Computational modelling and analysis: IOP Medical Physics Group

Similar documents
Real-time monitoring of linac performance using RT plans and logfiles

Dynalog data tool for IMRT plan verification

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

ADVANCING CANCER TREATMENT

Verification of dynamic and segmental IMRT delivery by dynamic log file analysis

ADVANCING CANCER TREATMENT

Advanced Radiotherapy

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

FAST, precise. qa software

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

Using a research real-time control interface to go beyond dynamic MLC tracking

Initial Clinical Experience with 3D Surface Image Guidance

Dose Calculation and Optimization Algorithms: A Clinical Perspective

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Virtual Phantoms for IGRT QA

Machine and Physics Data Guide

Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: Implications for 4D radiotherapy

Version 5.6. Quick Start Guide

Evaluation of fluence-based dose delivery incorporating the spatial variation of dosimetric leaf gap (DLG)

7/29/2017. Making Better IMRT Plans Using a New Direct Aperture Optimization Approach. Aim of Radiotherapy Research. Aim of Radiotherapy Research

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

Dosimetric impact of the 160 MLC on head and neck IMRT treatments

Calibration and quality assurance for rounded leaf-end MLC systems

Radiation therapy treatment plan optimization

3DVH FAQs. What is PDP questions

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

DoseLab for TomoTherapy. AAPM Task Group 148 Background

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Image Guidance and Beam Level Imaging in Digital Linacs

IMRT site-specific procedure: Prostate (CHHiP)

Laser Systems for Patient Alignment

Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)

State-of-the-Art IGRT

Experiences of daily use of a database for linear accelerator quality control

Quality assurance of a helical tomotherapy machine

The MSKCC Approach to IMRT. Outline

Customer Release Notes RTC Software Patch 2.1.1

PyCMSXiO: an external interface to script treatment plans for the Elekta CMS XiO treatment planning system

Radiation therapy plan checks in a paperless clinic

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

I. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital

Iterative regularization in intensity-modulated radiation therapy optimization. Carlsson, F. and Forsgren, A. Med. Phys. 33 (1), January 2006.

arxiv: v1 [physics.med-ph] 26 Oct 2009

Table of Contents. About AQUA

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility

Analysis of RapidArc optimization strategies using objective function values and dose-volume histograms

A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy a

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 3, SUMMER 2006

Open-source software for collision detection in external beam radiation therapy Vinith M. Suriyakumar, Renee Xu, Csaba Pinter, Gabor Fichtinger

VARIAN TREATMENT DELIVERY CONSOLE DICOM CONFORMANCE STATEMENT. Version 2.0 P A MAY L4472 Rev 06

Optimization approaches to volumetric modulated arc therapy planning

An Optimisation Model for Intensity Modulated Radiation Therapy

Quick Reference Datasheet For All RIT113 Packages

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

Online External Beam Radiation Treatment Simulator

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Intensity-modulated radiation therapy dose maps: the matchline effect

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

Modulation factors calculated with an EPID-derived MLC fluence model to streamline IMRT/VMAT second checks

LUP. Lund University Publications. Institutional Repository of Lund University

A comparative analysis for verification of IMRT and VMAT treatment plans using a 2-D and 3-D diode array

CARS 2008 Computer Assisted Radiology and Surgery

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

An experimental comparison of conventional two-bank and novel four-bank dynamic MLC tracking

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

Clinical implementation of photon beam flatness measurements to verify beam quality

PCRT 3D. Scalable Architecture System. User-Friendly. Traceable. Continuos Development

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

MR-guided radiotherapy: Vision, status and research at the UMC Utrecht. Dipl. Ing. Dr. Markus Glitzner

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience

Walk Through of CERR Capabilities. CERR: Introduction. Outline. Getting CERR: Control Panel. Documentation Support Community

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Plan Content (TDPC) Rev. 1.1 Trial Implementation

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Integrated proton-photon treatment planning

TOMOHD. Product Specifications

A method to reconstruct and apply 3D primary fluence fortreatment delivery verification

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine

OPTIMIZATION MODELS FOR RADIATION THERAPY: TREATMENT PLANNING AND PATIENT SCHEDULING

Secondary 3D Dose QA Fully Automated using MOSAIQ's IQ Engine. MOSAIQ User Meeting May Antwerp

Transcription:

Computational modelling and analysis: IOP Medical Physics Group Using Bespoke Matlab Software for the Collection and Processing of Dynalog Files from the Varian Millennium 120 MLC system following delivery of Intensity Modulated Fields. Presenter: Carl Horsfield Radiation Physics, Queen s Centre for Oncology and Haematology, Castle Hill Hospital. 1

Summary: Introduction to the MLC system Description of the log files Aims of the use of the Dynalog system Method: Description of Graphical User Interface (GUI) Data used Results Questions 2

IMRT: 1. 120 Tungsten Leaves used to shape radiation fluence. 2. Fluence combines with other beams to produce required dose distribution 3

IMRT current testing: Current QA is performed Pre-treatment verification of fields Checks of leaf motion Transfer of data General deliverability of plan Second check software Frequent imaging What is missed? Verification of correct delivery when the plan is delivered to the patient on a daily basis. 4

What are Dynalogs: These are produced by the MLC controller on Varian Linacs for all IMRT deliveries. They log data every 50ms on various parameters They indicate performance of the MLC which gives information on the performance of the Linac 5

File Format: Current Dose Fraction Beam state Gantry angle Collimator angle Jaw positions Carriage positions Leaf plan position Leaf actual position Described in Varian s Dynalog File Viewer: Reference Guide 6

Dynalogs: Commercial products currently exist to process Dynalog files. Varian: Dynalog File Viewer Limited functionality but suitable for customer acceptance Doselab: FractionCHECK Not free but does look very good These files can also be interrogated cheaply using MATLAB. 7

Aims of this work: To develop a lost cost Matlab program to analyse MLC performance during IMRT delivery. Tested by Comparing QA results to Dynalog results. 8

Bespoke Matlab GUI for Dynalogs: Individual file pair GUI Processes Leaf Speed Leaf RMS error Time for beam holds Histogram of errors Gap size Fluences 9

Bespoke Matlab GUI for Dynalogs: Multi file pair GUI Exports reports to excel 10

Data Collection: MLC movements are logged and stored on the treatment console Each linacs data is moved to a single location- RT server Dynalogs are retrievable from the treatment console. Either manually or automatically. Delete after transfer 11

Dynalogs: Files can then be analysed from one location On a PC with MCR (Matlab Compiler Runtime) environment installed. Separated according to Linac Organised according to patient identifying number Can be reviewed at chosen intervals 12

Excel spreadsheet for handling data: 13

Excel spreadsheet for handling data: Report generated automatically Summarises all machines checked Highlights Linacs that data was not processed for Failing leaf identified in report 14

Leaf error displayed graphically in the single file viewer module of the GUI. The example shows bank B leaf 10 failing which was identifiable from its maximum error. 15

Conclusions: This work shows that a low cost home made approach to the collection and processing of dynalog files can be fruitful. The free information obtainable from the collection of dynalog files can provide good fraction by fraction assessment of MLC performance via an automated process with no extra machine time required for QA. 16

Future Work: Firstly, run a monthly report on the performance of the MLC. Secondly, compare results from Dynamic breast fields to our currently used step and shoot IMRT method. 17

Acknowledgements: Thank you to Dr Michael Hughes, (Department of Medical Physics & Clinical Engineering, Oxford University Hospitals NHS Trust) for providing parts of the code. Code available at > http://mike-hughes.org/medphys/dynalog.html Hull s Oncology Information Systems team for setting up the transfer of these files and to Jenny Marsden & Prof Andy Beavis for their supervision 18

The End: 19