PROFILINK/908. Modicon S908 Remote I/O To Profibus DP Gateway Process Computer Technology, Inc.

Similar documents
Type of processor Simple applications Simple and medium complexity applications Max. number of

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

M-series DeltaV Controller Interface for PROVOX I/O

S-Series DeltaV Controller Interface for PROVOX I/O

This Datasheet is for the IC693PBM200. Profibus DP Master Module.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

2005/2012 Series Profibus DP Technical Manual

IOD-5101 and IOD-5201 PLC I/O Interface (PIO) Subsystem GE Genius USERS MANUAL. December 21, 2007

USER MANUAL 3170-INTB

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

MPCR Series Profibus-DP Technical Manual

BMEP processor module M580 - Level 1 - Distributed

Modicon TSX Quantum Hot Standby Option Processor

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Operation manual. HDOM-Profibus-V0. More options please visit;

Enhanced Programmable Logic Controller Gateway Specification and Technical Data

PAC BI-DP BIM and 8701-CA-BI Carrier

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

CTI 2500 QUICK START INSTALLATION GUIDE

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

VPGate Manual PROFIBUS to serial

NTX Series Product Comparison

VersaMax Micro and Nano Technical Product Presentation

Installation and Setup

EtherNet/IP to Allen-Bradley DH+ or Remote I/O Gateway AN-X-AB-DHRIO

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

General information. Supply voltage

POINT I/O Family. Chapter. Overview

PROFIBUS DP/CAN Gateway PCA-100. User Manual

POINT I/O Family. Chapter. Overview

G3 Series PROFIBUS DP Technical Manual

OVER YEARS HOT STANDBY EXPERIENCE

Gateway 1400 Reference Manual

Programmable Logic Controller Gateway Specification and Technical Data

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

PS-4100 POWER SUPPLY MANUAL

FNL Modbus TCP Interface

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Making the decision to switch from PLC to PC-based Control has gotten even easier with the introduction of MachineLogic Control Software.

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

PACSystems* RX3i IC695PBM300

Ovation Compact Controller

S800 I/O ABB Automation

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

SYSTEMS ELECTRONICS GROUP

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

Modicon Quantum CHS 110 Hot Standby System Planning and Installation Guide

EL731 PROFIBUS INTERFACE

PROFIBUS Gateway for MCD 3000 Series Soft Starters. User Manual

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

Attention helps you: identify a hazard avoid the hazard recognize the consequences

1395 Node Adapter Board Troubleshooting

Classic IO Modules (M12) for Profibus DP

Enhanced Programmable Logic Controller Gateway Specification and Technical Data

CPU 412H. Function. Parameterizable properties

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

DeltaV Virtual IO Module Network Gateway

Quantum EIO Remote I/O Modules Installation and Configuration Guide

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity

PACSystems* RX3i. RX3i Genius Communications Gateway IC695GCG001-DE. Important Product Information. Release History. Firmware Updates/Upgrades

Profibus Gateway 3E V Technical Bulletin

Copyright: December 2017 Nidec Issue: E

SIPLUS CPU 313C-2DP. Function

Product type designation. General information. Supply voltage

Operator Manual for Profibus

PACSystems* RX3i IC694ALG232

VersaMax IP Input Module

Remote I/O Modules EH-RIO2 Series

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

8 AI RTD Module NJ6020

QUCM Limitorque Controller

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

CIO-777-PR Programming Guide

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i.

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

Introduction. Overview

MTL8000-2/x Series Modular I/O

Connecting UniOP to Simatic S7 Profibus

WebAccess Driver Configuration Manual

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

Ovation Controller Model OCR1100

Data Acquisition, Processing, Analytics, and Display

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

MOD-MUX MODBUS TCP I/O PRODUCTS

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

DEFAULT IP ADDRESS

RTU560 Connections and Settings DIN Rail RTU 560CIG10

CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS

mbc082 Bus Converter

Transcription:

Modicon S908 Remote I/O To Profibus DP Gateway www.profibus.com 2005 Process Computer Technology, Inc.

Tables... 1 Table of Figures... 1 Table of Tables... 1 Revision History... 2 Acknowledgements... 3 Introduction... 1 Application... 1 Features... 1 Table of Acronyms... 1 Specifications... 2 Maximum Power Requirements... 2 Dimensions... 2 Mounting... 2 Overview... 3 About PCT... 3 Profibus-DP... 3 Modicon S908 RIO Network... 4 PROFILINK/908 Functional Overview... 4 Configuration... 6 General... 6 Configuration Sequence... 6 PROFILINK/908 Management Slave... 8 General... 8 Slave Parameters... 8 Gateway Type... 8 Media Redundancy... 8 Report Informational Diagnostics... 9 Max Diag Byte Count... 9 PFB Interface Failover Priority... 9 Failover Priority Threshold... 9 S908 Interface Module... 9 Parameters... 9 Quantum I/O Slave Module... 10 Parameters... 10 Modicon 800 Series I/O Slave Module... 10 Parameters... 11 System Monitor Module... 11 Input Data... 11 PROFILINK/908 Quantum I/O Slave... 12 General... 12 Parameters... 12 Drop holdup word... 12 Supported Quantum Modules... 12 Redundancy Support Module... 13 PROFILINK/908 Modicon 800 Series I/O Slaves... 13 Process Computer Technology, Inc i Process Computer Technology, Inc.

General... 13 Parameters... 14 Holdup Word... 14 Supported Modules... 15 PROFILINK/908 Operation... 17 Startup... 17 Profibus Diagnostics... 17 Indicators, Switches and Connectors... 17 Profibus Interface Indicators... 18 S908 Interface Indicators... 18 General Indicators... 19 Setup Switches... 19 Connectors... 20 Typical Installations... 21 Non-Redundant... 21 Redundant/Simplex Profibus... 22 Redundant/Duplex Profibus... 23 Process Computer Technology, Inc ii Process Computer Technology, Inc.

Tables Table of Figures Figure 1 General PROFILINK/908 Configuration Steps... 7 Figure 2 PROFILINK/908 Front Panel... 17 Figure 3 PROFILINK/908 End Panel... 18 Figure 4 Typical Non-redundant Installation... 21 Figure 5 Typical Redundant Installation with Simplex Profibus Cabling... 22 Figure 6 Typical Redundant Installation with Duplex Profibus Cabling... 23 Table of Tables Table 1 Revision History... 2 Table 2 Acronyms... 1 Table 3 Supported Quantum Modules... 13 Table 4 Supported Modicon 800 Series Modules... 16 Table 5 Profibus Interface Indicators... 18 Table 6 S908 Interface Indicators... 19 Process Computer Technology, Inc 1 Process Computer Technology, Inc.

Revision History 1/2005 Initial release 4/2005 Updated support for holdup word emulation Table 1 Revision History Process Computer Technology, Inc 2 Process Computer Technology, Inc.

Acknowledgements PCT is not affiliated with Schneider Automation or GSE in any manner. Modicon is a trademark of Schneider Automation, Inc. D/3 DCS is a trademark of Novatech Process Systems, LLC PROFILINK/908 2002 Process Computer Technology, Inc. GATEWAY 16000 2002 Process Computer Technology, Inc. Process Computer Technology, Inc 3 Process Computer Technology, Inc.

Introduction Application PROFILINK/908 PROFILINK/908 provides a cost effective method of migrating Modicon Quantum and 800 Series Remote I/O (RIO) onto a Profibus-enabled Distributed Control System (DCS). The PROFILINK/908 can also be used to add Modicon S908 RIO to an existing DCS via Profibus-DP. The PROFILINK/908 transparently translates the S908 protocol to Profibus-DP by appearing as multiple Profibus slaves to the DCS controller. By translating the S908 network and protocol to Profibus, all existing Modicon RIO hardware and associated field wiring remain intact, resulting in a significant cost and time savings. The PROFILINK/908 allows hardware installation and transition time to be reduced from weeks to a matter of hours. Features Supports full S908 network of 32 drops. Modicon Quantum and 800 Series remote I/O are supported on the same PROFILINK/908. Connects to any DCS with Profibus-DP connectivity The PROFILINK/908 is completely configured via the standard Profibus configuration utilities supplied with the DCS. No offline configuration of the PROFILINK/908 is required. Retains all I/O diagnostic functionality DIN Rail mounting or optional 19 rack mount Auto ranging AC or 24 Volt DC input power Redundancy is supported with single or dual Profibus-DP segments Table of Acronyms The following acronyms are used throughout this document: GSD German acronym roughly translated to Device Specification PCT Process Computer Technology, Inc. RIO Remote I/O. In this document, RIO refers specifically to the Modicon Quantum and 800 Series hardware and network cabling. Table 2 Acronyms Process Computer Technology, Inc 1 Process Computer Technology, Inc.

Specifications Maximum Power Requirements 120 VAC 60HZ 240 VAC 50HZ 24 VDC 0.2 Amps 0.1 Amps 0.78 Amps Dimensions The dimensions of the PROFILINK/908 enclosure are 9 (Length) x 5.6 (height) x 5.2 (depth). Mounting The PROFILINK/908 is designed to be DIN Rail mounted An optional chassis is available to mount the PROFILINK/908 in a standard 19 rack. Process Computer Technology, Inc 2 Process Computer Technology, Inc.

Overview About PCT Process Computer Technology (PCT) is an innovative dynamic company serving the process control industry. PCT has been providing engineered solutions for Industrial Automation and Process Control for ten years. The PROFILINK/908, gateway for connecting Modicon Remote I/O to Profibus enabled control systems, is the result of a convergence between two PCT core competencies: PLC systems integration and upgrade hardware development for the D/3 DCS. Many D/3 DCS systems have Modicon Remote I/O utilizing the S908 protocol as the native I/O in place of the original 16000 I/O. After successfully developing the GATEWAY 16000 for connecting the D/3 DCS 16000 I/O to any Profibus enabled control system, PCT hardware and software designers applied their skills to the Modicon Remote I/O. The result is the PROFILINK/908, which is a gateway for the Modicon I/O S908 protocol, and Profibus enabled control systems. PCT was incorporated in 1992 to provide products and services for Factory Automation and Process Control. We specialize in programmable logic controller (PLC) systems integration, D/3 DCS third party hardware upgrades and Profibus solutions for open control systems. For more information about PCT s products and services, refer to the web site at. Profibus-DP Profibus is a defacto industry-standard remote I/O network supported by most major DCS vendors. Profibus DP is specifically optimized to support large volumes of high-speed remote I/O on a single network. Profibus supports I/O equipment from several vendors in a very structured and standardized manner. All Profibus device vendors must supply information on the characteristics of their device via a GSD file. This GSD file (German acronym for Device Specification) contains information used by the control system to present vendorspecific configuration options to the user for new equipment in a consistent manner. Profibus devices are addressed by means of Slave ID (0-125) and offset. Most control systems present the addressing to the user by means of slave, module, offset or channel. Each Profibus slave can be configured with up to 244 bytes of input data and up to 244 bytes of output data. Some control systems and configurations may limit the maximum amount of data a slave can handle. Process Computer Technology, Inc 3 Process Computer Technology, Inc.

Process Computer Technology, Inc (PCT) is a member of the Profibus Trade Organization (PTO). For more information on Profibus and the PTO, refer to the PTO web site at www.profibus.com. Modicon S908 RIO Network S908 is a Remote I/O (RIO) network by Schneider Automation, Inc. s Modicon unit. The network and protocol are optimized for the Modicon RIO hardware and processors. S908 supports, among others, remote I/O hardware from the Modicon Quantum and 800 Series. Modicon Quantum and 800 Series RIO hardware can be mixed on the same network. Both redundant (dual cable) and non-redundant (single cable) configurations are supported. S908 addressing is based upon Drop Number (1-32), Rack Number (1-5), Slot Number (1-16) and Point Number. The PROFILINK/908 transparently translates between the Profibus Slave/Module/Channel addressing and the S908 Drop/Rack/Slot/Point addressing. All module diagnostics are translated to standard or vendor-specific Profibus diagnostics for presentation via the control system s diagnostic reporting mechanisms. Each S908 drop can be configured with up to 128 bytes of input data and up to 128 bytes of output data. For more information regarding the S908 network, Quantum RIO hardware or 800 Series RIO hardware, refer to the Modicon web site at www.modicon.com. PROFILINK/908 Functional Overview The PROFILINK/908 appears as several slaves on the Profibus network. It creates one Profibus Management Slave and multiple Profibus I/O slaves. The Management Slave is used to configure and control the PROFILINK/908 as a unit. The Profibus I/O slaves communicate with the Modicon Quantum or 800 Series RIO hardware. The PROFILINK/908 Profibus Management Slave configures the PROFILINK/908 unit as a whole. By adding and configuring virtual modules into the management slave, the PROFILINK/908 is directed to create Profibus I/O slaves to map to Modicon Quantum and/or 800 Series RIO hardware. This management slave does not correspond to any physical I/O hardware external to the PROFILINK/908. The PROFILINK/908 creates multiple I/O slaves, one for each Modicon Quantum and/or 800 Series RIO rack. The PROFILINK/908 translates between Profibus commands and data and Modicon S908 RIO commands and data. For each RIO rack, the PROFILINK/908 creates an I/O slave for presenting data to the control system. Each module in the RIO rack is configured as a module in the Profibus slave on the control system. Different Profibus slave types are used for Modicon Quantum and 800 Series RIO racks. Output data is received from the Profibus network, translated and presented to the Modicon S908 RIO network. Input data and status are received from the Modicon S908 RIO network, translated and presented to the control system via Process Computer Technology, Inc 4 Process Computer Technology, Inc.

Profibus. This translation is completely transparent to the control system and Modicon RIO hardware. Process Computer Technology, Inc 5 Process Computer Technology, Inc.

Configuration General All configuration of the PROFILINK/908 and RIO modules is performed via the Profibus slave configuration utilities supplied by the control system vendor. No additional utilities are required. This configuration capability is facilitated by device-specific Profibus GSD files supplied by PCT. These files are loaded in accordance with the control system s instructions. Three English language GSD files, corresponding to each Profibus slave type, are supplied with the PROFILINK/908: PROFILINK/908 Management Slave (06D6.GSE), PROFILINK/908 Quantum I/O Slave (06D8.GSE) and PROFILINK/908 Modicon 800 Series I/O Slave (06D9.GSE). Configuration Sequence The general steps involved in configuring the control system for use with PROFILINK/908 are as follows: Install the GSD files on the control system. This is done in accordance with the control system s procedures and varies by system. Note that this step is required to be completed before any PROFILINK/908 units can be configured. Regardless of the number of PROFILINK/908 units installed, this step is only performed once for the control system. Create Management Slave. This Management slave is the central management unit for each PROFILINK/908 and must be created first. The Profibus slave ID of the management slave must be set to an unused Profibus address on the segment and must match the ID set on the thumbwheel switch on the PROFILINK/908 unit shown in Figure 2. Configure the S908 Interface Module in the Management Slave. This module is required to be the first module in the Management slave. This module defines parameters that refer to the S908 RIO network as a whole. For each RIO rack to be configured create and configure a Slave I/O module into the Management slave. This module directs the PROFILINK/908 unit to create a Profibus slave and maps it to the appropriate S908 RIO Hardware. For each RIO rack to be configured create and configure a Profibus I/O slave of the corresponding type (Quantum or 800 Series). Create and configure I/O modules in the Profibus I/O slave. Repeat steps 0-0 for each RIO rack connected to the PROFILINK/908 unit Repeat steps 0-0 for each PROFILINK/908 unit to be connected to the control system. Process Computer Technology, Inc 6 Process Computer Technology, Inc.

Install GSD files on DCS Create Management Slave Create & Configure S908 Interface Module Create & Configure I/O Slave Module Create & Configure Profibus I/O Slave Yes Yes Create and Configure I/O Module Yes More I/O Modules in Rack? No More I/O Slaves? No More PROFILINK.908 units? No Figure 1 General PROFILINK/908 Configuration Steps Process Computer Technology, Inc 7 Process Computer Technology, Inc.

PROFILINK/908 Management Slave General When initially configuring a PROFILINK/908, the Profibus Management Slave for the unit is created and configured first in the control system. The address assigned to the Management Slave in the control system is also set on the thumbwheel switches on the actual unit. Once the slave is created, an S908 Interface Module is configured as the first module in the Management Slave. For each Quantum RIO rack, an S908 Quantum I/O Slave Module is configured into the Management Slave. For each Modicon 800 Series RIO rack, an S908 800 Series I/O Slave Module is configured into the Management Slave. A System Monitoring Module can optionally be configured into the Management Slave to retrieve PROFILINK/908 internal statistics. Slave Parameters Gateway Type The Gateway Type parameter specifies whether the PROFILINK is used in a redundant or non-redundant configuration. Valid values are: Non-redundant This value indicates the PROFILINK is in a non-redundant configuration. Redundant/Fault Tolerant The PROFILINK is installed in a redundant configuration with 2 PROFILINKs connected together. Media Redundancy The Media Redundancy parameter is used to indicate the Profibus cabling used in redundant configurations. Please see the Typical Installations section for the the various cabling methodologies. This parameter is only used for redundant PROFILINK configurations and is ignored in non-redundant configurations. Single Media A single Profibus cable is connected to both units in a redundant PROFILINK configuration. This configuration does not provide redundant Profibus media, but still provides redundant Proflinks and S908 cabling. Redundant Media An independent Profibus cable is connected to each unit in a redundant PROFILINK configuration. This methodology provides fully redundant Profibus cabling as well as redundant PROFILINK and S908 cabling. Process Computer Technology, Inc 8 Process Computer Technology, Inc.

Report Informational Diagnostics The PROFILINK reports several informational diagnostics to aid in configuration and troubleshooting. Since Profibus does not differentiate the severity level of diagnostics reported by a slave, all diagnostics are reported as an error. This parameter allows the PROFILINK to be configured to not report these informational diagnostics unless another error is reported. Report Always Selecting this setting causes the PROFILINK to always report informational diagnostics. On some control systems, this will cause a fault condition to be reported. Report on Errors Only Selecting this setting causes the PROFILINK to mask informational diagnostics unless some other error is reported. Max Diag Byte Count Some control systems cannot handle the Profibus-defined maximum of 237 bytes of diagnostic data. The PROFILINK can be configured to limit the maximum number of bytes of diagnostic data. This parameter should be left at the default of 237, unless the control system documentation explicitly states a smaller maximum. PFB Interface Failover Priority In redundant configurations, this parameter assigns a point value to the Profibus interface to be used in calculating relative failover values. If the difference in failover values exceeds the threshold, the unit will fail to the redundant side. This parameter is ignored in a non-redundant configuration. This parameter should be left at the default value. Failover Priority Threshold When the failover point value difference between the two sides in a redundant configuration exceeds this threshold, a failover occurs. This parameter is ignored in a non-redundant configuration. This parameter should be left at the default value. S908 Interface Module The S908 Interface Module is always the first module configured into the Management Slave for each PROFILINK/908. This module directs the PROFILINK to configure the S908 interface for communicating with the S908 RIO network. Any network-wide parameters are set on this module. Parameters Watchdog Timeout Word Process Computer Technology, Inc 9 Process Computer Technology, Inc.

This is the Watchdog Timeout word used by the S908 interface to disable the S908 interface in the event of an internal failure. This parameter should be left at the default value. Quantum I/O Slave Module Each Quantum RIO rack to be scanned by the PROFILINK/908 must have a corresponding S908 Quantum I/O Slave Module configured into the Management Slave. The parameters to this module determine the mapping between Profibus (Slave Address) and S908 (Drop Number, Rack Number) addressing. In addition, the fail over priority is set for the slave. By configuring this module into the Management Slave, the PROFILINK/908 creates a Profibus slave of the appropriate type and maps it to the corresponding Quantum RIO hardware. Parameters Profibus Slave Address This parameter instructs the PROFILINK as to the Profibus Station number to associate with this Quantum I/O slave. This value must match the value used in the host control system s configuration for the Quantum drop/rack. Failover Priority Failover point value to be used in calculating failover points in a redundant configuration. This value is ignored in non-redundant configurations. This value should be left at the default setting. Drop Number S908 Drop number for the physical I/O associated with this slave. Rack Number S908 rack number for the physical I/O associated with this slave. Quantum remote I/O does not currently support more than one rack per drop. This setting should be left at the default value of 1. Modicon 800 Series I/O Slave Module Each Modicon 800 Series RIO rack to be scanned by the PROFILINK/908 must have a corresponding S908 800 Series I/O Slave Module configured into the Management Slave. The parameters to this module determine the mapping between Profibus (Slave Address) and S908 (Drop Number, Rack Number) addressing. In addition, the fail over priority is set for the slave. By configuring this module into the Management Slave, the PROFILINK/908 creates a Profibus slave of the appropriate type and maps it to the corresponding Modicon 800 Series RIO hardware. Process Computer Technology, Inc 10 Process Computer Technology, Inc.

Parameters Profibus Slave Address This parameter instructs the PROFILINK as to the Profibus Station number to associate with this 800 Series I/O slave. This value must match the value used in the host control system s configuration for the 800 Series drop/rack. Failover Priority Failover point value to be used in calculating failover points in a redundant configuration. This value is ignored in non-redundant configurations. This value should be left at the default setting. Drop Number S908 Drop number for the physical I/O associated with this slave. Rack Number S908 rack number for the physical I/O associated with this slave. System Monitor Module The System Monitor Module provides a means to retrieve PROFILINK internal system statistics as Profibus input data. These values are not of any general value to an end user. This module is documented for informational purposes only and is not supported by PCT. Input Data The System Monitor Module provides 30 bytes of input data as described below. All values and offsets are subject to change without notice. Byte Type Description 0 byte A Side Reboot Count 1 byte B Side Reboot Count 2 long A Side Uptime (in seconds) 6 long B Side Uptime (in seconds) 10 long A Side Polling Time (in milliseconds) 14 long B Side Polling Time (in milliseconds) 18 long Not used 22 long Not used 26 byte A Side Software Major Version 27 byte A Side Software Minor Version 28 byte B Side Software Major Version 29 byte B Side Software Minor Version Process Computer Technology, Inc 11 Process Computer Technology, Inc.

PROFILINK/908 Quantum I/O Slave General Configuring a S908 Quantum I/O Slave Module into the Management Slave directs the PROFILINK/908 to create a Profibus slave and map it to the corresponding Quantum RIO hardware. The actual Profibus I/O slave must then be created and configured into the control system. For each Quantum RIO rack, a Profibus Quantum I/O Slave must be created and configured in the control system. Once the slave has been created, the slave parameters are set. Each module in the rack, starting in slot 1, is inserted and configured. Each module s configuration parameters are then set. For configuration information and options on specific modules, consult the Modicon Quantum documentation. Parameters Drop holdup word The drop holdup time indicates how long the drop should maintain outputs on a communications failure. If the failure occurs in the S908 communications, the Quantum drop hardware implements the holdup functionality. In the event of Profibus communications failure, the PROFILINK simulates the holdup functionality by forcing all outputs to the appropriate value as configured. This value is entered in units of 100 milliseconds. An entry of 3 configures the unit with a holdup time of 300 milliseconds. Supported Quantum Modules The list of supported Quantum RIO modules is shown below. Additional module support may be added in the future. Contact PCT directly for information regarding new module support or to request support for new modules. Module Number 140-CRA-931-00 140-CRA-931-01 140-CRA-932-00 140-DAI-340-00 140-DAI-353-00 140-DAI-440-00 140-DAI-453-00 140-DAI-540-00 140-DAI-543-00 140-DAI-553-00 Function Remote I/O Drop Module (Non-redundant applications only) Remote I/O Drop Module Dual-channel Remote I/O Drop Module Discrete 16 Channel Input, AC 24V, 2x8 Discrete 32 Channel Input, AC 24V, 4x8 Discrete 16 Channel Input, AC 48V, 2x8 Discrete 32 Channel Input, AC 48V, 4x8 Discrete 16 Channel Input, AC 115V, 16x1 Discrete 16 Channel Input, AC 115V, 2x8 Discrete 32 Channel Input, AC 115V, 4x8 Process Computer Technology, Inc 12 Process Computer Technology, Inc.

Module Number 140-DAI-740-00 140-DAO-840-00 140-DAO-842-10 140-DAO-842-20 140-DAM-590-00 140-DDI-153-10 140-DDI-353-00 140-DDI-841-00 140-DDI-853-00 140-DDO-153-00 140-DDO-353-00 140-DDO-843-00 140-DDM-390-00 140-DRA-840-00 140-DRC-830-00 140-ACI-030-00 140-AVI-030-00 140-ACO-020-00 140-AVO-020-00 140-ATI-030-00 140-ARI-030-00 140-AMM-090-00 140-CPS-124-xx 140-CPS-114-xx 140-CPS-111-xx Table 3 Supported Quantum Modules Function Discrete 16 Channel Input, AC 230V, 16x1 Discrete 16 Channel Output, AC 24-230V, 16x1 Discrete 16 Channel Output, AC 100-230V, 4x4 Discrete 16 Channel Output, AC 24-48V, 4x4 Discrete 16 Channel Input, 8 Channel Output, AC 115V Discrete 32 Channel Input, DC 5V, 4x8 Discrete 32 Channel Input, DC 24V, 4x8 Discrete 16 Channel Input, DC 10-60V, 8x2 Discrete 32 Channel Input, DC 10-60V, 4x8 Discrete 32 Channel Output, DC 5V, 4x8 Discrete 32 Channel Output, DC 24V, 4x8 Discrete 16 Channel Output, DC 10-60V, 2x8 Discrete 16 Channel Input, 8 Channel Output, DC 24V Discrete 16 Channel Output, Relay Output (NO) Discrete 8 Channel Output, Relay Output (NO/NC) Analog 8 Channel Input, Unipolar Analog 8 Channel Input, Bipolar Analog 4 Channel Output, Current Analog 4 Channel Output, Voltage Analog 8 Channel Thermocouple Input Analog 8 Channel RTD Input Analog 4 Channel Input, 2 Channel Output 8A Redundant Power supply 10A Power supply 3A Power supply Redundancy Support Module In addition to physical I/O, the redundancy support module can be installed to retrieve module health information as Profibus input data. If installed, this must be the last module in the slave. The Redundancy Support Module returns one bit per module per data path indicating the module can be accessed. This information is useful in redundant systems to determine which data path to use in retrieving input data. PROFILINK/908 Modicon 800 Series I/O Slaves General Configuring a S908 800 Series I/O Slave Module into the Management Slave directs the PROFILINK/908 to create a Profibus slave and map it to the corresponding Process Computer Technology, Inc 13 Process Computer Technology, Inc.

Modicon 800 Series RIO hardware. The actual Profibus I/O slave must then be created and configured into the control system. For each Modicon 800 Series RIO rack, a Profibus S908 800 Series I/O Slave must be created and configured in the control system. Once the slave has been created, the slave parameters (Drop Holdup Time) are set. Each module in the rack, starting in slot 1, is inserted and configured. Each module s configuration parameters are then set. Parameters Holdup Word The drop holdup word indicates how long the drop should maintain outputs in the event of a communications failure. If the failure occurs in the S908 communications, the 800 Series drop hardware implements the holdup functionality. In the event of Profibus communications failure, the PROFILINK simulates the holdup functionality by forcing all outputs to zero after the holdup time has expired. NOTE: All racks on the same drop should have this value set to the same value. If the Holdup Word is set differently for each rack on the same drop, the results are unpredictable. This value is entered in units of 100 milliseconds. An entry of 3 configures the unit with a holdup time of 300 milliseconds. Process Computer Technology, Inc 14 Process Computer Technology, Inc.

Supported Modules Module Number B802 B803 B804 B805 B806 B807 B808 B809 B810 B814 B816 B817 B818 B819 B820 B821 B824 B825 B826 B827 B828 B829 B832 B833 B834 B835 B836 B837 B838 B840 B842 B846 B849 B853 B855 B872 B873 B875 B877 B881 Function 8 Channel Discrete Output 8 Channel Discrete Input Module 16 Channel Discrete Output Module 16 Channel Discrete Input Module 32 Channel Discrete Output Module 32 Channel Discrete Input Module 16 Channel Discrete Output Module 16 Channel Discrete Input Module 8 Channel Discrete Output Module 8 Channel Discrete Output Module 16 Channel Discrete Output Module 16 Channel Discrete Input Module 32 Channel Discrete Output Module 32 Channel Discrete Input Module 8 Channel Discrete Output Module 8 Channel Discrete Input Module 16 Channel Discrete Output Module 16 Channel Discrete Input Module 32 Channel Discrete Output Module 32 Channel Discrete Input Module 16 Channel Discrete Output Module 16Channel Discrete Input Module 16 Channel Discrete Output Module 16 Channel Discrete Input Module 8 Channel Discrete Output Module 8 Channel Discrete Input Module 16 Channel Discrete Output Module 16 Channel Discrete Input Module 32 Channel Discrete Output Module 8 Channel Discrete Output Module 8 Channel Discrete Output Module 16 Register I/O Module 16 Channel Discrete Input Module 16 Channel Discrete Input Module 16 Channel Discrete Input Module 4 Channel Analog Output Module 4 Channel Analog Input Module 8 Channel Analog Input Module 6 Channel Analog Input Module 1 Input, 1 Output Register I/O Module Process Computer Technology, Inc 15 Process Computer Technology, Inc.

Module Number Function B882 2 Input, 2 Output Register I/O Module B883 3 Input, 3 Output Register I/O Module B884 4 Input, 4 Output Register I/O Module B885 6 Input, 6 Output Register I/O Module B886 8 Input, 8 Output Register I/O Module B887 12 Input, 12 Output Register I/O Module B888 16 Input, 16 Output Register I/O Module B883-200 10-channel Thermocouple input module. This module is currently supported only as an 883 Register I/O Module. P810 Power Supply Module J890 S908 RIO communication Module Table 4 Supported Modicon 800 Series Modules Process Computer Technology, Inc 16 Process Computer Technology, Inc.

PROFILINK/908 Operation Startup During startup, the PROFILINK/908 performs the following: The PROFILINK/908 unit performs self tests on the CPU, RAM, Profibus interface and S908 interface. If any of these self-tests fail, the unit will not go online. The S908 RIO configuration and mappings to Profibus are downloaded from the control system via Profibus. This step eliminates all off-line configuration for the PROFILINK/908. Once the complete configuration is downloaded, the PROFILINK/908 starts Profibus communications with the host. The PROFILINK/908 will not start scanning the RIO hardware until good output data has been received and verified. During this state, the PROFILINK/908 will communicate with the RIO network in standby mode to ensure network integrity. Once all output data has been received, the PROFILINK/908 starts normal scanning. Profibus Diagnostics All S908 module diagnostics are either handled internally by the PROFILINK/908 or are translated into standard or vendor-specific Profibus diagnostics for presentation to the use via the standard control system mechanisms. Diagnostic capabilities vary by family and module type within the family. For more information on diagnostics for a particular module, refer to the documentation supplied with the module. Indicators, Switches and Connectors Figure 2 PROFILINK/908 Front Panel Process Computer Technology, Inc 17 Process Computer Technology, Inc.

Figure 3 PROFILINK/908 End Panel Profibus Interface Indicators The two indicator LEDs below the Profibus connector are indicators for the Profibus interface status. The meanings of the indicators shown in Figure 3 are as follows: Upper Lower LED LED Description Green Green Normal operation, communicating with host for all slaves. Orange Green Normal internal operation. Not communicating with Host(s) on one or more slaves. This is also normal operation for standby unit in single Profibus cabling configuration. Red Off The PROFILINK/908 unit is starting. Green/Red Flickering Off The PROFILINK/908 unit is initializing and synchronizing with the host. Table 5 Profibus Interface Indicators S908 Interface Indicators The two indicator LEDs below the S908 network connector are indicators for the S908 interface status. The meanings of the indicators shown in Figure 3 are as follows: Process Computer Technology, Inc 18 Process Computer Technology, Inc.

Standby Remote I/O LED Activity LED Description Off Off The PROFILINK/908 is starting or has failed. Green Off The PROFILINK/908 is initializing configuration information. No scanning of I/O is taking place. Green Red (Dim/Flickering) The PROFILINK/908 unit is operating in Standby mode. This indication is also given when unit has initially configured and is performing consistency Off Red (Dim/Flickering) Table 6 S908 Interface Indicators General Indicators The general indicators shown in Figure 2 are as follows: checks before scanning I/O. The PROFILINK/908 unit is functioning normally in Primary mode. A Side: In redundant configurations, this indicator illuminates to indicate the A side communications gateway. For non-redundant, this indicator is always lit. Primary: In redundant configurations, this indicator illuminates to indicate the unit that is scanning the S908 RIO in Primary mode, i.e. is performing inputs and outputs. Run: When illuminated, indicates the unit is in running mode. Setup Switches Gateway ID: This thumbwheel switch (Fig. 2) sets the Profibus Slave ID for the Management slave for the PROFILINK/908 unit. In redundant configurations, both parts of the redundant unit must be set to the same ID. S1 and S2 (Fig. 3) select the Profibus Baud Rate: Baud Rate S1 S2 (Left = Off) 500KB On On 1.5MB Off On 6MB On Off 12MB Off Off S3 (Fig.3) Simplex/Duplex Profibus: Off = Simplex On = Duplex. Simplex indicates a single Profibus cable is connected to both sides. In duplex mode, a separate Profibus cable is connected to each side and to different Profibus Master interfaces in the control system host. PRI SELECT/AUTO/PRI LOCK Switch (Fig. 2): This switch has no effect in nonredundant PROFILINK/908. AUTO (Center Position): Will allow automatic failover from Primary unit to Backup unit, if Backup unit is running, if a watchdog timeout or a loss of power occurs in the Primary unit. Process Computer Technology, Inc 19 Process Computer Technology, Inc.

PRI SELECT (Momentary): Causes unit to become Primary and scan I/O if unit is running. PRI LOCK: Forces unit to be Primary, if unit is running, and locks out Standby unit from becoming Primary. Connectors Refer to Figure 3 for location of the connectors described below. Profibus Cable: The Profibus cable from the control system host connects to this connector. For redundant Simplex installations, a single Profibus cable connects to both sides of the PROFILINK/908 and to a single Profibus interface in the control system. For redundant Duplex configurations, each side of the PROFILINK/908 is connected to a separate Profibus cable to separate Profibus interfaces in the control system host. Care must be taken to ensure that the A side Profibus cable is connected to the A side PROFILINK/908 and to the A side S908 RIO cable. Refer to Figure 4, Figure 5 and Figure 6 for typical cabling and installation options. S908 Cable: The S908 RIO cable connects to this connector and to the drop modules in each Quantum and 800 Series drop. Redundancy Link: For redundant configurations, the redundancy interlink cable connects both sides of the PROFILINK/908 together. Care should be taken to ensure that the A side of the redundancy interlink cable is connected to the A side PROFILINK/908. For non-redundant configurations, the Redundancy terminator is placed on this connector instead. IPC Link: The interprocessor communication link connects both sides of the PROFILINK/908 together. Status and data is communicated to both sides via this cable. Process Computer Technology, Inc 20 Process Computer Technology, Inc.

Typical Installations Non-Redundant PROFILINK/908 DCS Controller P F B Profibus PROFILINK.908 Quantum Drop S908 800 Series Drop 800 Series Rack 800 Series Rack Figure 4 Typical Non-redundant Installation Process Computer Technology, Inc 21 Process Computer Technology, Inc.

Redundant/Simplex Profibus DCS Controller P F B PROFILINK.908 A Side Profibus PROFILINK.908 B Side Quantum Drop S908 B Side S908 A Side 800 Series Drop 800 Series Rack 800 Series Rack Figure 5 Typical Redundant Installation with Simplex Profibus Cabling Process Computer Technology, Inc 22 Process Computer Technology, Inc.

Redundant/Duplex Profibus DCS Controller P F B B P F B A PROFILINK.908 A Side Profibus B Profibus A PROFILINK.908 B Side Quantum Drop S908 B Side S908 A Side 800 Series Drop 800 Series Rack 800 Series Rack Figure 6 Typical Redundant Installation with Duplex Profibus Cabling PROFILINK/908.doc Process Computer Technology, Inc 23 Process Computer Technology, Inc.