Operating instructions RFID evaluation unit DTE / / 2016

Similar documents
Operating instructions RFID evaluation unit DTE / / 2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions. Switching amplifier DN0210 DN / / 2015

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Installation instructions Ethernet switch EC / / 2011

Operating instructions. Speed monitor D / / 2014

Operating instructions Evaluation system for flow sensors VS / / 2013

Quick reference guide 3D sensor O3D3xx

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Operating instructions IO-Link master CabinetLine AL19xx

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

Installation instructions Inclination sensor EC2019 EC / / 2013

Operating instructions. Standstill monitor A / / 2011

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions. Monitor FD / / 2013

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

Operating instructions Optical distance sensor. OID20x / / 2014

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Brief instructions Illumination unit O3M950 O3M /00 03/2016

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions Optical distance sensor. OID25x / / 2014

Device manual Inclination sensor 2 axes JN /00 04/2015

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions Optical distance sensor O1D / / 2008

Brief instructions Illumination unit O3M /00 09/2014

Installation Guide. O2Vxxx / / 2015

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions AC010S Compact AS-i E-STOP safety module

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating Instructions

Operating instructions Memory plug E /02 11/2011

Operating instructions Electronic temperature sensor TN /00 04/2011

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Operating instructions Electronic pressure sensor PN7xxx

Hardware Manual RM Display 2501 S01..S04

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

System manual AS-i safety monitor AC041S /00 05/2013

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Hardware Manual RM Display 2401

Installation Instructions Temperature transmitter TAA /00 06/2011

Operating Instructions IO-Link Master with Modbus TCP interface DataLine 8 Ports IP 65 / IP 66 / IP 67 AL1342

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Power supply module, bus connection module

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Operating instructions RFID read/write head with IO-Link DTIxxx

Operating instructions. Monitor FS-1 / FS-1N / / 2013

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

QUINT-BUFFER/24DC/24DC/40

Operating instructions Pressure sensor. PE30xx / / 2010

Operating instructions Monitor FD-2 DR2005 DR / / 2007

Operating instructions Binary level sensor LMC / / 2014

Operating instructions Electronic temperature sensor TN7511

PHOENIX CONTACT - 07/2006

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

Operating Instructions IO-Link Master with EtherNet/IP interface DataLine 4 Ports IP 65 / IP 66 / IP 67 AL1320

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

MINI-PS AC/10-15DC/8

Hardware Manual RM Display 1001

Device manual Inclination sensor 2 axes. JN2301 from firmware /00 05/2016

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

FL MC 2000E (SM40) LC

Operating instructions IO-Link INLINE DISPLAY 1.44" E30430

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

icore Kiosk system Installation Guide

Operating and mounting instructions

TRIO-DIODE/12-24DC/2X10/1X20

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

Operating Manual FPGA-based High-Speed Micro-PLC

Operating instructions Pressure sensor. PN70xx / / 2012

QUINT-PS/ 1AC/24DC/ 5

BACnet/IP Web Interface

SK CU4-PNT-C Part number:

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

SUBCON-PLUS-PROFIB...

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

CPCI-PS24 24V-Power Supply

EX-RC1 Remote I/O Adapter

Transcription:

Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016

Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4 2.2 Installation and connection...4 2.3 Tampering with the device...5 3 Functions and features...5 3.1 Configuration via Ethernet interface...5 3.2 RFID antennas...6 4 Function...6 5 Installation...6 5.1 Installation distance...6 5.2 Installation orientation...7 5.3 Mounting options...7 5.3.1 Mounting on DIN rail...7 5.3.2 Removal...8 5.3.3 Mounting plate...8 6 Electrical connection...9 6.1 AUX voltage supply...9 6.2 Field bus connection PROFINET IO Port 1 / Port 2...10 6.2.1 Factory setting of the Ethernet parameters...10 6.3 Process connections IO1... IO4... 11 6.4 Functional earth connection....12 6.4.1 Mounting on DIN rail...12 6.4.2 Mounting plate...12 7 Operating and display elements...13 7.1 Reset to factory settings...13 7.2 LED indicators...13 7.2.1 LED AUX...13 7.2.2 LED PROFINET Port 1 / Port 2...14 7.2.3 LED SF...14 7.2.4 LED BF...15 2

7.2.5 LEDs IO1... IO4...15 7.2.6 Special device LED indications...17 8 Technical data...17 8.1 Data sheets...17 8.2 Device manual...17 9 Maintenance, repair and disposal...18 10 Approvals/standards...18 11 Scale drawing...18 Licences and trademarks Microsoft und Internet Explorer are registered trademarks of Microsoft Corporation. All trademarks and company names are subject to the copyright of the respective companies. 3

1 Preliminary note 1.1 Notes on this document This document applies to the RFID evaluation unit DTE101. It is part of the device and contains information about the correct handling of the product. This document is intended for qualified electricians. These specialists are people who are qualified by their training and their experience to see and to avoid possible hazards that may be caused during operation of the device. Read this document before use to familiarise yourself with operating conditions, installation and operation. Keep this document during the entire duration of use of the device. 1.2 Symbols used Instructions > Reaction, result [ ] Designation of pushbuttons, buttons or indications Crossreference Important note Noncompliance can result in malfunction or interference. Information Supplementary note 2 Safety instructions 2.1 General Observe these operating instructions. Adhere to the warning notes on the product. Nonobservance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can affect the safety of operators and machinery. 2.2 Installation and connection The device must only be installed, connected and put into operation by a qualified electrician as the safe function of the device and machinery is only guaranteed when installation is correctly carried out.the installation and connection must 4

comply with the applicable national and international standards. Responsibility lies with the person installing the device. This is a class A product. The device may cause radio interference in domestic areas. In this case it can be necessary for the user to take appropriate measures. 2.3 Tampering with the device Tampering with the device is not allowed and will lead to an exclusion of liability and warranty. Tampering with the device can affect the safety of operators and machinery. Do not open the device. Do not insert any objects into the device. Prevent metal foreign bodies from penetrating. 3 Functions and features The RFID evaluation unit DTE101 integrates a PROFINET IO interface and 4 channels for the connection of field devices. Each channel can be used either for the connection of an RFID antenna or as input/output to IEC 61131. The device controls the data exchange to the RFID antennas or the sensor/actuator level. communicates with the higherlevel control level via PROFINET IO. allows device configuration via a web server. Application examples: Material flow control in production lines Warehouse management by the automatic detection of stored products Tank management, order picking or product tracking 3.1 Configuration via Ethernet interface 10 Mbps and 100 Mbps TCP / IP Transport Control Protocol / Internet Protocol UDP User Datagram Protocol IT functionality: HTTP server M12, twisted pair 5

3.2 RFID antennas The device supports up to four RFID read/write heads of type ANT41x / ANT51x from ifm electronic gmbh. You can find information about the matching read/write heads on our website at: www.ifm.com data sheet search ANT41 or ANT51 4 Function You can find detailed information about the function of the system in the device manual at: www.ifm.com data sheet search DTE101 Operating instructions 5 Installation 5.1 Installation distance Due to the internal heating of the device a minimum distance to other objects of 10 mm is to be taken into account during installation. A = 10 mm 6

5.2 Installation orientation The installation orientation can be freely selected. In a wet environment upsidedown mounting is not permitted. 5.3 Mounting options 5.3.1 Mounting on DIN rail The device can be installed on a DIN rail of type NS35/15 or NS35/7.5. 1. Angle the device and place the fixing clamp onto the upper edge of the DIN rail. 2. Press device down. 3. Simultaneously rotate the device in the direction of the DIN rail. 7

5.3.2 Removal 1. Press device down. 2. Simultaneously rotate the device away from the DIN rail. 3. Remove the device from the top. 5.3.3 Mounting plate The device can be fixed to a mounting plate using 2 screws (M4 x 35 or longer). M4 M4 This installation mode is recommended for vibration and shock requirements. 8

6 Electrical connection The device must be connected by a qualified electrician. Disconnect power before connecting the device. Observe the national and international regulations for the installation of electrical equipment. Ensure voltage supply to EN 50178, SELV, PELV. Connect the device according to the indicated pin connection. A total current consumption of the device of 3 A must not be exceeded. Please note the following points to ensure protection rating IP 67: Cover the unused sockets with protective caps. Tighten all protective caps and connectors with a tightening torque of 1 Nm. You will find matching accessories at www.ifm.com Accessories Protective cap Torque wrench ifm article number E73004 E70390 6.1 AUX voltage supply Connect the device to the voltage supply using an M12 connection cable. Pin Connection 5 1 2 4 3 1 24 V DC 2 Not used 3 0 V 4 Not used 5 Not used You can find matching connection cables at: www.ifm.com data sheet search DTE101 Accessories 9

6.2 Field bus connection PROFINET IO Port 1 / Port 2 Connect the device to a PROFINET IO controller using a suitable M12 Ethernet connection cable. 1 2 Pin Connection 1 TD+ 4 3 2 RD+ 3 TD Note: screened connection cable required 4 RD 6.2.1 Factory setting of the Ethernet parameters The following values are preset on delivery of the device: Parameters Factory setting IP address 192.168.0.79 Gateway address 192.168.0.100 Subnet mask 255.255.255.0 Autonegotiation DHCP on off The settings can be changed via the unit s webserver or via the PROFINET IO controller. 10

6.3 Process connections IO1... IO4 Each process connection can be used as input/output to IEC 61131 or for connection of an RFID read/write head. The connections are set via the hardware configuration of the PROFINET IO controller. Pin Connection 5 1 2 4 3 1 L+ 2 Switching input (I/Q) 3 L 4 Switching output (C/Qo) or input (C/Qi) 5 Not used The evaluation unit has to be disconnected before field units are connected. Please note that the total current consumption of the device must not exceed the value of 3 A. You can find detailed information about the available operating modes in the device manual at: www.ifm.com data sheet search DTE101 Operating instructions 11

6.4 Functional earth connection. To ensure troublefree operation the device must be connected to an earth potential free from external voltage. 6.4.1 Mounting on DIN rail The connection is made automatically via the DIN rail. Note that the DIN rail must be connected with the earth potential. 6.4.2 Mounting plate When the device is fixed on a mounting plate, connection is made via the left fixing screw. Note that the plate must be connected with the earth potential. 12

7 Operating and display elements 7.1 Reset to factory settings The Ethernet parameters can be reset to the factory settings. Take the following steps: Remove all cable connections from the device. Insert an electrically conductive bridge between pin 1 and pin 3 on the process connection IO3. Connect device with the voltage supply and wait until the yellow LED indication on AUX and IO3 flashes at approx. 8 Hz. Disconnect the device from the voltage supply and connect it again. > > The settings are reset. 7.2 LED indicators The device indicates the current status of the interface via the status LEDs. 7.2.1 LED AUX LED green LED yellow Status Note Off Off No voltage supply U AUX < 5 V Flashes at 2 Hz Voltage supply too low 5 V U AUX 18 V Off Voltage supply OK 18 V U AUX 36 V 13

7.2.2 LED PROFINET Port 1 / Port 2 LED green LED yellow Status Note Off Off No connection to another Ethernet counterpart Link status "no link" Off Connection to Ethernet counterpart exits, no data exchange Link status "link", "no traffic" Flashes sporadically Connection to Ethernet counterpart exists, data exchange running Link status "link", "traffic" 7.2.3 LED SF LED red LED green Status Note off off no voltage supply check voltage supply off flashes "Node flash test", initiated by PROFINET IO controller off on normal operation flashes off error on channel level on off error on device level overload temperature internal fault undervoltage temperature flashes flashes selftest starting phase of the device 14

7.2.4 LED BF LED red LED green Status Note off off no voltage supply check the voltage supply off flashes PROFINET IO controller is in STOP mode off on PROFINET IO controller is in RUN mode flashes off connection to the PROFINET IO controller is established, no valid configuration check configuration on off no connection to PROFINET IO controller check connection flashes flashes selftest starting phase of the device 7.2.5 LEDs IO1... IO4 The LED indications of the process connections differ with each connection configuration. Use as input to IEC 61131 LED green LED yellow Status Note Off Off Interface deactivated Interface in PROFINET IO controller not configured Off Interface activated, input on L level (0 V) Interface activated, input on H level (24 V) Flashes at 8 Hz Flashes at 8 Hz Overload or short circuit 15

Use as output to IEC 61131 LED green LED yellow Status Note Off Off Interface deactivated Flashes at 8 Hz Off Flashes at 8 Hz Use with RFID read/write heads Interface activated, output Lactive (0 V) Interface activated, output Hactive (24 V) Interface in PROFINET IO controller not configured Overload or short circuit LED green LED yellow Status Note Off Off Interface deactivated Flashes at 2 Hz Flashes at 8 Hz Off Off Flashes at 8 Hz Interface activated, antenna off Interface activated, tag not in the field Interface activated, tag in the field Overload, shortcircuit or communication error Interface in PROFINET IO controller not configured 16

7.2.6 Special device LED indications LED Status Note Green AUX LED on Yellow AUX LED flashes at 8 Hz Yellow IO1...IO4 LEDs flash at 8 Hz Device is in the service mode "emergency system started". A firmware update is necessary and can be executed via the web server. Green AUX LED on Yellow AUX LED flashes at 8 Hz Green IO1...IO4 LEDs flash at 8 Hz Major error, device has to be returned. Hardware fault or permanent data in the device are corrupt. Yellow IO1...IO4 LEDs flash at 8 Hz Green AUX LED on Yellow AUX LED Flashes at 8 Hz Reset to factory settings Yellow IO3 LED flashes at 8 Hz 8 Technical data 8.1 Data sheets Data sheets can be found at: www.ifm.com data sheet search DTE101 8.2 Device manual The device manual can be found at: www.ifm.com data sheet search DTE101 operating instructions 17

9 Maintenance, repair and disposal Dispose of the device in accordance with the national environmental regulations. 10 Approvals/standards The EC declaration of conformity and approvals can be found at: www.ifm.com data sheet search DTE101 Approvals 11 Scale drawing 85 46,2 75 32,2 M12x1 M4 57,5 115 M12x1 43,5 18

19