Task Controller Setup Manual

Similar documents
AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.*

AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.6.*

Operating Instructions

Activations. Set date and time prior to entering Activation codes to ensure the Activations will be acknowledged. Data Transfer

Generation 4 Displays Software Update 18-1 Release Notes

Release Notes. Important Notes:

ISOBUS Working Set. One or more ISOBUS modules that control an implement s functionality. Main module is called the Working Set Master (WSM).

Operating Instructions

IC18 NH3 JOB COMPUTER

Generation 4 CommandCenter

SOFTWARE OPERATING GUIDE

INTEGRA Version Firmware Release

Generation 4 CommandCenter

VARIABLE RATE APPLICATION Sales conference st charles

Generation 4 Displays Software Update Release Notes


Harvest Setup for CNH controllers

Generation 4 Displays Software Update Release Notes

User Manual. Gateway 6.2: Map Math

ISOBUS Quick Reference Installation Guide. Liquid Fertilizer Anhydrous Ammonia Sprayer Spreader Slurry

Insight Cable Connections to Mid-Tech Controllers with Datalink

Quick Reference Guide

Display Quick Reference Guide

CR7 Operation Manual. P/N Rev. A 10/17 E29486

Generation 4 Displays Software Update 17-2 Release Notes

CANBUS PRODUCT CONTROL

Online - Display and CommandARM TM Simulator. Help Guide

LOW-COST, UNIVERSAL WIRELESS DATA TRANSPORT

ACCESSORY APPLICATIONS

AEROS FIELD COMPUTER RELEASE NOTES RELEASE NOTES

For use with Aeros 9040 v4.30 DynaJet Flex IC18 Sprayer v1.10

Quick Reference Guide

MyJohnDeere.com. How to Guide. For questions, please contact your Integrated Solutions Specialist

OPERATOR S GUIDE. Document revision: 1.0 Last revised: January 29, 2018

MCS-TOUCHSCREEN Auto Disk Clean up

Original Greenstar and GS 2 Raven Setup

EDGE User Manual Firmware Version 4.5 Ag Leader PN Rev. F

Available Map Views & Dash View Screen

SOFTWARE OPERATING GUIDE

Insight Cable Connections to Rawson, New Leader Mark III & Mark IV, Flexi-Coil Controllers

InSight User Manual Firmware Version 8.0 Ag Leader PN Rev. H

IF YOU DO NOT UPDATE BOTH THE DISPLAY AND DESKTOP SOFTWARE VERSIONS, DATA LOSS COULD OCCUR WHEN UNLOADING DATA.

Online - Display and CommandARM TM Simulator. Help Guide

CONTROLLER HC 8600/9600

SINCE 1966 INTELLIAG AI-120 ISO VIRTUAL TERMINAL. Operator s Manual

AGCO (Massey, Challenger & Gleaner) Monitors

Table of Contents Data Management...1

AGCO (Massey, Challenger & Gleaner) Monitors

MyJohnDeere.com. How to Guide. For questions, please contact your Precision Ag Specialist. Brookings/Garretson Scott Krogstad Cell:

/9/14 Fixes for display crashing Fixes for Sidekick Pro initial setup

Using AgLeader SMS Software for yield data analysis; Step-by-step guide

Table of Contents. CenterLine 250/IC18 Quick Start Guide Chapter 1 - Product Overview... 5 Key Functions Startup Sequence...

The Preferences link will display the following user options. These may be changed by the user at any time.

Safety Notices Tramline Setup Setup Input Type Input State (Hi/Lo) Assigning Sensors Auxiliary Power...

Innovations at Agritechnica 2015 Reichhardt focuses on three core areas and even more customer benefits

Installation and Operation Manual: UHarvest Data Management System. P/N Rev. C 07/15

Commercial Fertilizer

Display and CommandARM TM Simulator Help Guide

Trust Truesight 2 - True row guidance for high accuracy row-crop autosteer control

OPERATOR S MANUAL. Safety Notices... 1

CLICK THE ARROW TO GET STARTED

UHarvest Slingshot Reports Introduction

ISOBUS for Trailed Sprayers Implementation and Experience

How to: Variable Rate Application CFX-750 vs. 4.05

John Deere Operation Center Guide

Transporting Data Files from the Office to the Field Manual Mode

Quick Reference Card. Setting up the FmX Integrated Display with the Autopilot System

Quick Reference Card

Farm Sprayer GPS Pro & Pro Software. Operation Manual

TopCon X5 Operator's Manual

INSTALLATION MANUAL. Agra-GPS Versatile-JD Bridge (row crop tractor)

AMS Compatibility Tool: Frequently Asked Questions. Table of Contents

Important Notes: Release Notes

Agri-Spread Apollo II

PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a planter March 2002

Salt Traxx Operation Operation without a Flash Drive Operation with a Flash Drive

Operation Manual ISOBUS Ammonia Liquid Fertilizer Controller

we can help you get there Wherever your Precision Agriculture is taking you... Service & Products for Precision Agriculture

NOTE: This update is not approved for Case IH users. This update is only valid if using ROS 2.x and higher. If updating from ROS

Automated Crop Reporting Manual. Collecting and transferring data to JohnDeereAgent

Utilize CR7 to its full potential with these enhancements:

ISOBUS COMPATIBILITIES PRECISION FARMING DATA MANAGEMENT COMFORT INNOVATIVE SOLUTIONS FOR CONNECTED FARMERS. be strong, be.

PRODUCT MARKETING BULLETIN

ISO Mobile Data Element Dictionary DDE Request Form

Update Manual. ME-Terminals. Version: V Read and follow these operating instructions.

Troubleshooting Guide DCM-300 Modem with Correction Services

FOR 240 Lab 8 Assignment Using GPS to Collect Spatial Data of Forest Management Introduction to Computing in Natural Resources

John Deere FarmSight. The future of farming is in your sight.

Home Page Top Bar Preferences Language Unit of Measurement Note: Map Refresh Interval Idle Session Timeout Note: Save Preferences Help

SMS Basic and Advanced Version x Release Notes. Contents:

VOYAGER 570G U s E R M A N U A L U s E R M A N U A L

Generation 4 Displays

RELEASE NOTES. FmX Integrated Display. Introduction. Feature change overview. Feature changes. Upgrade procedure

We will do our best to ensure that you are happy with your current system and that it is upgraded in the future to better meet your needs.

Installation and Operation Guide

UPGRADE INSTRUCTIONS

Farm Works Software Solutions: Multi Swath Line Management

Q4 Updates Include: PRODUCT UPDATE. Login using your OneView username and password.

Instructions for Downloading the Latest Software Enhancements for the GreenStar System

Installation. Installation 1

Transcription:

Task Controller Setup Manual P002463 Last Update: 1/17/2017 Read and follow this operating instructions. Keep this operating instructions for future reference. 1

2

Table of Contents 1 Task Controller Setup for AgLeader Integra Display 3 1.1 Integra Operating Configuration Setup 3 1.2 Integra Troubleshooting 6 2. Task Controller Setup for John Deere GS3 Display 7 2.1 John Deere GS3 Operating Configuration Setup 7 2.2 John Deere GS3 Troubleshooting 11 3. Task Controller Setup for Mueller Touch 800/1200 12 4. Task Controller Setup for Pro700 & IntelliView IV (v. 26-29) 15 4.1 Pro700 & IntelliView IV Operating Configuration Setup 15 4.2 Pro700 & IntelliView IV Troubleshooting 18 5. Task Controller Setup for Pro700 & IntelliView IV (v. 30) 20 5.1 Pro700 & IntelliView IV Operating Configuration Setup 20 5.2 Pro700 & IntelliView IV Troubleshooting 24 3

1 Task Controller Setup Integra Operating Configuration Setup 1 Task Controller Setup for AgLeader Integra Display 1.1 Integra Operating Configuration Setup Description 1 Confirm the display has multi-product unlocked. Select Operating Configuration Type. Select a vehicle. Display 2 Create a new implement. 3 Enter the hitch to Implement Axel Distance (use same value in spreader ECU). 4 Create or use an existing application channel. This needs to be created using the Granular Application. 5 Select Strip Till. 6 Setup a New Application Rate Controller. 7 Set the Controller Name for the spreader application. 4

Task Controller Setup Integra Operating Configuration 1 8 Select Device ISOBUS 9 Select Montag as the Make 10 - Select Sprayer Job Computer as the Model 11 Verify the Supports Rate Control is checked 12 Set the number of application channels to match the spreader ECU. 13 Set the name of the hoppers available Set the capacity of the hopper to match setup in Spreader ECU Select units. Spreader ECU uses Cubic Feet 14 Set the number of boom sections to match the spreader ECU section control. 5

1 Task Controller Setup Integra Troubleshooting 15 Set the Product Type to Fertilizer. 16 Select the type of fertilizer product. The spreader ECU will be applying. 17 Set the product Units to pounds. 18 Select the Operating Configuration for the spreader application. 19 Select the product intended for the spreader application. 1.2 Integra Troubleshooting If the Operating Configuration has a configuration mismatch, check the following: Verify the number of sections are setup to match the ISOBUS ECU. Verify the application channels are setup to match the ISOBUS ECU. Verify the product application Units are setup to match what the ISOBUS ECU is sending (spreader ECU sends the rate over in lbs/ac). Verify the correct Operating Configuration is selected for the implement that is hooked up. 6

Task Controller Setup GS3 Operating Confirguration Setup 2 2 Task Controller Setup for John Deere GS3 Display 2.1 John Deere GS3 Operating Configuration Setup Description 1 When the implement is connected, this screen will appear indicating that the ECU has been recognized. The ECU should be set-up in the Virtual Terminal and the system should be restarted. Display 2 To begin the setup, select the GS3 tab and check the Section Control box and Documentation. Press accept. 7

2 Task Controller Setup GS3 Operating Confirguration Setup 3 Fill in all of the drop boxes on page 1/6 to select your task. 4 Select the tractor settings on page 2/6. 5 The implement should pre-populate page 3/6 with all information from the ECU. 8

Task Controller Setup GS3 Operating Confirguration Setup 2 6 Check the Section Control Master and the corresponding Operation Boxes on page 4/6. 7 Select the Operation and Product Application Type on 5/6 for record keeping. The rate from the ECU should be grayed out in the target rate box. 8 Select Rx and highlight a prescription from the drop list. Press accept. 9

2 Task Controller Setup GS3 Operating Confirguration Setup 9 Screen 6/6 is simply for mapping and selecting the boundary. 10 Press Accept and begin application. 10

2.2 John Deere GS3 Troubleshooting Task Controller Setup GS3 Trouchshooting 2 Clearing the Object Pool If switching implement configurations (dimensions, sections, application layers) or the same ECU type on different machines, it is necessary to clear the internal memory in the display. To do this, perform the following steps. This will not remove any settings from the implement and no values, calibrations or user preferences will be lost. After this is completed cycle power on the display. Make sure all changes are done before turning off the display. Documentation Boxes Grayed Out If documentation boxes are grayed out, do the following: 1. Insert USB stick and export the data. 2. Clear the object pool following the steps above. 3. Verify that the implement is not in work. (make sure the master switch is off) 4. Create new Client, Farm, Field, Task in the GS3 page 1/6. 5. Create a new product and verify that the units (lbs/ac, gal/ac, tons/ ac.) in the GS3 page 5/6 match your controlling units. 6. If using prescriptions, verify that they are in the proper GS3 format. Insert USB and import the information. Go through the entire GS3 setup to select your prescription. 11

3 Task Controller Setup Mueller Touch Operating Confirguration Setup Task Controller: Display > Diagnostics > Multiple Displays > Change Settings verify Greenstar, Task Controller, and Auto implement detection, ISOBUS Certification and Implement Bus are all selected. Verify Task Controller VT number set to 1. Multiple Displays screen will show current status of all settings above Display software information can be found in Display > Diagnostics > About. Section Control: Verify section control unlock GS3 > GS3 > Activation Section Control. Verify unlock is not temporary and is listed as active. Verify section control is selected in GS3 setup. Verify Implement Setup is correct including sections and widths. Verify Implement model is ME USA Seeder. Verify Section Control is checked for Master and for each operation. Verify GPS is working properly and the display has a DGPS signal. 12

Task Controller Setup Mueller Touch Operating Confirguration Setup 3 3 Task Controller Setup for the Mueller Touch 800 & Touch 1200 Description 1 In the ISOBUS-TC screen press Settings. Press the USB icon to create the Taskdata folder. Display 2 Press the Plus icon to create a new task. Customer, Farm, Field, and task name may then be created. A task already created may be selected from the list in this screen. 13

3 Task Controller Setup Mueller Touch Operating Confirguration Setup 3 Press the back arrow and select yes to save the new task. 4 Press the Play icon to begin the new task. Select the Target Rates. 5 Press the Plus icon to assign Rates and Layers. 14

Task Controller Setup CNH Operating Confirguration Setup 4 6 The available control layers will appear and can be selected along with units, volume, and associated products. 7 Verify the layers and rates. Press the back Arrow and a pop-up will appear. Select Yes to save. 15

4 Task Controller Setup CNH Operating Confirguration Setup 4 Task Controller Setup for the Case IH Pro700 & NH IntelliView IV (v.26-28) 4.1 Pro700 & IntelliView IV Operating Configuration Setup Description 1 In the performance screens, select the Task Controller Tab and fill out or select the grower, farm, field, task, and operator. Do not press Start at this time. Display 2 Select the Primary Implement. 16

Task Controller Setup CNH Operating Confirguration Setup 4 3 Identify the TC Map layers and any associated prescriptions. Once all these have been set up go back to the TC Task tab and press Start. 4 Now that the Task has been started, TaskController will take over implement Settings, work condition, prescriptions, and the Grower, farm, field profile. 5 Implement setup screen. 17

4 Task Controller Setup CNH Troubleshooting 6 Prescription setup screen. 7 Work Condition screen. 18

Task Controller Setup CNH Operating Configuration Setup 5 4.2 Pro700 & IntelliView IV Troubleshooting (v. 26-28) If switching implement configurations (dimensions, sections, application layers) or the same ECU type on different machines, it is necessary to clear the internal memory in the display. To do this, perform the following steps Deleting the object pool: 1. In the Main menu, select Diagnostics 2. Select the VT tab 3. Select the NVM tab 4. Here, multiple object pools are saved and stored. You can select which one to delete by pressing Next Folder 5. Select delete folder at the top right to delete the selected object pool or the delete icon in the middle right to delete all. This will not remove any settings from the implement and no values, calibrations or user preferences will be lost. If the display does not map, verify the TC steps above are completed and that all the boxes that should be grayed out are. Verify map legends, prescriptions style, data style, data type, and zoom are set correctly Make sure that prescriptions and management files are in ISOXML format (a single Taskdata folder containing at least a Taskdata xml file) on the USB stick. A USB must be in the display for TC to function. You may also have a.cn1 folder in addition to the Taskdata folder. A blank USB may be used and the display will auto create the Taskdata folder. It is recommended to include Product Names associated with Tasks and Prescriptions as there are no parameters in the Pro700 to identify this. Overlap and Boundary control will each trigger the section control icon in the VT. NOTE: The OEM software versions displayed in this document may not be the most current. Please confirm that you have the latest display and ECU firmware. 19

5 Task Controller Setup CNH Operating Configuration Setup 5 Task Controller Setup for the Case IH Pro700 & NH IntelliView IV (v.30) 5.1 Pro700 & IntelliView IV Operating Configuration Setup Description 1 The first step is to verify that the display has the necessary components for Task Controller to function. Go to Diagnostics > Version. Confirm that VT and Task Controller are listed. If VT and/or Task Controller are not listed, please contact your dealer. Display 2 From the main screen, navigate to Toolbox > VT > Setup. On the Setup tab, confirm the following settings: VT Enabled = Yes VT Compatibilty = Version 3 VT Number = 1 Send ISO Speed? = GPS 20

Task Controller Setup CNH Operating Configuration Setup 5 3 Toolbox > Activate: Ensure that the Task Controller is activated. A trial activation is available to test functionality before purchase. If Task Controller is not active, please contact your dealer. After a successful activation, the display must be rebooted before Task Controller configuration can be performed. 4 Toolbox > TC: Set the Task Controller to Installed (requires reboot). Ensure that the TC Operation Mode is Advanced (requires reboot). Select the Tractor Type and Front/Rear Hitch Offsets. Hitch offsets are measured from the hitch point to the centerline of the fixed axle. 5 Performance > Profile: Note that some data management items are grayed out. When using the Task Controller, all data management is initiated in the Task Controller. The Pro le screen is not used. 21

5 Task Controller Setup CNH Operating Configuration Setup 6 ISOBUS > TC Main: Create or select the TC Grower, TC Farm, TC Field, and TC Task to be used. TC management items may be exported from a compatible desktop software program in ISOXML, or created in the display. Do not press the Start button until all Task Controller configuration is complete and you are ready to begin operation. 7 ISOBUS > TC Main: Use the buttons on the right side of the screen to configure and monitor the Task Controller. Confirm the TC Imple = ME USA Seeder. Press the Done button to return to the TC Main screen from any configuration/ monitoring screen. 8 TC Main > TC Map: Verify that the correct control points are assigned to the map. Select prescriptions for each control point if desired. Confirm for the following: TC Map Layer 1 = Boom 1 TC Map Layer 2 = Boom 2 (only on 2 hopper machine) To load a prescription, press the TC Prescription field and select the prescription file. 22

Task Controller Setup CNH Operating Configuration Setup 5 9 Notes About Prescriptions: Prescription files must be exported from an FMIS as an ISOBUS compatible file. For multi-bin machines, prescriptions must be saved as Type 2. On the USB stick, all TC info will be saved in the Taskdata folder. 10 TC Main > TC Crop: Create or select the TC Crop to be used. Click the Add New Variety button to create a new variety/ hybrid. Select the desired Tracking Level: Implement: tracks one hybrid across the entire implement. Boom: tracks one hybrid per driven section as de ned by the implement ECU. Section: tracks one hybrid per section, as defined by the implement ECU for section control. 11 TC Main > TC Totals: Displays raw totals values received from the implement ECU. Each value may be a lifetime total or a TC Task total, whichever is reported by the implement ECU. Units of measure are provided by the ECU. 23

5 Task Controller Setup CNH Troubleshooting 12 TC Main > TC Sum: Provides a complete summary of the current active Task Controller configuration. 13 When the implement and Task Controller have been fully configured and you are ready to begin field work, press the Start button in ISOBUS > TC Main or on a Run screen that contains a Task Controller control window. 5.2 Pro700 & IntelliView IV Troubleshooting (v. 30) If switching implement configurations (dimensions, sections, application layers) or the same ECU type on different machines, it is necessary to clear the internal memory in the display. To do this, perform the following steps Deleting the Object Pool: 1. In the Main menu, select Diagnostics. 2. Select the VT tab. 3. Select the NVM tab. 4. Here, multiple object pools are saved and stored. You can select which one to delete by pressing Next Folder. 5. Select delete folder at the top right to delete the selected object pool or the delete icon in the middle right to delete all. This will not remove any settings from the implement and no values, calibrations or user preferences will be lost. This will not delete any settings in the VT. It will require a longer time for the VT to load the next time the display is powered on. 24

Section Control Checklist: Verify in Toolbox >TC. Verify a USB stick is in the display. Verify in ISOBUS > TC Main that a task is started and ME USA Seeder is the implement. Verify GPS status is set to DGPS. Verify Toolbox > Overlap options for either boundary or overlap control are selected. Add Overlap Control and Boundary Control to the Run Screen and verify they are selected. Verify boundaries are on the USB stick and were exported to the.cn1 file. Verify the machine goes into work (green arrow in upper left of display). Verify the machine is mapping. Prescriptions Checklist: Verify in Toolbox >TC. Verify a USB stick is in the display. Verify in ISOBUS > TC Main that a task is started and ME USA Seeder is the implement. Verify GPS status is set to DGPS. Verify Prescriptions are on the USB stick and were exported to the.xml file format. If the machine has multiple bins, prescriptions must be Type 2. Verify the machine goes into work (green arrow in upper left of display). Verify in the VT screen that Prescription Target Rate is selected. Verify Overlap Control is not preventing application. As-Applied and Products: As-Applied maps are available in both.xml and.cn1 formats. Products must be set up in ISOBUS > TC Main > TC Products. - Here products must be added or selected. - Tracking Level should be set to Boom. - Products should be selected for each Boom. Task Controller Setup CNH Troubleshooting 5 - Product setup in the VT will be part of the the layer name. 25

5 Task Controller Setup CNH Troubleshooting Machine will not apply: Verify speed in VT (check speed selection in VT and setup in display). Verify the correct prescription and boundary (if using) are selected. Verify prescription is not sending a zero rate. Check section status. Check Section Control status in Toolbox > Overlap and on Run Screen. Restart with a clean (no files) USB stick (CAUTION: Formatting the USB still will remove tasks and associated information, be sure to save all data before deleting). Units: Verify VT units are set correctly in Toolbox >VT >Pref Verify display units are set correctly in Toolbox > Oper Other: If the display does not map, verify the TC steps above are completed and that all the boxes that should be grayed out are. Verify map legends, prescriptions style, data style, data type, and zoom are set correctly Make sure that prescriptions and management files are in ISOXML format (a single Taskdata folder containing at least a Taskdata xml file) on the USB stick. A USB must be in the display for TC to function. You may also have a.cn1 folder in addition to the Taskdata folder. A blank USB may be used and the display will auto create the Taskdata folder. It is recommended to include Product Names associated with Tasks and Prescriptions as there are no parameters in the Pro700 to identify this. Overlap and Boundary control will each trigger the section control icon in the VT. 26

27

6 Manual Configuration Common Scenarios & Settings 28