Carbon Monoxide (CO) Gas Detection and Control System

Similar documents
Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System

Multi-Point Digital Gas Detection and Control System

Sensor for car parks and tunnels

CDD Carbon Dioxide Transmitter

Gas Controller System DGC-06

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Series Room CO2 Transmitter Installation Instructions

Trident and Trident X2 Digital Process and Temperature Panel Meter

Carbon Monoxide Sensor - ModBus

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

AirTest Model CN9000 Series Sensor Controller

TOXALERT MODEL AIR 2000

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

User Manual. PolyGard NH 3 AT-1120/25. Electrochemical analog ammonia transmitters serial no. AT July 23, 2007

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

Dräger Polytron 8200 Stationary gas detector (CatEx)

TPE 1464 Series Pressure Transducer

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Andover ContinuumTM Infinet II

LOCAL DISPLAY UNIT (LDU)

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Zone Pressure Touch Sensor - Standard Range

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Tempco Instruction Manual

Zone Pressure Touch (ZPT) Sensor - Standard Range

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

AIR QUALITY/ GAS DETECTION

PanelView Plus/VersaView CE Terminals and Display Modules

Level-Lance Model 5400A

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Compact Coded Magnetic Safety Interlock Switch and Control Units

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Product Manual SZ2144

Carbon Dioxide Monitor/Controller With The USB Data Logger

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Semi flush-mounted room temperature controllers with LCD

MOD-RI Room Interface Modules with Modbus

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

High Voltage DC Meter

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

User Manual. PolyGard AT Electrochemical Nitrogen Oxide Transmitter Serial No. AT October, 2011

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

GG-6 MULTI-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

HIGH-VOLTAGE DC METER

Field selectable application type and room module series, via dip-switches on controller

FX Input/Output (I/O) Modules XM07 and XM14

DTM Distributed Transmitter Monitor

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

Inform IT Single Pen Circular Chart Recorder

Installation and User Guide

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

FX06 Field Controller

SP6R Level Controller Operation Manual

dual-line 6-dIGIt process MeteR

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Signet Pressure Transmitter

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Analog Voltage Combination Module

PD765 TRIDENT. Trident Series Process & Temperature Meters.

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Fast Route to Reliable Energy Savings ZIP Economizer

Temperature Controller E5C4

FLOW MONITOR & TRANSMITTER

TAC I/NETTM 1284, 1280, Security Control Unit

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Safety Temperature Limiter TT-STL 50

* Optional TLPC shown. Mounting for Square Pole ORDERING INFORMATION 72W 108W 141W 188W 108LED 141LED 188LED. DM 0-10V Dimming. (Std.

LCI User Manual mantracourt.com

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

Andover ContinuumTM. b3850 Series Terminal Controllers

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

DS Type: MAXIM III Controller

SP SP-T-9

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

LAUREL ELECTRONICS, INC.

Andover ContinuumTM Infinet II

EMS467 Monitoring System. Installation and Operations Manual Section 40

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Custom Controller Installation Instructions

Carbon Monoxide Transmitter

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Safety Monitoring Relays

Transcription:

Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature or humidity sensors. PolyGard SPC2-0 APPLICATION To detect and control levels of carbon monoxide (CO) and other gases in a wide variety of commercial and industrial applications such as vehicle exhaust in parking structures, engine repair shops, equipment rooms and ventilation systems, etc. The controller can interface via binary outputs and up to (2) signals with any compatible electronic analog control, DDC/PLC control or automation system. FEATURES Continuous monitoring One () built-in CO electrochemical sensor, gas specific, long life Easy plug-in sensor Three (3) remote analog inputs, Five (5) relay outputs: - Five-stage control - Fail-safe assignable Two (2) analog outputs, - Selectable for low, high or averaging Liquid Crystal Display (LCD) LED status indicators Accepts combination of toxic or combustible gases, refrigerants, temperature or humidity remote sensor inputs Built-in horn Keypad user interface Simple menu-driven programming RFI/EMI protected Modular technology Overload & short-circuit protected NEMA 4X enclosure Easy maintenance City of Los Angeles Approved NRTL Performance Tested & Certified Conforms to STD UL 2075 / UL 207 SPECIFICATIONS Electric Power supply 24 VAC/VDC, -5%/+20%, 50/60 Hz, auto-resettable fuse Power consumption 3 VA (0.5 A), w/max sensor connections RF/EMI protected 4.0 W @ 3 ft. ( m) radiated Sensor Performance Gas detected Carbon monoxide (CO) Sensor element Electrochemical, diffusion Range Span field adjustable from 0-200 to 0-300 ppm via calibration, 0-250 ppm factory set Stability & resolution ± 0.5 ppm of reading Repeatability ± % of reading Long term output drift < 0.4% signal loss/month Response time t90 < 30 sec. Sensor life expectancy 5 plus years, normal operating environment Sensor coverage 5,000 sq.ft., max. 0,000 sq.ft. (465 m 2, max. 930 m 2 ), under ideal conditions Installation Location Mounting height 5 to 6 ft. (.5 to.8 m) above floor Type of Control General Analog inputs Analog reading Stage level / setpoint - hysteresis/ switching differential Digital inputs Five-stage (S to S5) control, assignable up to five (5) binary/ relay output, i.e. Low-med-high-fault/fail-horn*, or low-low2-med-med2-high, or any other combinations (* = horn/audible alarm built-in and factory pre-configured to relay output R05 ) Three (3), for additional remote sensors Current and mean (average) value Field adjustable over full range, five (5) per analog input, assignable to current or mean (average) value Selectable for each sensor point Four (4), each can be individually assigned to any relay (R...R5). Digital inputs are used for remote audio/visual alarm reset Page of 5 Printed in USA 0052

SPECIFICATION Type of Control (Cont...) Relay outputs (R-R5) w/ status LEDs Five (5) SPDT, 8A 24 VAC/VDC-250 VAC contact resistance 00 m, max. - each stage level (S-S5) Assignable to any relay - sensor fail-safe Assignable to any stage level Time delay switching Selectable for make and brake of each sensor point (SP to SP4) 0-9,999 seconds Analog output Two (2) independent signal, 500 max. load, selectable as low, high or averaging of sensor inputs Audible alarm 85 db (0 ft), enabled or disabled, selectable; assignable to stage level S, S2, S3, S4 or S5 acknowledgement Menu-driven and system reset function for latched relays User Interface Keypad type Refer to illustration keypad user interface Touch buttons Six (6) Status LED s Red: Yellow: (fail) Digital display Liquid Crystal Display (LCD), two lines, 6 characters per line, digit resolution, backlit - unit display Menu selectable, per sensor; ppm, %v/v, %LEL, F or % RH Environmental Permissible ambient - working temperature 23 F to 04 F (-5 C to 40 C) - storage temperature 23 F to 86 F (-5 C to 30 C) - humidity 5 to 95% RH, non-condensing - working pressure Atmospheric ± 0% Physical Enclosure (panel) - material Polycarbonate, impact resistance EN 5002/IK08, flammability rating UL 94-5V - conformity UL Type, UL 508/UL 50 standards - color Light gray, smoked gray for cover - protection NEMA 4X (IP 65) - installation Wall (surface) mounted Dimensions (H x W x D) - base 7.9 x 7.5 x 4. in. (200 x 90 x 05 mm) Cable entry 5 holes for /2 in. conduit, covered Wire connection Terminal blocks, Push-on connect and screw type for lead wire Wire size - input Min. 22 AWG (0.34 mm 2 ) Max. 6 AWG (.50 mm 2 ) - output Min. 24 AWG (0.25 mm 2 ) Max. 4 AWG (2.50 mm 2 ) Weight 4.5 lbs. (2.0 kg) Approvals / Listings System NRTL Performance Tested & Certified: - sensor/transmitter Conforms to STD ANSI/UL 2075 - controller Conforms to STD ANSI/UL 207 - transmitter & controller City of Los Angeles CE VDI 2053, C-No. 4879 EMV-Compliance 89/336/EWG - enclosure (panel) UL Listed, E75645 Warranty Two years material and workmanship ORDERING INFORMATION SPC2-0 - 0 00 US Standard control system, ordering part number: SPC2-0 - 000 US, configuration includes: 0 Options No options Key lock w/2 keys 00 0-99 Trip/Setpoints Factory set (built-in sensor): Low alarm @ 25 ppm CO ( R ), High alarm @ 00 ppm CO ( R2 ), Horn alarm @ 00 ppm CO ( R5 ) Special on request Digital, programmable controller with menu-driven keypad user interface, LCD & LEDs, 24 VAC/VDC, 50/60 Hz NEMA 4X enclosure Built-in: () CO sensor/transmitter () Horn, audible alarm Inputs: (3), for remote sensors (4) Digital Outputs: (5) Relays, SPDT, 8 A (2) Page 2 of 5 Printed in USA 0052

USER INTERFACE & CONTROLLER Keypad User Interface Yellow LED Flashes at system / sensor failed Red LED Flashes when any stage level setpoint is exceeded; steady when any relay output is in manual override operation Scroll down & up in Main menu and Sub menus; increases or decreases a value Navigates through menus on the same level; moves cursor when inputing data Exits programming and saves settings or return to previous level or menu Enter Sub menus or stores data; horn silence (if assigned) Main Page & Main Menu 0.24.05 :45 am System Errors Stage Status Relay Status Sensor Readings Relay Setup SP Setup System Setup 0. 24. 05 :45 am System Operation All Programming is made via the keypad user interface in combination with the display screen. Security is provided via two password levels. The lower level password allows to override or to reset system status functions. The upper level password allows all programming and override functions. Main Page Display Displays date and time, unless a system error occurs, then the error is displayed. Main Menu Displays headings of System Errors, Stage Status Relay Status, Sensor Readings, Relay Setup, SP (Sensor Point) Setup, and System Setup. Sub Menu System Errors Displays errors, reset corrected errors, and historical error summary. Sub Menu Stage Status Displays status of each SP sensor point, stage level/ setpoint exceeded. Sub Menu Relay Status Displays status and manual control of each output relay. Sub Menu Sensor Readings The current and mean/average values are displayed for each SP sensor point with sensing type and engineering unit (ppm, %v/v, %LEL, F, %RH). Sub Menu Relay Setup Enter and /or change parameters of each relay. - Assign de-energized or energized normal operation - Select steady or flashing function - Select horn function - Select latching or non-latching mode - Select digital input usage, and assign to any output relay Sub Menu SP Setup Enter and/or change parameters of each sensor point. - Activate sensor point - Select sensor point type (gas, temperature, humidity) - Select measuring range - Select sensor signal - Select stage/setpoint to 5 - Select hysteresis - Set delay ON/OFF time - Select current or mean/average value - Assign sensor point fault to stage level setpoint - Assign setpoint to 5 to any output relay - Assign to analog Output Sub Menu System Setup Enter and/or change system parameters. - Select service mode - Set next maintenance date - Select service phone number - Select averaging function, time and overlay, of any SP - Set date, time and time format - Change customer password - Select analog output function - Set failure relay - Select power ON time - Select apporpriate hardware configuration Page 3 of 5 Printed in USA 0052

FIELD WIRING CONFIGURATION 24 VAC/VDC Input Power 2 (see ill. ) (see ill. 2) X Binary - Relay Outputs R0 R02 R03 R04 R05 2 2 3 4 5 6 7 8 9 0 2 3 4 5 0.24.05 0: 28am X0 X2 X 234567 8 9 02 2345678902 DIN Rail Recommended Twisted, shielded wire for analog inputs (Shield to be terminated and connected only at the sensor/transmitter location) Grounded housing Caution: The non-metallic enclosure does not provide grounding between conduit connections. Use grounding bushings and jumper wires. The enclosure is to be mounted using the mounting holes located in the base external to the equipment cavity, or the equivalent. The conduit hubs must be connected to the conduit before connected to the enclosure. (see ill. 3) Sensor Inputs Digital Inputs Analog Outputs When connecting conduit to the enclosure use only UL listed or UL recognized conduit hubs that have the same environmental type rating as the SPC2 enclosure. (see ill. 4) (see ill. 5) Horn Sensor/Transmitter 24 VAC/VDC Input Power Supply (+) Com 24 VAC/VDC, -5%/+20%, 50/60 Hz 2 Min wire size 6 AWG (.5 mm 2 ) Terminal block X ill. Page 4 of 5 Printed in USA 0052

FIELD WIRING CONFIGURATION (cont...) Binary - Relay Outputs R0 to R05 Built-in horn alarming*** factory wired, (fail) alarming Stage-level control & alarming ( ) (+) *** #3 #2 # H 2 3 4 5 6 7 8 9 0 2 3 4 5 X2 *** Factory pre-configured horn and fault (fail-safe), can be reassigned/converted for remote control, stage-level #4 and/or #5 R0 R02 R03 R04 R05 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) ill. 2 Digital Inputs DI0 to DI04 2 3 4 5 6 X Analog Outputs AO0 and AO02 7 8 9 X (AO02) Com (AO0) signal to remote control or BAS, selectable low, high or averaging of (4) analog (sensor) inputs, 500 max. load The current signal is sourced by the SPC2 system ill. 4 ill. 5 Remote Sensor Inputs SP02 to SP04 SP0/02- ( ) SP02 SP03 SP03/04- ( ) SP04 Built-in Sensor SP0 4 2-wire sensor / transmitter 2 3 4 5 6 7 8 9 0 ill. 3 3-wire sensor / transmitter ( ) X0 Page 5 of 5 Printed in USA 0052