Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Similar documents
SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Datasheet - SRB 402EM-24V

Datasheet - SRB 301LC/B-24V

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Datasheet SRB301ST 24V (V.2)

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

E-STOP relay, safety gate monitor

safety Product Range Safe System Solutions for Automation Technology

PHOENIX CONTACT Features

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

E-STOP relays, safety gate monitors

PNOZ s1. Safety relays. Operating Manual EN-07

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Contact protection relay

Datasheet - SLB 200-C04-1R

E-STOP relays, safety gate monitors

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PHOENIX CONTACT - 07/2006

PSR UC/ESAM4/3X1/1X2/B

QUINT-PS/ 1AC/24DC/ 5

ITEM ESM-BA301

E-STOP relays, safety gate monitors

Bulletin 817 Thermistor Protection Relay

E-STOP relays, safety gate monitors

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

PNOZ s2. Safety relays. Operating Manual EN-07

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

E-STOP relays, safety gate monitors

Safe monitoring relays

Safe timer relay/contact expansion modules

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Extract from the online catalog

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Faults on the system Proximity switch connection technology:

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

ISOMETER isoev425 with coupling device AGH420

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

ISOMETER isoev425/isoev425hc with coupling device AGH420

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

SIMOCODE 3UF Motor Management and Control Devices

Electronic timer CT-ERS.21

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

E-STOP relays, safety gate monitors

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Thermistor motor protection relay CM-MSS.21

QUINT-PS AC/24DC/10

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Non-Contact Safety System CES-AZ

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Electronic timer CT-ERD.12

Electronic timer CT-ARS.11

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Safety automation solutions

E-STOP relays, safety gate monitors

PHOENIX CONTACT - 01/2007

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

PNOZ s9. Safety relays. Operating Manual EN-08

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

ISOMETER isopv with coupling device AGH-PV

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Thermistor motor protection relay CM-MSS.41

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

safety Safety Products Safety for all applications E 03/07 Downloaded from Elcodis.com electronic components distributor

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Transcription:

EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0 3 Enabling paths, 1 signalling path Feedback loop to monitoring external contactors Device styles SNZ 4003K with screw terminals SNZ 4003K-A with plug-in terminals Description of Device and Function The Device is a single-channel safety switching device for emergency stop equipment conforming to EN 60204-1, with self-monitoring on each ON-OFF cycle and positively driven relays. The device has two reset inputs, Y2 (without reset monitoring) and Y3 (with reset monitoring). The two relays, K1 and K2, are activated automatically (bridge Y1-Y2) or by operating the reset button (on Y1-Y3). They switch to self-maintaining via their own contacts, if there is an electrical connection (emergency stop button, position switch) between terminal A1 and the supply voltage. After this switch-on phase the enabling current paths are closed and the signalling current path is open. If the electrical connections between terminal A1 and the supply voltage are interrupted, the enabling current paths open and the signalling current path closes. The excitation condition (self-maintaining) of the two channels is indicated by a green LED K1, K2. A second green LED indicates the presence of supply voltage. Emergency stop equipment can be constructed to stop category 0 (EN 60204-1). The device corresponds to category 4 for safety-related parts of controllers (EN 954-1). Proper Use The device is for monitoring sensors (e.g. emergency stop buttons, position switches) that are used as part of the safety equipment of machines for the purpose of protecting people, material and machinery. Notes The safety category acc. to EN 954-1 depends on the external circuitry, the choice of control devices and their location on the machine. Expansion devices or external contactors with positively driven contacts can be used to duplicate the enabling current paths. The device and the contacts must be protected at max. 8 A. The emergency stop chain must be closed before the reset button is activated. If magnetic switches with reed contacts or sensors with semiconductor outputs are connected the input peak current must be noticed (see Technical Data). Please observe instructions from safety authorities. 1/6

Function diagram for manual start (restarting lockout) with reset monitoring (Installation 2) A1, LED SUPPLY Y3 K1/K2, LED K1/K2 13/14, 23/24, 33/34 41/42 tb = ready time, ta2 = operate time, tm = minimum switch-on time, tr = release time, tw = recovery time Function diagram for automatic start (Installation 1) A1, LED SUPPLY Y2 K1/K2, LED K1/K2 13/14, 23/24, 33/34 41/42 ta1 = operate time, tr = release time, tw = recovery time Installation 1 1.1 Please consult the connection diagram during installation. 1 Emergency stop, single-channel, automatic reset (1.1) 2 Emergency stop, single-channel, manual reset (2.1) L1 (L+) 2 A1 2.1 Y1 Y2 3 3 enabling current paths (NO) 1 signalling current path (NC) 4 Power supply PE for AC devices only L1 (L+) A1 Y1 Y3 3 13 23 33 41 4 A1 L1 (L+) (M) N PE 14 24 34 42 A2 2/6

Connection Diagrams AC/DC 24 V AC 115-120 V / AC 230 V 3/6

Application Examples L+ E-Stop Not-Aus S2 Reset A1 A1 Y1 Y2 13 23 33 Y3 A1 A2 Y1 Y2 Y3 13 23 33 41 Emergency-Stop Application, single channel, manual start with Reset button monitoring The single channel application complies with the requirement of the stop category 0 acc. to EN 60204-1 and the safety category 2 acc. EN 954-1. However the circuit of the emergency-stop button is not redundant. Ground faults in the emergency-stop circuit are immediately detected. Power supply DC 24 V SUPPLY RESET CONTROL-LOGIC K1 K2 41 42 A2 A2 14 24 34 42 14 24 34 M Door closed Tür geschlossen L1 A1 A1 Y1 Y2 13 23 33 Y3 A1 A2 Y1 Y2 Y3 13 23 33 41 Safety Gate Application, single channel, automatic start The single channel application complies with the requirement of the stop category 0 acc. to EN 60204-1 and the safety category 2 acc. EN 954-1. However the circuit of the safety gate is not redundant. Ground faults in the safety gate circuit are immediately detected. Power supply AC 230 V SUPPLY RESET CONTROL-LOGIC K1 K2 41 42 A2 A2 14 24 34 42 14 24 34 N PE 4/6

Technical Data Power circuit Rated voltage UN AC/DC 24 V AC 115-120 V AC 230 V Rated power DC 1.3 W 2.0 W / 2.3 VA 2.0 W / 2.3 VA AC 1.8 W / 3.2 VA Residual ripple 2.4 VSS -- -- Rated frequency AC 50 to 60 Hz Operating voltage range 0.85 to 1.1 x UN Isolation supply circuit / control circuit No Yes Yes Input peak current (A1) AC 1,6 A / DC 1,2 A -- -- Rated short-circuit current 1400 ma -- -- Protection for control circuit supply PTC thermistor Short-circuit-proof transformer Short-circuit-proof transformer Operate time / recovery time 2 s / 3 s -- -- Control circuit Rated output voltage to supply input Y2 Conductor resistanc in Y1-Y2 / Y1-Y3 ( at UN, regardless of supply voltage) Rated current inputs Y2, Y3 Release time t R with emergency stop K1, K2 Operate time (Y3) t A2 K1, K2 Operate time (Y2) t A1 K1, K2 Recovery time tw Ready time tb Minimum ON time tm on Y3 DC 24 V 70 Ω 15 ma 60 ms 50 ms 180 ms 200 ms 300 ms 50 ms Output circuit Contact equipment 3 enabling current paths with positively driven contacts (NO), 1 signalling current path (NC) Rated switching voltage Un AC/DC 230 V Max. continuous current In per current path NO/NC 8 A / 5 A Max. total current for all current paths 12 A 8 A 8 A Utilization category according to IEC 947-5 - 1 AC-15: Ue 230 V, Ie 4 A (360 h -1 ) DC-13: Ue 24 V, Ie 4 A (360 h -1 ) AC-15: Ue 230 V, Ie 3 A (3600 h -1 ) DC-13: Ue 24 V, Ie 2.5 A (3600 h -1 ) Mechanical service life 10 x 10 6 switching operations short-circuit protection, fuse max. 8 A General data Clearance/creepage distance between circuits to DIN VDE 0110 Part -1: 04.97 depending on device version, see Isolation supply circuit Overvoltage category III Rated impulse withstand level 4 kv Rated voltage AC 300 V Power-frequency test voltage 2 kv Contamination level of device: inside / outside 2 / 3 Climatic application class H V G to DIN 40040: 04.87 Prootection class to DIN VDE 0470 Part 1. Housing / terminals IP 40/IP 20 Ambient / storage temperature -25... +55 / -25... +75 C Weight 0.20 kg 0.25 kg 0.25 kg Terminals and connection Single-core or finely stranded 1 x 0.14 mm² to 2.5 mm² 2 x 0.14 mm² to 0.75 mm² Stripping length max. 8 mm Finely-stranded with wire-end ferrule to DIN 46228 1 x 0.25 mm² to 2.5 mm² 2 x 0.25 mm² to 0.5 mm² Max. tightening torque 0.5 to 0.6 Nm 5/6

Assembly 1 Attach device to DIN rail. 2 Press carefully onto the DIN rail (in direction of arrow) until it locks into place. Disassembly 3 Push down (in direction of arrow) 4 Release and remove it from the DIN rail (see arrow) Dimension Diagram -A Subject to changes SCHLEICHER Electronic GmbH & Co. KG Pichelswerderstraße 3-5 D-13597 Berlin Germany Phone +49.30.33005.0 Fax +49.30.33005.344 Hotline +49.30.33005.304 Internet: http://www.schleicher-electronic.com email: info@schleicher-electronic.com 6/6