Install the Software and Hardware

Similar documents
LabVIEW Tutorials. T.1 Temperature Measurement and Cold Junction Compensation (CJC) LUMS School of Science and Engineering

Introduction to Labview and Temperature Measurement

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

1. Learn about LabView software and its different components

Determination of Drag Coefficient

Create a worksheet that collects, displays and saves temperature data

Programming for the LabVIEW Real-Time Module Using LabWindows/CVI

Data Acquisition Laboratory

Getting Results with CompactRIO and LabVIEW

Advanced NI-DAQmx Programming Techniques with LabVIEW

Strain and Force Measurement

Personal Daqs USB Data Acquisition Modules Models /55 & /56

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

NI-DAQmx Basic Course NITS John Shannon

SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

Data Acquisition in LabVIEW

LabVIEW Real-Time Module for Mac OS X User Manual Addendum

Developing Networked Data Acquisition Systems with NI-DAQ

Hands-on Lab 2: LabVIEW NI-DAQ Basics 2

User Manual. Printed: 11/6/2013 Filename: NATUM1 - National Instruments I/O Device for V+ User Manual, V1.1 Copyright 2003, SimPhonics Incorporated

A Review of PC-Based Data Logging and Recording

DT9828. USB Powered Thermocouple Measurement Module. Key Features: Analog Input Channels

NI Contents. Hardware Overview INSTALLATION GUIDE. NI 8221 Features

VXI-8340 SERIES INSTALLATION

Temperature Measurement Instruments Ultra-Accurate... by Design

ChartView Out-of-the-Box Setup, Acquisition, & Real-Time Display Software

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

BE/EE189 Design and Construction of Biodevices Lecture 5. BE/EE189 Design and Construction of Biodevices - Caltech

Contents. Software CALIBRATION PROCEDURE NI TC-4353

Software-Defined Test Fundamentals. Understanding the Architecture of Modular, High-Performance Test Systems

A Step Into the Future of Data Measurement. Focus on Tests and Measurements. Let idaq Do the Rest.

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

Foundation Fieldbus Hardware and NI-FBUS Software for Windows 2000/XP

KIT NI-VISA FOR WINDOWS 95/NT: WIN95, GWIN95, WINNT, AND GWINNT FRAMEWORKS

LabVIEW Basics I: Introduction Course

Multifunction DAQ Accessory and Cable Selection Guides

Wiring guide for dual-output vibration and temperature sensors

Ultra-Accurate Temperature Measurement Instruments

Data Acquisition Fundamentals

Step-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform

PC-based data acquisition I

High-Precision Data Acquisition

LabWindows /CVI Using the Latest ANSI C Tools for High-Performance Automated Test

LabWindows /CVI Release Notes Version 8.0.1

Moving from BASIC to C with LabWindows /CVI

PXI The PXI-8220 is a two-slot PC Card (PCMCIA) carrier for the PXI/CompactPCI bus.

Computerized Measurement systems

Getting Started with the NI 783x R

PHY 351/651 LABORATORY 1 Introduction to LabVIEW

LABVIEW REAL-TIME. Contents. About LabVIEW Real-Time (RT) RELEASE NOTES. Version 6.1

LabVIEW Real-Time Module Release and Upgrade Notes

Answers to Frequently Asked Questions about NI-DAQmx and Traditional NI-DAQ (Legacy)

NI-DAQ mx for USB Devices

Acquiring Data from Sensors and Instruments Using MATLAB

Data Acquisition. Software and Hardware. Demonstration Guide. For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke

High-Speed M Series Multifunction DAQ 16-Bit, up to 1.25 MS/s, up to 80 Analog Inputs

Building a Next Generation Data Logging System

Developing Measurement and Analysis System using MATLAB

Measurement Studio Using.NET in Your Test and Measurement Applications

OpenStax-CNX module: m Thermometer VI * National Instruments

High-Accuracy M Series Multifunction DAQ 18-Bit, up to 625 ks/s, up to 32 Analog Inputs

Engineering Project-I. Module 1: Familiarization of LabVIEW and the Vernier Toolkit

Data Acquisition Software and Hardware. Demonstration Guide. For: NetDAQ Logger, Hydra Logger, and Trend Link for Fluke V3.1

Getting Started with R Series Intelligent DAQ

CALIBRATION PROCEDURE CAL Contents. Software

Where to Start with NI ELVIS

NI-VISA for Windows 3.x WIN and GWIN Frameworks. The VXIplug&play software kit contains the following software and documentation components.

NI-Industrial Communications for EtherCAT

NI Technical Symposium ni.com

48-Bit Isolated Digital I/O

The Measurement Revolution

Detailed Specifications 6 1/2 Digits High-Performance DMM

SCXI -1313A Terminal Block

To access NI 5114 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14

LabVIEW Real-Time Module Release Notes

PXI The PXI-8210 is a Fast Ethernet/Ultra Wide SCSI interface for the PXI/CompactPCI bus.

Ultra-Accurate Measurement for Temperature and Voltage

VXIPC 800/700 SERIES FOR WINDOWS 95/NT

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

USER MANUAL for USB 2.0 Card Bus

Where to Start with NI ELVIS

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

Design and Research of Virtual Instrument Development Board

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

GETTING STARTED GUIDE

NI High-Speed Digitizers

Hardware: Acquiring Data and Communicating with Instruments

The hardware implementation of PXI/PXIe consists of a chassis, controller or computer interface, and peripheral cards.

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

Temperature Measurements using the KPCI-3108 with the EXP-1800

VMISFT-9450 I/O Connectivity IOWorks Board Drivers

Introduction to Automating Standalone Instruments

Additional products and features

LabWindows /CVI Release Notes Version 9.0

Data Acquisition Software and Hardware Demonstration Guide

LabVIEW FPGA Module Release and Upgrade Notes

NI 6703/6704 Calibration Procedure for NI-DAQ mx

NI High-Speed Digitizers

For NI PXI and NI SCXI Switch Modules

Transcription:

WHERE TO START WITH YOUR NI 4350/4351 This document explains how to begin using your National Instruments 4350/4351 high-precision temperature and voltage meters. The NI 4350/4351 (NI 435x) products include instruments for ISA, PCMCIA, USB, PCI, and PXI/CompactPCI buses. Install the Software and Hardware Perform the following procedure to install your NI 435x: 1. Run setup.exe from the NI4350/4351 CD. 2. Click Install NI 4350/4351 Software on the installation screen. 3. Follow the instructions on the screen and then click OK to restart your computer. 4. Turn off your computer and install your NI 435x instrument as shown on the following pages. Note The NI 4350 (PCMCIA and USB) are Plug and Play instruments, and can be plugged in at any time after the drivers are installed, even without turning off your computer. ComponentWorks, CVI, LabVIEW, PXI and VirtualBench are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. 321562C-01 Copyright 1997, 1999 National Instruments Corp. All rights reserved. January 1999

NI 4350 (ISA) NI 4350 (ISA) Personal Computer ISA Slot NI 4350 (PCMCIA) Portable Computer PCMCIA Socket NI 4350 (PCMCIA) For more information on hardware installation, refer to the NI 4350/4351 User Manual. Where to Start with Your NI 4350/4351 2 National Instruments Corporation

ON STANDBY NI 4350 (USB) NI 4350 (USB) USB Connector (Downstream) USB Connector to Personal Computer (Upstream) NI 4351 (PXI) PXI Chassis 1 2 3 4 5 6 7 8 NI 4351 (PXI) Ejector Handle in Down Position For more information on hardware installation, refer to the NI 4350/4351 User Manual. National Instruments Corporation 3 Where to Start with Your NI 4350/4351

NI 4351 (PCI) NI 4351 (PCI) Personal Computer PCI Slot For more information on hardware installation, refer to the NI 4350/4351 User Manual. Configure and Test the NI 435x Use the following procedure to configure and test your NI 435x: 1. Launch Measurement & Automation Explorer on your desktop. 2. Double-click on the Devices and Interfaces icon. 3. Right-click on your NI 435x instrument and select Properties. In the System window, note the Device Number that has been assigned. You will need to use this device number when you program your instrument. 4. From the System window, click the Test Resources button to test the NI 435x resources. A dialog box appears and indicates whether the resource test has passed. 5. In the Accessory window, select an accessory that is attached to your NI 435x instrument. 6. From the System window, click the Run Test Panels... button to run functional test panels. Connect your signal to an input channel on your attached accessory and select your Channel, Input Limits, Sensor Type settings. If your sensor type is a thermocouple, select the correct option in CJC Info. Your NI 435x instrument immediately starts to acquire data. 7. When you finish testing, click Close and then OK in the Configuring Devices window. Where to Start with Your NI 4350/4351 4 National Instruments Corporation

When you finish configuring and testing your NI 435x, you can launch VirtualBench-Logger from Start»Programs»National Instruments VirtualBench. Use VirtualBench to control your NI 435x without any programming. NI 435x Software Selection Chart Figure 1 shows the choices you have for programming your NI 435x. See the Software Options for NI 435x Explained section for more information on each software package. If you do not have LabVIEW, LabWindows/CVI, or ComponentWorks installed on your computer, and would like to evaluate the software package, the evaluation versions are provided on the NI 4350/4351 CD. National Instruments Corporation 5 Where to Start with Your NI 4350/4351

Launch Measurement & Automation Explorer. Right-click on your NI 435x device to configure the accessory. Then run test panels to verify that your NI 435x is installed correctly. Do you want to use standalone ready-to-run application software that does not require any programming? No, I want to write and use my program. Yes Which programming environment are you going to use? Use VirtualBench-Logger LabVIEW Use the NI435X instrument driver. Refer to the examples in vxipnp\[operating system]\ni435x\ examples\labview. Refer to NI435X LabVIEW Help in Start»Programs» National Instruments 435x (ni435x_g.hlp) for help on the instrument driver functions. LabWindows/CVI Use the NI435X instrument driver. Refer to the examples in vxipnp\[operating system]\ni435x\ examples\cvi. Refer to NI435X C, Visual Basic Help in Start» Programs»National Instruments 435x (ni435x_text.hlp) for help on the instrument driver functions. Component Works/Visual Basic Use the NI435X instrument driver. Refer to the examples in vxipnp\[operating system]\ni435x\ examples\cw. Refer to the NI435X C, Visual Basic Help in Start» Programs»National Instruments 435x (ni435x_text.hlp) for help on the instrument driver functions. or or or Use virtual channels with the Channel Wizard. Configure your virtual channels in the Data Neighborhood in the Measurement & Automation Explorer. Refer to the examples on the NI 4350/4351 software CD in ni-daq\examples\ labview. Use virtual channels with the Channel Wizard. Configure your virtual channels in the Data Neighborhood in the Measurement & Automation Explorer. Refer to the Easy I/O for DAQ Library functions, and the examples on the NI 4350/4351 software CD in ni-daq\examples\cvi. Use virtual channels with the Channel Wizard. Configure your virtual channels in the Data Neighborhood in the Measurement & Automation Explorer. Refer to the examples on the NI 4350/4351 software CD in ni-daq\examples\cw. Figure 1. Software Choices for Your NI 435x Where to Start with Your NI 4350/4351 6 National Instruments Corporation

Software Options for NI 435x Explained What Is VirtualBench? What Is VirtualBench-Logger? What Is LabVIEW? This section explains the software choices for your NI 435x. Traditional instruments have three basic components acquisition and control, data analysis, and data presentation. The trends in desktop and notebook PCs have delivered computers that surpass the display and processing capabilities of most instruments. The technology of today s computer-based instruments is comparable to much of the data acquisition and control capabilities of traditional instruments. You use VirtualBench just as you use standalone instruments, but you benefit from the processing, display, and storage capabilities of PCs. VirtualBench instruments load and save waveform data to disk in a form that can be used by popular spreadsheet programs and word processors. A report-generation capability complements the raw data storage by adding timestamps, measurements, user name, and comments. You can print the waveforms and the settings of VirtualBench to a printer connected to the PC. Because the user manual and help are all online, you can easily refer to them at any time. When used with the NI 435x, VirtualBench-Logger acquires up to 16 channels of data from one instrument while displaying all of the channels. With menus, you configure the parameters of each channel including channel name, conversion factors (Mx+B), units, display range, and display scale. Built-in conversion factors for B, E, J, K, N, R, S, and T-type thermocouples and resistance temperature detectors (RTDs) simplify temperature measurement. Thermocouple measurements use polynomial equations for linearization and automatically perform cold-junction compensation. Automatic-current scaling is available for current measurements. Software-selectable 50 and 60 Hz noise rejection helps acquire accurate signals in noisy environments and complements the analog noise filters built on the NI 435x hardware. Dual y-axes make it possible to monitor signals of different types on the same display. LabVIEW is a graphical programming language for building instrumentation systems. With LabVIEW, you quickly create front panel user interfaces, giving you interactive control of your software system. To specify the functionality, you intuitively assemble block diagrams a National Instruments Corporation 7 Where to Start with Your NI 4350/4351

What Is LabWindows/CVI? What Is ComponentWorks? natural design notation for engineers and scientists. LabVIEW has all of the same development tools and language capabilities of a standard language such as C looping and case structures, configuration management tools, and compiled performance. LabWindows/CVI is an interactive, ANSI C programming environment designed for automated test applications. LabWindows/CVI has an interactive drag-and-drop editor for building your user interface and a complete ANSI C development environment for building your test program logic. The LabWindows/CVI environment has a wide collection of automatic code-generation tools and utilities that accelerate your development process, without sacrificing any of the power and flexibility of a language such as C. In addition, the LabWindows/CVI run-time libraries are compatible with standard C/C++ compilers, including Visual C++ and Borland C++ under Windows. Use the Easy I/O for DAQ Library or the NI435X instrument driver with your NI 435x. ComponentWorks is a collection of 32-bit ActiveX controls designed for scientists building virtual instrumentation systems. With ComponentWorks, you can combine the power and flexibility of standard development tools, such as Microsoft Visual Basic or Visual C++, with the instrumentation expertise of National Instruments. Based on ActiveX technology, ComponentWorks controls are easy to configure through simple property sheets and easy to control from your programs using high-level properties and methods. ComponentWorks features instrumentation-based graphical user interface (GUI) tools, including graphs, meters, gauges, knobs, dials, and switches. Use the NI435X instrument driver with ComponentWorks. What Is the NI435X Instrument Driver? An instrument driver packages instrument capabilities as a set of standard functions. Each function corresponds to a programmatic operation such as configuring, reading from, writing to, and starting and stopping the measurements. An instrument driver reduces your program development time and simplifies instrument control by eliminating the need to learn complex programming protocol for each instrument. The NI435X instrument driver provides flexibility and programmability in a standard instrument driver format. The instrument driver application Where to Start with Your NI 4350/4351 8 National Instruments Corporation

programming interface (API) was designed after a traditional, full-featured data-logger instrument driver. The NI435X instrument driver is VXIPlug&Play compliant and also contains the source code, so that you can examine and modify it, if you wish. The NI435X instrument driver works with LabVIEW, LabWindows/CVI, or conventional programming languages such as C, C++, and Visual Basic. For more details on what an instrument driver is, visit the www.vxipnp.org web site. What Is the Channel Wizard? What Is a Virtual Channel? In the past, data acquisition system developers spent a large amount of time defining the signal types, connections, transducer equations, and unit conversions before beginning development of the actual system. For example, if you are using thermocouples, you must perform additional cold-junction compensation (CJC) calculations to convert raw voltage values into actual temperature readings, and then apply scaling factors that depend on the type of thermocouple used. From there, you may need to use additional code to convert the temperature into proper units, such as degrees Celsius, Fahrenheit, or Kelvin. With the Measurement & Automation Explorer channel wizard, you simply fill in the blanks to define an input signal by specifying its name and description, the type of transducer being used, any scaling factors or equations required, CJC settings, and unit conversion factors. The channel name, also known as a virtual channel, is then referenced throughout the application with all of the conversion processes performed transparently. At this time, you cannot use the channel wizard with the NI435X instrument driver. Refer to the examples recommended for use with the channel wizard in the chart shown Figure 1. National Instruments Corporation 9 Where to Start with Your NI 4350/4351