User s manual. Programmable panel meter IPD

Similar documents
R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

SVO CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITHOUT NEUTRAL

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Process displays For current and voltage

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Neon pr. ph/ ORP measurement. Applications. Description

SX90 Process Controller

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Digital Panel Meters Modular signal s conditioner Type USC-DIN

RTD Temperature acquisition converter WJ25

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

DINALOG A 144 x 36 A1400 Light-Strip Indicator

/8 DIN Motorized Valve Controller

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Masibus Automation And Instrumentation Pvt. Ltd.

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

/8 DIN Universal Process Indicator

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

TRANSDUCER T4311, T4411

NetBiter I/O Extender User Manual

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

LBVR1718. Description. Features channel paperless recorder

Trident and Trident X2 Digital Process and Temperature Panel Meter

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

iologik 4000 Series (M) Modules

Digital Panel Meters Modular Indicator and Controller Type UDM35

XT-9100 Technical Bulletin

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Expansion Module HZS 541-1S

MIC-2 MKII, Multi-instrument DATA SHEET

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

SINGLE-CHANNEL PROCESS INDICATOR series 8001

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

SX 6000 Paperless Recorder

GFK-2415A March Type of sensor connection

Hotel Room Controller

LAUREL ELECTRONICS, INC.

Tempco Instruction Manual

C160 Wall-/Pipe Mounted Universal Process Indicator

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

UNIVERSAL CURRENT CONVERTER

iothinx 4500 Series (45MR) Modules

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Wall-/Pipe Mounted Universal Process Indicator

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Signal Isolators & Conditioners

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

MODEL: R1M-GH. PC Recorders R1M Series

KEHAO INSTRUMENT. Xiamen Kehao Automation Co., Ltd KH102 INTELLIGENT PROCESS INDICATOR KEHAO INSTRUMENT

P2-04DA Analog Output. Removable Terminal Block Specifications

Signal Isolators & Conditioners

FX Input/Output (I/O) Modules XM07 and XM14

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

FEATURES DESCRIPTION FEATURES

GE Fanuc IC694ALG221. Rx3i PacSystem

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

P3-SCM. General Specifications

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

VersaMax IP I/O Module

Control instruments GUARDIAN 2 - GUARDIAN 3

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

Signal Isolators & Conditioners

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Analog Input Modules

PXR Series Advanced Self-Tuning Temperature and Process Controllers

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Specification Sheet For electronically commutated motors

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

JSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value,

Samba PLC+HMI SM35-J-RA22

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

RS-485 I/O Modules: ADAM-4000

Transcription:

User s manual Programmable panel meter IPD

Assembly Wall assembly: +0,5 +0,2 Window of 46 x 91 mm (2.5" x 3.5" ) Made with ABS (UL94-HB) -0-0 General cares in the installation The equipments must not be placed in environments too near to power elements such us circuit breakers, triacs, rectifier bridges, high voltage transformers, etc. As far as possible, the equipments will be isolated from the emitters of electrical disturbances by means of, for instance, a shield connected to ground. NO YES The equipments will not be exposed to extreme temperatures and humidities: Maximum room temperature for optimal operation: 40ºC Maximum room humidity without precipitation: 90%. NO YES The connections must be done separating, phisically, the measurement signals from the control or power signals. Do not use the same connection for the power supply of the equipment and for the control line of the circuit breakers, motors, etc. NO YES In a general way, it is recommended to use an exclusive supply line for the equipments connected directly from the main and provided with the appropiate protections. If this is not possible, install an isolation transformer with the shield connected to ground. 2

Cautions with the connection Before applying the supply voltage or the signals, be sure that the wiring is correct. In the current analog inputs, check that the polarity is the right one and the shunt is present. If it is internal, by means of the proper jumper and if it is external, checking that the shunt resistance (3,74 ohm) is connected to the right terminals. In the Pt 100 inputs, checking the third wire will avoid saturated indications. In the inputs for mv and termopar, beside to the polarity is important to assure that the internal shunt of that channel is not selected. Every voltage between terminals higher than 3 V, from the same channel or between different channels, may cause damages in the equipment. It is always recommended to use twisted wire cable with shield for the signal lines and to use different pipelines than the ones for power or control. For a right shielding, connect it to a good quality ground (instrumentation ground) in only one of the sides. Do never connect to ground both sides of the shield. Avoid, as far as possible, the electrical ground where the circuit breakers, motors and power units are connected to. Usually, due to the deficient quality of these type of grounds, they are a source of electrical disturbances. It is recommended to use 1 mm 2 cooper cable for the signals to be measured. The connection of the communications must be exclusively done with twisted and shielded cable. Inputs connection Internal jumper S1 in position 2-3 (page. 7) Internal jumper S1 en posición 1-2 (page 7) 3

Descripcion of the front screen Measure TAG Status of the digital outputs Status of the digital inputs Keyboard At any place, returns to the preceeding menu. Advance to the next step. Data validation. Increases value Error messages Check probe and connections Measure is over the high limit or 9999 Measure is over then low limit or -1999 Decreases value Main menu Starting screen Alarm 1 setting Alarm 2 setting Alarm 3 setting Menú configuración Desde cualquier pantalla del menú regresa a la pantalla de inicio Pantalla inicial Hasta que cambie el menú Configuración Entrada Analógica Configuración Alarmas Configuración Comunicaciones Configuración Salida Analógica (opcional) 4

Configuration of the analog input Defines type of input Type Termopar Indication physical units Noise filter Reading correction Text editor of lower line of main screen -Type B -Type R -Type S -Type N -Type E -Type K -Type S -Type T No linealization Peaks filter 0-15 Average filter 0-9 Advance letter Number of decimals Minimum limit Maximum limit Linealización -No decimal -1 decimal -2 decimals -3 decimals Linealization editor Linealization editor PXX - Indication of the linealization point being edited Select the linealization point from 1 to 20. When point 0 is selected, the linealization editor is exited. Measure reading before to linealizate in the edited point. Measure reading after to linealizate in the edited point. Repeat this process for all the required linealization points. Configuration of the alarms (AL1, Al 2, AL3) Function output Relay contact Hysteresis of the alarm - Non active alarm - Normally opened - Maximum alarm - Normally closed - Maximum alarm - Window alarm - Regulation T/N low reverse (heat) - Regulation T/N high direct (cold) - Regulation T/N symmetric reverse (heat) - Regulation T/N symmetric direct (cold) 5

Configuration of the communications Communication speed Modbus address Modbus speed Communication test - 38400 bps - 19200 bps - 9600 bps No communication Addresses of the communications - High speed - Standard - Low speed - No Rx and Tx - Receive messages not for him - Answer - Receive message with CRC error - Receive message with wrong command Configuration of the analog output (optional) Type of output Output minimum limit Output maximum limit Output measured in error - No output - 0-20 ma - 4-20 ma When the measure shows Err, this value is generated Communications The communications channel operates with RS485 wiring. Protocol is ModBus RTU. Example of connection Connection of a network of devices to a PC using RS485. Conversion options PC Connector Sub-D 9 pins Female 6

Modification of internal jumpers The housing must be opened in the case that the jumpers default setting wants to be changed. By pressing the two nails at each side of the housing, the cover can be removed. EVERY TIME THAT THE HOUSING MUST BE OPENED, BE SURE THAT THE EQUIPMENT BE WITHOUT VOLTAGE IN ALL THE TERMINALS. Each analog input has a two positions jumper that allows to choose between the general input and the input of ma with internal shunt. Once the jumper is set in the desired position, use the configuration program to select the input type. Jumper in 2-3* Pt 100, PTC, mv, V, TP, 0-4...20 ma (without internal shunt) Jumper in 1-2 0-4...20 ma (with internal shunt) * Default position is 2-3 7

- Number of inputs:... 1 input - Types:... PTC, TP, RTD, mv, V, ma - Impedance:... >1 MΩ (mv) &... internal shunt 3,75 Ω 1% 25 ppm (ma) - Range CJC:... 0 a 50 C (internal sensor) - Standards for signals:... IEC584 (TP)... and IEC751 (Pt 100) - Termopar... J, K, R, S, T, E, N, B - Pt 100... -200/600 C - PTC... -50/150 C - Voltage:... ±75 mv & ± 2 VDC - Current:... 0..4-20 ma - Linealizatión:... 20 steps - Precision at 25 C:... ± 0,1% - Sampling time:... 125 ms (1 ch.)... 250 ms (2 ch.) Logical inputs (option): - Logical inputs... 3 x 220 VAC/DC... (24 VAC/DC in option) - Current consumption:... 2 ma máx. Analog outputs (option): - Quantity:... 1 or 2, common ground - Type:... ma (V with external shunt) - Resolution:... 13 bits - Output ranges:... 0..4-20 ma - Precision at 25 C:... ± 0,2 % - Refresh time:... 250 ms - Isolation:... 500 V - Maximum load:... 500 Ω Technical characteristics Digitals outputs: - Relays SPST NA... 3 x a 250 VAC/1A - Isolation... 500 V Output auxiliary voltage: - Output 1:... 18 VDC no stabilised - Maximum output current:... 50 ma - Isolation... 500 V - Output 2 (opt.):... 5 VDC stabilised (opt.) - Maximum output current:... 20 ma - Isolation... 500 V... (except with analog output) Communications: - Type:... RS-485 - Protocol:... Modbus RTU - Speed:... 9600, 19200, 38400 bauds Operation limits: - Ambient temperature:... 0 a 50 C - Storage temperature:... -20 a 70 C - Relative humidity:... máx. 85 HR%... (without condensation) Directive CE: - Emmision/Inmunity: EN 50081/EN 61000 Supply and consumption: - Voltage:... 60..250 VAC & 22..250 VDC... 20..60 VAC (option) - Frequency:... 50..60 Hz - Consumption:... 2 VA Basic Modbus addresses CONCEPT DATA TYPE MODBUS REGISTER LIMITS MODE MEASURE (AI1) Word with sign 30011 Only Read ALARM SET 1 (AL 1) Word with sign 40035-32767/32768 Read/Write HYSTERESIS ALARM 1 (AL 1) Word with sign 40036-32767/32768 Read/Write ALARM SET 2 (AL 2) Word with sign 40038-32767/32768 Read/Write HYSTERESIS ALARM 2 (AL 2) Word with sign 40039-32767/32768 Read/Write ALARM SET 3 (AL 3) Word with sign 40041-32767/32768 Read/Write HYSTERESIS ALARM 3 (AL 3) Word with sign 40042-32767/32768 Read/Write READ STATUS ALARM 1 (AL 1) Bit 30001 BIT 9 (30001.9) 0 OFF/1 ON Only Read READ STATUS ALARM 2 (AL 2) Bit 30001 BIT 10 (30001.10) 0 OFF/1 ON Only Read READ STATUS ALARM 3 (AL 3) Bit 30001 BIT 11 (30001.11) 0 OFF/1 ON Only Read READ STATUS OUTPUT 1 (DO 1) Bit 30002 BIT 2 (30002.2) 0 OFF/1 ON Only Read READ STATUS OUTPUT 2 (DO 2) Bit 30002 BIT 3 (30002.3) 0 OFF/1 ON Only Read READ STATUS OUTPUT 3 (DO 3) Bit 30002 BIT 4 (30002.4) 0 OFF/1 ON Only Read WRITE STATUS OUTPUT 1 (DO 1) remote mode Bit 40095 BIT 0 (40095.0) 0 OFF/1 ON Read/Write WRITE STATUS OUTPUT 2 (DO 2) remote mode Bit 40095 BIT 1 (40095.1) 0 OFF/1 ON Read/Write WRITE STATUS OUTPUT 3 (DO 2) remote mode Bit 40095 BIT 2 (40095.2) 0 OFF/1 ON Read/Write STATUS DIGITAL INPUT 1 (DI 1) Bit 30001 BIT 5 (30001.5) 0 OFF/1 ON Only Read STATUS DIGITAL INPUT 2 (DI 2) Bit 30001 BIT 6 (30001.6) 0 OFF/1 ON Only Read STATUS DIGITAL INPUT 3 (DI 3) Bit 30001 BIT 7 (30001.7) 0 OFF/1 ON Only Read The Modbus registers with format 300xx are reading adresses. They belong the the command 3 Modbus which allow a reading up to a maximum of 9 Modbusregisters per reading. The Modbus registers with format 400xx are reading/writing adresses. They belong the the command 16 Modbus which allow a reading up to a maximum of 3 Modbus registers per reading. The Modbus registers are showed in decimal. DISIBEINT reserves the right to alter this document wiwhout previous notice. Segle XX, 91 E08032-Barcelona T: +34 934 330 370 F: +34 934 354 532 www.disibeint.com disibeint@disibeint.com 8

Segle XX, 91 E08032 - Barcelona T: +34 934 560 995 F: +34 934 354 532 www.disibeint.com disibeint@disibeint.com