PHOENIX CONTACT - 01/2007

Similar documents
PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

STEP-PS/1AC/24DC/1.75

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-PS AC/10-15DC/8

TRIO-DIODE/12-24DC/2X10/1X20

QUINT-PS-3x AC/24DC/10

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-BUFFER/24DC/24DC/40

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

QUINT-PS AC/24DC/10

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/24DC/48DC/ 5

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

Extract from the online catalog

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

onlinecomponents.com

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

ASI QUINT /2.4 EFD

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

Power supply CP-C 24/5.0

QUINT-PS/ 1AC/24DC/20/CO

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power Supply HARTING pcon

Power Supply HARTING pcon

MINI MCR-SL-UI-2I(-SP)(-NC)

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Redundancy Module QUINT-DIODE/40

Redundancy unit CP-A RU

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Power supply CP-D 12/2.1 Primary switch mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-UI-REL(-SP)

DC/DC converters - QUINT-PS/24DC/24DC/

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT Features

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

ETD-BL-1T-OFF-CC- 10S

FL MC 2000E (SM40) LC

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

QUINT-UPS/ 24DC/ 24DC/10

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PI-EX-ME-2NAM/COC-24VDC

Industrial Power Supplies

Power supply CP-C 24/5.0

PI-EX-ME-2NAM/COC-120VAC

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

20A DRR Module / 40A DRR Module

PHOENIX CONTACT - 05/2007

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

MINI MCR-SL-CVS NC

PHOENIX CONTACT - 12/2007

Contact protection relay

Industrial Power Supplies

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

DC561, digital input/output module,

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

MINI MCR-SL-PT100-UI-200

onlinecomponents.com

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

DC562, digital input/output module,

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

DX561 Digital Input/Output Module

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

PSR DC/ESP4/2X1/1X2

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ERS.21

Electronic timer CT-ERD.12

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

AO561 Analog Output Module

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

AI561 Analog Input Module

SITOP in the SIMATIC Design

DC522 Digital Input/Output Module

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Transcription:

Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply unit and an uninterruptible power supply in the conventional ME housing. It secures the operation of all connected 24 V consumers in the electrical systems both in the case of an error-free supply network and in the event of mains interferences. The combined solution enables a slim design with dimensions of 67.5 x 99 x 107 mm. The wide-range input allows input voltages between 85 V AC and 264 V AC; 2 A is provided at the output with a regulated and adjustable output voltage between 22.5 V DC and 29.5 V DC. The rechargeable battery module supplies an output voltage between 27.9 V DC and 19.2 V DC in the buffer mode. A 0.8 Ah or a 1.3 Ah rechargeable battery module is used depending on the required buffer time: The module thus supplies 2 A for five minutes with the 0.8 Ah rechargeable battery module or 2 A for 30 minutes with the 1.3 Ah rechargeable battery module. The buffer time varies depending on the load current. The system availability is increased using extensive signaling through control lamps and active switching outputs. The charging process of the rechargeable battery module, the operational readiness, the buffer mode and the alarm messages are displayed before the rechargeable battery module is discharged. The service life of the rechargeable battery module can be increased by optimum battery management; for example, a temperature-compensated charging protects the rechargeable battery module at high ambient temperatures. An integrated timeout minimizes installation costs considerably. Danger! Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Make sure you always use the the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf.

Order data Description Type Order No. Pcs./Pkt. Uninterruptible power supply 2866640 1 Accessories Type Order No. Pcs./Pkt. Battery module, 24 V DC, 0.8 Ah MINI-BAT/24DC/0.8AH 2866666 1 Battery module, 24 V DC, 1.3 Ah MINI-BAT/24DC/1.3AH 2866417 1 Technical data Input data Input nominal voltage range 100 V AC... 240 V AC AC input voltage range 85 V AC... 264 V AC DC input voltage range 100 V DC... 350 V DC Buffer period (settable: 0.5 min; 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min; 30 min; continuous) Current consumption Approx. 0.6 A (230 V AC) Approx. 1.1 A (115 V AC) Inrush current limitation/i 2 t < 34 A (< 1.1 A 2 s) Power failure bypass (refer to the diagram) Typical response time 100 ms Power factor (cos phi) Approx. 0.5 Protective circuitry Varistor Input fuse, integrated 3.15 A (slow-blow, internal) Output data Nominal output voltage 24 V DC Setting range of the output voltage 22.5 V DC... 29.5 V DC (normal mode; in the buffer mode, dependent on a battery voltage of 27.9 V DC... 19.2 V DC) Output current 2 A Derating From +60 C 2.5% per Kelvin Output current limit Max. 3 A Max. capacitive load Unlimited Control deviation < 1 % (change in load, static 10%... 90%) Power loss Max 2,5 W (buffer mode) Power loss nominal load max. 15 W Maximum power dissipation idling 3.8 W Efficiency > 82 % (typical) Ascent time < 100 ms Residual ripple < 50 mv PP Peak switching voltages < 100 mv PP Connection in parallel Yes, for redundancy Surge protection against internal surge voltages Yes, < 35 V DC Resistance to reverse feed 35 V DC Signal output Power OK Status display Green LED (Power OK: LED permanently lit) 103123_00_en PHOENIX CONTACT 2

Signal output Output description Continuous current Output voltage Status display Signal output Battery charge Output description Continuous current Output voltage Status display Signal output Battery mode Output description Continuous current Output voltage Status display Relay output 200 ma 24 V LED red (malfunction/alarm: LED permanently lit) Relay output 200 ma 24 V Yellow LED (Battery charge/battery is being charged: LED flashing) Relay output 200 ma 24 V Yellow LED (Battery mode/buffer mode: LED permanently lit) Standards Electrical Equipment for Machinery EN 60204 Safety transformers for power supply units EN 61558-2-17 Electrical safety (of information technology equipment) EN 60950/VDE 0805 (SELV) UL/C-UL recognized UL 60950 Industrial control equipment UL/C-UL Listed UL 508 Electronic equipment for use in electrical power installations EN 50178/VDE 0160 (PELV) SELV EN 60950 (SELV) EN 60204 (PELV) Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Protection against electric shock, basic requirements for safe isolation in DIN VDE 0106-101 electrical equipment General data Insulation voltage input/output 2 kv (routine test) 4 kv (type test) Installation position Horizontal DIN rail NS 35, EN 60715 Degree of protection IP20 Class of protection II MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) Housing version Polyamide PA, color: green Width 67,5 mm Height 99 mm Depth 107 mm Weight 0.45 kg 103123_00_en PHOENIX CONTACT 3

Climatic data Ambient temperature (operation) -25 C... 70 C (> 60 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, no condensation) Vibration (operation) < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 15 Hz... 150 Hz, 2.3g, 90 min. Shock 30g in all directions in acc. with IEC 60068-2-27 Pollution degree in acc. with EN 50178 2 Climatic class 3K3 (in acc. with EN 60721) Conformance with EMC directive 89/336/EEC Immunity to interference in acc. with EN 61000-6-2 Discharge of static electricity in acc. with EN 61000-4-2 Housing Level 3 Contact discharge 6 kv Discharge in air 8 kv Criterion B Electromagnetic HF field in acc. with EN 61000-4-3 Housing Level 3 Frequency range 80 MHz... 2 GHz Field intensity 10 V/m Criterion A Fast transients (burst) in acc. with EN 61000-4-4 Input 4 kv (level 4 - asymmetrical: conductor to ground) Output 2 kv (level 3 - asymmetrical: conductor to ground) Signal 1 kv (level 2 - asymmetrical: conductor to ground) Criterion B Surge voltage capacities (surge) in acc. with EN 61000-4-5 Input 4 kv (level 4 - asymmetrical: conductor to ground) 2 kv (level 4 - symmetrical: conductor to conductor) Output 2 kv (Level 3 - asymmetrical) 1 kv (Level 3 - symmetrical) Signal 2 kv (Level 3 - asymmetrical) Criterion B Conducted disturbance in acc. with EN 61000-4-6 Input/Output/Signal Level 3 Frequency range 10 khz... 80 MHz Voltage 10 V Criterion A Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential Note: Criterion A: Normal operating behavior within the defined limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself EN 55011 corresponds to CISPR11 / EN 55022 corresponds to CISPR22 EN 61000 corresponds to IEC 1000 103123_00_en PHOENIX CONTACT 4

3 5 INPUT OUTPUT AC: 100-240V~ 24V 50-60Hz 2A Range: 85-264V~ 1.55-0.5A Order-No.: 28 66 64 0 100-350V 0.8-0.2A Power Supply TEMPERATURE C US LISTED -25 APPROVALS INDUSTRIAL CONTROL 43KA -25... + 70 C -13... + 158 F (>60 C/+140 F Derating) C US INFORMATION TECHNOLOGY Read installation instructions before connecting to mains www.interface.phoenixcontact.com Block diagram t...[min] Battery R1 R2 Remote On/Off Bat. Mode Charge L(+) N(-) PS +24 V/2A Structure " 7 1 1 2 0,5 30 10 20 15 IN AC 100-240 V L(+) N(-) t min max [ ] OUTDC24V 2A 22,5-28,5 V DC Bat.-Mode Bat.-Charge Power in OK Overload 2 Bat.- Mode Bat.- Charge MINI DC-UPS R1 R2 Remote Battery OFF ON 4 5 6 8 3 9 0! 1 AC input 2 DC output 3 Rechargeable battery connection 4 Active relay output: 5 Active relay output: Battery mode 6 Active relay output: Battery charge 7 Potentiometer 22.5 V DC... 29.5 V DC 8 Remote shutdown (R1, R2) 9 Red control lamp: 10 Yellow control lamp: Battery mode/ Battery charge 11 Green control lamp: Power In OK / Overload 12 Buffer time setting 0.5 min... 30 min and continuous U L!! [mm 2 ] AWG [Nm] solid stranded Torque Input 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Output 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Signal 0.2-2.5 0.2-2.5 14-24 0.5-0.6 Input data Input nominal voltage range AC input voltage range DC input voltage range Input fuse, integrated Type of connection Stripping length Output data Nominal output voltage Setting range of the output voltage Output current Type of connection Stripping length 100 V AC... 240 V AC 85 V AC... 264 V AC 100 V DC... 350 V DC 3.15 A (slow-blow, internal) COMBICON screw/plug connection 8 mm 24 V DC 22.5 V DC... 29.5 V DC (normal mode; in the buffer mode, dependent on a battery voltage of 27.9 V DC... 19.2 V DC) 2 A COMBICON screw/plug connection 8 mm 103123_00_en PHOENIX CONTACT 5

Safety and warning notes The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations (e.g. VDE, DIN) must be observed. Installation Danger! Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Before startup please ensure: The mains connection has been carried out by a competent person and protection against electric shock is guaranteed! All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! In order for the device to function in the manner intended. it is not necessary to observe any minimum spacing to other devices. The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be horizontal (connecting terminal blocks above and below). Installation position Assembly Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Dismantling Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. 103123_00_en PHOENIX CONTACT 6

3 5 INPUT OUTPUT AC: 100-240V~ 24V 50-60Hz 2A Range: 85-264V~ 1.55-0.5A Order-No.: 28 66 64 0 100-350V 0.8-0.2A Power Supply TEMPERATURE C US LISTED -25 APPROVALS INDUSTRIAL CONTROL 43KA -25... + 70 C -13... + 158 F (>60 C/+140 F Derating) C US INFORMATION TECHNOLOGY Read installation instructions before connecting to mains www.interface.phoenixcontact.com Connection, network forms 100...240 V AC networks TN-S TN-C TT it L N PE L PEN L N L1 L2 L3 L N + L N L N L N - + - + - + - The 100...240 V AC connection is made using the L and N screw connections. The device can be connected to 1-phase AC networks or to two of the phase conductors of three-phase systems (TN, TT or IT networks in acc. with VDE 0100-300/IEC 60364-3) with nominal voltages of 100 V AC...240 V AC. For operation on two of the phase conductors of a three-phase system, an isolating facility for all poles must be provided. Input 1 1 2 0,5 30 10 20 15 IN AC 100-240 V L(+) N(-) t min max [ ] OUTDC24V 2A 22,5-28,5 V DC Bat.-Mode Bat.-Charge Power in OK Overload Bat.- Mode Bat.- Charge MINI DC-UPS!! R1 R2 Remote Battery OFF ON U L The 100-...240 V AC connection is established using the L and N screw connections. The device must be installed in acc. with the regulations as in EN 60950. It must be possible to disconnect the device using a suitable isolating facility outside the power supply. The primary side line protection, for example, is suitable. For device protection, there is an internal fuse. Additional device protection is not necessary. If an internal fuse is triggered, there is most probably a malfunction in the device. In this case, the device must be inspected in the factory! 103123_00_en PHOENIX CONTACT 7

3 5 Bat.-Charge ON Battery INPUT OUTPUT AC: 100-240V~ 24V 50-60Hz 2A Range: 85-264V~ 1.55-0.5A Order-No.: 28 66 64 0 100-350V 0.8-0.2A Power Supply TEMPERATURE C US LISTED -25 APPROVALS INDUSTRIAL CONTROL 43KA -25... + 70 C -13... + 158 F (>60 C/+140 F Derating) C US INFORMATION TECHNOLOGY Read installation instructions before connecting to mains www.interface.phoenixcontact.com Output 1 2 0,5 30 10 20 15 t min max [ ] OUTDC24V 2A 22,5-28,5 V DC Bat.- Mode Bat.- Charge R1 R2 Remote OFF DC output Active switching outputs Bat.-Mode IN AC 100-240 V L(+) N(-) Power inok Overload MINI DC-UPS Control lamps U L!! The connection is established through the "OUT DC 24 V, +, " screw connections. The set output voltage is 24 V DC at the time of delivery. The output voltage from 22.5 V DC to 29.5 V DC can be set on the potentiometer. Signaling outputs Signal outputs are connected using "", "Bat.-Mode" and "Bat.-Charge" terminal blocks. Three control lamps and three active switching outputs are provided for function monitoring. State Power In OK Battery mode/ Battery charge Supply voltage OK, rechargeable battery is being charged Supply voltage OK, rechargeable battery charged (normal mode) LED on LED on LED is flashing; Battery mode output: 0 V, Battery charge: 24 V LED off; Battery mode / Battery charge output: 0 V Buffer mode LED off LED on; Battery mode output: 24 V, Battery charge: 0 V Rechargeable battery discharged, U BAT < 20.4 V DC Rechargeable battery test negative Buffer time over and remote shutdown activated LED off LED on LED off LED on; Battery mode / Battery charge output: 0 V LED off; Battery mode / Battery charge output: 0 V LED off; Battery mode / Battery charge output: 0 V LED off; output: 0 V LED off; output: 0 V LED off; output: 0 V LED on; output: 24 V LED on; output: 24 V LED off; output: 0 V 103123_00_en PHOENIX CONTACT 8

Rechargeable battery module Current [A] 2 1,5 1,0 0,5 0 0 The rechargeable battery module is connected to the power supply unit through the "Battery +" and the "Battery " terminal blocks. The fuse of the rechargeable battery module must be removed when installing or replacing the module. The following rechargeable battery modules are recommended: MINI-BAT 24DC/0.8Ah (order no. 2866666), MINI-BAT 24DC/1.3Ah (order no. 2866417) The buffer mode might be terminated after the preset time or due to an external shutdown. If the device is to be switched off after a certain period, the time for it is set using the selector switch at the front of the device. The device can be switched on in the buffer mode again after reconnecting the power supply. 30 60 90 120 MINI-BAT 24DC/0,8Ah MINI-BAT 24DC/1,3Ah 150 180 210 240 Buffer time[min] Remote shutdown ("Remote") The device has a remote shutdown with a UPS function for deliberate shutdown. Remote shutdown must be deactivated for the device to switch over to the buffer mode in the event of a supply voltage failure. Remote shutdown inactive The "Remote shutdown R1" and "Remote shutdown R2" terminal points are short-circuited (e.g. with a plug-in bridge) OR 24 V DC is present at the "Remote shutdown R2" terminal point. The power supply unit switches over to the buffer mode in the event of a supply voltage failure. Remote shutdown active The "Remote shutdown R1" and "Remote shutdown R2" terminal points are not short-circuited (e.g. with a plug-in bridge) OR 0 V is present at the "Remote shutdown R2" terminal point. - All LEDs are off. The power supply does not switch over to the buffer mode in the event of a supply voltage failure; the device switches off. The rechargeable battery module is charged when the supply voltage is reconnected, but the device remains switched off until the remote shutdown is activated. The connected consumers are fed as long as the supply voltage is available. Function Output voltage In the normal mode, the output voltage of the device conforms to the setting on the potentiometer (22.5 V DC... 29.5 V DC). If the supply voltage fails, the buffer mode is activated without any interruption and the output voltage is supplied by the rechargeable battery module. The output voltage is now directly dependent on the battery voltage and is U BAT - 0.5 V. An alarm signal is triggered if the output voltage drops below 20.4 V in the buffer mode. If the output voltage drops to 19.2 V due to a completely discharged rechargeable battery module, the device switches off and remains switched off. The device switches on automatically only after reconnecting the power supply. The device is electronically protected against short circuit and idling. 103123_00_en PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 9 Phone: +49-(0) 5235-3-00 Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com