the closed-loop control system

Similar documents
the closed-loop control system

ISO INTERNATIONAL STANDARD

Reliable Environmental Monitoring Systems by Design

Ecotel Free Cool 5-15kW

Cleanrooms and Standards The Road Ahead

A course entitled. Particle counting to ISO Parts 1& 2

CHANGES TO THE STANDARD FOR ISO ISO Cleanrooms and Associated Controlled Environments

Technical Review: European GMP Annex edition

Energy Saving in Cleanrooms

CLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION

Modular CLEANROOM Solutions

TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

Cleanrooms and associated controlled environments. Part 14: Assessment of suitability for use of equipment by airborne particle concentration

Product Handbook SMART CLEANROOM CONTROLS

Cleanroom Standards CLEANROOM TUTORIAL PROGRAMME CLEANROOM CLASSES ISO CLEANROOM STANDARDS (SEP 05)

COPYRIGHTED MATERIAL. Introduction. 1.1 What is a Cleanroom?

SMART VENTILATION MANAGEMENT: CHANGING THE WAY WE THINK ABOUT VENTILATION

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

DATA CENTER AIR HANDLING COOLING SOLUTIONS

PARTICLE MEASUREMENT IN CLEAN ROOMS.

Power Monitoring in the Data Centre: Is the Right Time Now? Jacarta Ltd

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

The Environmental Manager of Pharma S.A. needs a solution to monitory and control the contamination in Pharmaceutical Cleanrooms.

The basis for precision

SALAMANDER. Automated Infrastructure Management

CHORE-TRONICS 3 Whole House Controller

Application of Green Technology For Data Centre

Ease of Use. Data at Your Fingertips LMS PHARMA

FS209E and ISO Cleanroom Standards

Filter Fan Unit Systems. Cleanroom Products

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

FS209E and ISO Cleanroom Standards

Cleanroom Certification Report

Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

HYgro-blu. Instruction Manual

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Temperature and humidity mapping of cleanrooms. Presented by Bernie Prendergast 11 th August 2015

MGE Galaxy /900 kva

10 COMMON TRAPS IN DESIGNING A CLEANROOM

JT Rue Des Pres DATA CENTRE

Thinking Outside The Box Kieron Smith Kingspan Cleanroom Systems

WATER TELEMETRY SYSTEM

Online data sheet. Flow-X FLOW COMPUTER

SISTINE CHAPEL STUDY & PROJECT. NAME Title Carrier HVAC Europe

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Who is Harvard? LeafNut EyeNut. Harvard an overview of the EyeNut system

MAC 10 Family of Fan Filter Units.

Camfil Farr Solution System LCC 2010 software. Last update

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

DATA CENTRE. JT First Tower Lane. Facility Product Description. Data Centre Services

Sumitomo (SHI) Demag Plastics Machinery GmbH

Raytheon s Strategic IT Energy and Resource Management Program

AUTARKIC PROCESS MANAGEMENT

IntElect THE PRECISION MACHINE. Sumitomo (SHI) Demag Plastics Machinery GmbH

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES

White paper What makes mainboards fit for industrial Application?

Agenda. Scope ISO IS : Flowchart. IS : Flowchart. Onderbouwd inschatten en rekenen aan cleanrooms

Howorth Air Technology. Pharmaceutical Aseptic Isolators and Barriers

Commercial Controls. Advanced control for saving time and money

A 2 O Advanced Automated Osmometer

S I T E I N F R A S T R U C T U R E C U R R E N T P R O B L E M S A N D P R O P O S E D S O L U T I O N S

SITRANS F M MAG 8000 SITRANS F. Answers for industry. Precise metering with battery powered water meters.

FX Input/Output (I/O) Modules XM07 and XM14

Lara. Controlled Lab Reactor. Flexible Expandable Upgradeable. Improving the efficiency of your process development...

... with data security and Store & Forward

Reliable Protection with RABS. Restricted Access Barrier System Reliable Protection of Product and Process. Together always one step ahead

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Product Specifications

Test report. Evaluation of particle generation from a chair for use in cleanrooms

Filter Fan Unit LIGHT

Improving monitoring and control hardware cost at Totten Mine

Building Cleanrooms. - Regulations, Air-Handling, Design & Construction -

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

ZEISS TEMPAR Consistent measuring lab certification

ebro has expanded its wide range of loggers in the food sector even further: ebro Data Logger Family EBI 20

A separate CRAC Unit plant zone was created between the external façade and the technical space.

WHITEPAPER CLEAN ROOM DESIGN AND THE ROLE OF FLOORING. An overview of cleanroom design and flooring considerations to ensure regulatory compliance.

Colorex. Salespresentatie Colorex

Total Modular Data Centre Solutions

Trafoguard reliable monitoring of Transformer operating statuses. Transformer control

Industry leading low energy evaporative fresh air cooling.

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

DATA CENTRES POWERED BY EXCEL

Polar PDUs POWER MANAGEMENT

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

BELIMO ENERGY VALVE. Transparent energy monitoring with the Belimo Cloud.

A 2 O Advanced Automated Osmometer

Remote Monitoring. for Building HVAC Systems. A unique combination of human expertise and technology helps ensure optimum operation.

A 2 O Advanced Automated Osmometer

Mission Statement & Company Overview

ht20 EXAMPLE OF APPLICATION Ethernet www/ ftp / smtp Ethernet TCP IP Ethernet/ internal network 1

CA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management

TLS4xx RELIABILITY, PERFORMANCE, EASE OF USE. Keeping the World Moving

NEW WEB BROWSER-BASED APPLIANCE ADDS TO DATA CENTER SECURITY

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

controls Installation and Maintenance Smart S Twin Fan Control System Used with Quietwin fans Year Warranty *12 Year Warranty (UK only) Introduction

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

RX160 range. 6 axis industrial robots

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

HOW TO SELECT A CLEANROOM: MODULAR CLEANROOMS FOR NEW BUSINESSES, NEW PRODUCT DEVELOPMENT

Transcription:

the closed-loop control system

A definitive change in cleanroom technology The Connect 2 Cleanrooms closed-loop control system is designed to ensure the cleanroom operates at optimum effectiveness whilst consuming the minimum of energy. This is achieved by using our ECO-1 Control Panel interfacing with a series of high resolution particle and pressure sensors then using the outputs to vary the volume of filtered air delivered in to the cleanroom to dilute the concentration down to an acceptable level designated by ISO 14644-1 Cleanroom standard. Monitoring and Measurement Through monitoring and measurement of parameters involving power consumption the ECO-1 is the ideal addition for cleanroom users working towards BS EN 16001-2009 Energy and Management System. Allowing users to identify areas where energy can be saved reducing the carbon footprint and maximises cost savings. ECO-1 Features Include Programmable - Day to Night Control Automatic Switching of Lighting Data Logging and Download Alarm Outputs with Remote Signalling Validation / Service Reminders and Scheduling Temperature / Humidity Monitoring Batch Identification Secure Login for Access Control Ethernet Network Compatibility

The Green Reasons Tests have shown that savings of 50% on energy costs compared with a typical cleanroom can be achieved without any reduction in cleanliness. This is, of course, reflected by a corresponding decrease in carbon footprint. A less obvious (but equally impressive) advantage of reducing fan speed whenever possible is that the life of the relevant filters will be considerably extended, causing them to require less frequent replacement. This is because the less air you filter, the fewer particles you catch, and the longer your filters remain effective. Facilities are also provided for automatically reducing the level of lighting and maintaining a base level of airflow when the room is not in use, which again reduces power consumption while ensuring that the room remains a safe and clean environment. "You can t control what you don t measure 100% 75% 50% 25% 0% Standard fan power consumption Closed-loop system power consumption Air contamination levels Cleanroom activity levels Actual particle count

Additional Advantages As well as the particle counter, the control system incorporates a comprehensive set of additional sensors so that room temperature, humidity and pressure can be monitored, logged and used to generate alarms to alert supervisory staff if the cleanroom strays beyond a user-defined set of control parameters. ECO-1 Control Panel This enables blocked or cracked filters, failed fan motors, unexpected levels of temperature and / or humidity etc. to be detected and rectified. There are also facilities for recording a batch I.D. to identify the process to which each set of data relates, and for logging which members of staff were involved with each process. As a side effect of the closed-loop control process, a great deal of useful Management Information is generated and can be used to demonstrate historical conformity to the required level of cleanliness as well as to analyse any variances in production processes. Facilities are provided to log and export this data, which can subsequently be archived for future reference. The basic system envisages a cleanroom with two zones typically a main production zone and an ancillary zone used for activities such as production staff changing into cleanroom attire and back again. Both zones are provided with filtered air at a pressure higher than the atmosphere outside, but if required the system can ensure that pressure in the production zone is always higher than in the ancillary zone, so that particles introduced into the ancillary zone will not enter the production zone.

The main elements of the system are shown below: Control Unit ZONE 2 ZONE 1 Filter Filter 1 Filter 2 Control Panel Temperature/ Humidity Particle Counter If required the system can be expanded by additional Control Units which are driven by the same ECO-1 Control Panel allowing the units to be future proofed for potential growth. ZONE A2 Filter Control A Unit ZONE A1 Filter 1 Filter 2 Temperature/ Humidity Each Control Unit can drive six filters in Zone 1 and two in Zone 2 with its own particle counter and temperature / humidity sensor. Each Control Panel can drive up to 16 Control Units. Control Panel Control B Unit Particle Counter A typical multi-unit system may be configured as detailed to the right. ZONE B2 Filter ZONE B1 Filter 1 Filter 2 Temperature/ Humidity Particle Counter

Distributed by: Over 200 cleanroom installations UK, Europe and worldwide ISO 9001-2008 Accredited Rapid delivery In-house design and manufacture Full showroom and demonstration facilities Leading e-commerce website PROCLEANROOM Heistraat 64 5554 ER, Valkenswaard The Netherlands T: F: E: W: 0031 (0)40 2046931 0031 (0)40 2013981 info@procleanroom.eu www.procleanroom.eu