Printlink III-ID/IV. Revision History. Date Version Description 20/08/2004 Ver First edition

Similar documents
DICOM Conformance Statement DRYPIX Link

Aloka ProSound DICOM

DICOM Conformance Statement

REGIUS CONSOLE CS-2. Revision History. Date Version Description 02/08/2004 Ver This Conformance Statement applies to DICOM3.0 (2000 version).

DICOM Conformance Statement. for ES9410 DICOM

DICOM CONFORMANCE STATEMENT FOR ZIOBASE 4.0

PRO DATA Srl. MicroPrint. DICOM PRINT SCU Conformance Statement (MicroPrint-prnsrv-print-scu.sxw)

DICOM Conformance Statement. for C911 DICOM PRINTER SERIES : C911/C931 DICOM ES9411/ES9431 DICOM Pro9431 DICOM

SwissVision TR4000. DICOM Conformance Statement Print Services. Program Version 9.3 or later Document Revision 1.4.

SCORE 3D Workstation DICOM CONFORMANCE STATEMENT

Artwork consists of twenty three (23) 8½ x 11 inch pages.

Conformance Statements for MIR CTN Applications

DICOM Conformance Statement Fuji Medical Dry Imager DRYPIX 2000 / DRYPIX LITE

DICOM 3.0 Conformance Statement. DICOM PRI v. 4.64

XPACS DICOM 3.0 Conformance Statement Document Version October 2004

ISG Technologies Inc. Viewing Stations DICOM Conformance Statement VR 3.1 for Windows Document Number: Revision: 1.

DICOM Conformance Statement for GALILEI. Software Version V6.0

DICOM Conformance Statement. CR-VW 674 for DICOM Storage DICOM Print DICOM MWM DICOM MPPS DICOM Media Storage

X-Porte DICOM Conformance Statement

QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004

DICOM. Conformance Statement. HD3 Release Rev A. Koninklijke Philips Electronics N.V All rights are reserved.

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration

DICOM Conformance Statement

AVIA (Dx MM) DICOM 3.0 Conformance Statement

Fluoroscan InSight V5.0.6 DICOM Conformance Statement

ImagePilot. DICOM 3.0 Conformance Statement. Manufacturer: 1 Sakura-machi, Hino-shi Tokyo , Japan

DICOM CONFORMANCE STATEMENT

TITAN DICOM Conformance Statement

DICOM Conformance Statement

DICOM. Conformance Statement For VINNO Medical Ultrasound System Revision 2.0. Copyright 2012 by VINNO Technology (Suzhou) Co., Ltd.

DICOM Conformance Statement

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

No. : S Rev. : A. DICOM Conformance Statement For Side Station Rev02.00

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL HDR-08A

CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT

DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number:

SYNAPSE 3D Conformance Statement FUJIFILM SYNAPSE 3D V3.0. Conformance Statement. Revision Z45N

DICOM CONFORMANCE STATEMENT

Punctual Dicom Workstation

DBSWIN DICOM Conformance Statement. DBSWIN DD-DICOM Interface. DICOM Conformance Statement V2.1

Merge OrthoCase TM V. 3.7

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

S517-E118 Dec DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement

WINRAD-32 Teleradiology System Conformance Claim

SonoWin Picture Archiving System

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL DRAD-3000A, DRAD-3000E

DICOM Conformance Statement. Allura FC II

DICOM Conformance Statement

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

DICOM Conformance Statement RadWorks 2.1 Product Line

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL ADR-1000A /R2 (MIIXR0003EAE)

DICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number:

Whole Body X-ray CT System Supria. DICOM Conformance Statement

DxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B

Abstract DCV DICOM CONFORMANCE. XrayVision DCV DICOM Conformance Statement. Abstract

Raffaello Conformance Statement for DICOM V3.0

DICOM Conformance Statement * /02* /02 MADE IN GERMANY

SonoWin Picture Archiving System

This conformance statement specifies the compliance of EponaTech s Metron-DVM to the DICOM standard Version 3.0.

Kodak Point of Care CR systems. DICOM Conformance Statement

DEJARNETTE DICOM/FFP RESEARCH SYSTEMS. DICOM Conformance Statement

nstream Version 3.1 DICOM Conformance Statement

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

SecurView DX Workstation DICOM Conformance Statement

Hologic Physician s Viewer 5.0 DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement

DICOM Conformance Statement RadWorks 4.0 Product Line

RamSoft. PowerServer. DICOM Conformance Statement

DICOM Conformance Statement

POP-Net Essential DICOM Conformance Statement

dicom PACS DX-R Version 3.0

Technical Publication. DICOM Conformance Statement. BrainSUITE NET 1.5. Document Revision 1. March 5, Copyright BrainLAB AG

DICOM CONFORMANCE STATEMENT

Philips Medical Systems. Intera Document Number April 2003

Medical Imaging Consultants, Inc.

Merge CADstream TM V. 6.2

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG

SecurView RT/TechMate Workstation DiCom Conformance statement

Diagnostics Workstation 3-0-X DICOM Conformance Statement Part Number MAN-00418

MediaWorkStation. MWS DICOM Push Interface. DICOM Conformance Statement. Version 2.0. English

CADstream DICOM Conformance Statement

UDI Doc# DICOM Conformance Statement

Matrix Server and Client DICOM Conformance Statement

g GE Medical Systems Ultrasound

Whole Body X-ray CT System Supria. DICOM Conformance Statement

Abstract. XrayVision DICOM Conformance Statement. Abstract Abstract

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0

Canon DR Image Viewer System Basic DICOM Conformance Statement

Echology Server. DICOM Conformance Statement Volume 1. <Storage and Query/Retrieve Server> Revision 1.0 Software Version 5.

Villa Sistemi Medicali DRF 4343

CARESTREAM HEALTH DOCUMENT CONTROL PAGE. Revision Description of Change Revision date

Aspen TM Ultrasound System DICOM Conformance Statement Aspen 7.0

NumaLink-3.0 DICOM 3.0 Conformance Statement

DigiRoebs 3.1. DICOM Conformance Statement V1.0. medigration GmbH. DICOM Conformace Statement Seite 1 / 38.

MediPlus TM PACS&RIS Version 2.6

Transcription:

Revision History Date Version Description 20/08/2004 Ver. 1.00 First edition NOTE: Descriptions in this document are subject to change without prior notice. Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 1

Contents 0 INTRODUCTION... 3 0.1 Abbreviations... 3 1 IMPLEMENTATION MODEL... 3 1.1 Application Data Flow Diagram... 3 1.2 Functional Definitions of AEs... 4 1.2.1 Print SCU... 4 1.2.2 Strage SCU... 4 1.3 Sequencing of Real World Activities... 4 2 AE SPECIFICATION... 4 2.1 Printlink III-ID/IV Print Management Service Class Specifications... 4 2.1.1 Association Establishment Policies... 4 2.1.2 Association in Real World Activities... 5 2.1.3 Association Acceptance Policy... 5 2.2 Printlink III-ID/IV Storage Service Class Specification... 9 2.2.1 Association Establishment Policies... 9 2.2.2 Association in Real World Activities... 10 2.2.3 SOP Class... 10 3 COMMUNICATION PROFILES... 13 3.1 Supported Communication Stack... 13 3.2 TCP/IP Stack... 13 3.2.1 Physical Media Support... 13 4 EXTENSIONS / SPECIALIZATIONS / PRIVATIZATIONS... 14 5 CONFIGURATION... 15 5.1 AE Title / Presentation Address Mapping... 15 5.2 Configurable Parameters... 15 6 SUPPORT OF EXTENDED CHARACTER SETS... 15 Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 2

0 INTRODUCTION This document describes the compatibility of the DICOM interface for Print Management System Printlink III-ID/IV with DICOM 3.0. 0.1 Abbreviations AE DICOM Application Entity IOD DICOM Information Object Definition PDU Protocol Data Unit SCU DICOM Service Class User(client using this DICOM service) SCP DICOM Service Class Provider(server providing this service) SOP Service/Object Pair UID Unique Identifier 1 IMPLEMENTATION MODEL The DICOM interface for Print Management System Printlink III-ID/IV operates as a DICOM Print Service Class SCU and DICOM Storage Service Class SCU. 1.1 Application Data Flow Diagram Diagnostic Device Video, Digital Print SCP PrintlinkIII-ID/IV Print SCU Storage SCU Storage SCP DICOM Standard Interface Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 3

1.2 Functional Definitions of AEs 1.2.1 Print SCU The Print Management Service Class SCU for Printlink III-ID/IV operates as a communication process and starts to send hard copies in response to an N-Create-RQ after a request to establish an association sent to an external AE is accepted. 1.2.2 Strage SCU The Storage Service Class SCU for Printlink III-ID/IV starts to send images in response to a C-Store-RQ after a request to establish an association sent to an external AE is accepted. 1.3 Sequencing of Real World Activities This model is not applicable with the Sequencing of Real-World Activities. 2 AE SPECIFICATION 2.1 Printlink III-ID/IV Print Management Service Class Specifications Printlink III-ID/IV sends print request associations and operates as an application entity. The following SOP classes are supported by Printlink III-ID/IV. Description Value Basic Grayscale Print Management Meta SOP Class 1.2.840.10008.5.1.1.9 Basic Film Session SOP Class 1.2.840.10008.5.1.1.1 Basic Film Box SOP Class 1.2.840.10008.5.1.1.2 Basic Grayscale Image Box SOP Class 1.2.840.10008.5.1.1.4 Printer SOP Class 1.2.840.10008.5.1.1.16 2.1.1 Association Establishment Policies This section describes the conditions for establishing association. 2.1.1.1 General Print Management SCU and SCP use the DICOM upper layer to establish associations. In doing so, Printlink III-ID/IV (SCU) starts an association which is accepted by the imager (SCP). 64KB is the maximum PDU size used. 2.1.1.2 Number of Associations The number of associations supported by Printlink III-ID/IV at the same time is one association. 2.1.1.3 Asynchronous Nature Printlink III-ID/IV manages asynchronous N-EVENT messages. However, a message is sent whenever necessary. Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 4

2.1.1.4 Implementation Identification Information The following is a list of Implementation Class UID. Description Value Printlink III-IV 1.2.392.200036.9107.500.515 Implementation Class UID Printlink III-ID 1.2.392.200036.9107.500.516 KC_PLNK3_X.XXXXX Implementation Version Name X.XXXXX indicates the software version. e.g. KC_PLNK3_1.00R00 2.1.2 Association in Real World Activities Printlink III-ID/IV (SCU) starts an association when issuing a message. 2.1.3 Association Acceptance Policy Printlink III-ID/IV (SCU) establishes an association in response to a request to establish an asynchronous N-EVENT message association for the laser imager (SCP). 2.1.3.1 Real World Activities 2.1.3.1.1 Associated Real World Activity Image data and various parameters are sent to the laser imager in order to print image data on films. 2.1.3.1.2 Presentation Context Printlink III-ID/IV (SCU) issues the presentation context that is indicated in the following table. Abstract syntax Name UID Basic Grayscale Print Management Meta SOP Class 1.2.840.10008.5.1.1.9 Basic Film Session SOP Class 1.2.840.10008.5.1.1.1 Basic Film Box SOP Class 1.2.840.10008.5.1.1.2 Basic Grayscale Image Box SOP Class 1.2.840.10008.5.1.1.4 Printer SOP Class 1.2.840.10008.5.1.1.16 Role SCP Extended negotiations can be conformed to as required. The following transmission syntax is valid against the individual SOP classes mentioned above. Name UID Implicit VR Little Endian 1.2.840.10008.1.2 Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 5

2.1.3.1.2.1 Basic Film Session SOP Class Tag Name VR VM Permitted Value (2000, 0010) Copies IS 1 Copy Count 1-99 (2000, 0020) Print Priority CS 1 Print Priority LOW MED HIGH Medium Type CLEAR FILM = Clear Base (2000, 0030) Medium Type CS 1 BLUE FILM = Blue Base DR CLEAR FILM = DR Clear Base DR BLUE FILM = DR Blue Base (2000, 0040) Film Destination CS 1 Film Destination MAGAZINE PROCESSOR BIN_1 - BIN_6 = Sorter (2000, 0060) Memory Allocation LO 1 Memory Allocation Set the required memory contents. Indicate in KB. Tags other than those listed above will not be checked. Furthermore, this model will conform to non-conforming header data as required. Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 6

2.1.3.1.2.2 Basic Film Box SOP Class Tag Name VR VM Permitted Value (0010, 0010) Patient s Name PN 1 Patient Name (0010, 0020) Patient ID LO 1 Patient ID (2010, 0010) Image Display Format ST 1 STANDARD C,R ROW R1,R2 SLIDE Annotation Display Format ID P1 = PORTRAIT L1 = LANDSCAPE (2010, 0030) Annotation Display Format ID CS 1 TM = TIME CC = Copy Count ID = Modality ID MS = Message (2010, 0040) Film Orientation CS 1 Film Orientation PORTRAIT LANDSCAPE (2010, 0050) Film Size ID CS 1 Film Size 8INX10IN 10INX12IN 11INX14IN 14INX14IN 14INX17IN (2010, 0060) Magnification Type CS 1 Magnification Type REPLICATE = Replicate interpolation CUBIC = Cubic B-Spline interpolation (2010, 0080) Smoothing Type CS 1 Smoothing Type 1-7 (2010, 0100) Borders CS 1 Border Density BLACK WHITE (2010, 0140) Trim US 1 Trim YES = With trim frame NO = Without trim frame (2010, 0150) Configuration Information ST 1 Imager LUT Indicated as shown below. KC_LUT=1-7 Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 7

2.1.3.1.2.3 Basic Grayscale Image Box SOP Class Tag Name VR VM Permitted Value (0028, 0004) Photometric Interpretation CS 1 Photometric Interpretation MONOCHROME1: Min. VOI pixel = White MONOCHROME2: Min. VOI pixel = Black (0028, 0010) Rows US 1 Pixels in imager Y orientation (0028, 0011) Columns US 1 Pixels in imager X orientation (0028, 0034) Pixel Aspect Ratio IS 2 Pixel Aspect Ratio (0028, 0100) Bits Allocated US 1 Bits allocated in pixel. Non-used bits are included. 0008:8 (8bits) 000A:16 (12bits) Those other than the above result in an error. (0028, 0101) Bits Stored US 1 Bits in 1 pixel. 0008:8 (8bits) 000C:12 (12bits) (0028, 0102) High Bit US 1 High Bit Pixel data MBS (Most significant bit) 0007:(Bits Stored = 8) 000B:(Bits Stored = 12) (0028, 0103) Pixel Representation US 1 Pixel data representation 0000 = Integer with no marks (2020, 0010) Image Position US 1 Image Position Image position that structures a page. (2020, 0020) Polarity CS 1 Polarity NORMAL REVERSE (7fe0, 0010) Pixel Data OW OB 1 Pixel data 2.1.3.1.2.4 Printer SOP Class Tag Name VR VM Permitted Value (0008, 0070) Manufacture LO 1 Manufacture (0008, 1090) Manufacture s Model Name LO 1 Manufacture s Model Name (0018, 1000) Device Serial Number LO 1 Serial Number (0018, 1020) Software Version LO 1 Software version (2110, 0010) Printer Status CS 1 Printer Status NORMAL WARNING FAILURE (2110, 0020) Printer Status Information CS 1 Printer Status Information (2110, 0030) Printer Name LO 1 Printer Name Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 8

2.2 Printlink III-ID/IV Storage Service Class Specification Printlink III-ID/IV supports the following SOP classes as a Storage Service Class SCU. SOP Class Name SOP Class UID Computed Radiography Image Storage 1.2.840.10008.5.1.4.1.1.1 CT Image Storage 1.2.840.10008.5.1.4.1.1.2 MR Image Storage 1.2.840.10008.5.1.4.1.1.4 Nuclear Medicine Image Storage 1.2.840.10008.5.1.4.1.1.20 Ultrasound Image Storage 1.2.840.10008.5.1.4.1.1.6.1 X-Ray Angiographic Image Storage 1.2.840.10008.5.1.4.1.1.12.1 X-Ray Radio Fluoroscopic Image Storage 1.2.840.10008.5.1.4.1.1.12.2 Secondary Capture Image Storage 1.2.840.10008.5.1.4.1.1.7 2.2.1 Association Establishment Policies 2.2.1.1 General Printlink utilizes the Store Service Class SCP and the DICOM upper layer to establish associations. Association is established for each SC image store and the Store Service Class SCP receives the association. The maximum PDU size used is 64KB. 2.2.1.2 Number of Associations A request to establish a single association is sent. 2.2.1.3 Asynchronous Nature One image or multiple images are managed in an association. Asynchronous processing is not supported. 2.2.1.4 Implementation Identification Information The following is a list of Implementation Class UID. Description Value Printlink III-IV 1.2.392.200036.9107.500.515 Implementation Class UID Printlink III-ID 1.2.392.200036.9107.500.516 KC_PLNK3_X.XXXXX Implementation Version Name X.XXXXX indicates the software version. e.g. KC_PLNK3_1.00R00 Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 9

2.2.2 Association in Real World Activities Printlink establishes associations from the association establishment requests to the Store Service Class SCP. 2.2.2.1 Associated Real World Activity In a Real World where an association is established, Printlink III-ID/IV sends a C-STORE request to the Remote Storage SCP and sends image data. 2.2.2.2 Presentation Context Printlink III-ID/IV accepts the following presentation context as a Storage Service Class SCU. Presentation Context Abstract syntax Name UID Role Extended Negotiation Secondary Capture Image Storage 1.2.840.10008.5.1.4.1.1.7 SCU None Transfer syntax Name UID Implicit VR Little Endian 1.2.840.10008.1.2 2.2.3 SOP Class 2.2.3.1 SC Image Store SOP Class Printlink provides adaptability to the SC Image Store SOP Class. 2.2.3.2 C-STORE Printlink III-ID/IV uses C-STORE to an image data store request in the Store Service Class SOP. 2.2.3.3 SCU Behavior Printlink III-ID/IV performs the C-STORE DIMSE Service for an SOP instance that matches the SC image IOD request. Printlink III-ID/IV recognizes the status of the C-STORE response and applies proper measures to a normal or abnormal shutdown the a service. 2.2.3.4 SCP Behavior Store Service Class SOP operates in the same way as the DIMSE Service User operation for the C-STORE Service. The Store Service Class SOP indicates that an SOP instance has been recognized properly by operating the above service properly. Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 10

2.2.3.5 SC Image IOD List of SC Image IOD IE Module Usage Patient Patient M Study General Study M Patient Study U Series General Series M Equipment General Equipment U SC Equipment M General Image M Image Pixel M Image SC Image Overlay Plane Modality LUT VOI LUT SOP Common "Overlay Plane", "Modality LUT", and "VOI LUT" are the options in the SC Image IOD. However, these are transmitted as required. List of SC Image IOD Details (The [M] under the Digit section stands for maximum length.) Tag Item VR VM Digit Type ID Data (0008, 0000) Group Length UL 1 4 1 (0008, 0005) Specific Character Set CS 2 16(M) 1C (0008, 0008) Image Type CS 2 16(M) 3 (0008, 0016) SOP Class UID UI 1 64(M) 1 (0008, 0018) SOP Instance UID UI 1 64(M) 1 (0008, 0020) Study Date DA 1 10 2 (0008, 0021) Series Date DA 1 10 3 (0008, 0023) Image Date DA 1 10 2C (0008, 0030) Study Time TM 1 16(M) 2 (0008, 0031) Series Time TM 1 16(M) 3 (0008, 0033) Image Time TM 1 16(M) 2C (0008, 0060) Modality CS 1 16(M) 1 (0008, 0064) Conversion Type CS 1 16(M) 1 (0008, 0070) Manufacture LO 1 64(M) 2 (0008, 0080) Institution Name LO 1 64(M) 3 (0008, 0081) Institution Address ST 1 1024(M) 3 Patient Data (0010, 0000) Group Length UL 1 4 1 (0010, 0010) Patient s Name PN 1 64(M) 2 (0010, 0020) Patient ID LO 1 64(M) 2 M U U U M Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 11

Tag Item VR VM Digit Type Collected Data (0018, 0000) Group Length UL 1 4 1 (0018, 1010) Secondary Capture Device ID CS 1 16(M) 3 (0018, 1012) Date of Secondary Capture DA 1 10 3 (0018, 1014) Time of Secondary Capture TM 1 16(M) 3 (0018, 1016) Secondary Capture Device Manufacture LO 1 64(M) 3 (0018, 1018) Secondary Capture Device Manufacture s Model Name LO 1 64(M) 3 (0018, 1019) Secondary Capture Device Software Version LO 1-n 64(M) 3 Related Data (0020, 0000) Group Length UL 1 4 1 (0020, 000D) Study Instance UID UI 1 64(M) 1 (0020, 000E) Series Instance UID UI 1 64(M) 1 (0020, 0013) Image Number IS 1 12(M) 2 Image Display Data (0028, 0000) Group Length UL 1 4 1 (0028, 0002) Samples per Pixel US 1 2 1 (0028, 0004) Photometric Interpretation CS 1 16(M) 1 (0028, 0010) Rows US 1 2 1 (0028, 0011) Columns US 1 2 1 (0028, 0100) Bits Allocated US 1 2 1 (0028, 0101) Bits Stored US 1 2 1 (0028, 0102) High Bit US 1 2 1 (0028, 0103) Pixel Representation US 1 2 1 (0028, 3010) VOI LUT Sequence SQ 1 2 1C >(0028, 3002) LUT Descriptor US 3 2 1C >(0028, 3003) LUT Explanation LO 1 64(M) 3 >(0028, 3006) LUT Data US 4096 2 1C Image Pixel Data (7FE0, 0000) Group Length UL 1 4 1 (7FE0, 0010) Pixel Data OW 1 65536(M) 1 Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 12

3 COMMUNICATION PROFILES 3.1 Supported Communication Stack The DICOM TCP/IP Network Communication Support defined in DICOM PS3.8 is provided. 3.2 TCP/IP Stack The TCP/IP stack is succeeded from the Windows XP system. 3.2.1 Physical Media Support The following physical media is supported by standard. - 10 BaseT, 100BaseTX Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 13

4 EXTENSIONS / SPECIALIZATIONS / PRIVATIZATIONS The following attributes are reserved in the Basic Film Box SOP Class. - (0010,0010) Patient s Name - (0010,0020) Patient ID The following attributes are reserved in the Basic Film Box SOP Class. - (2011,0010) - (2011,0010) - (2011,1011) - (2011,1021) - (2011,1030) - (2011,1031) - (2011,1040) - (2011,1050) - (2011,1060) - (2011,1070) - (2011,1080) - (2011,1090) The following attributes are reserved in the Printer SOP Class. - (2011,0010) - (2011,10A0) - (2011,10A1) - (2011,10B0) - (2011,10B1) - (2011,10B2) - (2011,10C0) - (2011,10C1) - (2011,10D0) - (2011,10D1) - (2011,10E0) - (2011,10F0) The following attributes are added in the SC Image IOD. - (2010 0010) - (2010 0040) - (2010 0050) - (2010 0060) - (2010 0080) - (2010 0100) - (2010 0110) - (2010 0140) - (2010 0150) - (2011 0010) - (2011 1011) - (2011 1021) - (2011 1040) - (2011 1080) - (2020 0010) - (2020 0020) Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 14

5 CONFIGURATION 5.1 AE Title / Presentation Address Mapping The conformance from a Printlink III-ID/IV AE title to a presentation address is performed by making indications to a configuration file. 5.2 Configurable Parameters Specify the following items to the environment data file. - AE title - Printlink III-ID/IV name (Default: KC_PLNK3_SCU) - IP address - TCP board number 100-9999 (for transmission) - TCP board number 100-9999 (for receiving N-EVENT) 6 SUPPORT OF EXTENDED CHARACTER SETS For elements in which the VR is SH (short column), LO (long column), ST (short text), LT (long text), or PN (person's name), extended characters can be used by specifying an extended character repertoire in the attribute specific character group (0008,0005) for SC Image IOD. The extended character repertoire uses ISO 2022 IR87 or ISO 2022 IR13 ISO2022 IR87. Printlink III-ID/IV DICOM 3.0 Conformance Statement Ver.1.00 2004/08/20 15

Blank page

No. 26-2, Nishishinjuku 1-chome, Shinjuku-ku, Tokyo 163-0512, Japan