THE NEXT TRANSDUCER GENERATION

Similar documents
POWER FOR THE CONTROL CABINET COMPACT INSTRUMENTS FOR MONITORING ALL ASPECTS OF POWER DISTRIBUTION

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

POWER MEASUREMENT IN ELECTRICAL SYSTEMS SIRAX MONITOR SERIES BUILT-IN DEVICES FOR MEASUREMENT IN POWER SYSTEMS

Multifunction Transducer MT440

SAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS

AVOIDING POWER QUALITY PROBLEMS

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

UNIVERSAL MEASURING UNIT FOR HEAVY CUR- RENT VARIABLES

MIC-2 MKII, Multi-instrument DATA SHEET

Voltage Transducer UMT516 / MT516

Rely on us. SINEAX CAM Universal measuring unit for heavy current variables

INDUSTRIAL MEASURING SOLUTIONS 2018/2019 MAIN CATALOGUE

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

CURRENT TRANSFORMER FOR THE SAFE MEASUREMENT OF CURRENTS SAFE FLEXIBLE EASY

AUTARKIC PROCESS MANAGEMENT

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

A2000 Multifunctional Power Meter

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

SUBJECT TO CHANGE WITHOUT NOTICE

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

with Backlight Graphic LCD Screen

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

SUBJECT TO CHANGE WITHOUT NOTICE

SIGNAL CONVERTER OF THE PREMIUM CLASS

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Operating Manual for UMD 701. Short version General Description 1

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

DATA SHEET Selectable AC transducer, TAS-331DG

VR660 / A200R Programmable Modular Controller System

Operating Manual for SMC 133. Short version 2.0. The complete and most actual version of this manual is available online at

Heavy Current Engineering

EngyVolt RV12 and RV15

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Energy Management Energy Transducer Type ET112

FOUR FUNCTIONS ONE SOLUTION

USER MANUAL 2012 V1.1

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

WM20. Power analyzer for three-phase systems. Benefits. Description

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Heavy Current Engineering

DATA SHEET Selectable AC transducer, TAS-321 DG

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Multichannel power analyzer for single, two and three-phase systems

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

CAM mobile. Device handbook. Operating Instructions CAM mobile 06/2014

Energy Management Solutions

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Smart Energy & Power Quality Solutions. UMG 103-CBM energy meter with memory COMPACT, BEST-PRICED & SAFETY

Digital Multifunction Meters. Digital Multifunction Meters

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

InteliPro. Protection Relay for Parallel Applications. Technical Specification

GPM500 Generator Protection Module

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

MID approval no. DE-08-MI004-PTB004 Date of release

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

EM6400 series Multi-Function meters

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

DIRIS N300/N600 Network analysers Network quality control and analysis system

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Mains Quality PQ-ANALYZER CLASS A

JUMO mtron T Measuring, Control, and Automation System

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

02/11/2015

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

KS5 SYNCHRONIZATION METER

DPT300 transducer range. Technical reference manual BGX R01

Energy Management Modular Energy meters Type EM2-96

AO561 Analog Output Module

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

INTEGRA DIGITAL METERING SYSTEMS

Neon pr. ph/ ORP measurement. Applications. Description

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

EM2020 Selectable AC transducer A (UK)

Power Meter PowerMonitor 500

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

ht20 EXAMPLE OF APPLICATION Ethernet www/ ftp / smtp Ethernet TCP IP Ethernet/ internal network 1

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

AI561 Analog Input Module

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Transcription:

THE NEXT TRANSDUCER GENERATION ADJUSTABLE HIGH-ACCURACY HEAVY-CURRENT SENSORS SINEAX DM5S/DM5F

Heavy-current sensor for grid monitoring. SINEAX DM5S and SINEAX DM5F are freeprogrammable universal measurement devices for heavy-current systems: Classical high-accuracy transducers, suited for monitoring tasks and retrofit applications in energy distribution and industry. The devices can be adapted fast and easily to the measurement task by means of the CB-Manager software even if there is no power supply available. Depending on the device version measured quantities can be mapped proportionally to analog DC current outputs or to Modbus.

DYNAMIC Response times starting at 15ms (for DM5F) Automatic scaling of measuring inputs possible Uninterrupted measurement of input variables ACCURATE 0.15% (U,I) and 0.2% (P,Q,S) Meter accuracy for active energy 0.5S (DM5S only) Adjustable meter resolution FLEXIBLE Scalable hardware approach (you only pay for what you need) Device function completely programmable Combinable Modbus image for optimised data retrieval USER-FRIENDLY Little space required in the control cabinet Programmable also without auxiliary energy Independently tested quality (UL listed)

DM5S/DM5F The measurement is done uninterrupted in all four quadrants and can be adapted optimally to the system to be monitored. Both the average time of the measurement and the expected maximum signal level can be configured. Commissioning is very easy and is supported by means of service functions, such as nameplate printing, connection check, measurement acquisition as well as simulation and trimming of the analog outputs. DEVICE VERSION SINEAX DM5S SINEAX DM5F Measurement time, programmable 4...1024 cycles ½, ½ (1), 2,4, 8 cycles Fastest response time (at 50Hz) 85...165 ms 15...25 ms Energy metering max. 32 meters not supported Auto-scaling V/I inputs supported not supported SYSTEM STATE MONITORING IN CLASS 0.2 These instantaneous values will be calculated in regular configurable intervals and provided to analog outputs and Modbus interface. DESCRIPTION 14 2L 3G 3U 3A 4U 4O System voltage Yes Yes Voltage L1-N Yes Yes Yes Voltage L2-N Yes Yes Yes Voltage L3-N Yes Yes Voltage L1-L2 Yes Yes Yes Yes Yes Voltage L2-L3 Yes Yes Yes Yes Yes Voltage L3-L1 Yes Yes Yes Yes Yes Zero displacement voltage Yes Yes System current Yes Yes Current in phase L1 Yes Yes Yes Yes Yes Current in phase L2 Yes Yes Yes Yes Yes Current in phase L3 Yes Yes Yes Yes Neutral current (calculated) Yes Yes Yes Active power of the system Yes Yes Yes Yes Yes Yes Yes Active power in phase L1 Yes Yes Yes Active power in phase L2 Yes Yes Yes Active power in phase L3 Yes Yes Reactive power of the system Yes Yes Yes Yes Yes Yes Yes Reactive power in phase L1 Yes Yes Yes Reactive power in phase L2 Yes Yes Yes Reactive power in phase L3 Yes Yes Apparent power of the system Yes Yes Yes Yes Yes Yes Yes Apparent power in phase L1 Yes Yes Yes Apparent power in phase L2 Yes Yes Yes Apparent power in phase L3 Yes Yes 14 = Single phase system or 4-wire balanced or 3-wire unbalanced phase shift 2L = two-phase system (split phase) 3G = 3-wire balanced DESCRIPTION 14 2L 3G 3U 3A 4U 4O System frequency Yes Yes Yes Yes Yes Yes Yes Active power factor of the system, PF=P / S Yes Yes Yes Yes Yes Yes Yes Active power factor in phase L1 Yes Yes Yes Active power factor in phase L2 Yes Yes Yes Active power factor in phase L3 Yes Yes Reactive power factor of the system, QF=Q / S Yes Yes Yes Yes Yes Yes Yes Reactive power factor in phase L1 Yes Yes Yes Reactive power factor in phase L2 Yes Yes Yes Reactive power factor in phase L3 Yes Yes LF factor of the system, sign(q) (1 abs(pf)) Yes Yes Yes Yes Yes Yes Yes LF factor in phase L1 Yes Yes Yes LF factor in phase L2 Yes Yes Yes LF factor in phase L3 Yes Yes Average voltage Yes Yes Yes Yes Yes Yes Yes Average current Yes Yes Yes Yes Yes Yes Yes Average current with sign of P Yes Yes Yes Yes Yes Yes Yes Bimetal current of the system Yes Yes Bimetal current in phase L1 Yes Yes Yes Yes Yes Bimetal current in phase L2 Yes Yes Yes Yes Yes Bimetal current in phase L3 Yes Yes Yes Yes Slave pointer of bimetal current of the system Yes Yes Slave pointer of bimetal current in phase L1 Yes Yes Yes Yes Yes Slave pointer of bimetal current in phase L2 Yes Yes Yes Yes Yes Slave pointer of bimetal current in phase L3 Yes Yes Yes Yes 3U = 3-wire unbalanced 3A = 3-wire unbalanced in Aron connection 4U = 4-wire unbalanced 4O = 4-wire unbalanced in Open-Y connection

DM5S: ENERGY CONSUMPTION MONITORING IN CLASS 0.5S The DM5S supports up to 32 energy meters. To each of these meters a base measurement quantity and a tariff can be assigned. The present tariff is set via Modbus. For application with short measurement times, e.g. energy consumption for a single working day or production lot, the resolution can be adapted. Thanks to uninterrupted measurement and automatic range detection a high accuracy is achieved. Up to 32 meters Up to 16 tariffs (control via Modbus) Free selectable base quantity (P, Q, S, I) High accuracy 0.5S Uninterrupted measurement Free selectable meter resolution FREE DEVICE ASSEMBLY For parameterization the DM5 is equipped with a USB interface as a standard. The measurement output can be performed via analog outputs and / or a Modbus interface. For the designation of the device the marking of the Power LED can be overwritten with the device description. The associated label can then be printed. DM5X- 70.5 APPLICATION Universal version (for all system types) Balanced systems Single-phase systems and 4-wire balanced 110 ANALOGUE OUTPUTS Without 1,2,3 or 4 galvanically isolated ±20mA MODBUS INTERFACE (MODBUS/RTU PROTOCOL) Without With 70 PARAMETERIZATION, SERVICE AND MEASUREMENT ACQUISITION The CB-Manager software provides the following functions to the user: Full parameterization of DM5S/DM5F Locally: Via USB interface (even without power supply) Remote: Via Modbus interface OFFLINE: No device connected Data label printing of present parameterization Free selectable LED marking Acquisition and recording of measured quantities Check of proper device connection Archiving of configuration and measurement files Setting or resetting of meter contents Simulation and trimming of analog outputs Comprehensive parameterization help A security system can be activated to restrict the access to device data.

TECHNICAL DATA INPUTS via screw terminals 6 mm 2 Nominal current: adjustable 1...5 A Maximum: 7.5 A (sinusoidal) Consumption: I2 x 0.01 Ω per phase Overload capability: 10 A continuous 100 A, 10 x 1 s, interval 100 s Nominal voltage: Maximum: Consumption: Impedance: Overload capability: Nominal frequency: Measurement TRMS: TYPES OF CONNECTION 57.7 400 V LN, 100...693 V LL 480 V LN, 832 V LL (sinusoidal) U2 / 1.54 MΩ per phase 1.54 MΩ per phase 480 V LN, 832 V LL continuous 600 V LN, 1040 V LL, 10 x 10 s, interval 10 s 800 V LN, 1386 VLL, 10 x 1 s, interval 10 s 45 50 / 60 65 Hz up to 31st harmonic Single phase Split phase (2 phase system) 3-wire, balanced load 3-wire, balanced load, phase shift (DM5S only) 3-wire, unbalanced load 3-wire, unbalanced load, Aron connection 4-wire, balanced load 4-wire, unbalanced load 4-wire, unbalanced load, Open-Y POWER SUPPLY via screw terminals 6 mm 2 Nominal voltage: 100 230 V AC ±15%, 50...400 Hz 24...230 V DC ±15% Consumption: 10 VA ANALOG OUTPUTS Linearization: Range: Uncertainty: Response time (50Hz): Burden: Burden influence: 0.1% Residual ripple: 0.2% via plug-in terminals 2.5 mm 2, galvanically isolated Linear or kinked ± 20 ma (24 ma max.), bipolar ± 0.1% (included in basic accuracy) DM5S: 85 165ms (for 4 cycles measurement) DM5F: 15 25ms (for ½ cycle measurement) 500 Ω (max. 10 V / 20 ma) MODBUS/RTU via plug-in terminals 2.5 mm 2 Physics: RS-485, max. 1200 m (4000 ft) Baud rate: 2.4 up to 115.2 kbaud Number of participants: 32 CONFIGURATION INTERFACE USB Physics: USB, max. 3 m Connection: Socket USB-B Device class: Human interface device (HID) MEASUREMENT UNCERTAINTY Reference conditions: Ambient 23 C ±1K, sinusoidal, PF=1, (acc. IEC/EN 60688) Frequency 50 60 Hz, burden 250 Ω, Measurement over 8 cycles (DM5S), 1 cycle (DM5F) 1) 2) Voltage, current: ± 0.15% FSU / FSI Power: ± 0.2% (FSU x FSI) 2) Power factor: ± 0.1 2) Frequency: ± 0.01 Hz Active energy: Class 0.5S, EN 62 053-22 (DM5S only) Reactive energy: Class 2, EN 62 053-23 (DM5S only) 1) FSU / FSI Configured maximum value of voltage / current inputs 2) Additional uncertainty if neutral wire not connected (3-wire connections) Voltage, power: 0.1% of measurement value; Load factor: 0.1 Energy: Voltage influence x 2, angle uncertainty x 2 SAFETY Current inputs are galvanically isolated from each other. Protection class: II (protective insulation, voltage inputs via protective impedance) Pollution degree: 2 Protection rating: IP30 (housing), IP20 (terminals) Overvoltage category: CAT III up to 600V AMBIENT CONDITIONS, GENERAL INFORMATION Operating temperature: 20 up to 22 up to 24 up to +55 C Storage temperature: 25 up to +70 C Temperature influence: 0.5 x measurement uncertainty per 10 K Long term drift: 0.5 x measurement uncertainty per year Usage group: II (acc. EN 60 688) Relative humidity: < 95% no condensation Altitude: 2000m max. Device to be used indoor only! MECHANICAL ATTRIBUTES Dimensions (H x B x D): 110 x 70 x 70mm Housing material: Polycarbonat Weight: 500 g Flammability class: V-0 acc. UL94, self-extinguishing, non dripping, free of halogen ORDER CODE SINEAX DM5S, PROGRAMMABLE, UP TO 4 ANALOG OUTPUTS, USB, MODBUS/RTU, METERS SINEAX DM5F, PROGRAMMABLE, 1/2 CYCLE MEASUREMENT, UP TO 4 ANALOG OUTPUTS, USB, MODBUS/RTU DM5X- 1. BASIC DEVICE Without display, for rail mounting 0 2. APPLICATION Universal version for all applications (3U,3I) 1 Single phase, 3/4-wire balanced load (3U,1I) 2 Single phase or 4-wire balanced load (1U,1I) 3 3. NOMINAL FREQUENCY RANGE 45...50/60...65 Hz 1 4. POWER SUPPLY Nominal voltage 24...230 V DC, 100...230 V AC 1 5. BUS CONNECTION Without 0 RS-485 (Modbus/RTU protocol) 1 6. OUTPUTS Without 0 1 analog output, bipolar ±20mA 1 2 analog outputs, bipolar ±20mA 2 3 analog outputs, bipolar ±20mA 3 4 analog outputs, bipolar ±20mA 4 7. TEST CERTIFICATE Without test certificate 0 Test certificate in German D Test certificate in English E 8. CONFIGURATION Basic configuration 0 PROGRAMMIERBARE STARKSTROM-UMFORMER

SMARTCOLLECT SMARTCOLLECT CLIENT SQL DATABASE MORE CLIENTS POSSIBLE SMARTCOLLECT CLIENT Graphic visualisation of queried data Export via Excel file User interface to define the data sources to be read out as well as error and warning messages via email. SMARTCOLLECT DATABASE MS SQL database (depending on the scope Express or Server) Contains the collected data Open and unencrypted SMARTCOLLECT SERVER SMARTCOLLECT SERVER Collects and configures data from active sources and channels and writes the same directly into the central database. SMARTCOLLECT software components may be installed on an individual system or on several servers or computers. Flow Energy meter SmartControl OPC-Manager CONNECTION POSSIBILITIES Camille Bauer is your competent partner and offers a wide spectrum of products for effective energy data management from the acquisition level through to the management level. The SMARTCOLLECT software acquires, stores and presents not only electrical measured variables but also variables like gas, water and heat quantities. The instrument data may be integrated either directly via Ethernet TCP/IP, Modbus RTU (RS485) or via a data collector like SmartControl. Data collector Alarm signal Temperature Energy meter Water meter Gas meter Energy meter Heat, flow rate, gas Gas meter Energy meter Flow DATAMANAGEMENT SOFTWARE

Camille Bauer Metrawatt AG Aargauerstrasse 7 5610 Wohlen Switzerland TEL +41 56 618 21 11 FAX +41 56 618 21 21 www.camillebauer.com info@cbmag.com Subject to change without notice SM-1032-00-03-EN-08.17