other end to the port labeled Primary on the control box (see Fig 10). 3. Connect one end of the RCA cable to the port marked SEC on the back of the telescope and connect the other end to the port labeled Secondary on the control box. 4. Connect one end of the phone jack cable to the port on the back of the telescope (see Fig 8) and connect the other end to the port labeled Temp on the control box (see Fig 10). 5. Connect the USB cable to the port marked USB on the front of the control box (see Fig 9) and connect the other end to your PC. Note: remember that you must always connect the Temp cable as described in step #3 before plugging in the USB cable. Otherwise the PWI3 software may not be able to detect the temperature sensors attached to the mirrors. 6. Now power on the control box by connecting the barrel connector of the AC adapter to the 12vDC port on the control box (Fig 9). 7. Turn the power switch on the control box to the on position and check that the red LED light comes on (see Fig 9). NOTE: The power on the telescope s electronics panel does not need to be on in order for the dew heater to work. However the EFA box will need to be on and connected in order to read the primary mirror and ambient temperature sensors Fig 8 Electronics panel on back plate of CDK14

Fig 9 Front electronics panel on the Delta T controller Fig 10 Rear electronics panel on the Delta T controller

Delta T Dew Heater for CDK17 & 20 (170902/200902) Your CDK17/20 Delta T Dew Heater includes the following: QTY 1 Delta T control box w/ mounting bracket attached 1 AC Adapter 12V, 5Amp 2 RCA Cables 1 Temp cable (phone jack on both ends) 1 USB cable 2 Mounting Screws 1 USB Flash Drive with PWI Software 1 Instruction Sheet *Delta T Dew Heater is only compatible with CDK telescopes that are equipped with pre installed heaters on the primary and secondary mirrors. Mounting the Delta T Control onto your CDK Telescope The Delta T control box attaches to any of the mounting holes around the outside of the telescope s back plate. Use the included ¼ 20 screws the thread the L bracket attached to the control box to the corresponding mounting holes on the telescope back plate. Fig 11 Delta T Control box with mounting bracket and screws Attaching the Cables CDK 17/20 Your Delta T controller comes with two RCA cables for connecting to the heaters installed in the CDK telescope. Also included is a cable to connect to the telescope s temperature sensors, and a USB to connect to a PC. 8. Connect one end of the RCA cable to the port marked PRI on the back of the telescope (see Fig 12) and connect the other end to the port labeled Primary on the control box (see Fig 14). 9. Connect one end of the RCA cable to the port marked SEC on the back of the telescope and connect the other end to the port labeled Secondary on the control box. 10. Connect one end of the phone jack cable to the port on the back of the telescope (see Fig 12) and connect the other end to the port labeled Temp on the control box (see Fig 14). 11. Connect the USB cable to the port marked USB on the front of the control box (see Fig 13) and connect the other end to your PC. Note: remember that you must always connect the Temp cable as described in step #3 before plugging in the USB cable. Otherwise the PWI3 software may not be able to detect the temperature sensors attached to the mirrors.

12. Now power on the control box by connecting the barrel connector of the AC adapter to the 12vDC port on the control box (Fig 13). 13. Turn the power switch on the control box to the on position and check that the red LED light comes on (see Fig 13). NOTE: The power on the telescope s electronics panel does not need to be on in order for the dew heater to work. However the EFA box will need to be on and connected in order to read the primary mirror and ambient temperature sensors Fig 12 Electronics panel on back plate of CDK17/20 Fig 13 Front electronics panel on the Delta T controller Fig 14 Rear electronics panel on the Delta T controller

Delta T Dew Heater for CDK24 (240902) Your CDK24 Delta T Dew Heater includes the following: QTY 1 Delta T control box w/ mounting bracket attached 1 AC Adapter 12V, 5Amp 1 Primary Heater Cable (PH) 1 Temperature Cable (TEMP) 1 USB cable 2 Mounting Screws 1 USB Flash Drive with PWI Software 1 Instruction Sheet Attaching the Cables CDK 24 Your Delta T controller comes with two cables for connecting to the CDK telescope. One cable has a RCA connector at one end and a 2 pin connector (labeled PH, for Primary Heater ). The second cable has a phone jack connector at one end and the 3 pin connector (labeled TEMP ) at the other end. There is also another RCA cable that is already attached to the scope, that will connect directly to the control box. 1. Connect one end of the RCA cable to the port marked PRIMARY HEATER on the Delta T control box, and connect the other end (labeled PH ) to the wire connector (Labeled PH ) attached to your telescope. See Fig 15 2. Connect one end of the phone jack cable to the port Fig 15 Primary heater connection marked TEMP on the control box and connect the other end to the wire connector (labeled TEMP ) attached to your telescope. See Fig 16 3. Locate the RCA cable that is pre attached to the telescope and connect it to the port labeled Secondary Heater on the control box. 4. Connect the USB cable to the port marked USB on the control box and connect the other end to your PC. Note: remember that you must always connect the Temp cable as described in step #2 before plugging in the USB cable. Otherwise the PWI3 software may not be able to detect the temperature sensors attached to the mirrors. Fig 16 Temperature cable connection 5. Now power on the control box by connecting the barrel connector of the AC adapter to the 12vDC port on the control box.

6. Turn the power switch on the control box to the on position and check that the red LED light comes on. Delta T Control Box Installing the Drivers Once the Delta T controller is powered on and plugged in to a USB port, it should be detected as a new device. If your computer cannot automatically find the correct drivers, search the USB driver folder on the memory stick provided with the Delta T. Installing PWI3 Software In order to control your heater remotely, you must first install the PlaneWave Interface software (PWI3). Plugin the USB memory stick that was included with your heater, and run the Setup_PWI3_1000.exe file. Follow the installation wizard instruction to complete the installation. Once installed you should see the PWI3 icon appear on your computer s desktop. Double click the icon to start the program. Controlling the Delta T Heater NOTE: When controlling the heater using the PWI3 software, the primary and secondary control switches (see fig 4) should be switched off so that the red LED lights are not on. For complete instructions on how to use the software features, refer to the Help file under the Help menu of the software. Using Delta T Manually You can also use the Delta T heater independently of the PWI3 software or a computer. With the control box connected as described above, flip the heater control switches (see fig 4 ) so that the red LED lights come on. This will turn both the primary and secondary heaters on to 100% power until the control switches or power switch is turned off.