INTELLIGENT REFRIGERATION CONTROLS. Intelligent Controls

INTELLIGENT REFRIGERATION CONTROLS ADVANCED TEMPERATURE CONTROLLERS, ENERGY MANAGEMENT DEVICES, AND CONNECTIVITY SOLUTIONS

Energy Management Devices

Voltshield. The Sollatek Switcher Range. Sollatek Voltage Protection Products. Protection for all electrical and electronic equipment

THE SOLLATEK AUTOMATIC VOLTAGE SWITCHER (AVS) RANGE Instruction manual

Jockey Pump Controllers

The Sollatek. Microprocessor controlled Stabiliser. Instruction manual

Jockey Pump Controllers

Series SD-3PB Digital THERMOSTAT + TIMER

Millenium II +: general characteristics

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Sollatek SVS Range Voltage Stabilisers User Manual

THERMOSTATS & CONTROLLERS

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

TAC Xenta 121-HP Programmable Heat Pump Application

ML Twin Compressor Controller Installation & User Guide

02/11/2015

MAJOR VA Power Inverter

TECHNICAL DESCRIPTION

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

SLI 15 INVERTER SERIES, 1500 W

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

LED55WPG Programmable LED Driver

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Push-Pull and E-Stop Switches. Datasheet

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

AC ADAPTERS 25W SWITCHING POWER SUPPLY - CLOSED FRAME 60W SWITCHING POWER SUPPLY - CLOSED FRAME

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Magnetically Actuated Safety Interlock Switches

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Communication & Networking

Test devices and Multifunction timer relay

TAC Xenta 121-FC Programmable Fan Coil Application

RT4F-48V/50A-WAC RECTIFIER

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Room unit with PPS2 interface

MCX08M2 Programmable controller

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

SECTION SWITCHBOARDS

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

THE SOLLATEK SUPPRESSOR RANGE Instruction manual

FX05 Controller. FX05 Controller. Features and Benefits Compatible with standard BAS protocols. LON and N2Open plug-in comm.

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

Data Manager Installation Guide

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

FSP018(24)-DHXN3 Series

RT12-240V/2.4kW Rectifier Specification

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

FLUIDWISE DRIVES & CONTROLS ARTIFICIAL LIFT SYSTEMS. franklin-energy.com

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

DFx Series 1e Controller Instruction Manual

Premium Online Series

FSP012(18)-DHXY3 Series

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

PSR UC/ESAM4/3X1/1X2/B

4-step Chiller and Heat Pump Controller

SmartPro 120V 1kVA 650W Line Interactive Sine Wave UPS, Tower, USB, DB9 Serial

ST-Box THE PERFECT SPLIT SOLUTION

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

Fast Route to Reliable Energy Savings ZIP Economizer

IntesisBox SMS - Mitsubishi Electric air conditioners

RT4B-110V/12A RECTIFIER

Installation Manual for D244X Series 24-volt Power Supplies

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

ML Multi Stage Thermostat Installation & User Guide

10 Industrial Media Converters

Programmable controller MCX06C

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Allure EC-Smart-Comfort Series

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

PSR DC/ESP4/2X1/1X2

Product and Application Description

Control Head for the integrated mounting on process valves

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

SMARTSCAN INFORMATION

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Mini Contactors & Overloads

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

DATA SHEET Compact Genset Controller, CGC 200

Datasheet - MZM 100 B ST-1P2PW2REM-A

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Transcription:

FCA THE SOLLATEK FREOCOM the Intelligent Controls

Temperature control, energy saving and voltage protection for all fridges, freezers and coolers. As the problems associated with global warming become more widely recognised, measures to save energy become increasingly desirable and in some cases mandatory. FCA THE SOLLATEK FREOCOM The Sollatek Freocom FCA enables cooler manufacturers to produce a more energy efficient product, thereby reducing CO emissions and 2 reducing electricity bills for vendors. Moreover Sollatek s range of high accuracy units ensures the beverage or chilled product is always served at the optimum temperature. This has the added benefit of allowing the cooler to comply with ever more stringent energy efficiency regulations. Fully user configurable and programmable The Sollatek FreoCom has been designed to provide accurate electronic temperature control for refrigeration and freezers.

02 FCA THE SOLLATEK FREOCOM Neutral Temperature probe Live in Compressor Aux 1 / Aux 2 Temperature probe or door switch Test points Status LEDs Temperature setting dial Programming port FCA Features Highly accurate temperature measurement and control not affected by barometric pressure. Direct retrofit for electro-mechanical thermostats. Controls compressor, lights, fans and defrost heater. Two external remote temperature probes for precise measurement of air, evaporator or condenser temperatures. Temperature dial, user-adjustable. Range can be user customised. Intelligent time delay (TimeSave ). Time and/or temperature controlled defrost. Suitable for evaporator or air control. Energy saving features. Connects to digital display, GSM modem complete with GPS. Can interface to door switch, pressure sensor and other inputs. Wide operating voltage (80Vac to 300Vac) for universal stocking High and low voltage protection. Spike/surge protection. Programmable allows the units to be custom programmed. Programmer and configuration software available. Encapsulated to give water splash resistance for rugged applications. Certifications include: UL, IEC (CE), HazLoc (ATEX). MICROPROCESSOR DIGITAL ENERGY SPLASH TIMED / TEMP USER FAN START UP 16 AMPS CONTROL PROGRAMMABLE THERMOSTAT SAVING PROOF DEFROST ADJUSTABLE CONTROL DELAY UP TO

General system diagram The FCA boasts three outputs and is suitable for controls of compressor, fans, lights and defrost heater. Two temperature sensor inputs are available for air, evaporator and condenser sensing. General system diagram Mobile phone mast Energy saving features are available and programmable in the FCA. GPS satellite Internet Compressor temperature probe Sollatek cloud based server Antenna Door switch Light GMT (modem) remote users Fan SPP01 Programmer FDM3 GMT

FCA Specification FCA Programming Temperature Control* Air and evaporator Defrost Control* Timed or active Energy Saving* Temperature set-back and fan cycling Over temperature protection* Condenser probe FCA12 FCA22 FCA32 Number of relays 16A 16A + 5A 16A + 2 x 5A Output- compressor 16A 250VAC 70A Inrush Current @ 240VAC 140A Inrush Current @ 120VAC 0.75HP @ 120VAC 1.5HP @ 240VAC 4000 VA Breaking Capacity Output - Aux1, Aux2 N/A 5A 250VAC 40A Inrush Current @ 240VAC 80A Inrush Current @ 120VAC 0.125HP @ 120VAC 0.25HP @ 240VAC 750 VA Breaking Capacity Indication 3 off LEDs Data interface To digital display or Mobile modem for remote control and collection of data via a web server Control knob 0-9 with off position Operating Voltage 75 to 300V Continuous Withstand Voltage up to 450V Time Delay* 180 Secs Voltage Protection* High voltage and low voltage including hysteresis Low Voltage Blind Time* 2 Secs Immediate Disconnect Voltage* 75 / 150V High Voltage Blind Time* 0.5 Secs Control Microprocessor Mounting 2 x M4 plastic studs (nuts provided) Programming connector Mini USB connector Door switch Via second probe input or data interface Temperature control -28 C to +25 C Condenser high temperature alarm +30 C to +120 C Working frequency Auto-sense 50/60Hz Surge Protection 6.5kA, <10ns, 160J Power Connections 0.25 fast-on terminals suitable for push-on crimps Environmental Sealed and protected against water, humidity, dust and insects Temperature Probe Type NTC Thermistor Temperature Probe Length 1 meter or 3 meters (different lengths available) Unit dimensions LxWxH (mm) 82 x 42 x 36 (58 with knob) Unit Weight Approx 100g Packing Specifications Supplied in a carton containing 100 units Carton Quantity 100pcs Carton Dimensions (L x W x H) 50.7 x 30.4 x 27.7 cm Carton Gross Weight 13Kg Cartons per Pallet 21 (or 2100 units per pallet) Pallet Dimensions 120 x 102 x 99 cm Pallet Gross Weight 293Kg Certifications IEC - EN 60730 UL - UL873 CSA - C22.2 No.24-93 Hazloc approved FPT SPP FCA Sollatek FPT The FPT (Freo Programming Tool) can be used by the customer to select various functions, configure options and specify parameters. So as to customise the operations of the FCAs, these programmes can be stored on the customer s computers and can be recalled for future use. The parameters are then dowloaded from the computer to the SPP programmer via a standard USB socket. The programmer is then removed from the computer and is then used to programme one or many FCA controllers via the mini USB connector. A simple button on the programme starts the process and two coloured LEDs indicate programming status. The programmer has an internal rechargeable battery and this is recharged when plugged into a computer s USB socket or similar device. Details of the programmable parameters are shown on the following pages. Example programming page All the above mentioned operational parameters are configurable based on the customer s needs. * Programmable

FCA Programmable Parameters FCA Programmable Parameters Item Min Max Units Hardware Configuration Number of Outputs 1 3 Number Number of Temperature Probes 1 2 Number Enable Door Switch Relay#2 Configuration Operation When Compressor is Cycling On Operation When Compressor is Cycling Off Operation During Deforst Operation When Door Switch is Open Normal/Off Door Switch Open Duration 1 255 Secs Door Switch Close Duration 1 255 Secs Relay#3 Configuration Operation When Compressor is Cycling On Operation When Compressor is Cycling Off Operation During Deforst Operation When Door Switch is Open Normal/Off Door Switch Open Duration 1 255 Secs Door Switch Close Duration 1 255 Secs Temperature Control Temperature Blind Time 0 25 Secs Primary Temperature Probe Probe1 or Probe2 Temperature Units C/ F Temperature Dial Type Linear/Discrete Enable Potentiometer Off Position (Dial Marking 0) Dial Marking 0-12 (Cut-In Temp) -28.0 (-18.4) +25.0 (+77.0) C ( F) Dial Marking 0-12 (Cut-Out Temp) -28.0 (-18.4) +25.0 (+77.0) C ( F) Delays and Timers Compressor Relay - Off Protection Delay 0 500 Secs Item Min Max Units Defrost Function Enable Defrost Function Defrost Temperature probe Probe1 or Probe2 Inhibit Defrost Until First Pull-down Event Inhibit Defrost Temperature 0 (+32) +25 (+77) C ( F) Defrost Inhibit Duration 1 255 Hours Defrost Enable Temperature Absolute Temperature -25 (-18.4) +25 (+77) C ( F) Degrees Above Cut-In 0 (0) +20 (+36) C ( F) Type of Defrost Start Time Real/Accumulated/Continuous Defrost Start Time 1 255 Hours Defrost Duration 1 255 Mins Minimum Defrost Duration 1 255 Mins Minimum Duration Between Defrost Cycles 1 255 Hours Defrost Start Temperature -25 (-18.4) +25 (+77) C ( F) Defrost End Temperature -25 (-18.4) +25 (+77) C ( F) Enable Defrost When Probe#1 is Faulty Enable Defrost When Probe#2 is Faulty Enable Defrost Emergency Mode Emergency Mode Defrost Start Time 1 255 Hours Emergency Mode Defrost End Time 1 255 Mins Voltage Protection Enable Voltage Protection High Voltage Disconnect 150 (75) 300 (150) Vac High Voltage Reconnect 150 (75) 300 (150) Vac Low Voltage Disconnect 150 (75) 300 (150) Vac Low Voltage Reconnect 150 (75) 300 (150) Vac High Voltage Blind Time 0 25 Secs Low Voltage Blind Time 0 25 Secs Door Switch Operation Enable Door Switch Operation Operation When Door Switch is Open Normal/Off Door Switch Open Percistance Duration 1 255 Secs Door Switch Close Percistance Duration 1 255 Secs Heater Function Heater Cut-in Temperature -25 (-18.4) +25 (+77) C ( F) Heater Cut-out Temperature -25 (-18.4) +25 (+77) C ( F) Probe#1 Fault Detection Enable Faulty Temperature Probe Detection Type Of Fault Detection Active/Passive Probe Active Fault Detection Compressor Off/Compressor Cycle Compressor Compressor Probe#2 Fault Detection Enable Faulty Temperature Probe Detection Type Of Fault Detection Active/Passive Probe Active Fault Detection Compressor Off/Compressor Cycle Compressor Compressor The above parameters can be programmed into the FCA using the SPP programmer as decribed on page 9

FCA Mechanical drawings Other products in the Freo Range FreoCom FDM3 The FDM3 an LED digital display in standard DIN enclosure with four buttons and menu system for viewing and changing a wide range of parameters in your refrigeration system. This connects directly to an FCA, giving a user interface and alarm display for the temperature controller. The FDM3 is powered directly from the FCA. FreoCom FCD The FCD provides large format display (H:57mm) temperature control and voltage protection for all fridges, freezers, and coolers With highly accurate temperature control and display, it provides a large, bright display visible from a distance of at least 20m. FCA Connections GMT The Sollatek Global Mobile Tracker (GMT) provides essential, accurate and cost effective information to other companies and product vendors. It receive alarms from coolers and remotely diagnoses problems.it can also provide data collection and logging which in turn reduces service calls. Anticipates planned service visits. Also tracks cooler location and Geo-fencing. FreoCom FSP The Freo Stabilised Protector (FSP) provides voltage protection and stabilisation for all fridges, freezers, and coolers. The FSP regulates the mains supply voltage, keeping applications running during wide voltage fluctuations and protecting them from damage. This greatly improves compressor reliability. Stock No Description 92370310 FreoCom FCA12 1xO-P 2xI-P 75-300V 92370320 FreoCom FCA22 2xO-P 2xI-P 75-300V 92370330 FreoCom FCA32 3xO-P 2xI-P 75-300V

Sollatek s expertise extends worldwide through local networks Global and Local With a customer base across the world and a local presence in more than 50 countries, Sollatek is able to provide support services wherever you are. the Intelligent Controls SOLLATEK UK LTD. Tel: +44 (1753) 214 500 sales@sollatek.com www.sollatek.com ISO9001: 2008 accredited company All weights and dimensions are approximate. Specifications are subject to change without prior notice. Sollatek (UK) Limited 2012. All Rights Reserved. SOLLATEK and the SOLLATEK device are the trade marks of the Sollatek group of companies. Sollatek (UK) Ltd. Sollatek House, Waterside Drive, Langley, Slough SL3 6EZ UK FreoCom FCA Brochure Feb 2015 A/I: S/C: 00029924