Starters. Power. Manual Motor Low Voltage Starters 600, 609, 609U, 609TU. 600 Manual Starting Switches 609 Manual Starting Switches

Similar documents
Large Frame IEC Contactors

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

Allen-Bradley Drives

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Allen-Bradley Bulletin 100 Contactors

Controls Enclosed Non-Combination Starters - PESW Series

3RA13, 3RA14 Contactor Assemblies

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IEC Contactors. Auxiliary Contact Blocks GENERAL

Mini Contactors & Overloads

Product Description. Table of Contents

Protection Equipment

Allen-Bradley 700-K40E-DJ

Motor Protection Solutions. Bulletins 193, 592, 809S, 813S, 814S, 817S and 825-P

194E FA 32 E P11 P11 6

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

EU Declaration of Conformity

Essential Components Catalog

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

60103 Circuit Breaker

IPS INTELLIGENT PUMP STARTER

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

E1 Plus Electronic Overload Relay

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

RB60 RANGE. Miniature circuit breakers

E1 Plus Overload Relay Specifications

Industrial Controls Training Systems

Bulletin 280E/281E, 284E ArmorStart Distributed Motor Controller Product Overview

Technical Information

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

SSW06. Soft Starters.

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Lightning and Surge Arresters

Revolutionizing control wiring

IEC Contactor Specifications

Switchgear 1.1. CONTACTORS - Installation. Page 1.2. Page 1.2. CONTACTORS - Mini. Page POLE RELAY. Page 1.3. CONTACTORS - Standard Frame

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 290/291, 294 ArmorStart LT Distributed Motor Controllers Description/Features

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

RiLine Compact The smart power distribution system

Solid-State Contactors

TeSys IEC Contactors and Overload Relays

Issue Abbreviated BSP-Numbering system AUMA MATIC BASIC types AMB and Basic Compact (AUMA Actuators Inc.) Uncontrolled copy!

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

Page 1 of 8 Knowledgebase Technote ID # /18/2013

78 Series Electromechanical Relay Selection Guide

Series CA7 Contactors

DC-Switch With G20S/G20. next

How to Control and Monitor a C441 Motor Insight via DeviceNet

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

SMARTSTART MOTOR STARTERS

Rotary switches T and switchdisconnectors. reliable switching, disconnection, control and operation

sirius Switching. Protecting. Starting. SIRIUS Product Overview

Applying branch circuit breakers and supplementary protectors in North America

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

UL 489 DIN Rail Miniature Circuit Breakers

PowerFlex 400 AC Drive Guide Specification

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Series SD-3PB Digital THERMOSTAT + TIMER

General Purpose Control Components Welcome to the Control Catalog!

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Enclosed SMC-3, SMC Flex, and SMC-50 Smart Motor Controllers

CP30F Series Circuit Protector for Improving Safety and Wiring Workability

UL 489 DIN Rail Miniature Circuit Breakers

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...

Crane Control Contactors and Relays

Circuit Breakers Type CTI 25M, CTI 45MB

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

High Voltage Contactors

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

Contactors and Contactor Assemblies

UL 489 DIN rail branch circuit breakers

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Application Techniques CENTERLINE 2100 Motor Control Centers

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006. Electrical Interlock (2 req d)

Motor protection circuit breakers

Series CA7 Contactors

Device manual AS-i PowerSwitch ZB0028 ZB0040

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

Transcription:

Starters Manual Motor Low Voltage Starters 600, 609, 609U, 609TU Compact design Undervoltage protection Manual operation with overload protection Ideal for low HP applications, up to 10 HP three phase Manual motor starters are specifically designed for full voltage motor starting applications where remote push button control is not necessary. They are ideally suited for starting and protecting smaller motors frequently used for fans and blowers. 600 Manual Starting Switches 609 Manual Starting Switches Single phase Starting and overload protection of small AC/DC motors up to 1 Hp Single and three phase Contact position indicator Locking feature Reversing and 2-speed Wide range of enclosures, including hazardous location 609U & 609TU Manual Starting Switches Undervoltage protection Single and three phase Contact position indicator Locking feature Wide range of enclosures Push button or toggle switch

Product Selection 600 Manual Motor Starters Type Toggle No. of Poles Open Type Without Enclosure Includes Legend Plate Switch Only Type 1 General Purpose Enclosure Surface Mount Type 1 General Purpose Enclosure Flush Mount Includes Flush Plate Only 1 600-TOX4 600-TAX4 600-TQX4 2 600-TOX5 600-TAX5 600-TQX5 Key 2 600-TOX49 600-TAX49 600-TQX49 Lever 1 600-TOX149 600-TAX149 Toggle Switch with Neon Pilot Light (115 or 230V) 1 600-TOX216 600-TAX216 600-TQX216 2 600-TOX109 600-TAX109 600-TQX109 Key 2 600-TOX110 600-TAX110 600-TQX110 Switch and Hand-Off-Auto Selector Switch (for use on AC only) Toggle 2 600-TAX9 600-TQX9 Switch with Neon Pilot Light and Hand-Off-Auto Selector Switch (115 or 230V, AC only) Toggle 2 600-TAX142 600-TQX142 Key 2 600-TAX145 609 Manual Motor Starters Max. Hp Rating Motor Voltage, 60 Hz Open Type without Enclosure Type 1 General Purpose Enclosure Surface Mount Type Phase Size 115V 200V 230V 460 575V 0 1 2 609-AOX 609-AAX Push Button Toggle Lever 1 3 1 3 1 2 3 609-BOX 609-BAX 1 P 3 5 609-XOX 609-XAX 0 3 3 5 609-AOW 609-AAW 1 7-1/2 7-1/2 10 609-BOW 609-BAW 0 1 2 609T-AOX 609T-AAX 1 2 3 609T-BOX 609T-BAX 1 P 3 5 609T-XOX 609T-XAX 0 3 3 5 609T-AOW 609T-AAW 1 7-1/2 7-1/2 10 609T-BOW 609T-BAW Heater Elements All single-phase starters require one heater element and three-phase starters require three heater elements. Product selection for 609U & 609TU is available at http://ab.rockwellautomation.com/motor-control/nema-manual-motor-starter

Starters IEC Eco Starters 190E/191E Meets UL/CSA IEC standards 5 23 A Type 1 and 2 coordination AC or DC coils available Shares common accessories with 100-C/100-K contactors and 140M motor protection circuit breakers The 190E/191E motor controllers can be used in a variety of applications. These starters can be used in a group motor application or as a stand-alone product without any additional short-circuit protection in the motor branch circuits. Rated Type F combination motor controllers (UL/CSA). Options for Field Assembly 190/191-E starters can be field assembled. Simply select the following: 100-K/104-K miniature contactor (page 1-28 or 100-C/104-C contactor (page 1-29) 140M motor protection circuit breaker (page 1-3) Eco connecting module (catalog number 140M-C-PEK12, 140M-C-PEC23) 140M Motor Protection Circuit Breaker Eco Connecting Module 100-C Contactor Reversing 104-K Reversing Miniature Contactor Direct on Line

Product Selection IEC Eco Starters with AC and DC-Operated Contactors Motor Current Adjustment Range [A] 3-Phase kw (50 Hz) 3-Phase Hp (60 Hz) Max. Short- Circuit Current Type 1 Coordination [ka] 400/415V 460V 480Y/277V With 100-K IEC Miniature Contactors Direct on Line Reversing With 100-C IEC Contactors Direct on Line Reversing 0.10 0.16 0.02 65 190E-KMN 2-CA16X 191E-KMN 1-CA16X 190E-AN 2-CA16X 191E-AN 3-CA16X 0.16 0.25 0.06 65 190E-KMN 2-CA25X 191E-KMN 1-CA25X 190E-AN 2-CA25X 191E-AN 3-CA25X 0.25 0.40 0.09 65 190E-KMN 2-CA40X 191E-KMN 1-CA40X 190E-AN 2-CA40X 191E-AN 3-CA40X 0.40 0.63 0.12 0.18 65 190E-KMN 2-CA63X 191E-KMN 1-CA63X 190E-AN 2-CA63X 191E-AN 3-CA63X 0.63 1.00 0.25 0.5 65 190E-KMN 2-CB10X 191E-KMN 1-CB10X 190E-AN 2-CB10X 191E-AN 3-CB10X 1.00 1.60 0.37 0.55 0.5 1 65 190E-KMN 2-CB16X 191E-KMN 1-CB16X 190E-AN 2-CB16X 191E-AN 3-CB16X 1.60 2.50 0.75 0.75 1.5 65 190E-KMN 2-CB25X 191E-KMN 1-CB25X 190E-AN 2-CB25X 191E-AN 3-CB25X 2.50 4.00 1.1 1.5 1.5 3 65 190E-KMN 2-CB40X 191E-KMN 1-CB40X 190E-AN 2-CB40X 191E-AN 3-CB40X 4.00 6.30 2.2 3 5 65 190E-KNN 2-CB63X 191E-KNN 1-CB63X 190E-AN 2-CB63X 191E-AN 3-CB63X 6.30 10.0 3.0 4.0 5 7.5 65 190E-KPN 2-CC10X 191E-KPN 1-CC10X 190E-BN 2-CC10X 191E-BN 3-CC10X 10.0 11.0 5.5 7.5 30 190E-KPN 2-CC16X 191E-KPN 1-CC16X 10.0 12.0 4.0 5.5 7.5 30 190E-BN 2-CC16X 191E-BN 3-CC16X 10.0 16.0 5.5 6.3 7.5 10.0 30 190E-CN 2-CC16X 191E-CN 3-CC16X The catalog number as listed is incomplete. Select a coil voltage code from the table below. Coil Voltage s for AC and DC Control AC Control 24V DC Control KJ 24V, 50/60 Hz ZJ Standard (190E/191E-K) D 110V, 50 Hz/120V, 60 Hz Integrated diode DJ (190E/191E-K) KF 230V, 50/60 Hz Electronic with KA 240V, 50/60 Hz EJ integrated diode (190/191E-A...D) Product Selection Tools Available online or for download, our tools help you access info while in the office or on the go. www.rockwellautomation.com/support/ selection.page

Starters Enclosed Starters, IEC 109-C/105-C 109-C Direct On-line, Non-combination Starters 100-C Contactor Electronic motor protection Disconnecting means to be provided separately Factory modifications available 105-C Reversing, Non-combination Starters 104-C reversing contactor Electronic motor protection Disconnecting means provided separately Factory modifications available Compact Installation Plastic enclosures provide a compact, cost effective solution to help reduce machine space and expand product flexibility. Wiring Made Easy Metal enclosures now feature component wiring color-coded by function. The wiring sleeve-cover corresponds to a colored label on the terminal block, reducing wiring errors and allowing for quicker installation times. 100-C Contactor Auxiliary Sensor Control Command Pluggable terminal block E1 Plus Electronic Overload Relay Indication Color-coded sleeves

Product Selection IEC Enclosed Starters Type Direct on Line Starter 109-C Reversing 105-C Ratings AC-3 E1 Plus Overload Relay IP66, Large Molded Plastic IP42, Type 1 Metal IP66, Large Molded Plastic IP42, Type 1 Metal Max I e Standard Motors AC-3, 3 Motor Current Setting Range With START/STOP Multifunction Push Button (2 Functions) and Reset With QC Wiring Technology With FORWARD/OFF/REVERSE Multifunction Push Button (3 Functions) and Reset With QC Wiring Technology [A] [kw] [A] 9 4 1.0 5.0 109-C09L(X)E1C-1M-7 109-C09AD-XXX 105-C09L(X)E1C-1M-7 105-C09AD-XXX 9 4 3.2 16.0 109-C09L(X)E1D-1M-7 109-C09AD-XXX 105-C09L(X)E1D-1M-7 105-C09AD-XXX 12 5.5 3.2 16.0 109-C12L(X)E1D-1M-7 109-C12AD-XXX 105-C12L(X)E1D-1M-7 105-C12AD-XXX 16 7.5 3.2 16.0 109-C16L(X)E1D-1M-7 109-C16AD-XXX 105-C16L(X)E1D-1M-7 105-C16AD-XXX 23 11 5.4 27.0 109-C23L(X)E1E-1M-7 109-C23AD-XXX 105-C23L(X)E1E-1M-7 105-C23AD-XXX 30 15 9.0 45.0 109-C30L(X)E1F-1M-7 109-C30AD-XXX 105-C30AD-XXX 37 18.5 9.0 45.0 109-C37L(X)E1F-1M-7 109-C37AD-XXX 105-C37AD-XXX 43 22 9.0 45.0 109-C43L(X)E1F-1M-7 109-C43AD-XXX 105-C43AD-XXX Accessories E1 Plus DeviceNet and protection module E1 Plus EtherNet/IP and protection module E1 Plus jam protection module E1 Plus ground fault module E1 Plus ground fault/jam module E1 Plus PTC module E1 Plus remote reset module 193-EDN 193-ETN 193-EJM 193-EGF 193-EGJ 193-EPT 193-ERR Need Help? The Rockwell Automation Support Center is your 24/7 support for the answers you need now. www.rockwellautomation.com/ support/overview.page Coil Voltage s for AC and DC Control KJ D KF KA AC Control 24V, 50/60 Hz 110V, 50 Hz/120V, 60 Hz 230V, 50/60 Hz 240V, 50/60 Hz DC Control with Integrated Surge Suppression DJ 24V (60...97 A only) EJ 24V, Electronic (9 55 A only) ED 110V, Electronic (9...55 A only)