Training Offer. Catalogue

Similar documents
Nexans Visio Template 2.1

ISO/IEC 11801: (E)

Advanced Fiber Optic Connector Installation

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

LANmark p h y s i c a l i n f r a s t r u c t u r e s o l u t i o n s s e c u r e y o u r i n f o r m a t i o n f l o w

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

The AMP NETCONNECT Category 6 Cabling System

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

Fiber Optic and CAT 5-6 Installer Premise Cabling

Copper Cabling Standards

MOLEX PREMISE NETWORKS

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

Optical Fiber for Today s Premises Applications

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

CommercialNetworking: Training

Application Note. Data Center Standards and Layouts

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

ISO/IEC TR Guidance on 40GBASE-T T Cabling

Chapter 4: Network Access. Introduction to Networks v5.1

Appendix 1 to the R&Mfreenet Warranty Program

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

The AMP NETCONNECT Category 6 Cabling System

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

INTERNATIONAL STANDARD

FTTE Revisited for New Technologies

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1

ANSI/TIA/EIA-568-B Cabling Standard

Tarleton State University. Specifications

Corrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises

Increase Network Reliability and Reduce Costs with Cabling Management Software and Services Designed Especially for SYSTIMAX Installations

BACKBONE CABLING. Structured Cabling Systems. Entrance Closet. Telco Closet. Intermediate Cross Connect. Telco Closet. Main Cross Connect.

Cabling Solutions Data Center & Local Area Networks

THE NEW OPTICAL FIBRE CATEGORIES What do they promise?

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant

Cabling Infrastructure

PROFIBUS Course Document Certified PROFIBUS Installer Course CPI Version 1.1 June 2011 Order No: PROFIBUS Learning Outcomes, Order No: 4.

UTP Cat 5e cable (200 MHz) (PVC sheath)

Fiber Management Systems

City & Guilds

The following pages contain a guide for the installation

Certification for 10G copper cabling

Uniprise Structured Cabling Solutions Guide

WORLDSKILLS STANDARD SPECIFICATION

AS/NZS 3080:2003 AS/NZS

Fiber Backbone Cabling in Buildings

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

Customer Training Catalog Training Programs Outside Plant

Using Low DMD, Laser Optimized Multimode Fiber to Expand 10-Gigabit Network Design Options

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters

Fiber Optic Technician - Outside Plant (FOT-OSP) Course Description. Certification(s) Students Will Learn. Splicing Overview & Testing Outside Plant

Total Amount Carried Forward To Bill summary Page

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

ANSI/TIA-568-C Cat 6A Field Test Specifications

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

Fiber backbone cabling in buildings

ANSI/TIA/EIA-568-B Cabling Standard

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

Hands-On Fiber Optic Designer

Qualified Partner Programme QPP. Fiber Optic Gigabit Ethernet Theory Felice Guarna

Qualified Partner Programme QPP. Warranty Felice Guarna

Standards Update. by Paul Kish NORDX/CDT

White Paper: Choosing the RIght OTDR for your Datacenter

Product Guide. SYSTIMAX Structured Connectivity Solutions

HUBER+SUHNER DCCT Training

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

Optical Fiber Networks: Industry. and New Options for Networks

White Paper: Installing Data Networks Using LinkWare Live SaaS

Copper Certification Testing Best Practices Pocket Guide

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

TO THE BID PACKAGE FOR COUNTY OF INYO NETWORK PROJECT. This addendum is being issued to modify portions of the Bid Package for the Project entitled:

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture

Trends in Data Centre

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

Capabilities Statement W. Catawba Ave Cornelius NC (704) Phone (800) Fax

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

UNIVERSITY OF CALICUT (Purchase Division)

Multimode Measurement Cords Recommendations for Multimode Link Field Certification

MT-RJ OPTICAL FIBER SYSTEMS TESTING. Field Testing Made Easy

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S

LAN CABLING SYSTEMS 2018

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

Factory assembled FO cabling system with LC-Duplex adapter-interfaces in PURE quality, GHMT channel certified

LANmark-6 10G LANmark-6 A

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

CONNECTING THE WORLD TO A HIGHER STANDARD.

FIBER OPTIC HARDWARE STEVE PAULOV

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

Simplify Fiber Optic Cabling Migrations with a Multi-Path System

a. Common Data Cabling 1) Structured cabling network - Schematic Diagram

BGP Support for Ipv6. Switch should have virtualization feature as one or more switch can act as a single Switch or equivalent IP clustering

City & Guild (102/103) Learn to Install & Test Fibre Optic Cable. Introductory Guide. Centre. Training Academy

The six major components of a structured wiring system are:

AMP NETCONNECT XG FIBER SYSTEM

Transcription:

Training Offer Catalogue

docnr. 3.0 rev.date: 04 August 2008 2/13

Introduction, "The transmission quality of a cabling installation depends on the cabling system used, as well as the installation itself." Nexans Cabling Solutions has elaborated its training program. Trainings are given at the Competence Centre in Brussels, as well as on demand at your premises worldwide or in our Local Training centres in different regions. No matter what your level is, we'll find the best training program meeting all of your needs. The LAN technology evolution requires a wide and varied range of skills. No two projects are the same and our partner's position is important in this business. The aim is to find the synergy between your needs and our training program. In order to make this "level training" program possible, the trainings have been divided into different modules which are all addressing different topics aimed at different people. Installers Project Managers Designers, Consultants and Architects Commercial Staff that would like to improve their sales techniques End Users Anybody involved in cabling that would like to improve his knowledge and skills in this domain. Trainees can obtain a "Nexans Cabling Solutions Supervisor certification" when they succeed in the 3-day Expert training. It is clear that a new VAR, Distributor, or Certified Solutions Partner will be required to succeed in the Expert training. If the new partner has no experience it is recommended that he will first attend the full Expert training. If the partner has previous experience, he can follow a tailored Expert training. docnr. 3.0 rev.date: 04 August 2008 3/13

Training Modules Overview Commercial Module 3 Nexans Copper Cabling Solutions * 6 Module 8 Nexans Optical Fibre Cabling Solutions * 8 Expert Knowledge Module1 Premises Cabling Standards * 5 Module 2 Parameters for Copper Cabling * 5 Module 4 Installation Rules and Guidelines * 6 Module 7 Optical Fibre Theory and Principles * 8 Module 12 Design Training: Project Study 10 Module 14 Design Training: Project Engineering 12 Module 15 Design Training: Project Tendering 13 Module 16 Project Management 13 Hands-on Module 5 Installation Practice & Testing Class D-E-EA Links * 6 Module 6 Installation Practice & Testing Class F-FA Links 6 Module 9 Fibre Installation Practice with Direct Termination * 9 Module 10 Fibre Installation Practice on Fusion Splicing 9 Module 11 Testing Optical Fibre Links * 10 Module 13 Nexans Easy Design Visio Software 11 * Modules part of the 3 Day Expert Training Program To apply for a training, please contact your local Nexans sales representative or alain.geypens@nexans.com. docnr. 3.0 rev.date: 04 August 2008 4/13

Training modules 1 Premises Cabling Standards* Introduction to Data Cabling Universal Cabling: Concept and evolution Standardization: - Comparison of the different norms - What, Why, impact on cabling - ISO/IEC 11801, Cenelec 50173, EIA/TIA 568-A/B - Categories versus Class performances - Configuration model - Evolution Horizontal channel design: - 2, 3 and 4 connector channels - Length calculation of a channel Horizontal & Vertical Signal routing: - Voice Signal routing for Analog, Digital or VoIP - Data Signal routing Copper and Fibre - Entrance facilities Time required: 4:00h Prerequisites: none Understand requirements and philosophy of the Premises Cabling System Standards Identify components in a structured cabling system Identify vertical and horizontal routing of data and voice signals. Calculate maximum distances for horizontal channels Define requirements for a Structured Cabling System on Campus, Riser and Horizontal links. 2 Parameters for Copper Cabling* Technical Parameters Megabits versus Megahertz Data applications: Ethernet, Token Ring, Fast Ethernet, ATM, Gigabit Ethernet, Encoding systems IL, NEXT, ACR-N PS specs, FEXT, ACR-F, RL, NVP, Delay Skew Alien crosstalk parameters, SNR Coupling attenuation Their influence on cabling installation practices Analyse Test results Identify errors in a copper link Create high performance copper links Time required: 2:00h Prerequisites: Knowledge of Standards on Copper Cabling docnr. 3.0 rev.date: 04 August 2008 5/13

3 Nexans Copper Cabling Solutions* E-ssential range Why Systems? LANmark 5, 6, 6a and 7(a) Systems GG45 Cat-7, Cat-7a When and how to use each Cabling System Class? The Nexans Warranty Programm Voice range Structural Hardware Cabinets Services Identify each component in the copper product range Select a Cabling System according to the end-users needs Discover unique features of the Nexans Cabling System Products Be more competitive in the market Time required: 2:00h Prerequisites: Knowledge of Standards on Copper Cabling 4 Installation Rules and Guidelines* Indoor cabling Outdoor cabling Fire restrictions Numbering and labelling Cabinet location Earthing and Grounding - Safety versus EMC - Requirements for correct Earthing and Grounding Administration and documentation - Master cable schedule - Floor distributor Cable schedule - Building cabling plans - Cabinet Layout - Nexans Visio Templates Acquire basics on installation practices Apply installation rules and guidelines during design Create professional administration documents Understand requirements from Standards on installation practices Increase performance in a cabling system Time required: 2:30h Prerequisites: Knowledge of Standards on Copper Cabling docnr. 3.0 rev.date: 04 August 2008 6/13

5 Installation Practice & Testing Class D-E-EA Links* Termination of UTP, F 1 TP, F²TP, S-FTP, STP copper cables How to build high performance Class D, Class E and Class Ea Links Installation practices for 2, 3 & 4 Connector links LANmark-5 screened and unscreened: - PCB termination - EVO termination LANmark-6 screened an unscreened: - Snap-in termination Earthing and Gounding Testing: - Using Certified Level III (Cat 6) testers - Testing 2, 3 and 4 connector links - Calibration, Firmware, Testing limits - Analyses of the test results - Troubleshooting Create high performance copper links Decrease installation times Testing Class D, E and Ea links according to the Standards Solve problems of failing links Time required: 4:00h Prerequisites: Knowledge of Cabling Installation Rules and Copper Cabling Parameters 6 Installation Practice & Testing Class F-FA Links Termination of LANmark-7 & 7A STP copper cables GG45 termination practice Easy termination tool 2, 3 & 4 Connector links Testing: Using Certified Level IV (Cat 7) testers Testing 2, 3 and 4 connector links Calibration, Firmware, Testing limits Analyses of the test results Troubleshooting Create high performance copper links Decrease installation times Test Class F and FA links according to the Standards Solve problems of failing links Time required: 4:00h Prerequisites: Knowledge of Cabling Installation Rules and Copper Cabling Parameters docnr. 3.0 rev.date: 04 August 2008 7/13

7 Optical Fibre Theory and Principles* Theoretical Introduction Fiber Construction, Fiber types Optical windows, Refractive index Multimode versus Singlemode Step Index, Dispersion and Graded index Optical Transmitters: - LED, VCSEL, LASER - Launch conditions Transmission characteristics: - Attenuation - Bandwidth, dip, maximum link length Advantages of Optical Fiber Fibre Termination Identify Fibre types Consider Length restrictions during design Identify Components of an optical fibre link Define Optical Fibre cabling requirements Time required: 2:00h Prerequisites: none 8 Nexans Optical Fibre Cabling Solutions* LANmark-OF Fibre types Application to Length implication Cable constructions: - Outdoor - Indoor Modular patch panels, Snap-in Couplers Optical Fibre Termination products: - Splicing - Direct Connectorising Patch cords Fibre To The Desk Solutions Pre-terminated Fibre The Nexans Warranty Programm Identify each component in the Optical Fibre product range Select a Cabling System according to the end-users needs Discover unique features of the Nexans Cabling System Products Be more competitive in the market Time required: 2:00h Prerequisites: Knowledge of Standards on Optical Fibre Cabling docnr. 3.0 rev.date: 04 August 2008 8/13

9 Fibre Installation Practice on Direct Termination* Fibre Installation Practice Recommendations to maintain Duplex OF Channel Polarity Patchpanel & Zone Distributionbox: - Anaerobic Connectorisation - ST, SC, LC on 900µ Fibres - ST, SC, LC on 3mm Patchcable - Hotmelt connectorisation - ST, SC on 900µ Fibres - ST, SC on 3mm Patchcable Identify each component in the Optical Fibre link Maintain Duplex OF Channel Polarity Create high performance Fibre links Decrease installation times Troubleshoot Time required: 2:00h Prerequisites: Knowledge of Fibre Theory and Principles 10 Fibre Installation Practice on Fusion Splicing Fibre Installation Practice Recommendations to maintain Duplex OF Channel Polarity Fusion Splicing Methods Patchpanel & Zone Distributionbox: - Organisation of fibres in Splicetrays - Protecting splices: - Metallic - 250µ fibres - Heatshrink - 250µ & 900µ Fibres Identify each component in the Optical Fibre link Maintain Duplex OF Channel Polarity Create high performance Fibre links Decrease installation times Troubleshoot Time required: 2:00h Prerequisites: Knowledge of Fibre Theory and Principles docnr. 3.0 rev.date: 04 August 2008 9/13

11 Testing Optical Fibre Links* Parameters Causes of Attenuation Optical Budget calculation Optical Fibre Measurement Microscope Power Meter Types - Power meter principle - Setting Reference - Analysing results OTDR - Optical Time Domain Reflectometry principle - Dead zones - Connections and splices - Analysing results - Ghosting Time required: 4:00h Identify each component in the Optical Fibre link Test Opticle Fibre links according to the Standards Solve problems of failing links Certifiy Installations Prerequisites: Knowledge of Standards on Optical Fibre Cabling and Fibre Theory docnr. 3.0 rev.date: 04 August 2008 10/13

12 Design Training: Project Study Cabling System Concept Impact of the Active Equipment Horizontal & Vertical Signal Routing Interfaces with other systems Data Collection 2 ways: starting from scratch or from an Invitation To Tender (ITT) Level of performance - Telecom Outlets - Backbones - Interfaces Cabling System Design Backbone design - Voice, Data copper, Data OF Horizontal channel design - 2 connector link, Consolidation point, Lengths, Outlets Exercise Data collection from an Invitation To Tender (ITT) Design production Analysis and corrections Time required: 12:00h Identify each component in a Universal Cabling System Consolidate information from a tender Identify missing information in a tender Collect all information needed to design a Universal Cabling System Create professional drawings Prerequisites: none 13 Nexans Easy Design Visio Software Software installation Discovering the Using Interface Analyses of the tabs By means of exercise filling out the fields Launching the design tool Evaluating the created drawings Creating a Bill of Material Quickly adapt to the design tool Learn basics of Visio Create professional drawings Create a Bill of Material Time required: 4:00h Prerequisites: Knowledge of Standards on Copper and Fibre Cabling docnr. 3.0 rev.date: 04 August 2008 11/13

14 Design Training: Project Engineering Labeling Identifying Non-NCS components Scope of work - Cabling System Infrastructure - Existing or out of the Scope Of Work - Routing analysis - Presence of cables from other systems - Size check - Routing up to Cabling System components - Accessibility - Included in the Scope Of Work - Routing - Containment, Sizing, specific requirements - Earthing - Accessibility - Installation works - Cabling System products - Other works - Project Management Team - Transportation & Local costs - Subcontracting Engineering exercise Create Bill Of Quantities (BOQ) - Accessories - Interfaces with other systems - Non-NCS components Collect all information for before design Investigate building site and/or plans Specify Scope of Work Create a Bill of Quantities Time required: 12:00h Prerequisites: Knowledge of Standards on Copper and Fibre Cabling docnr. 3.0 rev.date: 04 August 2008 12/13

15 Design Training: Project Tendering Files to include in a tender - BOM BOQ using Nexans Easy Design - Pricing - Design drawings using Nexans Easy Design - Technical Description and Planning - NCS & N-NCS data sheets + general docs - Quality Safety - Specific Requirements Follow up and feedback - Tender follow up during the decision process Feedback if awarded: - First step: from Sales + decision makers - Second step: from Project Manager during installation phase Time required: 8:00h Create all documents for Tender Support Sales team on technical details Support team during implementation and to use feedback Prerequisites: Knowledge of Standards on Copper and Fibre Cabling and NED tool 16 Project Management Rules and advises Project preparation - Preliminary study of the dossier - Transfer meeting from Sales & Engineering to PM - Thorough analysis of the dossier and quotation - On site pre-installation survey - Material order and installation works planning On site quality management (Pictures illustrated) On site installation - Kick off - Installation - Testing and reception As-built files, financial results and invoicing Manage Project preparation Analyse documents and quotations Collect information during pre-installation site survey Plan Works and Support installation from beginning to end Time required: 8:00h Prerequisites: Knowledge of Standards on Copper and Fibre Cabling and Project Study, Engineering and Installation Rules and Guidelines docnr. 3.0 rev.date: 04 August 2008 13/13